DFDamien Fisher

Damien Fisher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Damien Fisher has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Stephen J. Vincent

    Centre for Vision and Eye Research, Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia

    16 shared publications
  • Michael J. Collins

    Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia

    13 shared publications
  • David Alonso-Caneiro

    School of Science, Technology and Engineering, University of Sunshine Coast, Petrie, Australia

    10 shared publications
  • Asif Iqbal

    Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia

    7 shared publications
  • Michael J. Collins

    Contact Lens and Visual Optics Laboratory, School of Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, QLD, Australia

    4 shared publications
  • Stephen J. Vincent

    Contact Lens and Visual Optics Laboratory, School of Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, QLD, Australia

    3 shared publications

Latest Publications

  • Open Access

    Scleral Lens Fenestrations and Fluid Reservoir Debris

    by Damien Fisher, Luisa Holguin Colorado, David Alonso-Caneiro, Stephen J. Vincent

    Purpose: The accumulation of debris within the fluid reservoir during scleral lens wear can adversely affect vision, resulting in the need for lens removal. This study aimed to quantify the effect of incorporating limbal scleral lens fenestrations upon fluid reservoir debris. Methods: Twenty healthy adults (mean age 32 ± 11 years, 10 females/10 males) with normal corneas wore non-fenestrated and fenestrated (3 × 1 mm diameter limbal fenestrations separated by 120°) OneFitMed+ scleral lenses (No.7 Contact Lenses) in both eyes (on separate days) for 3 h. All other scleral lens parameters were held constant except for the addition of the fenestrations by the manufacturer. Customised image analysis (MATLAB) was used to quantify central fluid reservoir debris (an average and total intensity metric) from Scheimpflug images of the right eye. Results: Fluid reservoir debris increased over time ( p < 0.001), more so for non-fenestrated lenses. After 3 h, the increase in fluid reservoir debris was greater for the non-fenestrated lens design (total metric increase: non-fenestrated 66 ± 21 vs fenestrated 14 ± 7 arbitrary units [ p = 0.03], average metric increase: non-fenestrated 9 ± 2 vs fenestrated 5 ± 1 arbitrary units [ p = 0.07]). There was no significant difference in the magnitude of debris for fenestrated lenses fitted with or without an air bubble ( p = 0.80). There was no association between central corneal oedema and the fluid reservoir intensity metrics for either the fenestrated ( R 2 ≤ 0.08, p ≥ 0.28) or non-fenestrated lenses ( R 2 ≤ 0.001, p ≥ 0.90). Conclusions: After 3 h, non-fenestrated lenses displayed a 2 (average metric) to 4.8 times (total metric) greater increase in central fluid reservoir debris than fenestrated lenses. This suggests a potential role for fenestrated lens designs in managing fluid reservoir debris; however, longer-term studies of participants with ocular disease are required. Clinical Trial: This study was registered on the Australian New Zealand Clinical Trials Registry (Registration number 12622001164785p), date of registration 24/8/2022.

  • Open Access

    Scleral lens peripheral modifications and regional variations in corneal oedema

    by Asif Iqbal, Damien Fisher, David Alonso-Caneiro, Michael J. Collins, Stephen J. Vincent

  • Open Access

    Tear Dynamics During Fenestrated Scleral Lens Wear: A Pilot Study

    by Damien Fisher, Asif Iqbal, David Alonso-Caneiro, Michael J. Collins, Stephen J. Vincent

    Purpose: To develop a Scheimpflug-based image analysis technique to quantify tear exchange during scleral lens wear and investigate fluid reservoir tear dynamics during fenestrated lens wear. Methods: Nine healthy participants wore a scleral lens (KATT™, Capricornia Contact Lenses) with a single 0.3 mm diameter limbal fenestration in one eye for 90 min. Central (0–2.5 mm from the corneal apex) and peripheral (−1.0 to 0 mm from the scleral spur) stromal cornea oedema was measured using optical coherence tomography. Scheimpflug images were obtained during lens wear at multiple time points following the application of sodium fluorescein to the bulbar conjunctiva. These images were exported and annotated manually to select the region of interest (the fluid reservoir) from which the intensity of each pixel was extracted to provide a measure of fluorescent intensity (in arbitrary units [AU] on a scale of 0–255) throughout lens wear across the central 10 mm. Results: The coefficient of repeatability for central fluid reservoir intensity measurements was 7 AU (on a scale of 0–255 AU). Fluid reservoir fluorescent intensity varied with measurement location ( p < 0.001), being greater towards the periphery (4 and 5 mm from the centre). On average, intensity differences between the peripheral and central fluid reservoir diminished within 10 min of sodium fluorescein application. Two patterns of tear dynamics were observed and were classified as low and high flow. Low flow participants ( n = 6) exhibited greater central (3.72× more) and peripheral (2.25× more) corneal oedema, but the difference was not statistically significant. Conclusions: The ingress and mixing of sodium fluorescein within the fluid reservoir stabilised between central and peripheral locations after 10 min of fenestrated scleral lens wear. Two patterns of tear dynamics were observed (low and high flow), with low flow participants exhibiting greater corneal oedema. Future research utilising the developed technique may provide further insights into tear exchange during scleral lens wear with different fenestration sizes and configurations.


  • Open Access

    The Effect of Limbal Fenestrations on Scleral Lens-Induced Central Corneal Oedema

    by Damien Fisher, David Alonso-Caneiro, Stephen J. Vincent

    Purpose: Persistent corneal oedema can lead to reduced visual performance and longer-term ocular complications in eyes with reduced endothelial cell function. The aim of this study was to quantify the effect of incorporating limbal scleral lens fenestrations on central corneal oedema. Methods: Twenty young healthy adults (mean age ± standard deviation 32 ± 11 years) with normal corneas wore non-fenestrated and fenestrated (3 × 1 mm limbal fenestrations separated by 120°) OneFitMed+ scleral lenses in both eyes (on separate days) for 3 h. All other scleral lens parameters were held constant except for the addition of the fenestrations. Central fluid reservoir thickness and corneal oedema were quantified using optical coherence tomography, and corrections were made for small thickness variations between lens conditions. Results: The corrected central corneal oedema was significantly reduced following fenestrated lens wear (0.80 ± 0.93%) compared to non-fenestrated lens wear (1.32 ± 0.81%; a 39% relative reduction, p = 0.02). The reduction in central corneal oedema with the fenestrated lens was slightly greater for participants without an air bubble in the fluid reservoir ( n = 10, 0.73 ± 0.80% less oedema, 45% relative reduction) compared to those with an air bubble ( n = 10, 0.30 ± 1.05% less oedema, 30% relative reduction) but was not statistically significant ( p = 0.31). Conclusion: The incorporation of three 1 mm diameter limbal fenestrations separated by 120° reduced the magnitude of central corneal oedema by 39% on average in healthy eyes compared to a non-fenestrated scleral lens. A reduction in central corneal oedema was still observed without the presence of an air bubble within the fluid reservoir. Future studies investigating the long-term efficacy of different fenestration configurations in clinical populations are warranted. Clinical trial: This study was registered on the Australian New Zealand Clinical Trials Registry (Registration number 12622001164785p), date of registration 24 August, 2022.


  • Open Access

    Scleral lens landing zone toricity and tear exchange

    by Asif Iqbal, Damien Fisher, David Alonso-Caneiro, Michael J Collins, Stephen J Vincent


  • Open Access

    Regional variations in corneal oedema during open‐eye fenestrated scleral lens wear

    by Asif Iqbal, Damien Fisher, David Alonso‐Caneiro, Michael J. Collins, Stephen J. Vincent

    Purpose: To compare the magnitude of central, mid‐peripheral and peripheral stromal corneal oedema induced during short‐term fenestrated and non‐fenestrated scleral lens wear. Methods: Nine healthy participants wore a non‐fenestrated and a fenestrated (0.3‐mm diameter limbal fenestration) scleral lens (KATT™, Capricornia Contact Lenses), hexafocon B material (Dk 141 × 10 −11 cm 3 O 2 (cm)/[(s) (cm 2 ) (mmHg)]) in one eye under open‐eye conditions for 90 min on two separate days. Scleral lens thickness, fluid reservoir thickness and stromal corneal oedema were measured using high‐resolution optical coherence tomography. Stromal oedema was quantified across the central (0–2.5 mm from the corneal apex), mid‐peripheral (−3.0 to −1.0 mm from the scleral spur) and peripheral (−1.0 to 0 mm from the scleral spur) cornea with the lens in situ. The magnitude of oedema was corrected based on variations in fluid reservoir thickness between the lens conditions. Results: There was a significant effect of lens type ( p = 0.04) on stromal oedema, with less oedema observed with the fenestrated (0.36 ± 0.45%) compared to the non‐fenestrated lenses (1.24 ± 0.27%), averaged across all corneal locations. A significant lens type by corneal location interaction was also observed ( p = 0.05), with less oedema observed in the peripheral region for the fenestrated (−0.15 ± 0.98%) compared to the non‐fenestrated lenses (1.81 ± 0.57%) ( p = 0.048). A fenestration location by corneal location interaction was also observed ( p = 0.02), indicating a greater reduction in oedema closer to the fenestration. Conclusions: Central and mid‐peripheral stromal oedema was similar during fenestrated and non‐fenestrated lens wear; however, fenestrated lenses displayed significantly less oedema in the peripheral cornea. This is most likely due to increased oxygen delivery in proximity to the fenestration.


  • Open Access

    Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study

    by Asif Iqbal, Damien Fisher, David Alonso‐Caneiro, Michael J. Collins, Stephen J. Vincent

    Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time. Methods: As a proof of concept, a healthy participant wore a corneal and a scleral rigid lens on separate days. After lens application, 2% sodium fluorescein was instilled, and ESP images were captured at intervals over a 30‐min period for corneal and a 90‐min period for the scleral lens. Fluorescence intensity data were extracted and analysed using MATLAB, restricted to a region of interest centred on the contact lens. The fluorescence intensity was fitted with an exponential decay curve to quantify tear exchange. Results: Fluorescence intensity decreased over time for both lenses, with a faster decay rate being observed for the corneal lens. The scleral lens showed an initial ingress of fluorescein into the fluid reservoir, then a slow decay in fluorescence intensity due to limited tear exchange. The decay rate for the corneal lens was approximately four times faster than the scleral lens, with the time to reach 50% decay of ~42 min for the corneal lens compared to ~157 min for the scleral lens. Conclusion: A new method was developed to quantify tear exchange using a commercially available corneoscleral profilometer, offering a wider field of view than existing techniques. This approach has clinical potential in scleral lens practice for identifying landing zone misalignment and improving the understanding of post‐lens tear dynamics, particularly in cases involving scleral lens modifications or patients experiencing midday fogging.


  • Contact lens fenestrations and channels in relation to tear exchange and corneal oedema

    by Damien Fisher, Michael J Collins, Stephen J Vincent

    Oxygen delivery and tear exchange are considered essential to maintain corneal homoeostasis during contact lens wear. Since the 1940s, fenestrations and back surface channels have been utilised in scleral, corneal rigid, and soft contact lenses in an attempt to enhance corneal oxygen transmission, facilitate the removal of carbon dioxide from the post-lens tear layer, minimise corneal oedema and prevent post-lens tear stagnation. This review examines the use of contact lens fenestrations and channels in both clinical and laboratory settings, and the effect of these modifications upon tear exchange and corneal oedema. Despite almost a century of modifying contact lenses to alter tear dynamics and promote corneal health, the evidence regarding the efficacy of fenestrations and channels is mixed.


  • Open Access

    The central and peripheral corneal response to short‐term hypoxia

    by Asif Iqbal, Damien Fisher, David Alonso‐Caneiro, Michael J. Collins, Stephen J. Vincent

    Purpose: To quantify the magnitude and recovery of central and limbal corneal oedema induced by short‐term unilateral eyelid closure without contact lens wear. Methods: The left eye of 10 adults with healthy corneas was patched using a folded eye pad for 30 min. High‐resolution optical coherence tomography images (which captured the limbal and central corneal regions simultaneously) were obtained before patching, immediately after eye opening and again at 1, 2, 5, 6, 9, 10, 14 and 15 mins after eyelid opening. Oedema was measured from the limbus (scleral spur) to the central cornea (thinnest corneal location) along the horizontal meridian. Results: A greater amount of limbal oedema was noted (mean [SD] 3.84 [1.79] %) compared to the central cornea (2.48 [0.61] %; p = 0.04) after 30 mins of unilateral eyelid closure. Both central and limbal corneal oedema recovered rapidly following eyelid opening, with no significant differences in the rate of corneal recovery between corneal locations ( p = 0.90). Conclusions: Short‐term unilateral eyelid closure resulted in ~55% more relative oedema in the limbal region compared to the central cornea. Rapid recovery of oedema and corneal overshoot (thinning beyond the baseline corneal thickness) was observed within 1–2 min of eyelid opening for both central and peripheral regions.


  • Open Access

    The effect of lens and fitting characteristics upon scleral lens centration

    by Damien Fisher, Michael J. Collins, Stephen J. Vincent

    Purpose: To quantify the impact of varying central fluid reservoir depth, lens thickness/mass and the addition of a peripheral fenestration upon scleral lens centration. Methods: Ten young, healthy adults participated in a series of repeated‐measures experiments involving short‐term (90 min) open eye scleral lens wear. Scleral lens parameters (material, back optic zone radius, diameter, back vertex power and landing zone) were controlled across all experiments, and the central fluid reservoir depth (ranging from 144 to 726 μm), lens thickness (ranging from 150 to 1200 μm), lens mass (101–241 mg) and lens design (with or without a single 0.3 mm peripheral fenestration) were altered systematically. Scleral lens decentration was quantified using over‐topography maps. Results: On average, scleral lens centration varied by p < 0.001). Changes in lens thickness or the addition of a peripheral fenestration did not cause clinically significant changes in centration (<0.10 mm on average) when controlling for fluid reservoir depth. Central fluid reservoir depth was the best predictor of horizontal and vertical lens decentration, explaining 62–73% of the observed variation, compared to 40–44% for lens thickness and mass. Conclusion: Scleral lens decentration remained relatively stable over 90 min of lens wear. A greater initial central fluid reservoir depth resulted in significantly more lens decentration, particularly inferiorly. Large variations in lens thickness, mass or the addition of a single peripheral fenestration did not substantially affect lens centration.