Henrietta Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Henrietta Wang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Michael Kalloniatis
University of Houston College of Optometry Houston Texas USA
11 shared publications - Jack Phu
School of Optometry and Vision Science, University of New South Wales, Kensington, Australia
9 shared publications - Angelica Ly
School of Optometry and Vision Science, UNSW Sydney, Sydney, Australia
2 shared publications - Hamza Shah
University of Houston College of Optometry Houston Texas USA
2 shared publications - Kaitlyn A. Sapoznik
University of Houston College of Optometry Houston Texas USA
2 shared publications Katherine Masselos
Centre for Eye Health, University of New South Wales, Kensington, NSW, Australia
2 shared publications
Latest Publications
- Open Access
- 29 July 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (8) , e70090
Case series: The role of retinal ischemia in the pathogenesis and clinical manifestation of diabetic retinopathy
Purpose: To highlight retinal ischemia as an important component of diabetic retinopathy (DR) pathogenesis, a significant prognostic factor, and a driver of various DR complications, including neovascularization. We aim to describe the main features of ischemic areas that can be identified through fundoscopy, color fundus photography, optical coherence tomography (OCT), and OCT angiography and provide clinicians with a step‐by‐step approach to identifying prognostically unfavorable markers of DR and accurately staging DR to improve management and prevent severe proliferative DR. Case Reports: Cases of DR with subtle but significant retinal findings that are not readily identifiable unless a systematic multimodal imaging approach is used. We emphasize the presence of retinal ischemia in each case and show how to identify retinal vascular nonperfusion and its complications. Conclusions: Advanced stages of DR may lack prominent fundus findings and may be easily misdiagnosed as milder DR without a comprehensive multimodal imaging diagnostic approach.
- 29 July 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (8) , e70090
Open AccessCase series: The role of retinal ischemia in the pathogenesis and clinical manifestation of diabetic retinopathy
Purpose: To highlight retinal ischemia as an important component of diabetic retinopathy (DR) pathogenesis, a significant prognostic factor, and a driver of various DR complications, including neovascularization. We aim to describe the main features of ischemic areas that can be identified through fundoscopy, color fundus photography, optical coherence tomography (OCT), and OCT angiography and provide clinicians with a step‐by‐step approach to identifying prognostically unfavorable markers of DR and accurately staging DR to improve management and prevent severe proliferative DR. Case Reports: Cases of DR with subtle but significant retinal findings that are not readily identifiable unless a systematic multimodal imaging approach is used. We emphasize the presence of retinal ischemia in each case and show how to identify retinal vascular nonperfusion and its complications. Conclusions: Advanced stages of DR may lack prominent fundus findings and may be easily misdiagnosed as milder DR without a comprehensive multimodal imaging diagnostic approach.
- Open Access
- 1 March 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (3) , e70036
Case series: The value of fundus autofluorescence in inherited macular disease
Purpose: To evaluate the diagnostic utility of fundus autofluorescence (FAF) imaging in identifying and characterizing phenotypically classified inherited macular dystrophies. In this way, we aim to provide methods by which eye care practitioners can link FAF imaging and other clinical results or imaging modalities to aid their clinical decision‐making. Case Reports: Phenotypically identified inherited macular dystrophies, including Stargardt disease and related ABCA4 mutations, Best vitelliform dystrophy, pattern dystrophies, and cone and cone‐rod dystrophies, are discussed. Conclusions: We provide evidence that the use of FAF alone and in combination with other clinical results and imaging modalities can assist in the diagnosis of a range of inherited macular dystrophies.
- 1 March 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (3) , e70036
Open AccessCase series: The value of fundus autofluorescence in inherited macular disease
Purpose: To evaluate the diagnostic utility of fundus autofluorescence (FAF) imaging in identifying and characterizing phenotypically classified inherited macular dystrophies. In this way, we aim to provide methods by which eye care practitioners can link FAF imaging and other clinical results or imaging modalities to aid their clinical decision‐making. Case Reports: Phenotypically identified inherited macular dystrophies, including Stargardt disease and related ABCA4 mutations, Best vitelliform dystrophy, pattern dystrophies, and cone and cone‐rod dystrophies, are discussed. Conclusions: We provide evidence that the use of FAF alone and in combination with other clinical results and imaging modalities can assist in the diagnosis of a range of inherited macular dystrophies.
- Open Access
- 26 July 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (6) , 1359-1375
Visual field defects in dementia: A scoping review
Introduction: This review aimed to systematically assess the literature reporting the relationship between dementia and standard automated perimetry results, including sensitivity, global indices, patterns of visual field defect and reliability indices. Design: A scoping review and meta‐analysis were conducted. Setting and Participants: Published studies in any setting which reported on standard automated perimetry results (any of: global indices, pointwise sensitivities, reliability indices and/or patterns of visual field defects) in participants with (‘cases’) or without (‘controls’) dementia due to neurodegenerative disease. Methods: Four databases were searched (to July 2024) and included published studies comparing the perimetry results of cases and controls. Standardised mean differences with 95% confidence intervals were calculated where data were available. Studies with qualitative visual field results were identified and described. The Joanna Briggs Institute checklists were used for quality assessment. Results: Four studies were included in the meta‐analysis component of the study. Standardised mean differences between cases and controls were −1.16 (−1.47, −0.86) and −0.96 (−1.26, −0.67) for mean deviation and pattern standard deviation, respectively. The standardised mean differences for fixation loss, false positive and false negative rates were −0.30 (−0.57, −0.04), −0.33 (−0.60, −0.06) and −1.12 (−1.40, −0.83), respectively. In all instances, cases had poorer results than controls. Hemianopias were the most common visual field defect pattern, followed by quadrantonopia, with left‐sided defects more common than right. Several studies illustrated visual field sensitivity and deviation maps, from which examples of inattentive defects were identified. Conclusions: Cross‐sectional studies, case series and case reports demonstrated worse visual function and reliability indices in patients with dementia in comparison to controls. Several knowledge gaps and opportunities for further study were identified, including potentially using patterns of poor test reliability and inattention as surrogate markers of cognitive impairment and its relationship with quantitative evaluation of cognitive function.
- 26 July 2025
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 45 (6) , 1359-1375
Open AccessVisual field defects in dementia: A scoping review
Introduction: This review aimed to systematically assess the literature reporting the relationship between dementia and standard automated perimetry results, including sensitivity, global indices, patterns of visual field defect and reliability indices. Design: A scoping review and meta‐analysis were conducted. Setting and Participants: Published studies in any setting which reported on standard automated perimetry results (any of: global indices, pointwise sensitivities, reliability indices and/or patterns of visual field defects) in participants with (‘cases’) or without (‘controls’) dementia due to neurodegenerative disease. Methods: Four databases were searched (to July 2024) and included published studies comparing the perimetry results of cases and controls. Standardised mean differences with 95% confidence intervals were calculated where data were available. Studies with qualitative visual field results were identified and described. The Joanna Briggs Institute checklists were used for quality assessment. Results: Four studies were included in the meta‐analysis component of the study. Standardised mean differences between cases and controls were −1.16 (−1.47, −0.86) and −0.96 (−1.26, −0.67) for mean deviation and pattern standard deviation, respectively. The standardised mean differences for fixation loss, false positive and false negative rates were −0.30 (−0.57, −0.04), −0.33 (−0.60, −0.06) and −1.12 (−1.40, −0.83), respectively. In all instances, cases had poorer results than controls. Hemianopias were the most common visual field defect pattern, followed by quadrantonopia, with left‐sided defects more common than right. Several studies illustrated visual field sensitivity and deviation maps, from which examples of inattentive defects were identified. Conclusions: Cross‐sectional studies, case series and case reports demonstrated worse visual function and reliability indices in patients with dementia in comparison to controls. Several knowledge gaps and opportunities for further study were identified, including potentially using patterns of poor test reliability and inattention as surrogate markers of cognitive impairment and its relationship with quantitative evaluation of cognitive function.
- 3 March 2025
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 108 (8) , 1081-1082
Re: ‘Using ChatGPT-4 in visual field test assessment’
- 3 March 2025
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 108 (8) , 1081-1082
Re: ‘Using ChatGPT-4 in visual field test assessment’
- Open Access
- 16 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-18
Predicting visual field global and local parameters from OCT measurements using explainable machine learning
Glaucoma is characterised by progressive vision loss due to retinal ganglion cell deterioration, leading to gradual visual field (VF) impairment. The standard VF test may be impractical in some cases, where optical coherence tomography (OCT) can offer predictive insights into VF for multimodal diagnoses. However, predicting VF measures from OCT data remains challenging. To address this, five regression models were developed to predict VF measures from OCT, Shapley Additive exPlanations (SHAP) analysis was performed for interpretability, and a clinical software tool called OCT to VF Predictor was developed. To evaluate the models, a total of 268 glaucomatous eyes (86 early, 72 moderate, 110 advanced) and 226 normal eyes were included. The machine learning models outperformed recent OCT-based VF prediction deep learning studies, with correlation coefficients of 0.76, 0.80 and 0.76 for mean deviation, visual field index and pattern standard deviation, respectively. Introducing the pointwise normalisation and step-size concept, a mean absolute error of 2.51 dB was obtained in pointwise sensitivity prediction, and the grayscale prediction model yielded a mean structural similarity index of 77%. The SHAP-based analysis provided critical insights into the most relevant features for glaucoma diagnosis, showing promise in assisting eye care practitioners through an explainable AI tool.
- 16 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-18
Open AccessPredicting visual field global and local parameters from OCT measurements using explainable machine learning
Glaucoma is characterised by progressive vision loss due to retinal ganglion cell deterioration, leading to gradual visual field (VF) impairment. The standard VF test may be impractical in some cases, where optical coherence tomography (OCT) can offer predictive insights into VF for multimodal diagnoses. However, predicting VF measures from OCT data remains challenging. To address this, five regression models were developed to predict VF measures from OCT, Shapley Additive exPlanations (SHAP) analysis was performed for interpretability, and a clinical software tool called OCT to VF Predictor was developed. To evaluate the models, a total of 268 glaucomatous eyes (86 early, 72 moderate, 110 advanced) and 226 normal eyes were included. The machine learning models outperformed recent OCT-based VF prediction deep learning studies, with correlation coefficients of 0.76, 0.80 and 0.76 for mean deviation, visual field index and pattern standard deviation, respectively. Introducing the pointwise normalisation and step-size concept, a mean absolute error of 2.51 dB was obtained in pointwise sensitivity prediction, and the grayscale prediction model yielded a mean structural similarity index of 77%. The SHAP-based analysis provided critical insights into the most relevant features for glaucoma diagnosis, showing promise in assisting eye care practitioners through an explainable AI tool.
- Open Access
- 7 March 2024
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (5) , 482-498
Optical coherence tomography angiography in the diagnosis of ocular disease
Clinical imaging provided by optical coherence tomography (OCT) and its variant, OCT-angiography (OCT-A), has revolutionised eyecare practice. The imaging techniques allow for the identification and quantification of ocular structures, supporting the diagnosis and prognosis of eye disease. In this review, an overview of the usefulness of OCT-A imaging in the diagnosis and management of a range of ocular conditions is provided when used in isolation or in combination with other imaging modalities and measures of visual function (visual field results). OCT-A imaging has the capacity to identify and quantify ocular vasculature non-invasively, thereby assisting the clinician in the diagnosis or to determine the efficacy of intervention in ocular conditions impacting retinal vasculature. Thus, additional clinically useful information can be obtained in eye diseases involving conditions such as those impacting retinal vessel occlusion, in diabetic retinopathy, inherited retinal dystrophy, age-related macular degeneration, choroidal neovascularisation and optic nerve disorders. Through a clinical case series, various ocular conditions are reviewed, and the impact of OCT-A imaging is discussed. Although OCT-A imaging has great promise and is already used in clinical management, there is a lack of set standards to characterise altered vascular features in disease and consequently for prognostication, primarily due to a lack of large-scale clinical trials and variability in OCT-A algorithms when generating quantitative parameters.
- 7 March 2024
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (5) , 482-498
Open AccessOptical coherence tomography angiography in the diagnosis of ocular disease
Clinical imaging provided by optical coherence tomography (OCT) and its variant, OCT-angiography (OCT-A), has revolutionised eyecare practice. The imaging techniques allow for the identification and quantification of ocular structures, supporting the diagnosis and prognosis of eye disease. In this review, an overview of the usefulness of OCT-A imaging in the diagnosis and management of a range of ocular conditions is provided when used in isolation or in combination with other imaging modalities and measures of visual function (visual field results). OCT-A imaging has the capacity to identify and quantify ocular vasculature non-invasively, thereby assisting the clinician in the diagnosis or to determine the efficacy of intervention in ocular conditions impacting retinal vasculature. Thus, additional clinically useful information can be obtained in eye diseases involving conditions such as those impacting retinal vessel occlusion, in diabetic retinopathy, inherited retinal dystrophy, age-related macular degeneration, choroidal neovascularisation and optic nerve disorders. Through a clinical case series, various ocular conditions are reviewed, and the impact of OCT-A imaging is discussed. Although OCT-A imaging has great promise and is already used in clinical management, there is a lack of set standards to characterise altered vascular features in disease and consequently for prognostication, primarily due to a lack of large-scale clinical trials and variability in OCT-A algorithms when generating quantitative parameters.
- Open Access
- 16 January 2024
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 44 (2) , 426-441
Frontloading visual field tests detect earlier mean deviation progression when applied to real‐world‐derived early‐stage glaucoma data
Purpose: To examine the diagnostic accuracy of performing two (frontloaded) versus one (clinical standard) visual field (VF) test per visit for detecting the progression of early glaucoma in data derived from clinical populations. Methods: A computer simulation model was used to follow the VFs of 10,000 glaucoma patients (derived from two cohorts: Heijl et al., Swedish cohort; and Chauhan et al., Canadian Glaucoma Study [CGS]) over a 10‐year period to identify patients whose mean deviation (MD) progression was detected. Core data (baseline MD and progression rates) were extracted from two studies in clinical cohorts of glaucoma, which were modulated using SITA‐Faster variability characteristics from previous work. Additional variables included follow‐up intervals (six‐monthly or yearly) and rates of perimetric data loss for any reason (0%, 15% and 30%). The main outcome measures were the proportions of progressors detected. Results: When the Swedish cohort was reviewed six‐monthly, the frontloaded strategy detected more progressors compared to the non‐frontloaded method up to years 8, 9 and 10 of follow‐up for 0%, 15% and 30% data loss conditions. The time required to detect 50% of cases was 1.0–1.5 years less for frontloading compared to non‐frontloading. At 4 years, frontloading increased detection by 26.7%, 28.7% and 32.4% for 0%, 15% and 30% data loss conditions, respectively. Where both techniques detected progression, frontloading detected progressors earlier compared to the non‐frontloaded strategy (78.5%–81.5% and by 1.0–1.3 years when reviewed six‐monthly; 81%–82.9% and by 1.2–2.1 years when reviewed yearly). Accordingly, these patients had less severe MD scores (six‐monthly review: 0.63–1.67 dB ‘saved’; yearly review: 1.10–2.87 dB). The differences increased with higher rates of data loss. Similar tendencies were noted when applied to the CGS cohort. Conclusions: Frontloaded VFs applied to clinical distributions of MD and progression led to earlier detection of early glaucoma progression.
- 16 January 2024
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 44 (2) , 426-441
Open AccessFrontloading visual field tests detect earlier mean deviation progression when applied to real‐world‐derived early‐stage glaucoma data
Purpose: To examine the diagnostic accuracy of performing two (frontloaded) versus one (clinical standard) visual field (VF) test per visit for detecting the progression of early glaucoma in data derived from clinical populations. Methods: A computer simulation model was used to follow the VFs of 10,000 glaucoma patients (derived from two cohorts: Heijl et al., Swedish cohort; and Chauhan et al., Canadian Glaucoma Study [CGS]) over a 10‐year period to identify patients whose mean deviation (MD) progression was detected. Core data (baseline MD and progression rates) were extracted from two studies in clinical cohorts of glaucoma, which were modulated using SITA‐Faster variability characteristics from previous work. Additional variables included follow‐up intervals (six‐monthly or yearly) and rates of perimetric data loss for any reason (0%, 15% and 30%). The main outcome measures were the proportions of progressors detected. Results: When the Swedish cohort was reviewed six‐monthly, the frontloaded strategy detected more progressors compared to the non‐frontloaded method up to years 8, 9 and 10 of follow‐up for 0%, 15% and 30% data loss conditions. The time required to detect 50% of cases was 1.0–1.5 years less for frontloading compared to non‐frontloading. At 4 years, frontloading increased detection by 26.7%, 28.7% and 32.4% for 0%, 15% and 30% data loss conditions, respectively. Where both techniques detected progression, frontloading detected progressors earlier compared to the non‐frontloaded strategy (78.5%–81.5% and by 1.0–1.3 years when reviewed six‐monthly; 81%–82.9% and by 1.2–2.1 years when reviewed yearly). Accordingly, these patients had less severe MD scores (six‐monthly review: 0.63–1.67 dB ‘saved’; yearly review: 1.10–2.87 dB). The differences increased with higher rates of data loss. Similar tendencies were noted when applied to the CGS cohort. Conclusions: Frontloaded VFs applied to clinical distributions of MD and progression led to earlier detection of early glaucoma progression.
- Open Access
Evaluating the clinical relevance and reliability of outer retinal band length on optical coherence tomography in retinal disease: a cross-sectional study
Objectives: Hyper-reflective outer retinal band (HORB) disruptions are reported across a range of retinal disease, yet a reliable, easily implemented assessment method and thorough evaluation of their association to retinal disease is lacking. The purpose of the study was to assess the reliability of using magnitude estimation to evaluate HORB length and determine its association to visual acuity and retinal disease. Design: Cross-sectional, retrospective study. Setting: Patients attending a secondary eye care clinic in Sydney, Australia. Participants: 2039 unique consecutive patients were screened for inclusion between 2 November and 18 January 2021, and 600 were included in the study population. Patients were included if they were referred from primary care, presented for an initial, comprehensive eye examination during the study period, imaged with optical coherence tomography during their visit and over 18 years of age. Primary outcome: Reliability of HORB length estimations and associations to clinical outcomes. Results: Intragrader (intraclass correlation coefficient, ICC fovea =0.81; ICC worst =0.91) and intergrader (ICC fovea =0.78–0.79; ICC worst =0.75–0.88) agreement of HORB length was good to excellent. HORB length was significantly associated with age (p<0.001, β=−0.22 to –0.24) and refractive error (p<0.001, β=0.12–0.16) at all B-scan locations. Visual acuity (p=0.001, β=−0.13) was associated with the primary outcome for foveal B-scans and eccentricity (p=0.002, β=−0.13) and device type (p=0.002, β=0.13) for non-foveal B-scans. Glaucoma was associated with HORB length on univariate analysis (p=0.05–0.06, β=−0.08); however, multivariate analysis revealed no significant association between HORB length and retinal disease. Conclusion: HORB length is reliably assessed using magnitude estimation and may be useful as a surrogate biomarker of visual acuity. Several factors affect HORB length estimations, which may contribute to the lack of association to retinal disease and highlights the need for covariable adjustment when examining HORB disruptions.
Open AccessEvaluating the clinical relevance and reliability of outer retinal band length on optical coherence tomography in retinal disease: a cross-sectional study
Objectives: Hyper-reflective outer retinal band (HORB) disruptions are reported across a range of retinal disease, yet a reliable, easily implemented assessment method and thorough evaluation of their association to retinal disease is lacking. The purpose of the study was to assess the reliability of using magnitude estimation to evaluate HORB length and determine its association to visual acuity and retinal disease. Design: Cross-sectional, retrospective study. Setting: Patients attending a secondary eye care clinic in Sydney, Australia. Participants: 2039 unique consecutive patients were screened for inclusion between 2 November and 18 January 2021, and 600 were included in the study population. Patients were included if they were referred from primary care, presented for an initial, comprehensive eye examination during the study period, imaged with optical coherence tomography during their visit and over 18 years of age. Primary outcome: Reliability of HORB length estimations and associations to clinical outcomes. Results: Intragrader (intraclass correlation coefficient, ICC fovea =0.81; ICC worst =0.91) and intergrader (ICC fovea =0.78–0.79; ICC worst =0.75–0.88) agreement of HORB length was good to excellent. HORB length was significantly associated with age (p<0.001, β=−0.22 to –0.24) and refractive error (p<0.001, β=0.12–0.16) at all B-scan locations. Visual acuity (p=0.001, β=−0.13) was associated with the primary outcome for foveal B-scans and eccentricity (p=0.002, β=−0.13) and device type (p=0.002, β=0.13) for non-foveal B-scans. Glaucoma was associated with HORB length on univariate analysis (p=0.05–0.06, β=−0.08); however, multivariate analysis revealed no significant association between HORB length and retinal disease. Conclusion: HORB length is reliably assessed using magnitude estimation and may be useful as a surrogate biomarker of visual acuity. Several factors affect HORB length estimations, which may contribute to the lack of association to retinal disease and highlights the need for covariable adjustment when examining HORB disruptions.
- 4 January 2022
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 105 (2) , 117-134
Ocular ischaemia: signs, symptoms, and clinical considerations for primary eye care practitioners
Ischaemic stroke is a major disease burden as well as a leading cause of death. Early signs of ischaemic stroke can manifest in the eye, placing primary eyecare practitioners in an important position to identify patients at risk of ischaemic stroke and initiate suitable referral pathways. The vascular supply to the brain is reviewed with reference to vision including the various retinal signs and ocular symptoms associated with transient ischaemic attacks and ischaemic stroke. Using a range of clinical cases, the diverse clinical presentations of retinal embolic events, as well as other forms of vascular occlusion, are highlighted and the underlying pathophysiology is discussed. A succinct scheme for the assessment and management of ischaemic events for primary eye care practitioners is provided.
- 4 January 2022
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 105 (2) , 117-134
Ocular ischaemia: signs, symptoms, and clinical considerations for primary eye care practitioners
Ischaemic stroke is a major disease burden as well as a leading cause of death. Early signs of ischaemic stroke can manifest in the eye, placing primary eyecare practitioners in an important position to identify patients at risk of ischaemic stroke and initiate suitable referral pathways. The vascular supply to the brain is reviewed with reference to vision including the various retinal signs and ocular symptoms associated with transient ischaemic attacks and ischaemic stroke. Using a range of clinical cases, the diverse clinical presentations of retinal embolic events, as well as other forms of vascular occlusion, are highlighted and the underlying pathophysiology is discussed. A succinct scheme for the assessment and management of ischaemic events for primary eye care practitioners is provided.
- 9 November 2021
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 105 (6) , 669-670
Response to re: clinical outcomes of the Centre for Eye Health: an intra-professional optometry-led collaborative eye care clinic in Australia
EDITOR: We thank Mathan and colleagues for their supportive comments on our recent work1 and for sharing their own interesting results2 examining the diagnostic accuracy of optometry referrals to h...
- 9 November 2021
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 105 (6) , 669-670
Response to re: clinical outcomes of the Centre for Eye Health: an intra-professional optometry-led collaborative eye care clinic in Australia
EDITOR: We thank Mathan and colleagues for their supportive comments on our recent work1 and for sharing their own interesting results2 examining the diagnostic accuracy of optometry referrals to h...