Hongquan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hongquan Li has a total of 158 co-authors. Here are the top co-authors by number of shared publications:
- Manu Prakash
Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
14 shared publications - Adam G. Larson
Stanford University
3 shared publications - Deepak Krishnamurthy
Department of Bioengineering, University of California , Berkeley, CA 94720
3 shared publications - Adam G. Larson
Department of Bioengineering, Stanford University
2 shared publications - Bryan Greenhouse
Department of Medicine, University of California, San Francisco, USA
2 shared publications Chew Chai
Department of Bioengineering, Stanford University
2 shared publications
Latest Publications
- Open Access
Fluid-Squid: DIY Multiplexed Imaging of Cells and Tissues
Recent advances in multiplexed single-cell characterization have revolutionized our insight into cell biology, but many available technologies remain limited by high costs or a lack of customizability. To address these challenges, we developed Fluid-Squid, a cost-effective, quantitative imaging platform that integrates automated fluidics to support customizable, do-it-yourself multiplexed imaging workflows. Using Fluid-Squid, we successfully imaged fresh frozen human intestinal tissues with a 36-plex oligonucleotide-barcoded antibody panel and further demonstrated the feasibility of lyophilizing such multiplexed panels. We also adapted existing multiplexed imaging workflows to characterize individual cells to identify immune cell populations, phenotype, and antigen-specific cells from mouse splenocytes and human peripheral blood mononuclear cells (PBMCs) with a 39-antibody panel. To further expand its utility, we developed a barcoding strategy that allows for the pooling and simultaneous staining of multiple samples, reducing time, costs, and batch effects in single-cell experiments. This approach facilitated rapid titration to optimize antibody concentrations and assess the impact of various blood preparation methods on cell type retention. Overall, our work provides a new open-source framework for automated fluidics and microscopy in a flexible, cost-effective platform, empowering adaptable multiplexed characterization of both single cells and tissues.
Open AccessFluid-Squid: DIY Multiplexed Imaging of Cells and Tissues
Recent advances in multiplexed single-cell characterization have revolutionized our insight into cell biology, but many available technologies remain limited by high costs or a lack of customizability. To address these challenges, we developed Fluid-Squid, a cost-effective, quantitative imaging platform that integrates automated fluidics to support customizable, do-it-yourself multiplexed imaging workflows. Using Fluid-Squid, we successfully imaged fresh frozen human intestinal tissues with a 36-plex oligonucleotide-barcoded antibody panel and further demonstrated the feasibility of lyophilizing such multiplexed panels. We also adapted existing multiplexed imaging workflows to characterize individual cells to identify immune cell populations, phenotype, and antigen-specific cells from mouse splenocytes and human peripheral blood mononuclear cells (PBMCs) with a 39-antibody panel. To further expand its utility, we developed a barcoding strategy that allows for the pooling and simultaneous staining of multiple samples, reducing time, costs, and batch effects in single-cell experiments. This approach facilitated rapid titration to optimize antibody concentrations and assess the impact of various blood preparation methods on cell type retention. Overall, our work provides a new open-source framework for automated fluidics and microscopy in a flexible, cost-effective platform, empowering adaptable multiplexed characterization of both single cells and tissues.
- Open Access
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (19) , 193201
Quantum States Imaging of Magnetic Field Contours Based on Autler-Townes Effect in Ytterbium Atoms
An intercombination transition in Yb enables a novel approach for rapidly imaging magnetic field variations with excellent spatial and temporal resolution and accuracy. This quantum imaging magnetometer reveals “dark stripes” that are contours of constant magnetic field visible by eye or capturable by standard cameras. These dark lines result from a combination of Autler-Townes splitting and the spatial Hanle effect in the S 0 1 − P 1 3 transition of Yb when driven by multiple strong coherent laser fields (carrier and AM/FM modulation sidebands of a single-mode 556 nm laser). We show good agreement between experimental data and our theoretical model for the closed, 4-level Zeeman shifted V system and demonstrate scalar and vector magnetic field measurements at video frame rates over spatial dimensions of 5 cm with 0.1 mm resolution. Additionally, the S 0 1 − P 1 3 transition allows for ∼ μ s response time and a large dynamic range (from microtesla to many tesla). Published by the American Physical Society 2025
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 134 (19) , 193201
Open AccessQuantum States Imaging of Magnetic Field Contours Based on Autler-Townes Effect in Ytterbium Atoms
An intercombination transition in Yb enables a novel approach for rapidly imaging magnetic field variations with excellent spatial and temporal resolution and accuracy. This quantum imaging magnetometer reveals “dark stripes” that are contours of constant magnetic field visible by eye or capturable by standard cameras. These dark lines result from a combination of Autler-Townes splitting and the spatial Hanle effect in the S 0 1 − P 1 3 transition of Yb when driven by multiple strong coherent laser fields (carrier and AM/FM modulation sidebands of a single-mode 556 nm laser). We show good agreement between experimental data and our theoretical model for the closed, 4-level Zeeman shifted V system and demonstrate scalar and vector magnetic field measurements at video frame rates over spatial dimensions of 5 cm with 0.1 mm resolution. Additionally, the S 0 1 − P 1 3 transition allows for ∼ μ s response time and a large dynamic range (from microtesla to many tesla). Published by the American Physical Society 2025
- Open Access
Octopi 2.0: Open and Scalable Microscopy Platform for AI-powered Diagnostic Applications
Access to quantitative, robust, and affordable diagnostic tools is essential to address the global burden of infectious diseases. While manual microscopy remains a cornerstone of diagnostic workflows due to its broad adaptability, it is labor-intensive and prone to human error. Recent advances in artificial intelligence (AI) and robotics offer opportunities to automate and enhance microscopy, enabling high-throughput, multi-disease diagnostics with minimal reliance on complex supply chains. However, current automated microscopy platforms are often costly and inflexible — barriers that are especially limiting in low-resource settings. Here we present Octopi 2.0, an open, highly configurable, general-purpose automated microscopy platform for a broad range of diagnostic applications, including sickle cell anemia and antibiotic resistance that we have reported recently. Applying Octopi to imaging malaria parasites with 4’,6-diamidino-2-phenylindole (DAPI) staining, we discovered a spectral shift in fluorescence emission that allows rapid screening of blood smears at low magnification with throughput on the order of 1 million blood cells per minute. We further developed image processing and deep learning-based segmentation and classification pipelines to enable real-time processing for malaria diagnosis. For real-world performance validation, we collected a data set of 213 clinical samples from Uganda and the United States with a total of 905 million red blood cells and around 1.4 million malaria parasites. Using a ResNet-18 model and only one round of retraining, the model is able to achieve on average less than 5 false positive parasites/µL and a per-parasite level false negative rate of less than 8% in our test dataset. This per-cell performance implies a limit of detection (LoD) around 12 parasites/µL, and we measured patient-level performance of > 97% specificity and sensitivity in our independent test data set of clinical samples from 73 patients/donors. As more data is collected in larger validation studies, we expect the robustness and performance of the model to continue to improve according to what we observe in our proof-of-concept experiments carried out in this study. With significant cost reduction in hardware compared to current automated microscopes and an open and versatile approach for tackling multiple diseases with standard glass slide-based sample preparation, we envision Octopi 2.0 to help enable the “app store” for equitable data-driven, AI-powered diagnostics of many diseases and conditions.
Open AccessOctopi 2.0: Open and Scalable Microscopy Platform for AI-powered Diagnostic Applications
Access to quantitative, robust, and affordable diagnostic tools is essential to address the global burden of infectious diseases. While manual microscopy remains a cornerstone of diagnostic workflows due to its broad adaptability, it is labor-intensive and prone to human error. Recent advances in artificial intelligence (AI) and robotics offer opportunities to automate and enhance microscopy, enabling high-throughput, multi-disease diagnostics with minimal reliance on complex supply chains. However, current automated microscopy platforms are often costly and inflexible — barriers that are especially limiting in low-resource settings. Here we present Octopi 2.0, an open, highly configurable, general-purpose automated microscopy platform for a broad range of diagnostic applications, including sickle cell anemia and antibiotic resistance that we have reported recently. Applying Octopi to imaging malaria parasites with 4’,6-diamidino-2-phenylindole (DAPI) staining, we discovered a spectral shift in fluorescence emission that allows rapid screening of blood smears at low magnification with throughput on the order of 1 million blood cells per minute. We further developed image processing and deep learning-based segmentation and classification pipelines to enable real-time processing for malaria diagnosis. For real-world performance validation, we collected a data set of 213 clinical samples from Uganda and the United States with a total of 905 million red blood cells and around 1.4 million malaria parasites. Using a ResNet-18 model and only one round of retraining, the model is able to achieve on average less than 5 false positive parasites/µL and a per-parasite level false negative rate of less than 8% in our test dataset. This per-cell performance implies a limit of detection (LoD) around 12 parasites/µL, and we measured patient-level performance of > 97% specificity and sensitivity in our independent test data set of clinical samples from 73 patients/donors. As more data is collected in larger validation studies, we expect the robustness and performance of the model to continue to improve according to what we observe in our proof-of-concept experiments carried out in this study. With significant cost reduction in hardware compared to current automated microscopes and an open and versatile approach for tackling multiple diseases with standard glass slide-based sample preparation, we envision Octopi 2.0 to help enable the “app store” for equitable data-driven, AI-powered diagnostics of many diseases and conditions.
- Open Access
Morphology-based classification of sickle cell disease and β-thalassemia using a low-cost automated microscope and machine learning
Sickle cell disease (SCD) and β-thalassemia are the most common monogenic diseases, disproportionately affecting low- and middle-income countries, where low-cost and accurate diagnostic tools are needed to reduce the global disease burden. Although the sickling test is commonly used to screen for the sickle mutation, it cannot distinguish between the asymptomatic sickle cell trait (SCT) and SCD, or identify β-thalassemia. Here, we enhanced the inexpensive sickling test using automated microscopy and morphology-based machine learning classification to detect SCD, trait conditions (SCT and β-thalassemia trait) and normal individuals with an overall area under receiver operating curve, sensitivity and specificity of 0.940 (95% confidence intervals: 0.938-0.942), 84.6% (84.2%-84.9%), and 92.3% (92.1%-92.4%), respectively. Notably, the sensitivity and specificity to detect severe disease (SCD) was over 97% and 98%, respectively, thus establishing a low-cost automated screening option for disease detection in low-resource settings. Furthermore, leveraging high-throughput microscopy, we generated an open-access dataset comprising over 300,000 images with 1.5 trillion segmented cells from 138 individuals in Canada and Nepal including individuals with sickle and/or β-thalassemia mutations, to accelerate further research.
Open AccessMorphology-based classification of sickle cell disease and β-thalassemia using a low-cost automated microscope and machine learning
Sickle cell disease (SCD) and β-thalassemia are the most common monogenic diseases, disproportionately affecting low- and middle-income countries, where low-cost and accurate diagnostic tools are needed to reduce the global disease burden. Although the sickling test is commonly used to screen for the sickle mutation, it cannot distinguish between the asymptomatic sickle cell trait (SCT) and SCD, or identify β-thalassemia. Here, we enhanced the inexpensive sickling test using automated microscopy and morphology-based machine learning classification to detect SCD, trait conditions (SCT and β-thalassemia trait) and normal individuals with an overall area under receiver operating curve, sensitivity and specificity of 0.940 (95% confidence intervals: 0.938-0.942), 84.6% (84.2%-84.9%), and 92.3% (92.1%-92.4%), respectively. Notably, the sensitivity and specificity to detect severe disease (SCD) was over 97% and 98%, respectively, thus establishing a low-cost automated screening option for disease detection in low-resource settings. Furthermore, leveraging high-throughput microscopy, we generated an open-access dataset comprising over 300,000 images with 1.5 trillion segmented cells from 138 individuals in Canada and Nepal including individuals with sickle and/or β-thalassemia mutations, to accelerate further research.
- Open Access
A genetic and microscopy toolkit for live imaging of whole-body regeneration in Macrostomum lignano
Summary: Live imaging of regenerative processes can reveal how animals restore their bodies after injury through a cascade of dynamic cellular events. Here, we present a comprehensive toolkit for live imaging of whole-body regeneration in the flatworm Macrostomum lignan o, including a high throughput cloning pipeline, targeted cellular ablation, and advanced microscopy solutions. Using tissue-specific reporter expression, we examine how various structures regenerate. Enabled by a custom, low-cost luminescence/fluorescence microscope, we overcome intense stress-induced autofluorescence to demonstrate the first application of genetic cellular ablation in flatworms to reveal the limited regenerative capacity of neurons and their essential role during wound-healing. Finally, we build a novel open-source tracking microscope to continuously image moving animals throughout the week-long process of regeneration, quantifying kinetics of wound healing, nerve cord repair, body regeneration, growth, and behavioral recovery. Our findings suggest that nerve cord reconnection operates independently from primary body axis re-establishment and other downstream regenerative processes.
Open AccessA genetic and microscopy toolkit for live imaging of whole-body regeneration in Macrostomum lignano
Summary: Live imaging of regenerative processes can reveal how animals restore their bodies after injury through a cascade of dynamic cellular events. Here, we present a comprehensive toolkit for live imaging of whole-body regeneration in the flatworm Macrostomum lignan o, including a high throughput cloning pipeline, targeted cellular ablation, and advanced microscopy solutions. Using tissue-specific reporter expression, we examine how various structures regenerate. Enabled by a custom, low-cost luminescence/fluorescence microscope, we overcome intense stress-induced autofluorescence to demonstrate the first application of genetic cellular ablation in flatworms to reveal the limited regenerative capacity of neurons and their essential role during wound-healing. Finally, we build a novel open-source tracking microscope to continuously image moving animals throughout the week-long process of regeneration, quantifying kinetics of wound healing, nerve cord repair, body regeneration, growth, and behavioral recovery. Our findings suggest that nerve cord reconnection operates independently from primary body axis re-establishment and other downstream regenerative processes.
- Open Access
MultiSero: An Open-Source Multiplex-ELISA Platform for Measuring Antibody Responses to Infection
A multiplexed enzyme-linked immunosorbent assay (ELISA) that simultaneously measures antibody binding to multiple antigens can extend the impact of serosurveillance studies, particularly if the assay approaches the simplicity, robustness, and accuracy of a conventional single-antigen ELISA. Here, we report on the development of multiSero, an open-source multiplex ELISA platform for measuring antibody responses to viral infection. Our assay consists of three parts: (1) an ELISA against an array of proteins in a 96-well format; (2) automated imaging of each well of the ELISA array using an open-source plate reader; and (3) automated measurement of optical densities for each protein within the array using an open-source analysis pipeline. We validated the platform by comparing antibody binding to Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) antigens in 217 human sera samples, showing high sensitivity (0.978), specificity (0.977), positive predictive value (0.978), and negative predictive value (0.977) for classifying seropositivity, a high correlation of multiSero determined antibody titers with commercially available SARS-CoV-2 antibody tests, and antigen-specific changes in antibody titer dynamics upon vaccination. The open-source format and accessibility of our multiSero platform can contribute to the adoption of multiplexed ELISA arrays for serosurveillance studies, for SARS-CoV-2 and other pathogens of significance.
Open AccessMultiSero: An Open-Source Multiplex-ELISA Platform for Measuring Antibody Responses to Infection
A multiplexed enzyme-linked immunosorbent assay (ELISA) that simultaneously measures antibody binding to multiple antigens can extend the impact of serosurveillance studies, particularly if the assay approaches the simplicity, robustness, and accuracy of a conventional single-antigen ELISA. Here, we report on the development of multiSero, an open-source multiplex ELISA platform for measuring antibody responses to viral infection. Our assay consists of three parts: (1) an ELISA against an array of proteins in a 96-well format; (2) automated imaging of each well of the ELISA array using an open-source plate reader; and (3) automated measurement of optical densities for each protein within the array using an open-source analysis pipeline. We validated the platform by comparing antibody binding to Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) antigens in 217 human sera samples, showing high sensitivity (0.978), specificity (0.977), positive predictive value (0.978), and negative predictive value (0.977) for classifying seropositivity, a high correlation of multiSero determined antibody titers with commercially available SARS-CoV-2 antibody tests, and antigen-specific changes in antibody titer dynamics upon vaccination. The open-source format and accessibility of our multiSero platform can contribute to the adoption of multiplexed ELISA arrays for serosurveillance studies, for SARS-CoV-2 and other pathogens of significance.
- Open Access
Inflation induced motility for long-distance vertical migration
The daily vertical migrations of plankton play a crucial role in shaping marine ecosystems and influencing global biogeochemical cycles. They also form the foundation of the largest daily biomass movement on Earth. Surprisingly, amongst this diverse group of organisms, some single cell protists transit these depths exceeding 50 meters without employing flagella or cilia, and the underlying mechanisms remain poorly understood. It has been previously proposed that this capability relies on the cell’s ability to regulate its internal density relative to seawater. Here, using Pyrocystis noctiluca as a model system, we demonstrate the primary mechanism for this density control is a rapid cellular inflation event, during which a single plankton cell expands its volume six-fold in less than 10 minutes. This self-regulated cellular inflation selectively imports fluid less dense than surrounding seawater, and can effectively sling-shot a cell and reverse sedimentation within minutes. This ability is made possible by a reticulated cytoplasmic architecture in Pyrocystis noctiluca that enables this rapid increase in overall cell volume without dilution of its cytoplasmic content. We further present a generalized mathematical framework that unifies cell cycle driven density regulation, stratified ecology, and associated cell behavior in the open ocean. Our study unveils an ingenious strategy employed by non-motile plankton to evade the gravitational sedimentation trap, highlighting how precise control of cell size was essential for survival in the ocean.
Open AccessInflation induced motility for long-distance vertical migration
The daily vertical migrations of plankton play a crucial role in shaping marine ecosystems and influencing global biogeochemical cycles. They also form the foundation of the largest daily biomass movement on Earth. Surprisingly, amongst this diverse group of organisms, some single cell protists transit these depths exceeding 50 meters without employing flagella or cilia, and the underlying mechanisms remain poorly understood. It has been previously proposed that this capability relies on the cell’s ability to regulate its internal density relative to seawater. Here, using Pyrocystis noctiluca as a model system, we demonstrate the primary mechanism for this density control is a rapid cellular inflation event, during which a single plankton cell expands its volume six-fold in less than 10 minutes. This self-regulated cellular inflation selectively imports fluid less dense than surrounding seawater, and can effectively sling-shot a cell and reverse sedimentation within minutes. This ability is made possible by a reticulated cytoplasmic architecture in Pyrocystis noctiluca that enables this rapid increase in overall cell volume without dilution of its cytoplasmic content. We further present a generalized mathematical framework that unifies cell cycle driven density regulation, stratified ecology, and associated cell behavior in the open ocean. Our study unveils an ingenious strategy employed by non-motile plankton to evade the gravitational sedimentation trap, highlighting how precise control of cell size was essential for survival in the ocean.
- 25 May 2022
- Published by Morressier GmbH
Yb atomic magnetometer with unique capabilities
Yb atomic magnetometer with unique capabilities |
- 25 May 2022
- Published by Morressier GmbH
Yb atomic magnetometer with unique capabilities
Yb atomic magnetometer with unique capabilities |
- Open Access
- 14 October 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-12
A microfluidic platform for highly parallel bite by bite profiling of mosquito-borne pathogen transmission
Mosquito bites transmit a number of pathogens via salivary droplets deposited during blood-feeding, resulting in potentially fatal diseases. Little is known about the genomic content of these nanodroplets, including the transmission dynamics of live pathogens. Here we introduce Vectorchip, a low-cost, scalable microfluidic platform enabling high-throughput molecular interrogation of individual mosquito bites. We introduce an ultra-thin PDMS membrane which acts as a biting interface to arrays of micro-wells. Freely-behaving mosquitoes deposit saliva droplets by biting into these micro-wells. By modulating membrane thickness, we observe species-dependent differences in mosquito biting capacity, utilizable for selective sample collection. We demonstrate RT-PCR and focus-forming assays on-chip to detect mosquito DNA, Zika virus RNA, as well as quantify infectious Mayaro virus particles transmitted from single mosquito bites. The Vectorchip presents a promising approach for single-bite-resolution laboratory and field characterization of vector-pathogen communities, and could serve as a powerful early warning sentinel for mosquito-borne diseases.
- 14 October 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-12
Open AccessA microfluidic platform for highly parallel bite by bite profiling of mosquito-borne pathogen transmission
Mosquito bites transmit a number of pathogens via salivary droplets deposited during blood-feeding, resulting in potentially fatal diseases. Little is known about the genomic content of these nanodroplets, including the transmission dynamics of live pathogens. Here we introduce Vectorchip, a low-cost, scalable microfluidic platform enabling high-throughput molecular interrogation of individual mosquito bites. We introduce an ultra-thin PDMS membrane which acts as a biting interface to arrays of micro-wells. Freely-behaving mosquitoes deposit saliva droplets by biting into these micro-wells. By modulating membrane thickness, we observe species-dependent differences in mosquito biting capacity, utilizable for selective sample collection. We demonstrate RT-PCR and focus-forming assays on-chip to detect mosquito DNA, Zika virus RNA, as well as quantify infectious Mayaro virus particles transmitted from single mosquito bites. The Vectorchip presents a promising approach for single-bite-resolution laboratory and field characterization of vector-pathogen communities, and could serve as a powerful early warning sentinel for mosquito-borne diseases.
- Open Access
multiSero: open multiplex-ELISA platform for analyzing antibody responses to SARS-CoV-2 infection
Serology has provided valuable diagnostic and epidemiological data on antibody responses to SARS-CoV-2 in diverse patient cohorts. Deployment of high content, multiplex serology platforms across the world, including in low and medium income countries, can accelerate longitudinal epidemiological surveys. Here we report multiSero, an open platform to enable multiplex serology with up to 48 antigens in a 96-well format. The platform consists of three components: ELISA-array of printed proteins, a commercial or home-built plate reader, and modular python software for automated analysis (pysero). We validate the platform by comparing antibody titers against the SARS-CoV-2 Spike, receptor binding domain (RBD), and nucleocapsid (N) in 114 sera from COVID-19 positive individuals and 87 pre-pandemic COVID-19 negative sera. We report data with both a commercial plate reader and an inexpensive, open plate reader (nautilus). Receiver operating characteristic (ROC) analysis of classification with single antigens shows that Spike and RBD classify positive and negative sera with the highest sensitivity at a given specificity. The platform distinguished positive sera from negative sera when the reactivity of the sera was equivalent to the binding of 1 ng mL −1 RBD-specific monoclonal antibody. We developed normalization and classification methods to pool antibody responses from multiple antigens and multiple experiments. Our results demonstrate a performant and accessible pipeline for multiplexed ELISA ready for multiple applications, including serosurveillance, identification of viral proteins that elicit antibody responses, differential diagnosis of circulating pathogens, and immune responses to vaccines.
Open AccessmultiSero: open multiplex-ELISA platform for analyzing antibody responses to SARS-CoV-2 infection
Serology has provided valuable diagnostic and epidemiological data on antibody responses to SARS-CoV-2 in diverse patient cohorts. Deployment of high content, multiplex serology platforms across the world, including in low and medium income countries, can accelerate longitudinal epidemiological surveys. Here we report multiSero, an open platform to enable multiplex serology with up to 48 antigens in a 96-well format. The platform consists of three components: ELISA-array of printed proteins, a commercial or home-built plate reader, and modular python software for automated analysis (pysero). We validate the platform by comparing antibody titers against the SARS-CoV-2 Spike, receptor binding domain (RBD), and nucleocapsid (N) in 114 sera from COVID-19 positive individuals and 87 pre-pandemic COVID-19 negative sera. We report data with both a commercial plate reader and an inexpensive, open plate reader (nautilus). Receiver operating characteristic (ROC) analysis of classification with single antigens shows that Spike and RBD classify positive and negative sera with the highest sensitivity at a given specificity. The platform distinguished positive sera from negative sera when the reactivity of the sera was equivalent to the binding of 1 ng mL −1 RBD-specific monoclonal antibody. We developed normalization and classification methods to pool antibody responses from multiple antigens and multiple experiments. Our results demonstrate a performant and accessible pipeline for multiplexed ELISA ready for multiple applications, including serosurveillance, identification of viral proteins that elicit antibody responses, differential diagnosis of circulating pathogens, and immune responses to vaccines.