Era Purwanto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Era Purwanto has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Abdillah Aziz Muntashir
Politeknik Astra
2 shared publications - Abdillah Aziz Muntashir
Politeknik Elektronika Negeri Surabaya
2 shared publications Bambang Sumantri
Department of Electrical Engineering, Electronic Engineering Polytechnic Institute of Surabaya, Surabaya, Indonesia
2 shared publicationsIndra Ferdiansyah
Politeknik Elektronika Negeri Surabaya
2 shared publications- Muhammad Rizani Rusli
Politeknik Elektronika Negeri Surabaya
2 shared publications - Ony Asrarul Qudsi
Politeknik Elektronika Negeri Surabaya, Indonesia
2 shared publications
Latest Publications
- Open Access
- 2 September 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 13-18
Bearing fault classification in induction motors using current spectrum analysis and artificial neural network
Introduction. Bearing faults in induction motors are one of the primary causes of performance degradation and unexpected failures in industrial systems. Early fault detection remains challenging because conventional protection systems generally respond only after severe damage occurs. In addition, motor current signals exhibit nonlinear and complex characteristics, requiring advanced analysis techniques for accurate fault identification. Problem. Existing fault diagnosis methods often suffer from limited classification accuracy, dependency on specific operating conditions, and insufficient integration between spectral feature extraction and adaptive classification techniques. Goal. To develop a non-invasive bearing fault classification method based on current spectrum analysis and artificial neural network (ANN) for induction motor condition monitoring. Methodology. The proposed method utilizes fast Fourier transform (FFT) to transform motor current signals from the time domain into the frequency domain for spectral feature extraction. The extracted features are then processed using principal component analysis (PCA) for dimensionality reduction before being used as inputs to the ANN classifier. Experimental testing is conducted under 3 bearing conditions, namely normal, 7-ball fault, and 6-ball fault conditions, using 50 datasets for each condition. Results. The results demonstrate that the proposed method successfully identifies bearing conditions with high classification accuracy and strong separation characteristics in the PCA space. FFT analysis also reveals consistent spectral changes corresponding to fault severity, particularly in sideband components and energy distribution patterns. Scientific novelty. This work integrates FFT-based current spectrum analysis, PCA-based feature reduction, and ANN classification into a unified non-invasive diagnosis framework for bearing fault detection. Practical value. The proposed approach provides a simple, adaptive, and reliable solution for early bearing fault detection without requiring additional mechanical sensors, making it suitable for industrial condition monitoring applications. References 32, tables 4, figures 7.
- 2 September 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 13-18
Open AccessBearing fault classification in induction motors using current spectrum analysis and artificial neural network
Introduction. Bearing faults in induction motors are one of the primary causes of performance degradation and unexpected failures in industrial systems. Early fault detection remains challenging because conventional protection systems generally respond only after severe damage occurs. In addition, motor current signals exhibit nonlinear and complex characteristics, requiring advanced analysis techniques for accurate fault identification. Problem. Existing fault diagnosis methods often suffer from limited classification accuracy, dependency on specific operating conditions, and insufficient integration between spectral feature extraction and adaptive classification techniques. Goal. To develop a non-invasive bearing fault classification method based on current spectrum analysis and artificial neural network (ANN) for induction motor condition monitoring. Methodology. The proposed method utilizes fast Fourier transform (FFT) to transform motor current signals from the time domain into the frequency domain for spectral feature extraction. The extracted features are then processed using principal component analysis (PCA) for dimensionality reduction before being used as inputs to the ANN classifier. Experimental testing is conducted under 3 bearing conditions, namely normal, 7-ball fault, and 6-ball fault conditions, using 50 datasets for each condition. Results. The results demonstrate that the proposed method successfully identifies bearing conditions with high classification accuracy and strong separation characteristics in the PCA space. FFT analysis also reveals consistent spectral changes corresponding to fault severity, particularly in sideband components and energy distribution patterns. Scientific novelty. This work integrates FFT-based current spectrum analysis, PCA-based feature reduction, and ANN classification into a unified non-invasive diagnosis framework for bearing fault detection. Practical value. The proposed approach provides a simple, adaptive, and reliable solution for early bearing fault detection without requiring additional mechanical sensors, making it suitable for industrial condition monitoring applications. References 32, tables 4, figures 7.
- Open Access
- 1 June 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 17 (2)
Smart adaptive CC-CV charger with PSO-accelerated load identification and fuzzy duty-cycle regulation
This paper presents an adaptive constant-current/constant-voltage (CC-CV) charger architecture, meticulously designed to address a key challenge in smart chargers. This challenge involves recognizing various battery types and applying the appropriate charging profile expeditiously, without requiring user intervention. The system integrates a particle swarm optimization (PSO) algorithm for ultra-fast load identification with a Mamdani-type fuzzy logic controller for precise duty cycle regulation. The PSO mechanism is capable of determining the optimal initial duty cycle in less than 500 milliseconds. Subsequent to this preliminary initiation, the fuzzy logic controller guarantees the effectiveness of current and voltage regulation during the charging phases. The simulation results obtained from this study validate the system's robustness, as evidenced by the consistent maintenance of voltage ripple below ±0.06 V and current ripple below ±0.04 A. These findings demonstrate the efficacy of the proposed approach in achieving fast, stable, and safe multi-load battery charging. The chemistry-agnostic design of the battery pack is extendable to any battery pack following the CC-CV paradigm, making it highly suitable for practical applications that demand flexibility and high reliability.
- 1 June 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 17 (2)
Open AccessSmart adaptive CC-CV charger with PSO-accelerated load identification and fuzzy duty-cycle regulation
This paper presents an adaptive constant-current/constant-voltage (CC-CV) charger architecture, meticulously designed to address a key challenge in smart chargers. This challenge involves recognizing various battery types and applying the appropriate charging profile expeditiously, without requiring user intervention. The system integrates a particle swarm optimization (PSO) algorithm for ultra-fast load identification with a Mamdani-type fuzzy logic controller for precise duty cycle regulation. The PSO mechanism is capable of determining the optimal initial duty cycle in less than 500 milliseconds. Subsequent to this preliminary initiation, the fuzzy logic controller guarantees the effectiveness of current and voltage regulation during the charging phases. The simulation results obtained from this study validate the system's robustness, as evidenced by the consistent maintenance of voltage ripple below ±0.06 V and current ripple below ±0.04 A. These findings demonstrate the efficacy of the proposed approach in achieving fast, stable, and safe multi-load battery charging. The chemistry-agnostic design of the battery pack is extendable to any battery pack following the CC-CV paradigm, making it highly suitable for practical applications that demand flexibility and high reliability.
- Open Access
- 27 April 2026
- Published by Politeknik Negeri Balikpapan in JTT (Jurnal Teknologi Terpadu)
- Vol. 14 (1) , 108-117
Commutation Performance Enhancement of Sensorless BLDC Motor Using Finite Impulse Response Filtering in Back-EMF Detection
Sensorless Brushless Direct Current (BLDC) motors are widely used in industrial applications due to their high efficiency and low maintenance requirements. However, commutation based on Back-Electromotive Force (Back-EMF) zero-crossing detection is highly susceptible to noise, leading to commutation timing inaccuracies. This paper proposes an improvement in sensorless BLDC motor commutation performance through the application of a Finite Impulse Response (FIR) digital filter to the Back-EMF detection signal. The FIR filter is designed to attenuate high-frequency harmonic components without compromising system stability. The proposed method is implemented on a three-phase inverter system employing six-step commutation controlled by a microcontroller. Simulation results indicate that the dominant noise frequency in the Back-EMF signal is reduced from 347.6 Hz to 212.5 Hz after filtering. Furthermore, hardware experimental results demonstrate a reduction in disturbance frequency from 317.23 Hz to 265.43 Hz. The application of the FIR filter improves the reliability of zero-crossing detection and enhances commutation timing accuracy compared to an unfiltered system. These results confirm that the proposed approach is effective in improving the commutation performance of sensorless BLDC motors based on Back-EMF detection.
- 27 April 2026
- Published by Politeknik Negeri Balikpapan in JTT (Jurnal Teknologi Terpadu)
- Vol. 14 (1) , 108-117
Open AccessCommutation Performance Enhancement of Sensorless BLDC Motor Using Finite Impulse Response Filtering in Back-EMF Detection
Sensorless Brushless Direct Current (BLDC) motors are widely used in industrial applications due to their high efficiency and low maintenance requirements. However, commutation based on Back-Electromotive Force (Back-EMF) zero-crossing detection is highly susceptible to noise, leading to commutation timing inaccuracies. This paper proposes an improvement in sensorless BLDC motor commutation performance through the application of a Finite Impulse Response (FIR) digital filter to the Back-EMF detection signal. The FIR filter is designed to attenuate high-frequency harmonic components without compromising system stability. The proposed method is implemented on a three-phase inverter system employing six-step commutation controlled by a microcontroller. Simulation results indicate that the dominant noise frequency in the Back-EMF signal is reduced from 347.6 Hz to 212.5 Hz after filtering. Furthermore, hardware experimental results demonstrate a reduction in disturbance frequency from 317.23 Hz to 265.43 Hz. The application of the FIR filter improves the reliability of zero-crossing detection and enhances commutation timing accuracy compared to an unfiltered system. These results confirm that the proposed approach is effective in improving the commutation performance of sensorless BLDC motors based on Back-EMF detection.
- 8 July 2024
- Published by Springer Nature in Journal of Power Electronics
- Vol. 24 (11) , 1791-1801
Performance improvement of induction motor drives in low-speed operation using gray wolf optimizer based on IFOC
- 8 July 2024
- Published by Springer Nature in Journal of Power Electronics
- Vol. 24 (11) , 1791-1801
Performance improvement of induction motor drives in low-speed operation using gray wolf optimizer based on IFOC
- Open Access
- 16 February 2024
- Published by Atlantis Press SARL
- p. 1175-1187
Revolutionizing Electric Vehicle Charging: The Interleaved Buck Converter Approach
- 16 February 2024
- Published by Atlantis Press SARL
- p. 1175-1187
Open AccessRevolutionizing Electric Vehicle Charging: The Interleaved Buck Converter Approach
- Open Access
- 25 July 2023
- Published by Institut Teknologi Nasional, Bandung in ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika
- Vol. 11 (3) , 649
Kendali Motor Sangkar Tupai 3 Phasa berbasis Indirect Field Oriented Control (IFOC) dengan PID Controller
ABSTRAKDunia industri sekarang banyak menggunakan motor sangkar tupai 3 phasa, karena memiliki kehandalan yang tinggi, tetapi motor sangkar tupai 3 phasa mempunyai beberapa kekurangan yaitu sukar untuk menjaga pada kecepatan konstan pada saat adanya perubahan beban, serta pengaturan kecepatan yang sulit dilakukan karena sistemnya yang coupled. Dengan melakukan metode vector control yang bebasis pada Indirect Field Oriented Control (IFOC), sehingga pengendalian motor sangkar tupai 3 phasa dapat dilakukan seperti pada DC motor penguat terpisah. PID controller digunakan untuk pengaturan kecepatan, dimana parameter PID didapatkan menggunakan Ziegler Nichols, serta hasil yang didapat adalah luaran kecepatan dengan risetime cepat dan error steady state kecil. Simulasi yang dilakukan telah dilakukan dengan menggunakan LabView, didapatkan respons waktu naik 1.132 ms, waktu penyelesaian 9,91 ms dan error steady 0,4% dengan set poin 500 Rpm. Serta waktu recovery sebesar 4.9 ms pada set poin 300 Rpm.Kata kunci: vector control, motor sangkar tupai 3 phasa, motor DC, coupled, decoupled ABSTRACTThree-phase squirrel cage motors are used today in many industries because of their high reliability. The downside is that speeds are difficult to adjust when connecting to a system. Three-phase cage motor control can be implemented as a discrete DC motor amplifier by using a vector control scheme based on Indirect Field Oriented Control (IFOC), for the speed control the PID controller is used in this system, PID parameters are obtained using Ziegler Nichols, and the result is an output speed , the fast rise time and low stability error. The simulation was run using LabView and had a time response 1.132 ms, a time stedy state is 9.91 ms, and a error flat is 0.4% at a setpoint of 500rpm. So does the time recovery of 4.9ms in speed 300 rpm setpoint.Keywords: vector control, 3-phase squirrel cage, DC motor, coupled, decoupled
- 25 July 2023
- Published by Institut Teknologi Nasional, Bandung in ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika
- Vol. 11 (3) , 649
Open AccessKendali Motor Sangkar Tupai 3 Phasa berbasis Indirect Field Oriented Control (IFOC) dengan PID Controller
ABSTRAKDunia industri sekarang banyak menggunakan motor sangkar tupai 3 phasa, karena memiliki kehandalan yang tinggi, tetapi motor sangkar tupai 3 phasa mempunyai beberapa kekurangan yaitu sukar untuk menjaga pada kecepatan konstan pada saat adanya perubahan beban, serta pengaturan kecepatan yang sulit dilakukan karena sistemnya yang coupled. Dengan melakukan metode vector control yang bebasis pada Indirect Field Oriented Control (IFOC), sehingga pengendalian motor sangkar tupai 3 phasa dapat dilakukan seperti pada DC motor penguat terpisah. PID controller digunakan untuk pengaturan kecepatan, dimana parameter PID didapatkan menggunakan Ziegler Nichols, serta hasil yang didapat adalah luaran kecepatan dengan risetime cepat dan error steady state kecil. Simulasi yang dilakukan telah dilakukan dengan menggunakan LabView, didapatkan respons waktu naik 1.132 ms, waktu penyelesaian 9,91 ms dan error steady 0,4% dengan set poin 500 Rpm. Serta waktu recovery sebesar 4.9 ms pada set poin 300 Rpm.Kata kunci: vector control, motor sangkar tupai 3 phasa, motor DC, coupled, decoupled ABSTRACTThree-phase squirrel cage motors are used today in many industries because of their high reliability. The downside is that speeds are difficult to adjust when connecting to a system. Three-phase cage motor control can be implemented as a discrete DC motor amplifier by using a vector control scheme based on Indirect Field Oriented Control (IFOC), for the speed control the PID controller is used in this system, PID parameters are obtained using Ziegler Nichols, and the result is an output speed , the fast rise time and low stability error. The simulation was run using LabView and had a time response 1.132 ms, a time stedy state is 9.91 ms, and a error flat is 0.4% at a setpoint of 500rpm. So does the time recovery of 4.9ms in speed 300 rpm setpoint.Keywords: vector control, 3-phase squirrel cage, DC motor, coupled, decoupled
- 30 January 2022
- Published by Universitas Pendidikan Ganesha in Jurnal Pendidikan Teknologi dan Kejuruan
- Vol. 19 (1) , 45-55
PENGENDALIAN MOTOR INDUKSI 3 FASA DENGAN BEBAN DINAMIS KONTROL PID FUZZY MENGGUNAKAN METODE FOC-TAK LANGSUNG (INDIRECT FIELD ORIENTED CONTROL) PADA LABVIEW
This research includes the design of a PID speed control simulation combined with Fuzzy Logic Control as a control, and increasing the speed performance of an induction motor in LabView. The control method used is a vector control induction motor, namely Field Oriented Control. This method can set up an induction motor as easily as a separate amplifier DC motor. Fuzzy Logic Control with its advantages acts as a scheduler for the PID value with the advantage of increasing the dynamic performance of the induction motor against changes in load and speed changes. From several simulations carried out on LabView with 5nm and 9nm dynamic loads using the FOC method, the average risetime result is 80% fast. When testing the dynamic load control performance, the results of the PID-Fuzzy method are better than conventional PID, especially at high motor speeds and nominal loads. In dynamic load testing, PID-Fuzzy is also better than conventional PID. With a conventional PID controller when the load is 9nm with a set point of 1500 RPM, the risetime is 10.0 ms and the steady error is 1.8%. With the PID-Fuzzy method, a risetime of 6.6 ms is obtained and a steady error of 0.7.
- 30 January 2022
- Published by Universitas Pendidikan Ganesha in Jurnal Pendidikan Teknologi dan Kejuruan
- Vol. 19 (1) , 45-55
PENGENDALIAN MOTOR INDUKSI 3 FASA DENGAN BEBAN DINAMIS KONTROL PID FUZZY MENGGUNAKAN METODE FOC-TAK LANGSUNG (INDIRECT FIELD ORIENTED CONTROL) PADA LABVIEW
This research includes the design of a PID speed control simulation combined with Fuzzy Logic Control as a control, and increasing the speed performance of an induction motor in LabView. The control method used is a vector control induction motor, namely Field Oriented Control. This method can set up an induction motor as easily as a separate amplifier DC motor. Fuzzy Logic Control with its advantages acts as a scheduler for the PID value with the advantage of increasing the dynamic performance of the induction motor against changes in load and speed changes. From several simulations carried out on LabView with 5nm and 9nm dynamic loads using the FOC method, the average risetime result is 80% fast. When testing the dynamic load control performance, the results of the PID-Fuzzy method are better than conventional PID, especially at high motor speeds and nominal loads. In dynamic load testing, PID-Fuzzy is also better than conventional PID. With a conventional PID controller when the load is 9nm with a set point of 1500 RPM, the risetime is 10.0 ms and the steady error is 1.8%. With the PID-Fuzzy method, a risetime of 6.6 ms is obtained and a steady error of 0.7.
- Open Access
- 24 May 2021
- Published by Universitas Muhammadiyah Magelang in Automotive Experiences
- Vol. 4 (2) , 83-96
Static and Dynamic Performance of Vector Control on Induction Motor with PID Controller: An Investigation on LabVIEW
A three-phase induction motor is often used in everyday life because of its high reliability. However, it is associated with some disadvantages, including difficulties in maintaining constant speed during load changes and speed regulation due to the decoupled system. Therefore, this study aims to adjust the three-phase induction motor control to become a separate amplifier DC motor by setting the vector control using the IFOC method, which changes the coupled to the decoupled system. The speed settings are equipped with a PID controller where its parameters, which are obtained using Ziegler Nichols, produce speed output with fast research time and small steady-state errors. This research was conducted to observe and analyze the performance of a controller based on the IFOC approach with a PID controller at speed differences, with static and dynamic conditions in the entire speed working area. In the first stage of the research, simulation is carried out with static conditions, namely changes in speed variations throughout the work area (low speed to high speed), the next stage is a simulation with dynamic conditions, which is to provide changes in the value of the load torque when the system is operating. The simulation result carried out with LabVIEW shows a response time of 1.13 ms, a settling time of 9.9 ms, and a steady error of 0.4% at the 500 Rpm set point. It also indicated dynamic characteristics with a recovery time of 4.9 ms at the 300 Rpm set point. When operated at low speed, IFOC with PID controller has a stable response. But In dynamic conditions, the use of a PID controller is considered unsuitable. This is because the PID controller is less fast and less robust in responding to the system when conditions change in the value of the load torque.
- 24 May 2021
- Published by Universitas Muhammadiyah Magelang in Automotive Experiences
- Vol. 4 (2) , 83-96
Open AccessStatic and Dynamic Performance of Vector Control on Induction Motor with PID Controller: An Investigation on LabVIEW
A three-phase induction motor is often used in everyday life because of its high reliability. However, it is associated with some disadvantages, including difficulties in maintaining constant speed during load changes and speed regulation due to the decoupled system. Therefore, this study aims to adjust the three-phase induction motor control to become a separate amplifier DC motor by setting the vector control using the IFOC method, which changes the coupled to the decoupled system. The speed settings are equipped with a PID controller where its parameters, which are obtained using Ziegler Nichols, produce speed output with fast research time and small steady-state errors. This research was conducted to observe and analyze the performance of a controller based on the IFOC approach with a PID controller at speed differences, with static and dynamic conditions in the entire speed working area. In the first stage of the research, simulation is carried out with static conditions, namely changes in speed variations throughout the work area (low speed to high speed), the next stage is a simulation with dynamic conditions, which is to provide changes in the value of the load torque when the system is operating. The simulation result carried out with LabVIEW shows a response time of 1.13 ms, a settling time of 9.9 ms, and a steady error of 0.4% at the 500 Rpm set point. It also indicated dynamic characteristics with a recovery time of 4.9 ms at the 300 Rpm set point. When operated at low speed, IFOC with PID controller has a stable response. But In dynamic conditions, the use of a PID controller is considered unsuitable. This is because the PID controller is less fast and less robust in responding to the system when conditions change in the value of the load torque.
- Open Access
- 22 January 2021
- Published by Institut Teknologi Nasional, Bandung in ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika
- Vol. 9 (1) , 31
Optimasi Fuzzy Supervisory Control pada Performa Matrix Converter Drive 3x3 di Empat Kuadran Operasi
ABSTRAKTeknologi pengemudian motor dengan efisiensi tinggi serta untuk mencapai empat kuadran operasi menjadi perhatian pada bidang pengemudian elektrik. Matrix converter menjadi alternatif utama konverter drive motor karena keunggulan – keunggulannya. Walaupun matrix converter sebagai drive motor mempunyai kompleksitas tinggi, namun dengan dikombinasikan teknik Indirect Space Vector Modulation (ISVM) dapat menghasilkan kepresisian lebar pulsa modulasi (PWM). Untuk pengendali sistem, diterapkan Fuzzy Supervisory Control (FSC), yang merupakan kendali gabungan, agar kecepatan referensi bisa tercapai. FSC dibandingkan dengan kendali konvensional (PI control) untuk membuktikan keoptimalan performa sistem yang diusulkan. Parameter performa sistem dan Total Harmonic Distortion (THD) dianalisis lebih lanjut. Hasil simulasi menunjukkan bahwa sistem yang diusulkan dapat mencapai Error Steady state (ESS) 0% dan THD lebih kecil.Kata kunci: Matrix converter, ISVM, FSC, motor induksi. ABSTRACTMotor-driving technology with high efficiency and to achieve four quadrants of operation is a concern in the area of electric steering. Matrix converter is the main alternative for motor drive converters because of its advantages. Although the matrix converter as a motor drive has a high complexity, combined with the Indirect Space Vector Modulation (ISVM) technique can produce precision pulse width modulation (PWM). For the system controller, Fuzzy Supervisory Control (FSC) is applied, which is a combined control, so that the reference speed can be achieved. FSC is compared with conventional control (PI control) to prove the optimization of the proposed system performance. System performance parameters and Total Harmonic Distortion (THD) are further analyzed. Simulation results show that the proposed system can reach 0% Error Steady State (ESS) and smaller THD.Keywords: Matrix converter, ISVM, FSC, induction motor.
- 22 January 2021
- Published by Institut Teknologi Nasional, Bandung in ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika
- Vol. 9 (1) , 31
Open AccessOptimasi Fuzzy Supervisory Control pada Performa Matrix Converter Drive 3x3 di Empat Kuadran Operasi
ABSTRAKTeknologi pengemudian motor dengan efisiensi tinggi serta untuk mencapai empat kuadran operasi menjadi perhatian pada bidang pengemudian elektrik. Matrix converter menjadi alternatif utama konverter drive motor karena keunggulan – keunggulannya. Walaupun matrix converter sebagai drive motor mempunyai kompleksitas tinggi, namun dengan dikombinasikan teknik Indirect Space Vector Modulation (ISVM) dapat menghasilkan kepresisian lebar pulsa modulasi (PWM). Untuk pengendali sistem, diterapkan Fuzzy Supervisory Control (FSC), yang merupakan kendali gabungan, agar kecepatan referensi bisa tercapai. FSC dibandingkan dengan kendali konvensional (PI control) untuk membuktikan keoptimalan performa sistem yang diusulkan. Parameter performa sistem dan Total Harmonic Distortion (THD) dianalisis lebih lanjut. Hasil simulasi menunjukkan bahwa sistem yang diusulkan dapat mencapai Error Steady state (ESS) 0% dan THD lebih kecil.Kata kunci: Matrix converter, ISVM, FSC, motor induksi. ABSTRACTMotor-driving technology with high efficiency and to achieve four quadrants of operation is a concern in the area of electric steering. Matrix converter is the main alternative for motor drive converters because of its advantages. Although the matrix converter as a motor drive has a high complexity, combined with the Indirect Space Vector Modulation (ISVM) technique can produce precision pulse width modulation (PWM). For the system controller, Fuzzy Supervisory Control (FSC) is applied, which is a combined control, so that the reference speed can be achieved. FSC is compared with conventional control (PI control) to prove the optimization of the proposed system performance. System performance parameters and Total Harmonic Distortion (THD) are further analyzed. Simulation results show that the proposed system can reach 0% Error Steady State (ESS) and smaller THD.Keywords: Matrix converter, ISVM, FSC, induction motor.
- Open Access
- 5 November 2020
- Published by Center for Research and Community Service at the State Polytechnic of Samarinda in PoliGrid
- Vol. 1 (2) , 49-54
Rancang Bangun Buck-Boost Converter Pada Sistem Charging Baterai dengan Sumber Solar Cell Menggunakan Kontrol PI pada Uninterruptible Power Supply (UPS) Offline untuk Aplikasi Beban Rumah Tangga
Kasus pemadaman listrik bergilir sudah menjadi masalah umum di Indonesia. Kebutuhan listrik semakin memuncak karena penggunaan energi listrik dapat menghidupkan berbagai peralatan rumah tangga dan industri. Saat ini, banyak terjadi pemadaman listrik secara bergilir karena kapasitas beban sudah melebihi kapasitas yang sudah ditentukan. Akibatnya, pasokan energi listrik menjadi tidak stabil, sehinga berdampak pada peralatan listrik rumah tangga. Akibat pemadaman listrik yang tidak menentu maka digunakan pemasok cadanan yang dapat bekerja ketika sumber daya utama tidak aktif atau disebut UPS (Uninterruptible Power Supply). UPS dapat menjadi energi cadangan listrik sementara pada saat terjadi pemadaman listrik sehina mengurangi dampak pada peralatan listrik rumah tanggaPada perancangan sistem ini, digunakan sumber solar cell 300WP(watt peak) yang digunakan untuk proses pengisian baterai 48V DC 45Ah dengan menggunakan buck-boost converter. Ketika sumber utama PLN tidak aktif ATS(Automatic Transfer Switch) secara otomatis akan memindahkan catu daya dari baterai. Dari sumber baterai digunakan inverter satu fasa untuk mencatu beban rumah tangga sebesar 50W 220V AC.
- 5 November 2020
- Published by Center for Research and Community Service at the State Polytechnic of Samarinda in PoliGrid
- Vol. 1 (2) , 49-54
Open AccessRancang Bangun Buck-Boost Converter Pada Sistem Charging Baterai dengan Sumber Solar Cell Menggunakan Kontrol PI pada Uninterruptible Power Supply (UPS) Offline untuk Aplikasi Beban Rumah Tangga
Kasus pemadaman listrik bergilir sudah menjadi masalah umum di Indonesia. Kebutuhan listrik semakin memuncak karena penggunaan energi listrik dapat menghidupkan berbagai peralatan rumah tangga dan industri. Saat ini, banyak terjadi pemadaman listrik secara bergilir karena kapasitas beban sudah melebihi kapasitas yang sudah ditentukan. Akibatnya, pasokan energi listrik menjadi tidak stabil, sehinga berdampak pada peralatan listrik rumah tangga. Akibat pemadaman listrik yang tidak menentu maka digunakan pemasok cadanan yang dapat bekerja ketika sumber daya utama tidak aktif atau disebut UPS (Uninterruptible Power Supply). UPS dapat menjadi energi cadangan listrik sementara pada saat terjadi pemadaman listrik sehina mengurangi dampak pada peralatan listrik rumah tanggaPada perancangan sistem ini, digunakan sumber solar cell 300WP(watt peak) yang digunakan untuk proses pengisian baterai 48V DC 45Ah dengan menggunakan buck-boost converter. Ketika sumber utama PLN tidak aktif ATS(Automatic Transfer Switch) secara otomatis akan memindahkan catu daya dari baterai. Dari sumber baterai digunakan inverter satu fasa untuk mencatu beban rumah tangga sebesar 50W 220V AC.