Ehsaneh Daghigh Ahmadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ehsaneh Daghigh Ahmadi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Muhammad Munem Ali
Centre for Nanohealth, College of Engineering, Swansea University, Swansea SA2 8PP, UK
3 shared publications - Owen James Guy
Swansea University
3 shared publications - Ffion Walters
Centre for Nanohealth, College of Engineering, Swansea University, Swansea SA2 8PP, UK
2 shared publications - Gregory Burwell
Centre for Integrative Semiconductor Materials Department of Physics Swansea University Bay Campus Fabian Way Swansea SA1 8EN UK
2 shared publications - Jacob John Mitchell
Centre for Nanohealth, College of Engineering, Swansea University, Swansea SA2 8PP, UK
2 shared publications - Anitha Devadoss
Institute of Biological Chemistry Biophysics & Bioengineering School of Engineering & Physical Sciences Riccarton Campus Heriot‐Watt University Edinburgh Scotland UK
1 shared publication
Latest Publications
- Open Access
- 22 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4254
Biophotonics in Dentistry
The aim of this review paper is to concentrate on the use and application of photonics in dentistry. More than one hundred review and research articles were comprehensively analysed in terms of applications of photonics in dentistry, including surgical applications, as well as dental biomaterials, diagnosis and treatments. In biomedical engineering, various fields, such as biology, chemistry, material and physics, come together in to tackle a disease/disorder either as a diagnostic tool or an option for treatment. Engineers believe that biophotonics is the application of photonics in medicine, whereas photonics is simply a technology for creating and connecting packets of light energy, known as photons. This review paper provides a comprehensive discussion of its main elements, such as photoelasticity, interferometry techniques, optical coherence tomography, different types of lasers, carbon nanotubes, graphene and quantum dots.
- 22 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (9) , 4254
Open AccessBiophotonics in Dentistry
The aim of this review paper is to concentrate on the use and application of photonics in dentistry. More than one hundred review and research articles were comprehensively analysed in terms of applications of photonics in dentistry, including surgical applications, as well as dental biomaterials, diagnosis and treatments. In biomedical engineering, various fields, such as biology, chemistry, material and physics, come together in to tackle a disease/disorder either as a diagnostic tool or an option for treatment. Engineers believe that biophotonics is the application of photonics in medicine, whereas photonics is simply a technology for creating and connecting packets of light energy, known as photons. This review paper provides a comprehensive discussion of its main elements, such as photoelasticity, interferometry techniques, optical coherence tomography, different types of lasers, carbon nanotubes, graphene and quantum dots.
- Open Access
- 20 August 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (8) , 2121
Application of Molecular Vapour Deposited Al2O3 for Graphene-Based Biosensor Passivation and Improvements in Graphene Device Homogeneity
Graphene-based point-of-care (PoC) and chemical sensors can be fabricated using photolithographic processes at wafer-scale. However, these approaches are known to leave polymer residues on the graphene surface, which are difficult to remove completely. In addition, graphene growth and transfer processes can introduce defects into the graphene layer. Both defects and resist contamination can affect the homogeneity of graphene-based PoC sensors, leading to inconsistent device performance and unreliable sensing. Sensor reliability is also affected by the harsh chemical environments used for chemical functionalisation of graphene PoC sensors, which can degrade parts of the sensor device. Therefore, a reliable, wafer-scale method of passivation, which isolates the graphene from the rest of the device, protecting the less robust device features from any aggressive chemicals, must be devised. This work covers the application of molecular vapour deposition technology to create a dielectric passivation film that protects graphene-based biosensing devices from harsh chemicals. We utilise a previously reported “healing effect” of Al2O3 on graphene to reduce photoresist residue from the graphene surface and reduce the prevalence of graphene defects to improve graphene device homogeneity. The improvement in device consistency allows for more reliable, homogeneous graphene devices, that can be fabricated at wafer-scale for sensing and biosensing applications.
- 20 August 2021
- Published by MDPI AG in Nanomaterials
- Vol. 11 (8) , 2121
Open AccessApplication of Molecular Vapour Deposited Al2O3 for Graphene-Based Biosensor Passivation and Improvements in Graphene Device Homogeneity
Graphene-based point-of-care (PoC) and chemical sensors can be fabricated using photolithographic processes at wafer-scale. However, these approaches are known to leave polymer residues on the graphene surface, which are difficult to remove completely. In addition, graphene growth and transfer processes can introduce defects into the graphene layer. Both defects and resist contamination can affect the homogeneity of graphene-based PoC sensors, leading to inconsistent device performance and unreliable sensing. Sensor reliability is also affected by the harsh chemical environments used for chemical functionalisation of graphene PoC sensors, which can degrade parts of the sensor device. Therefore, a reliable, wafer-scale method of passivation, which isolates the graphene from the rest of the device, protecting the less robust device features from any aggressive chemicals, must be devised. This work covers the application of molecular vapour deposition technology to create a dielectric passivation film that protects graphene-based biosensing devices from harsh chemicals. We utilise a previously reported “healing effect” of Al2O3 on graphene to reduce photoresist residue from the graphene surface and reduce the prevalence of graphene defects to improve graphene device homogeneity. The improvement in device consistency allows for more reliable, homogeneous graphene devices, that can be fabricated at wafer-scale for sensing and biosensing applications.
- Open Access
- 8 July 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (7) , 174
Graphene Bioelectronic Nose for the Detection of Odorants with Human Olfactory Receptor 2AG1
A real-time sensor for the detection of amyl butyrate (AB) utilising human olfactory receptor 2AG1 (OR2AG1), a G-protein coupled receptor (GPCR) consisting of seven transmembrane domains, immobilized onto a graphene resistor is demonstrated. Using CVD graphene as the sensor platform, allows greater potential for more sensitive detection than similar sensors based on carbon nanotubes, gold or graphene oxide platforms. A specific graphene resistor sensor was fabricated and modified via non-covalent π–π stacking of 1,5 diaminonaphthalene (DAN) onto the graphene channel, and subsequent anchoring of the OR2AG1 receptor to the DAN molecule using glutaraldehyde coupling. Binding between the target odorant, amyl butyrate, and the OR2AG1 receptor protein generated a change in resistance of the graphene resistor sensor. The functionalized graphene resistor sensors exhibited a linear sensor response between 0.1–500 pM and high selectively towards amyl butyrate, with a sensitivity as low as 500 fM, whilst control measurements using non-specific esters, produced a negligible sensor response. The approach described here provides an alternative sensing platform that can be used in bioelectronic nose applications.
- 8 July 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (7) , 174
Open AccessGraphene Bioelectronic Nose for the Detection of Odorants with Human Olfactory Receptor 2AG1
A real-time sensor for the detection of amyl butyrate (AB) utilising human olfactory receptor 2AG1 (OR2AG1), a G-protein coupled receptor (GPCR) consisting of seven transmembrane domains, immobilized onto a graphene resistor is demonstrated. Using CVD graphene as the sensor platform, allows greater potential for more sensitive detection than similar sensors based on carbon nanotubes, gold or graphene oxide platforms. A specific graphene resistor sensor was fabricated and modified via non-covalent π–π stacking of 1,5 diaminonaphthalene (DAN) onto the graphene channel, and subsequent anchoring of the OR2AG1 receptor to the DAN molecule using glutaraldehyde coupling. Binding between the target odorant, amyl butyrate, and the OR2AG1 receptor protein generated a change in resistance of the graphene resistor sensor. The functionalized graphene resistor sensors exhibited a linear sensor response between 0.1–500 pM and high selectively towards amyl butyrate, with a sensitivity as low as 500 fM, whilst control measurements using non-specific esters, produced a negligible sensor response. The approach described here provides an alternative sensing platform that can be used in bioelectronic nose applications.
- Open Access
- 10 September 2020
- Published by MDPI AG in Nanomaterials
- Vol. 10 (9) , 1808
A Facile Method for the Non-Covalent Amine Functionalization of Carbon-Based Surfaces for Use in Biosensor Development
Affinity biosensors based on graphene field-effect transistor (GFET) or resistor designs require the utilization of graphene’s exceptional electrical properties. Therefore, it is critical when designing these sensors, that the electrical properties of graphene are maintained throughout the functionalization process. To that end, non-covalent functionalization may be preferred over covalent modification. Drop-cast 1,5-diaminonaphthalene (DAN) was investigated as a quick and simple method for the non-covalent amine functionalization of carbon-based surfaces such as graphene, for use in biosensor development. In this work, multiple graphene surfaces were functionalized with DAN via a drop-cast method, leading to amine moieties, available for subsequent attachment to receptor molecules. Successful modification of graphene with DAN via a drop-cast method was confirmed using X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and real-time resistance measurements. Successful attachment of receptor molecules also confirmed using the aforementioned techniques. Furthermore, an investigation into the effect of sequential wash steps which are required in biosensor manufacture, on the presence of the DAN layer, confirmed that the functional layer was not removed, even after multiple solvent exposures. Drop-cast DAN is thus, a viable fast and robust method for the amine functionalization of graphene surfaces for use in biosensor development.
- 10 September 2020
- Published by MDPI AG in Nanomaterials
- Vol. 10 (9) , 1808
Open AccessA Facile Method for the Non-Covalent Amine Functionalization of Carbon-Based Surfaces for Use in Biosensor Development
Affinity biosensors based on graphene field-effect transistor (GFET) or resistor designs require the utilization of graphene’s exceptional electrical properties. Therefore, it is critical when designing these sensors, that the electrical properties of graphene are maintained throughout the functionalization process. To that end, non-covalent functionalization may be preferred over covalent modification. Drop-cast 1,5-diaminonaphthalene (DAN) was investigated as a quick and simple method for the non-covalent amine functionalization of carbon-based surfaces such as graphene, for use in biosensor development. In this work, multiple graphene surfaces were functionalized with DAN via a drop-cast method, leading to amine moieties, available for subsequent attachment to receptor molecules. Successful modification of graphene with DAN via a drop-cast method was confirmed using X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and real-time resistance measurements. Successful attachment of receptor molecules also confirmed using the aforementioned techniques. Furthermore, an investigation into the effect of sequential wash steps which are required in biosensor manufacture, on the presence of the DAN layer, confirmed that the functional layer was not removed, even after multiple solvent exposures. Drop-cast DAN is thus, a viable fast and robust method for the amine functionalization of graphene surfaces for use in biosensor development.