Jianming Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jianming Li has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Jiao Wang
TEDA International Cardiovascular Hospital, Clinical College of Cardiovascular Diseases, Tianjin Medical University
16 shared publicationsYue Chen
TEDA International Cardiovascular Hospital, Clinical College of Cardiovascular Diseases, Tianjin Medical University
16 shared publicationsZekun Pang
TEDA International Cardiovascular Hospital, Clinical College of Cardiovascular Diseases, Tianjin Medical University
13 shared publicationsFukai Zhao
TEDA International Cardiovascular Hospital, Clinical College of Cardiovascular Diseases, Tianjin Medical University
8 shared publications- Zekun Pang
Department of Nuclear Medicine, TEDA International Cardiovascular Hospital, Tianjin, China
8 shared publications - Bailing Hsu
Nuclear Science and Engineering Institute, University of Missouri-Columbia, Columbia, USA
6 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (9) , e0358657
Quantitative [13N]ammonia/[18F]FDG PET/CT predicts left ventricular functional recovery after CABG in ischemic cardiomyopathy: An exploratory study
Background: In patients with ischemic cardiomyopathy (ICM), accurate preoperative identification of viable myocardium is clinically important to identify those who are likely to benefit from coronary artery bypass grafting (CABG). Although the PET perfusion–metabolism mismatch index has long been used to assess myocardial viability, its value in predicting contractile recovery remains controversial. Quantitative metabolic indices based on standardized uptake value (SUV) may provide complementary prognostic information. Methods: This single-center retrospective cohort study included 53 patients with ICM who underwent preoperative [ 13 N]ammonia/[ 18 F]FDG PET/CT followed by isolated CABG. Conventional perfusion–metabolism indices were compared with SUV-based indices. The evaluated outcomes were postoperative increases in left ventricular ejection fraction (ΔLVEF) of ≥5% and ≥10% on follow-up echocardiography, and time to first major adverse cardiovascular event (MACE). Each PET parameter was evaluated in a separate multivariable Firth-penalized logistic regression model adjusted a priori for age, baseline LVEF, history of coronary artery disease, and diabetes. The predictive performance was assessed by receiver operating characteristic analysis, and time to MACE by Cox regression with the adjustment of multiple testing and model optimism. Results: Of the 53 patients, 32 (60.4%) achieved ΔLVEF ≥5% and 25 (47.2%) achieved ΔLVEF ≥10%. The infarct-to-non-infarct SUV ratio (SUVR) was associated with ΔLVEF ≥5% (odds ratio [OR] 1.94 per 0.1-unit increase, 95% confidence interval [CI] 1.28–3.25; P < 0.001; q = 0.003) and ΔLVEF ≥10% (OR 1.53, 95% CI 1.11–2.29; P = 0.004; q = 0.035). For the prediction of ΔLVEF ≥5%, SUVR had a higher area under the curve (AUC) than the mismatch index (0.83 vs 0.62; DeLong P = 0.0049; q = 0.0147). For the prediction of ΔLVEF ≥10%, the AUCs did not differ (0.73 and 0.63; DeLong P = 0.200; q = 0.383). No individual PET parameter was associated with time to first MACE in adjusted Cox models. Conclusions: SUVR showed greater discrimination for postoperative ΔLVEF ≥5% than the conventional perfusion–metabolism mismatch index. This finding supports SUVR as a quantitative adjunct to conventional PET viability assessment and warrants further multicenter validation.
- 21 September 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (9) , e0358657
Open AccessQuantitative [13N]ammonia/[18F]FDG PET/CT predicts left ventricular functional recovery after CABG in ischemic cardiomyopathy: An exploratory study
Background: In patients with ischemic cardiomyopathy (ICM), accurate preoperative identification of viable myocardium is clinically important to identify those who are likely to benefit from coronary artery bypass grafting (CABG). Although the PET perfusion–metabolism mismatch index has long been used to assess myocardial viability, its value in predicting contractile recovery remains controversial. Quantitative metabolic indices based on standardized uptake value (SUV) may provide complementary prognostic information. Methods: This single-center retrospective cohort study included 53 patients with ICM who underwent preoperative [ 13 N]ammonia/[ 18 F]FDG PET/CT followed by isolated CABG. Conventional perfusion–metabolism indices were compared with SUV-based indices. The evaluated outcomes were postoperative increases in left ventricular ejection fraction (ΔLVEF) of ≥5% and ≥10% on follow-up echocardiography, and time to first major adverse cardiovascular event (MACE). Each PET parameter was evaluated in a separate multivariable Firth-penalized logistic regression model adjusted a priori for age, baseline LVEF, history of coronary artery disease, and diabetes. The predictive performance was assessed by receiver operating characteristic analysis, and time to MACE by Cox regression with the adjustment of multiple testing and model optimism. Results: Of the 53 patients, 32 (60.4%) achieved ΔLVEF ≥5% and 25 (47.2%) achieved ΔLVEF ≥10%. The infarct-to-non-infarct SUV ratio (SUVR) was associated with ΔLVEF ≥5% (odds ratio [OR] 1.94 per 0.1-unit increase, 95% confidence interval [CI] 1.28–3.25; P < 0.001; q = 0.003) and ΔLVEF ≥10% (OR 1.53, 95% CI 1.11–2.29; P = 0.004; q = 0.035). For the prediction of ΔLVEF ≥5%, SUVR had a higher area under the curve (AUC) than the mismatch index (0.83 vs 0.62; DeLong P = 0.0049; q = 0.0147). For the prediction of ΔLVEF ≥10%, the AUCs did not differ (0.73 and 0.63; DeLong P = 0.200; q = 0.383). No individual PET parameter was associated with time to first MACE in adjusted Cox models. Conclusions: SUVR showed greater discrimination for postoperative ΔLVEF ≥5% than the conventional perfusion–metabolism mismatch index. This finding supports SUVR as a quantitative adjunct to conventional PET viability assessment and warrants further multicenter validation.
- Open Access
- 1 September 2026
- Published by Springer Nature in Scientific Reports
[18F]TD-1, a novel GP IIb/IIIa targeted PET tracer for thrombus imaging: design, synthesis, and preclinical imaging evaluation
- 1 September 2026
- Published by Springer Nature in Scientific Reports
Open Access[18F]TD-1, a novel GP IIb/IIIa targeted PET tracer for thrombus imaging: design, synthesis, and preclinical imaging evaluation
- Open Access
- 1 September 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (9) , 715
Quantitative and semi-quantitative comparison of myocardial blood flow between 99mTc-tetrofosmin and 99mTc-sestamibi: based on continuous rapid dynamic imaging technology using cadmium-zinc-telluride cardiac single-photon emission computed tomography
Background: Dynamic imaging with cardiac-dedicated cadmium-zinc-telluride single-photon emission computed tomography (CZT-SPECT) enables both the absolute quantification of myocardial blood flow (MBF) and the semi-quantitative assessment of myocardial perfusion imaging (MPI). This study aimed to investigate and compare differences in quantitative and semi-quantitative outcomes between technetium-99m-tetrofosmin (99mTc-TF; TF group) and technetium-99m-sestamibi (99mTc-MIBI; MIBI group) using a continuous rapid dynamic acquisition protocol. Methods: Patients with no or mild coronary artery disease (CAD) who underwent myocardial flow reserve (MFR) assessment using a CZT-SPECT continuous rapid dynamic acquisition protocol were retrospectively enrolled in the study (n=100 per group). Quantitative perfusion parameters [rest MBF (rMBF), stress MBF (sMBF), and MFR] were compared between groups for each coronary territory and the whole left ventricle (LV). Within-group coefficients of variation (CVs) and multivariate linear regression analyses were performed. Semi-quantitative perfusion indices and left ventricular functional parameters were also compared. MPI image quality was scored for both groups. Comparisons of scores and assessments of interobserver reproducibility were performed. Results: No significant differences were observed in the baseline demographic and clinical characteristics between the TF and MIBI groups (all P>0.05). Quantitative flow analysis revealed no significant between-group differences in rMBF for the left circumflex (LCX) artery, right coronary artery (RCA), or the global LV (all P>0.05). In contrast, significant between-group differences were observed in rMBF in the left anterior descending (LAD) artery, as well as in sMBF and MFR across all coronary territories and global LV values (all values were higher in the MIBI group than in the TF group; all P0.05). Image quality scores differed significantly in both between-group comparisons and within-group comparisons between stress and rest imaging (all PConclusions: Under a continuous rapid dynamic acquisition protocol, 99mTc-TF provides conventional semi-quantitative perfusion parameters and left ventricular functional indices comparable to those obtained with 99mTc-MIBI, while offering superior MPI image quality. Differences in quantitative flow measurements were observed between the two tracers. These findings suggest that further head-to-head studies using positron emission tomography (PET) as the reference standard are warranted to establish TF-specific quantitative parameters.
- 1 September 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (9) , 715
Open AccessQuantitative and semi-quantitative comparison of myocardial blood flow between 99mTc-tetrofosmin and 99mTc-sestamibi: based on continuous rapid dynamic imaging technology using cadmium-zinc-telluride cardiac single-photon emission computed tomography
Background: Dynamic imaging with cardiac-dedicated cadmium-zinc-telluride single-photon emission computed tomography (CZT-SPECT) enables both the absolute quantification of myocardial blood flow (MBF) and the semi-quantitative assessment of myocardial perfusion imaging (MPI). This study aimed to investigate and compare differences in quantitative and semi-quantitative outcomes between technetium-99m-tetrofosmin (99mTc-TF; TF group) and technetium-99m-sestamibi (99mTc-MIBI; MIBI group) using a continuous rapid dynamic acquisition protocol. Methods: Patients with no or mild coronary artery disease (CAD) who underwent myocardial flow reserve (MFR) assessment using a CZT-SPECT continuous rapid dynamic acquisition protocol were retrospectively enrolled in the study (n=100 per group). Quantitative perfusion parameters [rest MBF (rMBF), stress MBF (sMBF), and MFR] were compared between groups for each coronary territory and the whole left ventricle (LV). Within-group coefficients of variation (CVs) and multivariate linear regression analyses were performed. Semi-quantitative perfusion indices and left ventricular functional parameters were also compared. MPI image quality was scored for both groups. Comparisons of scores and assessments of interobserver reproducibility were performed. Results: No significant differences were observed in the baseline demographic and clinical characteristics between the TF and MIBI groups (all P>0.05). Quantitative flow analysis revealed no significant between-group differences in rMBF for the left circumflex (LCX) artery, right coronary artery (RCA), or the global LV (all P>0.05). In contrast, significant between-group differences were observed in rMBF in the left anterior descending (LAD) artery, as well as in sMBF and MFR across all coronary territories and global LV values (all values were higher in the MIBI group than in the TF group; all P0.05). Image quality scores differed significantly in both between-group comparisons and within-group comparisons between stress and rest imaging (all PConclusions: Under a continuous rapid dynamic acquisition protocol, 99mTc-TF provides conventional semi-quantitative perfusion parameters and left ventricular functional indices comparable to those obtained with 99mTc-MIBI, while offering superior MPI image quality. Differences in quantitative flow measurements were observed between the two tracers. These findings suggest that further head-to-head studies using positron emission tomography (PET) as the reference standard are warranted to establish TF-specific quantitative parameters.
- Open Access
- 28 August 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (9) , 421
Value of Multi-Parameter Combined Application of CZT-SPECT and CCTA in Risk Stratification of Short-Term Myocardial Ischemic Events in Patients with Chronic Coronary Syndromes
Background: This study aimed to investigate the predictive value of the multi-parameter combined application of cadmium–zinc–telluride single-photon emission computed tomography (CZT-SPECT) and coronary computed tomography angiography (CCTA) for short-term myocardial ischemic events in patients with chronic coronary syndromes (CCS). Methods: A total of 205 CCS patients who underwent both CZT-SPECT and concurrent CCTA were retrospectively enrolled. A reversible ischemia indicator (summed difference score, SDS) from CZT-SPECT and an inflammatory marker (fat attenuation index, FAI) from CCTA were obtained. Short-term myocardial ischemic major adverse cardiovascular events (MACEs) were recorded. Cox regression assessed independent predictive value, while net reclassification improvement (NRI), integrated discrimination improvement (IDI), and Kaplan–Meier curves evaluated incremental predictive and risk stratification ability. Results: 19 myocardial ischemic MACEs occurred. SDS was an independent predictor (HR: 1.386; 95%CI: 1.032–1.861; p = 0.030). Adding FAI to the combination of clinical factors and SDS significantly improved prediction (NRI = 0.215, p = 0.037; IDI = 0.043, p = 0.017). The high-SDS plus high-FAI group had the highest event rates (20.0%, all p < 0.05). Conclusions: SDS appears to be an independent predictor of short-term ischemic MACE. FAI may further stratify risk among patients with high SDS, with those exhibiting both high SDS and high FAI having the highest event rates. These findings should be considered hypothesis-generating and warrant confirmation in larger prospective cohorts.
- 28 August 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (9) , 421
Open AccessValue of Multi-Parameter Combined Application of CZT-SPECT and CCTA in Risk Stratification of Short-Term Myocardial Ischemic Events in Patients with Chronic Coronary Syndromes
Background: This study aimed to investigate the predictive value of the multi-parameter combined application of cadmium–zinc–telluride single-photon emission computed tomography (CZT-SPECT) and coronary computed tomography angiography (CCTA) for short-term myocardial ischemic events in patients with chronic coronary syndromes (CCS). Methods: A total of 205 CCS patients who underwent both CZT-SPECT and concurrent CCTA were retrospectively enrolled. A reversible ischemia indicator (summed difference score, SDS) from CZT-SPECT and an inflammatory marker (fat attenuation index, FAI) from CCTA were obtained. Short-term myocardial ischemic major adverse cardiovascular events (MACEs) were recorded. Cox regression assessed independent predictive value, while net reclassification improvement (NRI), integrated discrimination improvement (IDI), and Kaplan–Meier curves evaluated incremental predictive and risk stratification ability. Results: 19 myocardial ischemic MACEs occurred. SDS was an independent predictor (HR: 1.386; 95%CI: 1.032–1.861; p = 0.030). Adding FAI to the combination of clinical factors and SDS significantly improved prediction (NRI = 0.215, p = 0.037; IDI = 0.043, p = 0.017). The high-SDS plus high-FAI group had the highest event rates (20.0%, all p < 0.05). Conclusions: SDS appears to be an independent predictor of short-term ischemic MACE. FAI may further stratify risk among patients with high SDS, with those exhibiting both high SDS and high FAI having the highest event rates. These findings should be considered hypothesis-generating and warrant confirmation in larger prospective cohorts.
- Open Access
- 17 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2610
The Effect of Motion Correction on Quantitative Perfusion Indices and Threshold-Based Interpretation in 13N-Ammonia Dynamic PET Myocardial Perfusion Imaging
Background/Objectives: The effect of cardiac motion on dynamic positron emission tomography (PET) myocardial perfusion imaging (MPI) could distort the quantitative perfusion indices during acquisition, depending on direction, magnitude, and vascular territory. This study aimed to assess the impact of motion correction (MC) and its influences on quantitative perfusion indices using a comprehensive range of established statistical methods. Method: We retrospectively analyzed 171 patients’ data who underwent 13N-ammonia dynamic PET/CT-MPI. All the rebinned listmode data were transferred to the dedicated workstation for MC and quantification, yielding paired MC and non-motion correction (NMC) datasets for both phases. Frame-by-frame post-MC vectors were used to characterize motion magnitude and direction. Paired comparisons, directional analysis, association, agreement, accuracy, precision, and clinical reclassification were performed. Results: Motion occurred during both acquisition phases, but it was more frequent, more heterogeneous, and generally greater during stress, with the most notable displacement along the Y-axis. MC had a limited impact on the rest myocardial blood flow (MBF) but showed more significant effects on stress MBF, myocardial flow reserve (MFR), and non-invasive fractional flow reserve (niFFR) -like index, especially in the left anterior descending artery (LAD). Although MC and NMC values remained strongly associated for MBF and MFR, they were not fully interchangeable. The bidirectional reclassification of MFR and niFFR-like index showed that MC responded to the direction and magnitude of motion rather than a simple increase the values. Conclusions: MC exerts a structured, bidirectional, and motion-dependent influence on quantitative dynamic PET-MPI and has an impact beyond simple numerical adjustment.
- 17 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2610
Open AccessThe Effect of Motion Correction on Quantitative Perfusion Indices and Threshold-Based Interpretation in 13N-Ammonia Dynamic PET Myocardial Perfusion Imaging
Background/Objectives: The effect of cardiac motion on dynamic positron emission tomography (PET) myocardial perfusion imaging (MPI) could distort the quantitative perfusion indices during acquisition, depending on direction, magnitude, and vascular territory. This study aimed to assess the impact of motion correction (MC) and its influences on quantitative perfusion indices using a comprehensive range of established statistical methods. Method: We retrospectively analyzed 171 patients’ data who underwent 13N-ammonia dynamic PET/CT-MPI. All the rebinned listmode data were transferred to the dedicated workstation for MC and quantification, yielding paired MC and non-motion correction (NMC) datasets for both phases. Frame-by-frame post-MC vectors were used to characterize motion magnitude and direction. Paired comparisons, directional analysis, association, agreement, accuracy, precision, and clinical reclassification were performed. Results: Motion occurred during both acquisition phases, but it was more frequent, more heterogeneous, and generally greater during stress, with the most notable displacement along the Y-axis. MC had a limited impact on the rest myocardial blood flow (MBF) but showed more significant effects on stress MBF, myocardial flow reserve (MFR), and non-invasive fractional flow reserve (niFFR) -like index, especially in the left anterior descending artery (LAD). Although MC and NMC values remained strongly associated for MBF and MFR, they were not fully interchangeable. The bidirectional reclassification of MFR and niFFR-like index showed that MC responded to the direction and magnitude of motion rather than a simple increase the values. Conclusions: MC exerts a structured, bidirectional, and motion-dependent influence on quantitative dynamic PET-MPI and has an impact beyond simple numerical adjustment.
- Open Access
- 27 July 2026
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- p. 1-12
Added Value of CZT SPECT Myocardial Blood Flow Quantification for Detecting Obstructive Coronary Artery Disease in Patients with Normal Perfusion Imaging
Purpose: The goal of this study was to investigate the added value of absolute MBF quantitation measured with cardiac-dedicated CZT SPECT to enhance the detection of hidden myocardial hypoperfusion for patients with obstructive coronary artery disease and normal perfusion. Methods: A total of 501 patients with normal myocardial perfusion imaging (MPI) results who underwent dynamic cardiac-dedicated CZT SPECT for MBF quantitation, routine MPI, and invasive coronary angiography (CAG) were retrospectively identified from the clinical database. Stenosis of > 50% in the left main artery or > 70% in major coronary arteries was defined as obstructive coronary artery disease (OCAD). Results: Among patients with normal MPI results, 44.7% had angiographically confirmed OCAD. Male patients exhibited a higher proportion of false-negative MPI results than female patients (54.2% vs. 39.9%, p < 0.05). Quantitative parameters, including stress myocardial blood flow (MBF) and myocardial flow reserve (MFR), were significantly reduced in the OCAD group, while myocardial flow capacity (MFC) was notably impaired. When flow parameters with cutoffs derived from comparison with CAG were added, the detection rate of myocardial hypoperfusion increased to 45.2% in male patients and 27.9% in female patients. The diagnostic sensitivity of SPECT MBF quantitation for detecting hypoperfusion of OCAD in patients with normal MPI was 45.1%-50.9%, and the diagnostic specificity was 81.6%-99.6%. Conclusions: Absolute quantitative MBF measurements with cardiac-dedicated CZT SPECT add clinical benefits in uncovering hidden myocardial hypoperfusion for patients who had OCAD and normal MPI.
- 27 July 2026
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- p. 1-12
Open AccessAdded Value of CZT SPECT Myocardial Blood Flow Quantification for Detecting Obstructive Coronary Artery Disease in Patients with Normal Perfusion Imaging
Purpose: The goal of this study was to investigate the added value of absolute MBF quantitation measured with cardiac-dedicated CZT SPECT to enhance the detection of hidden myocardial hypoperfusion for patients with obstructive coronary artery disease and normal perfusion. Methods: A total of 501 patients with normal myocardial perfusion imaging (MPI) results who underwent dynamic cardiac-dedicated CZT SPECT for MBF quantitation, routine MPI, and invasive coronary angiography (CAG) were retrospectively identified from the clinical database. Stenosis of > 50% in the left main artery or > 70% in major coronary arteries was defined as obstructive coronary artery disease (OCAD). Results: Among patients with normal MPI results, 44.7% had angiographically confirmed OCAD. Male patients exhibited a higher proportion of false-negative MPI results than female patients (54.2% vs. 39.9%, p < 0.05). Quantitative parameters, including stress myocardial blood flow (MBF) and myocardial flow reserve (MFR), were significantly reduced in the OCAD group, while myocardial flow capacity (MFC) was notably impaired. When flow parameters with cutoffs derived from comparison with CAG were added, the detection rate of myocardial hypoperfusion increased to 45.2% in male patients and 27.9% in female patients. The diagnostic sensitivity of SPECT MBF quantitation for detecting hypoperfusion of OCAD in patients with normal MPI was 45.1%-50.9%, and the diagnostic specificity was 81.6%-99.6%. Conclusions: Absolute quantitative MBF measurements with cardiac-dedicated CZT SPECT add clinical benefits in uncovering hidden myocardial hypoperfusion for patients who had OCAD and normal MPI.
- 25 July 2026
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 61, 102803
The enforced evidence of single-photon emission computed tomography myocardial blood flow quantitation toward clinical utilization
- 25 July 2026
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 61, 102803
The enforced evidence of single-photon emission computed tomography myocardial blood flow quantitation toward clinical utilization
- Open Access
- 16 July 2026
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 26 (1)
Incremental prognostic value of AI-based coronary CT angiography combined with PET/CT dynamic myocardial perfusion imaging in patients with suspected or confirmed coronary artery disease
Background: Coronary computed tomography angiography (CCTA) and positron emission tomography/computed tomography (PET/CT) myocardial perfusion imaging (MPI) provide complementary anatomical and functional information for coronary artery disease (CAD). However, the prognostic value of integrating CCTA-derived coronary imaging characteristics with PET-MPI parameters remains to be established. Therefore, this retrospective single-center study aimed to evaluate the prognostic and incremental value of integrating artificial intelligence (AI)–based CCTA with PET/CT MPI for predicting major adverse cardiovascular events (MACEs) in patients with CAD. Methods: Patients with suspected or confirmed CAD underwent PET/CT dynamic MPI and contemporaneous CCTA were retrospectively enrolled and followed for at least 12 months for MACEs. MACEs were defined as the occurrence of at least one of the following endpoints: all-cause death, nonfatal myocardial infarction, new-onset heart failure, rehospitalization for angina, or late coronary revascularization. Clinical characteristics, AI-derived CCTA features, and PET-MPI parameters were collected. To reduce the number of candidate variables and mitigate potential multicollinearity, LASSO regression was applied as an exploratory variable selection method. Variables with non-zero coefficients were subsequently included in multivariable Cox proportional hazards models to assess their associations with the risk of MACEs. Dose-response relationships were further explored using restricted cubic spline analyses. Incremental prognostic value was evaluated using hierarchical Cox regression models. Results: A total of 71 patients (mean age 60.17 ± 12.36 years; 59.2% male) were included, with 18 MACEs occurring over a median follow-up of 25.69 months. Patients with MACEs more frequently exhibited obstructive coronary stenosis, abnormal PET-MPI semiquantitative parameters, reduced CT-derived fractional flow reserve (CT-FFR), and a higher burden of high-risk plaque features (all P < 0.05). The total number of high-risk plaque features was significantly associated with the risk of MACEs (HR 1.898, 95% CI 1.015–3.546; P = 0.045) and showed a trend toward a linear relationship with event risk. PET-MPI semiquantitative parameters improved prognostic performance beyond the clinical baseline model ( P = 0.011), and further incorporation of high-risk plaque feature count significantly improved model performance across functional models (all P < 0.05). Conclusions: AI-driven CCTA integrated with PET/CT dynamic MPI may provide prognostic information in patients with CAD. PET-MPI semiquantitative parameters and the total number of high-risk plaque features were associated with risk and may offer complementary and incremental value for predicting MACEs. These findings warrant further validation in larger cohorts.
- 16 July 2026
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 26 (1)
Open AccessIncremental prognostic value of AI-based coronary CT angiography combined with PET/CT dynamic myocardial perfusion imaging in patients with suspected or confirmed coronary artery disease
Background: Coronary computed tomography angiography (CCTA) and positron emission tomography/computed tomography (PET/CT) myocardial perfusion imaging (MPI) provide complementary anatomical and functional information for coronary artery disease (CAD). However, the prognostic value of integrating CCTA-derived coronary imaging characteristics with PET-MPI parameters remains to be established. Therefore, this retrospective single-center study aimed to evaluate the prognostic and incremental value of integrating artificial intelligence (AI)–based CCTA with PET/CT MPI for predicting major adverse cardiovascular events (MACEs) in patients with CAD. Methods: Patients with suspected or confirmed CAD underwent PET/CT dynamic MPI and contemporaneous CCTA were retrospectively enrolled and followed for at least 12 months for MACEs. MACEs were defined as the occurrence of at least one of the following endpoints: all-cause death, nonfatal myocardial infarction, new-onset heart failure, rehospitalization for angina, or late coronary revascularization. Clinical characteristics, AI-derived CCTA features, and PET-MPI parameters were collected. To reduce the number of candidate variables and mitigate potential multicollinearity, LASSO regression was applied as an exploratory variable selection method. Variables with non-zero coefficients were subsequently included in multivariable Cox proportional hazards models to assess their associations with the risk of MACEs. Dose-response relationships were further explored using restricted cubic spline analyses. Incremental prognostic value was evaluated using hierarchical Cox regression models. Results: A total of 71 patients (mean age 60.17 ± 12.36 years; 59.2% male) were included, with 18 MACEs occurring over a median follow-up of 25.69 months. Patients with MACEs more frequently exhibited obstructive coronary stenosis, abnormal PET-MPI semiquantitative parameters, reduced CT-derived fractional flow reserve (CT-FFR), and a higher burden of high-risk plaque features (all P < 0.05). The total number of high-risk plaque features was significantly associated with the risk of MACEs (HR 1.898, 95% CI 1.015–3.546; P = 0.045) and showed a trend toward a linear relationship with event risk. PET-MPI semiquantitative parameters improved prognostic performance beyond the clinical baseline model ( P = 0.011), and further incorporation of high-risk plaque feature count significantly improved model performance across functional models (all P < 0.05). Conclusions: AI-driven CCTA integrated with PET/CT dynamic MPI may provide prognostic information in patients with CAD. PET-MPI semiquantitative parameters and the total number of high-risk plaque features were associated with risk and may offer complementary and incremental value for predicting MACEs. These findings warrant further validation in larger cohorts.
- Open Access
- 15 May 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (20) , e48852
Assessment of the impact of post-processing approaches on absolute myocardial blood flow quantification using cardiac-dedicated CZT-SPECT: A retrospective observational study
Quantitative myocardial blood flow (MBF) assessment using cardiac-dedicated cadmium-zinc-telluride (CZT) single photon emission computed tomography (SPECT) has emerged as a promising noninvasive approach for evaluating both macrovascular and microvascular coronary function. However, the reliability and comparability of MBF measurements are substantially influenced by variations in post-processing methodologies, including the application of attenuation correction (AC) and scatter correction (SC) techniques. Despite the increasing clinical adoption of CZT-SPECT for absolute perfusion quantification, systematic evaluations comparing different post-processing strategies remain limited. This study aimed to evaluate the impact of various post-processing approaches on absolute quantitative MBF measurements obtained through CZT-SPECT, with particular focus on AC and SC methodologies. Seventy patients who underwent dynamic CZT-SPECT myocardial perfusion imaging were retrospectively included, comprising 35 Tc-99m-methoxyisobutylisonitrile patients and 35 Tc-99m-tetrofosmin patients. Each raw imaging dataset was independently reprocessed using Corridor 4DM under 3 correction strategies – no correction, attenuation correction, and attenuation + scatter correction (ACSC) – as well as using MyoFlowQ. Repeated-measures analysis of variance or Friedman tests with Holm-adjusted pairwise comparisons were used to compare the Corridor 4DM processing strategies, and agreement between Corridor 4DM with ACSC and MyoFlowQ was assessed using Bland–Altman analysis. Rest and stress MBF differed significantly across the Corridor 4DM processing strategies (both P < .001). Myocardial flow reserve (MFR) differences were tracer-dependent: no overall difference was observed in global left ventricular values in the Tc-99m-methoxyisobutylisonitrile cohort ( P = .121), whereas a significant difference was observed in the Tc-99m-tetrofosmin cohort ( P = .002). Compared with Corridor 4DM using ACSC, MyoFlowQ yielded higher stress MBF and MFR values (bias, 1.19–1.31 mL·g −1 ·min −1 ; 95% limits of agreement, –0.30 to 2.68), with moderate inter-software correlation ( r = 0.44–0.59, P < .01). Post-processing methodology significantly influenced absolute MBF quantification in CZT-SPECT imaging. Within Corridor 4DM, correction strategies affected MBF estimates, and MyoFlowQ yielded higher stress MBF and MFR values than Corridor 4DM using ACSC, indicating that these post-processing approaches are not directly interchangeable.
- 15 May 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (20) , e48852
Open AccessAssessment of the impact of post-processing approaches on absolute myocardial blood flow quantification using cardiac-dedicated CZT-SPECT: A retrospective observational study
Quantitative myocardial blood flow (MBF) assessment using cardiac-dedicated cadmium-zinc-telluride (CZT) single photon emission computed tomography (SPECT) has emerged as a promising noninvasive approach for evaluating both macrovascular and microvascular coronary function. However, the reliability and comparability of MBF measurements are substantially influenced by variations in post-processing methodologies, including the application of attenuation correction (AC) and scatter correction (SC) techniques. Despite the increasing clinical adoption of CZT-SPECT for absolute perfusion quantification, systematic evaluations comparing different post-processing strategies remain limited. This study aimed to evaluate the impact of various post-processing approaches on absolute quantitative MBF measurements obtained through CZT-SPECT, with particular focus on AC and SC methodologies. Seventy patients who underwent dynamic CZT-SPECT myocardial perfusion imaging were retrospectively included, comprising 35 Tc-99m-methoxyisobutylisonitrile patients and 35 Tc-99m-tetrofosmin patients. Each raw imaging dataset was independently reprocessed using Corridor 4DM under 3 correction strategies – no correction, attenuation correction, and attenuation + scatter correction (ACSC) – as well as using MyoFlowQ. Repeated-measures analysis of variance or Friedman tests with Holm-adjusted pairwise comparisons were used to compare the Corridor 4DM processing strategies, and agreement between Corridor 4DM with ACSC and MyoFlowQ was assessed using Bland–Altman analysis. Rest and stress MBF differed significantly across the Corridor 4DM processing strategies (both P < .001). Myocardial flow reserve (MFR) differences were tracer-dependent: no overall difference was observed in global left ventricular values in the Tc-99m-methoxyisobutylisonitrile cohort ( P = .121), whereas a significant difference was observed in the Tc-99m-tetrofosmin cohort ( P = .002). Compared with Corridor 4DM using ACSC, MyoFlowQ yielded higher stress MBF and MFR values (bias, 1.19–1.31 mL·g −1 ·min −1 ; 95% limits of agreement, –0.30 to 2.68), with moderate inter-software correlation ( r = 0.44–0.59, P < .01). Post-processing methodology significantly influenced absolute MBF quantification in CZT-SPECT imaging. Within Corridor 4DM, correction strategies affected MBF estimates, and MyoFlowQ yielded higher stress MBF and MFR values than Corridor 4DM using ACSC, indicating that these post-processing approaches are not directly interchangeable.
- Open Access
- 28 April 2026
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
The impact of motion correction on quantitatively measured perfusion indices using cardiac-dedicated dynamic CZT-SPECT myocardial perfusion imaging
Dynamic myocardial perfusion imaging (MPI) with cadmium-zinc-telluride (CZT) cardiac-dedicated single-photon emission computed tomography (SPECT) enables t
- 28 April 2026
- Published by Springer Nature in EJNMMI Physics
- Vol. 13 (1)
Open AccessThe impact of motion correction on quantitatively measured perfusion indices using cardiac-dedicated dynamic CZT-SPECT myocardial perfusion imaging
Dynamic myocardial perfusion imaging (MPI) with cadmium-zinc-telluride (CZT) cardiac-dedicated single-photon emission computed tomography (SPECT) enables t