Usha Kiran Rout
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Usha Kiran Rout has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Debdutta Bhattacharya
ICMR - National Institute of Health Research, Bhubaneswar, Odisha, India
3 shared publications - Jaya Singh Kshatri
ICMR-Regional Medical Research Centre, Bhubaneswar, India
3 shared publications - Jyotirmayee Turuk
Department of Microbiology, ICMR-Regional Medical Research Centre, Chandrasekharpur, Bhubaneswar, 751023, Odisha, India
3 shared publications - Sanghamitra Pati
ICMR-National Institute of Health Research, Bhubaneswar, Odisha, India
3 shared publications - Girish Chandra Dash
ICMR - Regional Medical Research Centre, Bhubaneswar
2 shared publications - Hari Ram Choudhary
ICMR - Regional Medical Research Centre, Bhubaneswar
2 shared publications
Latest Publications
- Open Access
Diagnostic comparison of three fully automated chemiluminescent immunoassay platforms for the detection of SARS-CoV-2 antibodies
The whole world is battling against coronavirus disease-19 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Various strategies are taken to curb the spread of the virus and to move out from the enforced lockdown stage. Serological tests are the neediest diagnostic and surveillance tool to complement the gold standard molecular diagnostic method to track down the transmission rate of SARS-CoV-2. Automated chemiluminescent immunoassay (CLIA) based analyzers become highly demanding platforms both to clinicians and policy makers for the detection anti-SARS-CoV-2 antibodies. In this study, serum from 594 patients positive for COVID-19 and 100 samples from pre-COVID cases were tested by three automated platforms: Abbott architect i2000SR, Roche cobas e411 and Yhlo iFlash 1800 and their diagnostic accuracy were compared. All three platforms showed high specificity as claimed by manufacturer. Clinical sensitivities of the machines were calculated as 64.48% (58.67-70.3) for Abbott, 80.48% (76.62-84.34) for Roche and 76.94% (72.65-81.23) for Yhlo. The Cohen’s kappa value was determined from 0.69-0.89 when inter-rater agreements were calculated. The area under the curves (AUC) values demonstrated Roche Cobas e411 as the diagnostically most accurate platform among the three CLIA analyzers.
Open AccessDiagnostic comparison of three fully automated chemiluminescent immunoassay platforms for the detection of SARS-CoV-2 antibodies
The whole world is battling against coronavirus disease-19 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Various strategies are taken to curb the spread of the virus and to move out from the enforced lockdown stage. Serological tests are the neediest diagnostic and surveillance tool to complement the gold standard molecular diagnostic method to track down the transmission rate of SARS-CoV-2. Automated chemiluminescent immunoassay (CLIA) based analyzers become highly demanding platforms both to clinicians and policy makers for the detection anti-SARS-CoV-2 antibodies. In this study, serum from 594 patients positive for COVID-19 and 100 samples from pre-COVID cases were tested by three automated platforms: Abbott architect i2000SR, Roche cobas e411 and Yhlo iFlash 1800 and their diagnostic accuracy were compared. All three platforms showed high specificity as claimed by manufacturer. Clinical sensitivities of the machines were calculated as 64.48% (58.67-70.3) for Abbott, 80.48% (76.62-84.34) for Roche and 76.94% (72.65-81.23) for Yhlo. The Cohen’s kappa value was determined from 0.69-0.89 when inter-rater agreements were calculated. The area under the curves (AUC) values demonstrated Roche Cobas e411 as the diagnostically most accurate platform among the three CLIA analyzers.
- Open Access
Saliva as a potential clinical specimen for diagnosis of SARS-CoV-2
Background: It is almost nine months, still there is no sign to stop the spreading of the COVID-19 pandemic. Rapid and early detection of the virus is the master key to cease the rapid spread and break the human transmission chain. There are very few studies in search of an alternate and convenient diagnostic tool which can substitute nasopharyngeal swab (NPS) specimen for detection of SARS-CoV-2. We aimed to analyse the comparison and agreement between the feasibility of using the saliva in comparison to NPS for diagnosis of SARS-CoV-2. Methods: A total number of 74 patients were enrolled for this study. We analysed and compared the NPS and saliva specimen collected within 48 h after the symptom onset. We used real time quantitative polymerase chain reaction (RT-qPCR), gene sequencing for the detection and determination SARS-CoV-2 specific genes. Phylogenetic tree was constructed to establish the isolation of viral RNA from saliva. We use Bland-Altman model to identify the agreement between two specimens. Findings: This study shows a lower C T mean value for the detection of SARS-CoV-2 ORF1 gene (27.07; 95% CI, 25.62 to 28.52) in saliva methods than that of NPS (28.24; 95% CI, 26.62 to 29.85) sampling method. Bland-Altman analysis produces relatively smaller bias and high agreement between these specimen tools. Phylogenetic analysis with the RdRp and Spike gene confirmed the presence of SARS-CoV-2 in the saliva samples. Interpretation: In conclusion, our study highlights that saliva represents a promising tool in COVID-19 diagnosis and would reduce the exposure risk of frontline health workers which is one of biggest concern in primary healthcare settings.
Open AccessSaliva as a potential clinical specimen for diagnosis of SARS-CoV-2
Background: It is almost nine months, still there is no sign to stop the spreading of the COVID-19 pandemic. Rapid and early detection of the virus is the master key to cease the rapid spread and break the human transmission chain. There are very few studies in search of an alternate and convenient diagnostic tool which can substitute nasopharyngeal swab (NPS) specimen for detection of SARS-CoV-2. We aimed to analyse the comparison and agreement between the feasibility of using the saliva in comparison to NPS for diagnosis of SARS-CoV-2. Methods: A total number of 74 patients were enrolled for this study. We analysed and compared the NPS and saliva specimen collected within 48 h after the symptom onset. We used real time quantitative polymerase chain reaction (RT-qPCR), gene sequencing for the detection and determination SARS-CoV-2 specific genes. Phylogenetic tree was constructed to establish the isolation of viral RNA from saliva. We use Bland-Altman model to identify the agreement between two specimens. Findings: This study shows a lower C T mean value for the detection of SARS-CoV-2 ORF1 gene (27.07; 95% CI, 25.62 to 28.52) in saliva methods than that of NPS (28.24; 95% CI, 26.62 to 29.85) sampling method. Bland-Altman analysis produces relatively smaller bias and high agreement between these specimen tools. Phylogenetic analysis with the RdRp and Spike gene confirmed the presence of SARS-CoV-2 in the saliva samples. Interpretation: In conclusion, our study highlights that saliva represents a promising tool in COVID-19 diagnosis and would reduce the exposure risk of frontline health workers which is one of biggest concern in primary healthcare settings.