DGDebora Gugelmin-Almeida

Debora Gugelmin-Almeida

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Debora Gugelmin-Almeida has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    SKIN TEARS: LESÕES POR FRICÇÃO EM PESSOA IDOSA E OS DIAGNÓSTICOS DE ENFERMAGEM

    by Lucia Tobase, Beatriz Brito dos Santos, Dhara Maria Orlando Costa da Cruz, Jaitiom Garcia De Paula, Debora Gugelmin Almeida

    O processo de envelhecimento populacional é tendência mundial, cujo crescimento exponencial é desafiador à sociedade. O declínio do funcionamento orgânico predispõe à redução da capacidade de resposta do corpo humano, aumenta o estado de vulnerabilidade e a fragilidade da pessoa idosa, especialmente em relação à pele. Esse trabalho objetivou organizar os diagnósticos de enfermagem para subsidiar o enfermeiro na proposição de intervenção e cuidados à pessoa idosa com lesões por fricção ou skin tears. Estudo exploratório, realizado em duas etapas, com revisão da literatura no período de dezembro/2022 a março/2023, e estruturação dos diagnósticos de enfermagem. Foram analisados 11 estudos publicados nos últimos dez anos, sobre skins tears em pessoas idosas e estruturados 14 diagnósticos de enfermagem. Foram abordadas as medidas preventivas, assistenciais e terapêuticas das skin tears, como aspectos para estruturar os diagnósticos de enfermagem à pessoa idosa. Diagnósticos assertivos são fundamentais para o correto planejamento e implementação da assistência qualificada e segura, influenciando na qualidade de vida da pessoa assistida.


  • Open Access

    The application of Borg scale in cardiopulmonary resuscitation: An integrative review

    by Lucia Tobase, Sandra Helena Cardoso, Renata Tavares Franco Rodrigues, Dhieizom Rodrigo de Souza, Debora Gugelmin-Almeida, Thatiane Facholi Polastri, Heloisa Helena Ciqueto Peres, Sergio Timerman

    The study of human performance and perception of exertion constitutes a fundamental aspect for monitoring health implications and enhancing training outcomes such as cardiopulmonary resuscitation (CPR). It involves gaining insights into the varied responses and tolerance levels exhibited by individuals engaging in physical activities. To measure perception of exertion, many tools are available, including the Borg scale. In order to evaluate how the Borg scale is being used during CPR attempts, this integrative review was carried out between October/2020 and December/2023, with searches from PubMed, CINAHL, Web of Science, Embase, PsycINFO and VHL. Full publications relevant to the PICO strategy were included and letters, editorials, abstracts, and unpublished studies were excluded. In total, 34 articles were selected and categorised into three themes: a) CPR performed in different contexts; b) CPR performed in different cycles, positions, and techniques; c) CPR performed with additional technological resources. Because CPR performance is considered a strenuous physical activity, the Borg scale was used in each study to evaluate perception of exertion. The results identified that the Borg scale has been used during CPR in different contexts. It is a quick, low-cost, and easy-to-apply tool that provides important indicators that may affect CPR quality, such as perception of exertion, likely improving performance and potentially increasing the chances of survival.


  • Open Access

    Addressing human factors in the recognition and management of local anaesthetic systemic toxicity

    by Niamh Eb Curtain, Debora Gugelmin-Almeida

    In the perioperative environment, local anaesthetics are commonly administered to patients to provide analgesia and anaesthesia for a large range of surgical procedures. Although rare, their use can result in systemic toxicity, which is a life-threatening complication, underscoring the importance of early recognition and prompt management to mitigate patient risks. This article evaluates the impact of human factors and other aspects such as insufficient monitoring, errors in drug administration and poor adherence to safety protocols on the development and management of local anaesthetic systemic toxicity and provides practical considerations to minimise its occurrence.

  • Open Access

    RE: Correspondence to: A novel retraining strategy of chest compression skills for infant CPR results in high skill retention for longer

    by Debora Gugelmin-Almeida, Michael Jones, Carol Clark, Ursula Rolfe, Jonathan Williams

  • Open Access

    What can be learned from the literature about intervals and strategies for paediatric CPR retraining of healthcare professionals? A scoping review of literature

    by Debora Gugelmin-Almeida, Lucia Tobase, Ian Maconochie, Thatiane Polastri, Elaine Cristina Rodrigues Gesteira, Jonathan Williams


  • Open Access

    A novel retraining strategy of chest compression skills for infant CPR results in high skill retention for longer

    by Debora Gugelmin-Almeida, Michael Jones, Carol Clark, Ursula Rolfe, Jonathan Williams

    Infant cardiopulmonary resuscitation (iCPR) is often poorly performed, predominantly because of ineffective learning, poor retention and decay of skills over time. The aim of this study was to investigate whether an individualized, competence-based approach to simulated iCPR retraining could result in high skill retention of infant chest compressions (iCC) at follow-up. An observational study with 118 healthcare students was conducted over 12 months from November 2019. Participants completed pediatric resuscitation training and a 2-min assessment on an infant mannequin. Participants returned for monthly assessment until iCC competence was achieved. Competence was determined by passing assessments in two consecutive months. After achieving competence, participants returned just at follow-up. For each ‘FAIL’ during assessment, up to six minutes of practice using real-time feedback was completed and the participant returned the following month. This continued until two consecutive monthly ‘PASSES’ were achieved, following which, the participant was deemed competent and returned just at follow-up. Primary outcome was retention of competence at follow-up. Descriptive statistics were used to analyze demographic data. Independent t-test or Mann–Whitney U test were used to analyze the baseline characteristics of those who dropped out compared to those remaining in the study. Differences between groups retaining competence at follow-up were determined using the Fisher exact test. On completion of training, 32 of 118 participants passed the assessment. Of those achieving iCC competence at month 1, 96% retained competence at 9–10 months; of those achieving competence at month 2, 86% demonstrated competence at 8–9 months; of those participants achieving competence at month 3, 67% retained competence at 7–8 months; for those achieving competence at month 4, 80% demonstrated retention at 6–7 months.   Conclusion: Becoming iCC competent after initial training results in high levels of skill retention at follow-up, regardless of how long it takes to achieve competence. What is Known:• Infant cardiopulmonary resuscitation (iCPR) is often poorly performed and skills decay within months after training.• Regular iCPR skills updates are important, but the optimal retraining interval considering individual training needs has yet to be established. What is New:• Infant chest compression (iCC) competence can be achieved within one to four months after training and once achieved, it can be retained for many months.• With skill reinforcement of up to 28 minutes after initial training, 90% of individuals were able to achieve competence in iCC and 86% retained this competence at follow-up.


  • Open Access

    Dominant versus non-dominant hand during simulated infant CPR using the two-finger technique: a randomised study

    by Debora Gugelmin-Almeida, Carol Clark, Ursula Rolfe, Michael Jones, Jonathan Williams


  • Open Access

    Do automated real-time feedback devices improve CPR quality? A systematic review of literature

    by Debora Gugelmin-Almeida, Lucia Tobase, Thatiane Facholi Polastri, Heloisa Helena Ciqueto Peres, Sergio Timerman


  • Open Access

    Consistency and variability in human performance during simulate infant CPR: a reliability study

    by Debora Almeida, Carol Clark, Michael Jones, Phillip McConnell, Jonathan Williams

    Background: Positive outcomes from infant cardiac arrest depend on the effective delivery of resuscitation techniques, including good quality infant cardiopulmonary resuscitation (iCPR) However, it has been established that iCPR skills decay within weeks or months after training. It is not known if the change in performance should be considered true change or inconsistent performance. The aim of this study was to investigate consistency and variability in human performance during iCPR. Methods: An experimental, prospective, observational study conducted within a university setting with 27 healthcare students (mean (SD) age 32.6 (11.6) years, 74.1% female). On completion of paediatric basic life support (BLS) training, participants performed three trials of 2-min iCPR on a modified infant manikin on two occasions (immediately after training and after 1 week), where performance data were captured. Main outcome measures were within-day and between-day repeated measures reliability estimates, determined using Intraclass Correlation Coefficients (ICCs), Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC95%) for chest compression rate, chest compression depth, residual leaning and duty cycle along with the conversion of these into quality indices according to international guidelines. Results: A high degree of reliability was found for within-day and between-day for each variable with good to excellent ICCs and narrow confidence intervals. SEM values were low, demonstrating excellent consistency in repeated performance. Within-day MDC values were low for chest compression depth and chest compression rate (6 and 9%) and higher for duty cycle (15%) and residual leaning (22%). Between-day MDC values were low for chest compression depth and chest compression rate (3 and 7%) and higher for duty cycle (21%) and residual leaning (22%). Reliability reduced when metrics were transformed in quality indices. Conclusion: iCPR skills are highly repeatable and consistent, demonstrating that changes in performance after training can be considered skill decay. However, when the metrics are transformed in quality indices, large changes are required to be confident of real change.