OSOnur Sözüdoğru

Onur Sözüdoğru

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Onur Sözüdoğru has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Flux‐Driven Ammonium Nitrogen Dynamics and Nutrient Removal Efficiency in Submerged MBR Systems Treating Diluted Neck Blood

    by Enes Özgenç, Onur Sözüdoğru, Okan Tarık Komesli

    This study investigated the treatment performance of high‐strength slaughterhouse neck blood wastewater using a submerged membrane bioreactor operated at different fluxes (8, 10, and 12 L m −2 h −1 ), corresponding to hydraulic retention times of 44.4, 35.5, and 29.6 h, respectively. The influent wastewater exhibited average chemical oxygen demand, ammonium nitrogen, and phosphate phosphorus concentrations of 1055 ± 70 mg L −1 , 0.3 ± 0.1 mg L −1 , and 45 ± 5 mg L −1 . The mixed liquor suspended solids concentration increased to approximately 12 g L −1 and remained stable under a sludge retention time of 50 days, indicating successful biomass acclimation. The system achieved high removal efficiencies for organic matter and phosphorus, with chemical oxygen demand and phosphate phosphorus removal exceeding 97% under all conditions and reaching 99.3 ± 0.4% and 99 ± 0.6%, respectively, at the lowest flux. In contrast, ammonium nitrogen accumulated in the effluent (40–70 mg L −1 ), indicating net ammonium production rather than removal. This behavior resulted from the biological degradation of protein‐rich substrates and limited nitrification under reduced hydraulic retention times. Increasing flux led to decreased effluent quality and increased membrane fouling. Short‐term transmembrane pressure analysis revealed that fouling rates increased from 2.55 to 7.33 kPa day −1 as flux increased from 8 to 12 L m −2 h −1 , resulting in a reduction of estimated cleaning intervals from approximately 10 days to 3–4 days. The findings demonstrate that submerged membrane bioreactor systems are highly effective for carbon removal and apparent orthophosphate reduction in protein‐rich wastewaters. In contrast, nitrogen removal remains a key limitation, underscoring the need to optimize operational conditions to improve treatment performance.

  • The experimental design approach to removal of endocrine disrupting compounds from domestic wastewater by electrooxidation process

    by Onur Sözüdoğru, Elif Seda Koçoğlu, Alper Erdem Ylmaz, Sezgin Bakirdere, Okan Tarık Komesli


  • Open Access

    The Experimental Design Approach to Removal of Endocrine Disrupting Compounds from Domestic Wastewater by Electrooxidation Process

    by Onur Sözüdoğru, Elif Seda Koçoğlu, Alper Erdem Yilmaz, Sezgin Bakirdere, Okan Tarık KOMESLİ

    In this study, the treatment performance of the process in the removal of Endocrine Disrupting Compounds (EDCs) from domestic wastewater by a laboratory-scale electrooxidation process using Ti/IrO₂/RuO₂ electrodes as an anode was evaluated using response surface method (RSM). The effect of pH, current density, and flow rate on the electrochemical treatment of 17α-ethinylestradiol, β-estradiol, triclosan, and estrone, which are often present in wastewater, has been studied. Using Box-Behnken Design (BBD), the parameters influencing the removal efficiencies were optimized for the Electrooxidation process (EOP), and the models created essential second-order quadratic models for the EOP process. The Response Surface Method yielded results that reasonably agreed with the measured values. The maximum removals of triclosan, 17α-ethinylestradiol, and β-estradiol were attained at 92,90%, 97,76%, and 95,36% respectively, under experimental conditions optimized pH= 3,68, current density= 20 A and flow rate= 8,83 mL/min for EOP. Removal efficiencies have achieved their maximum levels at low pH, high current density, and low flow rate. At the same time, the electrooxidation method could not completely remove the estrone.

  • Open Access

    Methylene Blue Removal by Electrooxidation Process Using Ti/IrO2/RuO2 Anode and Stainless Steel Cathode: The Role of Operating Parameters

    by Onur Sözüdoğru

    Bu çalışma, sentetik olarak hazırlanmış atık sudan Metilen Mavisi boyasının anot malzemesi olarak Ti/IrO2/RuO2 ve katot malzemesi olarak paslanmaz çelik kullanılarak laboratuvar ölçekli bir elektrooksidasyon prosesi (EOP) ile giderimini araştırmak için yapılmıştır. Atıksuyun başlangıç pH değeri (3.0, doğal pH (≈ 5.0), 7.0, 9.0 ve 11.0), akım yoğunluğu (1.0 mA cm-2, 1.5 mA cm-2, 2.0 mA cm-2 ve 2.5 mA cm-2), destek elektrolit türü (NaCI, KCI, Na2SO4 ve NaNO3) ve destek elektrolit konsantrasyonu (1.0 mM, 1.5 mM, 2.0 mM ve 2.5 mM) dahil olmak üzere proses değişkenlerinin Metilen Mavisi boya giderme verimliliği üzerindeki etkisi incelenmiştir. 30 dakikalık elektrokimyasal işlemde, Metilen Mavisi boyasının gideriminde en yüksek giderim (%78.31) doğal pH değerinde (≈5) elde edilmiştir. Destek elektrolit türü olarak %78.31’lik giderim verimi ile NaCI en iyi destek elektrolit olarak belirlendikten sonra, NaCI’nın konsantrasyonunun 1.0 mM’den 2.5 mM’ye çıkarılmasıyla giderim verimi %78.31’den %88.25’e kadar yükselmiştir. Giderimde etkisi incelenen son parametre olarak akım yoğunluğunun 1 mA cm-2’den 2.5 mA cm-2’ye artırılmasıyla Metilen Mavisi boya giderim verimi %78.31’den %88.98’e kadar artış görülmüştür. Deneysel sonuçlar Ti/IrO2/RuO2 anot kullanarak Metilen Mavisi boyasının etkin bir şekilde giderilmesinde elektrooksidasyon prosesinin uygunluğunu ortaya koymuştur. Özellikle dolaylı oksidasyonda Metilen Mavisi boyasının sadece redoks aracıları olarak görev yapan klorür iyonlarının varlığında elektroliz edildiği ve reaksiyonun klorür konsantrasyonundan ve uygulanan akım yoğunluğundan etkilendiği belirlenmiştir.


  • Investigation of the Treatment of Olive Mill Wastewater by Electrooxidation

    by Sinan Kul, Recep Boncukcuoğlu, Fatma Ekmekyapar Torun, Züleyha Reçber, Onur Sözüdoğru, Erdinç Aladağ


  • Performance Evaluation of A/O Membrane Bioreactor System in the Effective Removal of Endocrine-Disrupting Chemicals: the Effect of SRT and Flux Rate

    by Onur Sözüdoğru, Elif Seda Koçoğlu, Alper Erdem Yılmaz, Sezgin Bakırdere, Okan Tarık Komesli, Koçoğlu, Yılmaz


  • Influence of Hydraulic Retention Time (HRT) upon the Treatment of Wastewater by a Laboratory-Scale Membrane Bioreactor (MBR)

    by Onur Sözüdoğru, Theoni Maria Massara, Savaş Çalık, Alper Erdem Yılmaz, Sezgin Bakırdere, Evina Katsou, Okan Tarık Komesli

    The effect of applying different hydraulic retention times (HRTs) was investigated for a lab-scale membrane bioreactor (MBR) treating domestic wastewater. The submerged flat-type ultrafiltration MBR was operated under three HRTs (576 min, 462 min, and 372 min) corresponding to three operating periods to investigate its efficiency in removing organic content and nutrients from domestic wastewater. The chemical oxygen demand (COD) decreased from 99 to 96.5% with the HRT decreased from 576 min to 462 min. The bacteria performing nitrification were affected by the HRT change: the ammonium (NH4-N) removal dropped from 98.5% (HRT of 576 min) to 74.2% (HRT of 462 min). With the HRT adjusted to the lowest value of 372 min, the COD and NH4-N removals were 94.4% and 55.8%, respectively. The phosphate (PO4-P) removal was 59.1%, 34.4%, and 28% during periods 1, 2 and 3, respectively. In terms of the COD removal efficiency, the treated effluent met the Turkish limits for discharge to the receiving water during all of the operating periods. The system performance was suitable in terms of NH4-N removal for periods 1 (HRT of 576 min) and 2 (HRT of 462 min). However, applying the operating conditions of period 2 (i.e., maintaining the HRT at 462 min) requires additional post-treatment (e.g., low-cost chemical precipitation) to enhance the PO4-P removal.


  • Removal of Heavy Metals by a Membrane Bioreactor Combined with Activated Carbon

    by Savaş Çalik, Onur Sözüdoğru, Theoni Maria Massara, Alper Erdem Yılmaz, Sezgin Bakırdere, Evina Katsou, Okan Tarık Komesli

    The removal of nickel, lead, arsenic, and zinc was investigated by a lab-scale submerged membrane bioreactor (MBR) combined with granular activated carbon (GAC). Membrane fluxes of 16 L m−2 h−1, 20 L m−2 h−1, and 24 L m−2 h−1 with corresponding hydraulic retention times (HRTs) of 12.8 h, 10.4 h, and 9.2 h were applied as variables to examine their influence upon the removal efficiency. Synthetically prepared wastewater was pretreated in the MBR and GAC adsorption was employed as the post-treatment. Under the lowest applied flux value or, equivalently, the highest HRT applied, chemical oxygen demand (COD), ammonium (NH4-N) and phosphate (PO4-P) removals were found to be the highest (96.8%, 98.9% and 46%, respectively) for the MBR effluent. These results may be considered to be the result of alleviated membrane fouling and greater biomass growth. The highest heavy metal removal efficiency after the first treatment stage (i.e. the MBR effluent) was obtained at the lowest flux value of 16 L m−2 h−1. Ni, Pb, Zn, and As removals were measured to be equal to 96.9%, 98.3%, 98% and 8.5%, respectively. More important, the heavy metal concentrations were below the limit of detection after the GAC post-treatment; over 99% removal was achieved for all heavy metals. The adsorption of heavy metal ions onto the GAC may minimize biomass exposure to their toxicity, thereby creating the conditions for further improved MBR-GAC system performance. Coupling MBR technology with GAC adsorption seems a promising option for the effective treatment of wastewater containing heavy metals.


  • Adsorptive removal of cationic (BY2) dye from aqueous solutions onto Turkish clay: Isotherm, kinetic, and thermodynamic analysis

    by Onur Sözüdoğru, Baybars Ali Fil, Recep Boncukcuoğlu, Erdinç Aladağ, Sinan Kul

    The removal of Basic Yellow 2 (BY2), a cationic dye, from aqueous solution by using montmorillonite as adsorbent was studied in batch experiments. The effect of pH, agitation speed, adsorbent dosage, initial dye concentration ionic strength, and temperature on the removal of BY2 was also investigated. Langmuir, Freundlich, Temkin, and Dubinin–Radushkevich isotherms were applied to fit the adsorption data of BY2 dye. Equilibrium data were well described by the typical Langmuir adsorption isotherm. The maximum monolayer adsorption capacity was calculated as 434.196 mg g−1 from the Langmuir isotherm model. The adsorption data was fitted to both the pseudo-first-order, pseudo-second-order, Elovich, and intraparticle kinetic models, and the calculated values of the amount adsorbed at equilibrium (qe) by pseudo-second-order equations were found to be in good agreement with the experimental values. The thermodynamic factors were also evaluated. The entropy change (ΔS*) was negative, suggesting that the adsorption process decreases in entropy and enthalpy change (ΔH*) was positive which indicates endothermic nature. The positive ΔG* value confirms the un-spontaneity of the process. In addition, a semiempirical model was calculated from kinetic data.