Daichi Onomura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daichi Onomura has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Hiroaki Okamoto
Division of Virology, Department of Infection and Immunity, Jichi Medical University School of Medicine, 3311-1 Yakushiji, Shimotsuke 329-0498, Tochigi, Japan
1 shared publication Hiromichi Dansako
Okayama Univ, Dept Tumor Virol, Grad Sch Med Dent & Pharmaceut Sci, 2-5-1 Shikata Cho, Okayama 7008558, Japan
1 shared publication- Kazumoto Murata
Division of Virology, Department of Infection and Immunity, Jichi Medical University School of Medicine, Shimotsuke, Tochigi 329-0498, Japan
1 shared publication - Megumi Kato
Bio-Medical Standard Group, Research Institute for Material and Chemical Measurement, National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
1 shared publication Nobuyuki Kato
Okayama Univ, Dept Tumor Virol, Grad Sch Med Dent & Pharmaceut Sci, 2-5-1 Shikata Cho, Okayama 7008558, Japan
1 shared publication- Shinya Satoh
Department of Tumor Virology, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
1 shared publication
Latest Publications
- 22 January 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 418 (7) , 2125-2133
Development of a hypersensitive digital ELISA system for hepatitis B core antigen
Chronic hepatitis B (CHB) is a global health threat caused by the hepatitis B virus (HBV). Nucleos(t)ide analogs (NUCs) are the standard treatment for CHB patients with HBV replication. However, NUCs cannot eliminate covalently closed circular DNA (cccDNA), the template for HBV replication, from the nuclei of hepatocytes; hence, patients with CHB need life-long treatment with NUCs because HBV relapses easily upon cessation of NUCs because of the residual cccDNA. However, NUCs can be terminated by accurately monitoring the activity of the cccDNA. Despite the recent development of highly sensitive detection systems for HBV biomarkers, the detection accuracy remains poor, especially at lower concentrations. Therefore, it is desirable to develop more sensitive and reliable biomarkers that have a good correlation with cccDNA, even at lower concentrations. In this study, we developed a digital enzyme-linked immunosorbent assay (ELISA) system for detecting hepatitis B core antigen (HBcAg) using a pair of monoclonal antibodies. The digital ELISA system successfully detected 2.9 pg/mL, which can be converted to 58 aM HBcAg, and the sensitivity was approximately 1000 times higher than that of conventional ELISA. Furthermore, the influence of plasma and serum matrices on the sensitivity can be ignored if the concentrations of the matrices are 1% or less. In addition, the antibody-blocking assay indicated that the digital ELISA system reacted specifically with HBcAg, even in the presence of serum or plasma. Collectively, our highly sensitive digital ELISA system for detecting HBcAg is a potentially new approach for evaluating therapeutic strategies for CHB.
- 22 January 2026
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 418 (7) , 2125-2133
Development of a hypersensitive digital ELISA system for hepatitis B core antigen
Chronic hepatitis B (CHB) is a global health threat caused by the hepatitis B virus (HBV). Nucleos(t)ide analogs (NUCs) are the standard treatment for CHB patients with HBV replication. However, NUCs cannot eliminate covalently closed circular DNA (cccDNA), the template for HBV replication, from the nuclei of hepatocytes; hence, patients with CHB need life-long treatment with NUCs because HBV relapses easily upon cessation of NUCs because of the residual cccDNA. However, NUCs can be terminated by accurately monitoring the activity of the cccDNA. Despite the recent development of highly sensitive detection systems for HBV biomarkers, the detection accuracy remains poor, especially at lower concentrations. Therefore, it is desirable to develop more sensitive and reliable biomarkers that have a good correlation with cccDNA, even at lower concentrations. In this study, we developed a digital enzyme-linked immunosorbent assay (ELISA) system for detecting hepatitis B core antigen (HBcAg) using a pair of monoclonal antibodies. The digital ELISA system successfully detected 2.9 pg/mL, which can be converted to 58 aM HBcAg, and the sensitivity was approximately 1000 times higher than that of conventional ELISA. Furthermore, the influence of plasma and serum matrices on the sensitivity can be ignored if the concentrations of the matrices are 1% or less. In addition, the antibody-blocking assay indicated that the digital ELISA system reacted specifically with HBcAg, even in the presence of serum or plasma. Collectively, our highly sensitive digital ELISA system for detecting HBcAg is a potentially new approach for evaluating therapeutic strategies for CHB.
- 1 November 2020
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 533 (1) , 148-154
Identification of ribavirin-responsive cis-elements for GPAM suppression in the GPAM genome
- 1 November 2020
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 533 (1) , 148-154
Identification of ribavirin-responsive cis-elements for GPAM suppression in the GPAM genome