Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nabil Nassif has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Pasidu Dharmasena

    Department of Civil and Architectural Engineering and Construction Management, University of Cincinnati, Cincinnati, OH 45220, USA

    5 shared publications
  • Iffat Ridwana

    Department of Civil and Architectural Engineering and Construction Management, University of Cincinnati, Cincinnati, OH 45220, USA

    4 shared publications
  • Adam Nassif

    Department of Civil and Architectural Engineering and Construction Management, University of Cincinnati, Cincinnati, OH 45220, USA

    2 shared publications
  • Maya Arida

    Department of Civil, Architectural and Environmental Engineering North Carolina A&T State University Greensboro USA

    2 shared publications
  • Pejman Ebrahimi

    Department of Civil and Architectural Engineering and Construction Management, University of Cincinnati, Cincinnati, OH 45220, USA

    2 shared publications
  • Rand Talib

    Department of Civil and Architectural Engineering and Construction Management University of Cincinnati Cincinnati OH USA

    2 shared publications

Latest Publications

  • Open Access

    Performance and thermo-economic evaluation of solar-assisted recuperative organic Rankine cycle with thermal energy storage for data center waste-heat recovery

    by Asif Iqbal Turja, Y Siva Kumar Reddy, Nabil Nassif

    Technologies enabling the utilization of low-grade thermal resources are gaining attention, particularly for data centers (DCs) where continuous waste heat remains unutilized. This study investigates a solar-assisted recuperative organic Rankine cycle (ORC) integrated with a flat-plate collector (FPC) field and thermal energy storage (TES) for year-round waste-heat recovery (WHR). A full-year dynamic model was developed using typical meteorological year weather data and electric reliability council of Texas time-varying electricity pricing. The hybrid system couples a continuous 30 kW th DC waste-heat stream 262.80 MWh th (annually) with a 70 m 2 FPC field supplying 74.61 MWh th of useful solar heat with outlet temperatures between 53 °C–93 °C. Through dynamic solar preheating and TES buffering, the ORC evaporator receives a total annual heat input of 281.88 MWh th , generating 20.38 MWh e of net electrical energy at an annual average conversion efficiency of 7.23%. MM and Cyclopentane attained the highest ORC efficiencies among the assessed working fluids; however, R1233zd (E) was chosen as the optimal fluid due to its favorable safety and environmental profile. Economic assessment indicates positive annual net benefits under realistic conditions. Techno-economic analysis shows a minimum levelized cost of electricity of 0.081 $/kWh at the highest DC outlet temperature, with the solar equipped TES configuration outperforming both the baseline and solar-only ORC systems. Although demonstrated for a DC application, the proposed methodology and system-level insights are broadly applicable to other continuous low-grade WHR systems. Overall, the proposed system enhances operational flexibility, energy recovery, and cost competitiveness, demonstrating strong potential for practical low-temperature waste-heat utilization in DC applications.

  • Open Access

    Dynamic Multi-Output Stacked-Ensemble Model with Hyperparameter Optimization for Real-Time Forecasting of AHU Cooling-Coil Performance

    by Mahmudul Hasan, Pasidu Dharmasena, Nabil Nassif

    This study introduces a dynamic, multi-output stacking framework for real-time forecasting of HVAC cooling-coil behavior in air-handling units. The dynamic model encodes short-horizon system memory with input/target lags and rolling psychrometric features and enforces leakage-free, time-aware validation. Four base learners—Random Forest, Bagging (DT), XGBoost, and ANN—are each optimized with an Optuna hyperparameter tuner that systematically explores architecture and regularization to identify data-specific, near-optimal configurations. Their out-of-fold predictions are combined through a Ridge-based stacker, yielding state-of-the-art accuracy for supply-air temperature and chilled water leaving temperature (R2 up to 0.9995, NRMSE as low as 0.0105), consistently surpassing individual models. Novelty lies in the explicit dynamics encoding aligned with coil heat and mass-transfer behavior, physics-consistent feature prioritization, and a robust multi-target stacking design tailored for HVAC transients. The findings indicate that this hyperparameter-tuned dynamic framework can serve as a high-fidelity surrogate for cooling-coil performance, supporting set-point optimization, supervisory control, and future extensions to virtual sensing or fault-diagnostics workflows in industrial AHUs.


  • Open Access

    Hyperparameter Optimization of Neural Networks Using Grid Search for Predicting HVAC Heating Coil Performance

    by Yosef Jaber, Pasidu Dharmasena, Adam Nassif, Nabil Nassif

    Heating, Ventilation, and Air Conditioning (HVAC) systems represent a significant portion of global energy use, yet they are often operated without optimized control strategies. This study explores the application of deep learning to accurately model heating system behavior as a foundation for predictive control and energy-efficient HVAC operation. Experimental data were collected under controlled laboratory conditions, and 288 unique hyperparameter configurations were developed. Each configuration was tested three times, resulting in a total of 864 artificial neural network models. Five key hyperparameters were varied systematically: number of epochs, network size, network shape, learning rate, and optimizer. The best-performing model achieved a mean squared error of 0.469 and featured 17 hidden layers, a left-triangle architecture trained for 500 epochs with a learning rate of 5 × 10−5, and Adam as the optimizer. The results highlighted the importance of hyperparameter tuning in improving model accuracy. Future research should extend the analysis to incorporate cooling operation and real-world building operation data for broader applicability.


  • Open Access

    Application of Machine Learning Techniques for Predicting Heating Coil Performance in Building Heating Ventilation and Air Conditioning Systems

    by Adam Nassif, Pasidu Dharmasena, Nabil Nassif

    Heating systems in a building’s mechanical infrastructure account for a significant share of global building energy consumption, underscoring the need for improved efficiency. This study evaluates 31 predictive models—including neural networks, gradient boosting (XGBoost), bagging, and multiple linear regression (MLR) as a baseline—to estimate heating-coil performance. Experiments were conducted on a water-based air-handling unit (AHU), and the dataset was cleaned to eliminate illogical and missing values before training and validation. Among the evaluated models, neural networks, gradient boosting, and bagging demonstrated superior accuracy across various error metrics. Bagging offered the best balance between outlier robustness and pattern recognition, while neural networks showed strong capability in capturing complex relationships. An input-importance analysis further identified key variables influencing model predictions. Future work should focus on refining these modeling techniques and expanding their application to other HVAC components to improve adaptability and efficiency.


  • Open Access

    Development and Optimization of a Novel Damper Control Strategy Integrating DCV and Duct Static Pressure Setpoint Reset for Energy-Efficient VAV Systems

    by Pasidu Dharmasena, Nabil Nassif

    Climate change and the need to reduce greenhouse gas emissions have made energy efficiency in modern building operations more critical than ever. This study presents an improved damper control strategy for VAV systems, combined with techniques like DCV and duct static pressure adjustments, to optimize fan energy consumption. Using energy simulations and mathematical models, the research evaluates traditional HVAC operating methods against the proposed novel control approach across diverse climates. Findings show that the refined control integrations effectively adjust ventilation air volumes during low occupancy and achieve up to 47% savings in fan energy, cost, and CO2 savings annually. While DCV alone had minimal impact on fan energy, it significantly reduced the amount of outdoor air that required conditioning, thereby lowering cooling and heating demands. This research highlights the importance of integrating an advanced control strategy in building mechanical systems to reduce operational costs and environmental impact, contributing to sustainability and carbon reduction goals.


  • Open Access

    Testing, Validation, and Simulation of a Novel Economizer Damper Control Strategy to Enhance HVAC System Efficiency

    by Pasidu Dharmasena, Nabil Nassif

    Buildings account for over 40% of global carbon dioxide (CO2) emissions, with supply and return fans in air handling units consuming a significant portion of energy. To address this, researchers have explored innovative economizer damper control methods and identified the “split-signal” strategy, which optimizes supply airflow using a single damper as a promising approach. In this study, split-signal was further refined for practical application and energy simulation, aiming to demonstrate its effectiveness and encourage adoption in real-world building mechanical systems. Laboratory testing on chilled water variable air volume (VAV) system showed fan energy savings of 0.2–5% compared to traditional “three-coupled” control, depending on ventilation air proportions, and prevented reverse airflow. A statistical regression model, based on experimental data, was developed to predict energy savings and streamline comparisons. Energy simulations were conducted across various U.S. climate zones and revealed potential savings of 15–20% in energy use, operational costs, and CO2 emissions. With minimal financial investment, split-signal control offers a cost-effective solution to improve energy efficiency and reduce environmental impact, promoting its adoption in real-world building applications.


  • Open Access

    Solutions to Achieve High-Efficient and Clean Building HVAC Systems

    by Pejman Ebrahimi, Iffat Ridwana, Nabil Nassif

    The building sector accounts for a substantial amount of energy consumption, resulting in higher carbon emissions and environmental impact worldwide. Electrification and energy efficiency in building systems can be the key to decarbonization in buildings. This research proposes new heating and cooling loops consisting of heat pumps to lower natural gas usage in building systems. Typical chillers and boilers in the cooling and heating loops are replaced with heat pumps to serve the loads and maintain thermal comfort in the building. In addition, a new optimal supply air temperature (SAT) reset strategy is also implemented with the proposed configuration for better system performance. A large multi-zone office building is simulated as a case study to measure the conventional system’s electricity and natural gas consumption and the proposed design. Even with heat pumps that use electricity as the energy source, electricity consumption is reduced by 3.3% to 11.8% in different climate zones for the proposed system. On the other hand, 10.2% to 67% lower natural gas is consumed when the proposed system and the optimal SAT reset are utilized. The carbon emission is also reduced by 10.8% to 38% compared to the conventional system. The results show that the proposed design and optimization strategy can lead to significant energy and cost savings in conjunction with lower carbon emissions.


  • Open Access

    New Optimal Supply Air Temperature and Minimum Zone Air Flow Resetting Strategies for VAV Systems

    by Nabil Nassif, Mostafa Tahmasebi, Iffat Ridwana, Pejman Ebrahimi

    Buildings account for a large portion of the total energy use in the US; therefore, improving the operation of typical variable-air-volume (VAV) systems in buildings can provide a tremendous economic opportunity. ASHRAE Guideline 36 recommends a resetting strategy for supply air temperature (SAT) for VAV systems based on outside air temperature. However, this strategy may not produce optimal performance, particularly when simultaneous cooling and heating occurs in zones. In addition, there is no strategy recommended in the Guideline to reset the zone minimum airflow set point in a single-duct VAV terminal unit with reheat, although this setpoint has a great impact on zone reheat requirements and ventilation efficiency. Thus, this paper introduces new strategies to reset both the SAT and zone minimum airflow rate set points to improve the efficiency of typical VAV systems. The strategies were tested under various conditions through experiments performed in fully instrumented VAV systems located in the HVAC lab at the University of Cincinnati. The experiments were conducted on a chilled-water VAV system that serves three controlled zones with hot-water reheat VAV boxes controlled by a typical commercial BACnet web-based building automation system BAS. The simulation studies were performed using the building energy simulation software EnergyPlus to evaluate the strategies at a larger scale in various locations. The simulation results show that the proposed resetting strategies can provide fan energy savings between 1.6% and 5.7% and heating load savings between 7.7% to 33.7%, depending on the location. The laboratory testing shows that the proposed strategies can provide stable control performance in actual systems as well as achieving the anticipated reheat and fan energy savings. The result offers significant improvements that can be implemented in the Guideline for single-duct VAV system operation and control.


  • Open Access

    “Demand Control” an Innovative Way of Reducing the HVAC System’s Energy Consumption

    by Rand Talib, Nabil Nassif

    According to EIA, the Heating Ventilation and Air Conditioning (HAVC) systems account for about 25% of the U.S.’s total commercial building’s energy use. Therefore, advanced modeling and optimization methods of the system components and operation offer great ways to reduce energy consumption in all types of buildings and mainly commercial buildings. This research introduced an innovative integrated two-level optimization technique for the HVAC system to reduce the total energy consumption while improving the indoor thermal comfort level. The process uses actual system performance data collected for the building automation systems (BAS) to create accurate component modeling and optimization process as the first level of optimization (MLO). Artificial neural networks were chosen to be the tool used to serve the process of modeling. The second optimization level utilizes the whole system-level optimization technique (SLO) using a genetic algorithm (G.A.). The proposed two-levels optimization technique will optimize the system setpoints, the supply air temperature, duct static pressure, minimum zone air flowrates, and minimum outdoor air ventilation rate. The proposed technique has contributed to the field of modeling and optimization of HVAC systems through several new contributions. (1) Implementing the demand control methodology with the optimization process to modify the electricity consumption power profile when the demand signal is received. (2) Implement the occupancy schedule inputs into the optimization process to adjust the ventilation airflow rates accordingly. (3) Implement the real-time zone occupancy sensor readings and adjust the zone’s ventilation flowrates and minimum flowrates. (4) Lastly, implementing the method of zone minimum air flowrates setpoint rests to reduce reheat requirements. The proposed optimization process was tested and validated, resulting in savings in the total energy consumed by the chilled water VAV system by 13.4%, 22.4 %, followed by 31% for July, February, and October, respectively.


  • Open Access

    Improving Building Energy Performance Using Dual VAV Configuration Integrated with Dedicated Outdoor Air System

    by Nabil Nassif, Iffat Ridwana

    As building systems account for almost half of the total energy consumed by the building sector to provide space heating, cooling, and ventilation, efficiently designing these systems can be the key to energy conservation in buildings. Dual VAV systems with an effective control strategy can substantially reduce the energy consumption in buildings, providing a significant scope of further research on this system configuration. This paper proposes to utilize the warm air duct of the dual VAV system as a dedicated outdoor air (DOA) unit when no heating is required, which allows the cooling load to be effectively distributed between two ducts. A specific control sequence is proposed with different supply air temperature reset strategies to estimate the heating, cooling loads, and fan power energy consumption of the proposed system. A simple two-zone office building is taken as a preliminary case study to simulate the airflow rates and fan power of a single duct VAV and proposed dual VAV systems to illustrate the concept. Finally, a larger multi-zone office building is simulated to measure the annual heating, cooling loads, and fan power energy and compare the energy savings among the systems. The results show significant fan power reduction ranging from 1.7 to 9% and notable heating energy reduction up to 76.5% with a small amount of cooling load reduction varying from 0.76 to 2.56% depending on the different locations for the proposed dual VAV systems. Further energy savings from different supply air temperature reset strategies demonstrate the opportunity of employing them according to climates and case studies. The proposed dual VAV system proves to have the potential to be adapted in buildings for the purpose of sustainability and energy savings.