CKChatchai Kunavisarut

Chatchai Kunavisarut

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chatchai Kunavisarut has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Tim Joda

    Clinic of Reconstructive Dentistry, Center for Dental Medicine University of Zurich Zürich Switzerland

    2 shared publications
  • Akarin Santivitoonvong

    Education Program in Implant Dentistry Mahidol University Bangkok Thailand

    1 shared publication
  • Jira Kitisubkanchana

    Affiliations Osaka University Graduate School of Dentistry, Osaka, Japan, Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

    1 shared publication
  • Nopparat Suksod

    Affiliation Faculty of Dentistry, Mahidol University, Bangkok, Thailand

    1 shared publication
  • Rawikorn Krongvanitchayakul

    Department of Advanced General Dentistry, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

    1 shared publication
  • Sarunya Chaikantha

    Department of Oral and Maxillofacial Radiology Mahidol University Bangkok Thailand

    1 shared publication

Latest Publications

  • Open Access

    Retention of zirconia crown to oxidized titanium base abutment: Experimental research

    by Rawikorn Krongvanitchayakul, Chatchai Kunavisarut

    Statement of problem: To separate the crown from the titanium base abutment, by using heat, caused oxidization of the titanium base abutment. The effect of this procedure on the retention of a crown is unclear. Purpose: To compare the resin bond strength and failure type between zirconia crowns and titanium base abutments utilizing four different surface treatments. Surface roughness and morphology of each surface treatment were also investigated. Material and methods: Forty titanium base abutments (Variobase®) were divided into four groups, 1. Control, 2. Air abraded, 3. Oxidized, and 4. Oxidized-air abraded. Oxidized and oxidized-air abraded groups were debonded from zirconia crowns using constant dry heat at 500 ˚C. For air abraded and oxidized-air abraded groups (after oxidization), the titanium base abutments were air abraded with Al3O2. After cleaning, one specimen of each group was investigated under a non-contact profilometer (50x), then the same samples were investigated under SEM at 25,300,500,1000 magnification and EDS at 30kV of accelerated voltage. All specimens were then cemented (RelyX Ultimate). After aging, with thermocycling under 5C° to 55C°,120 seconds dwell time for 5,000 cycles, bond strength was tested and statistical differences were calculated with One-way ANOVA (p-value <0.05) follow by Tukey test. All separated crowns and titanium base abutments were investigated under a light microscope (20x), using fisher’s exact test for correlation of the failure types. Results: There was a significant difference in the mean value of tensile bond strength among the control and test groups. Comparisons between control(237.6±46.3N) and oxidized(241.7±46.3N) showed statistically different values from air abraded(372.9±113.2N) when assembled using different surface treatments of the titanium-based abutments. (p-value<0.005) As for failure type, there were statistically significant differences between control versus air abraded, control versus oxidized-air abraded, oxidized versus air abraded, and oxidized versus oxidized-air abraded. (p-value<0.001) The titanium surface morphology shown from the profilometer and SEM was coordinated. Control (Ra 333.8nm) and oxidized (Ra 321.0nm) groups surfaces showed smooth, corrugated surfaces, meanwhile air abraded (Ra 476.0nm) and oxidized-air abraded (Ra 423.8nm) groups showed rough, rugged surfaces. Conclusion: Heat oxidization of titanium-based abutments did not adversely affect tensile bond strength or the failure mode and surface roughness between titanium base abutments and zirconia crowns. However, air abrasion of the titanium surface increased surface roughness and retentive strength. Clinical implications: The titanium base abutments that were oxidized under heat treatment did not have an effect on crown retention. Thoroughly air abraded the titanium abutment prior to cementation can increase cement bond strength.


  • Patient‐reported outcome measures comparing static computer‐aided implant surgery and conventional implant surgery for single‐tooth replacement: A randomized controlled trial

    by Chatchai Kunavisarut, Akarin Santivitoonvong, Sarunya Chaikantha, Suchaya Pornprasertsuk‐Damrongsri, Tim Joda

    Objective: To compare static computer‐aided implant surgery (s‐CAIS) and conventional implant surgery (CIS) for single‐tooth replacement in posterior sites in terms of patient‐reported outcome measures (PROMs).Methods: Forty patients were divided into two groups for treatment with s‐CAIS (Test) and CIS (Control). Patients’ anxiety level was measured using the modified dental anxiety score before implant surgery. After surgery, patients completed two questionnaires for 7 days. The first questionnaire assessed pain level using a visual analog scale (VAS) and the incident rate of pain using a 5‐point Likert scale; analgesic intake was also recorded. The second questionnaire investigated patients’ oral health‐related quality of life (OHRQoL) including postoperative symptoms, oral function, and daily activity. The difference between data was compared at significance level (α = 0.05).Results: There was no statistically significant difference in pretreatment dental anxiety level, postoperative pain scores, and OHRQoL between treatment groups. Overall, mild or moderate dental anxiety was reported by 70% and 20% of patients, respectively. Pain score was significantly reduced by postoperative Day 3 in the test group and Day 4 in the control group, compared with baseline. Both groups significant reduced analgesic intake by postoperative Day 5. Most OHRQoL‐related complaints subsided approximately 3 days after surgery.Conclusions: Overall, PROMs between s‐CAIS and CIS were not significantly different for the single‐tooth implant surgery in the posterior area. Postoperative symptoms after implant surgery still inevitably occurred, reflecting the normal process of oral wound healing.


  • Open Access

    Accuracy of computer-guided implantation in the placement of one-piece ceramic dental implants in the anterior region: A prospective clinical study

    by Nopparat Suksod, Chatchai Kunavisarut, Jira Kitisubkanchana

    Placement of one-piece ceramic dental implants requires precision, which can be enhanced by using a computer-guided system. This prospective clinical study examines the accuracy of partially guided implantation in the placement of one-piece ceramic implants in the anterior region. One-piece ceramic dental implants were placed in 20 patients who were missing a central or lateral incisor. Partially guided dental implant placements were performed in all cases. The deviations in the implant positions were analyzed by superimposing post-operative cone beam computed tomography images over pre-operative treatment planning images. The results were reported as deviations (mean ± standard deviation) for three aspects (3D offset, mesio-distal, labio-lingual, and apico-coronal) and in three dimensions (the angle, coronal, and apical parts). Implants were successfully placed in 20 patients. The mean angular deviation was 4.23±1.84°, whereas the mean coronal 3D offset was 0.98±0.48 mm, and the mean apical 3D offset was 1.57±0.46 mm. A prospective clinical study involving 20 patients was conducted to measure the accuracy of computer-guided implantation of one-piece ceramic dental implants. Accuracy was determined by comparing the planned implant position to the actual position. Greater accuracy can be expected at the coronal part than at the apical part. The coronal 3D offset was found to be the most accurate.