Morten Homilius
Research Subjects
Morten Homilius has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Torben Bæk Hansen
Department of Orthopedics, University Clinic for Hand, Hip and Knee Surgery, Gødstrup Hospital, Herning; Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark
3 shared publications - Maiken Stilling
Aarhus University Hospital
2 shared publications A. L. Amstrup
Department of Radiology, Regional Hospital Holstebro, Denmark
1 shared publication- Dovydas Vainorius
Department of Orthopaedics, Gødstrup Regional Hospital, Herning, Denmark
1 shared publication - Lone Kirkeby
University Clinic of Hand, Hip and Knee Surgery, Regional Hospital West Jutland, Holstebro, Denmark
1 shared publication - Ole Gade Sørensen
Sports Traumatology, Orthopedic Department Aarhus University Hospital Jylland Denmark
1 shared publication
Latest Publications
- Open Access
- 6 July 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (7) , 507-515
Less early subsidence of cemented Exeter short stems compared with cemented Exeter standard stems in Dorr type A femurs
Aims: The Exeter short stem was designed for patients with Dorr type A femora and short-term results are promising. The aim of this study was to evaluate the minimum five-year stem migration pattern of Exeter short stems in comparison with Exeter standard stems.Methods: In this case-control study, 25 patients (22 female) at mean age of 78 years (70 to 89) received cemented Exeter short stem (case group). Cases were selected based on Dorr type A femora and matched first by Dorr type A and then age to a control cohort of 21 patients (11 female) at mean age of 74 years (70 to 89) who received with cemented Exeter standard stems (control group). Preoperatively, all patients had primary hip osteoarthritis and no osteoporosis as confirmed by dual X-ray absorptiometry scanning. Patients were followed with radiostereometry for evaluation of stem migration (primary endpoint), evaluation of cement quality, and Oxford Hip Score. Measurements were taken preoperatively, and at three, 12, and 24 months and a minimum five-year follow-up.Results: At three months, subsidence of the short stem -0.87 mm (95% confidence interval (CI) -1.07 to -0.67) was lower compared to the standard stem -1.59 mm (95% CI -1.82 to -1.36; p < 0.001). Both stems continued a similar pattern of subsidence until five-year follow-up. At five-year follow-up, the short stem had subsided mean -1.67 mm (95% CI -1.98 to -1.36) compared to mean -2.67 mm (95% CI -3.03 to -2.32) for the standard stem (p < 0.001). Subsidence was not influenced by preoperative bone quality (osteopenia vs normal) or cement mantle thickness.Conclusion: The standard Exeter stem had more early subsidence compared with the short Exeter stem in patients with Dorr type A femora, but thereafter a similar migration pattern of subsidence until minimum five years follow-up. Both the standard and the short Exeter stems subside. The standard stem subsides more compared to the short stem in Dorr type A femurs. Subsidence of the Exeter stems was not affected by cement mantle thickness.Cite this article: Bone Jt Open 2023;4(7):507–515.
- 6 July 2023
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (7) , 507-515
Open AccessLess early subsidence of cemented Exeter short stems compared with cemented Exeter standard stems in Dorr type A femurs
Aims: The Exeter short stem was designed for patients with Dorr type A femora and short-term results are promising. The aim of this study was to evaluate the minimum five-year stem migration pattern of Exeter short stems in comparison with Exeter standard stems.Methods: In this case-control study, 25 patients (22 female) at mean age of 78 years (70 to 89) received cemented Exeter short stem (case group). Cases were selected based on Dorr type A femora and matched first by Dorr type A and then age to a control cohort of 21 patients (11 female) at mean age of 74 years (70 to 89) who received with cemented Exeter standard stems (control group). Preoperatively, all patients had primary hip osteoarthritis and no osteoporosis as confirmed by dual X-ray absorptiometry scanning. Patients were followed with radiostereometry for evaluation of stem migration (primary endpoint), evaluation of cement quality, and Oxford Hip Score. Measurements were taken preoperatively, and at three, 12, and 24 months and a minimum five-year follow-up.Results: At three months, subsidence of the short stem -0.87 mm (95% confidence interval (CI) -1.07 to -0.67) was lower compared to the standard stem -1.59 mm (95% CI -1.82 to -1.36; p < 0.001). Both stems continued a similar pattern of subsidence until five-year follow-up. At five-year follow-up, the short stem had subsided mean -1.67 mm (95% CI -1.98 to -1.36) compared to mean -2.67 mm (95% CI -3.03 to -2.32) for the standard stem (p < 0.001). Subsidence was not influenced by preoperative bone quality (osteopenia vs normal) or cement mantle thickness.Conclusion: The standard Exeter stem had more early subsidence compared with the short Exeter stem in patients with Dorr type A femora, but thereafter a similar migration pattern of subsidence until minimum five years follow-up. Both the standard and the short Exeter stems subside. The standard stem subsides more compared to the short stem in Dorr type A femurs. Subsidence of the Exeter stems was not affected by cement mantle thickness.Cite this article: Bone Jt Open 2023;4(7):507–515.
- Open Access
- 1 April 2018
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. ume 13, 615-621
Good function and high patient satisfaction at mean 2.8 years after dual mobility THA following femoral neck fracture: a cross-sectional study of 124 patients
Aims: Our aim was to investigate function, health status and satisfaction in patients treated with primary dual mobility (DM) total hip arthroplasty (THA) after displaced femoral neck fracture (FNF). Patients and methods: From 2005–2011, 414 consecutive FNF patients received Saturne DM THA. At a minimum of 1-year follow-up, 124 (95 women) were evaluated with Oxford Hip Score (OHS), Harris Hip Score (HHS), health-related quality of life (HRQoL) measure (EQ-5D) and two functional tests: Timed Up and Go (TUG) and Sit to Stand 10 times (STS). The FNF patients were matched 1:2 by age, sex and surgery date with patients receiving THA due to osteoarthrosis (OA group) and 1-year OHS and EQ5D were compared. FNF patients were matched by age and sex with the general population index (GPI) for EQ-5D comparison. Results: Patient age at surgery after FNF was mean 74.8 (range 30–92) years. At mean follow-up of 2.8 (range 1.0–7.7) years, mean EQ-5D score was 0.79 (SD 0.15) in the FNF group, which was similar to the matched GPI (p = 0.4), but lower (p = 0.014) compared to the OA group. Mean OHS was 36.4 (SD 9.5) in the FNF group and 38.4 (SD 7.2) in the OA group (p = 0.18). HHS in the FNF group was 78.7 (SD 15.5). Mean TUG time was 13.5 (SD 4.9) secs, and mean STS was 37.9 (SD 15.3) secs. Eighty nine percent (n = 111) of FNF patients were satisfied with the operation result. Conclusion: DM THA following displaced FNF provides a good functional result and quality of life in addition to high patient satisfaction.
- 1 April 2018
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. ume 13, 615-621
Open AccessGood function and high patient satisfaction at mean 2.8 years after dual mobility THA following femoral neck fracture: a cross-sectional study of 124 patients
Aims: Our aim was to investigate function, health status and satisfaction in patients treated with primary dual mobility (DM) total hip arthroplasty (THA) after displaced femoral neck fracture (FNF). Patients and methods: From 2005–2011, 414 consecutive FNF patients received Saturne DM THA. At a minimum of 1-year follow-up, 124 (95 women) were evaluated with Oxford Hip Score (OHS), Harris Hip Score (HHS), health-related quality of life (HRQoL) measure (EQ-5D) and two functional tests: Timed Up and Go (TUG) and Sit to Stand 10 times (STS). The FNF patients were matched 1:2 by age, sex and surgery date with patients receiving THA due to osteoarthrosis (OA group) and 1-year OHS and EQ5D were compared. FNF patients were matched by age and sex with the general population index (GPI) for EQ-5D comparison. Results: Patient age at surgery after FNF was mean 74.8 (range 30–92) years. At mean follow-up of 2.8 (range 1.0–7.7) years, mean EQ-5D score was 0.79 (SD 0.15) in the FNF group, which was similar to the matched GPI (p = 0.4), but lower (p = 0.014) compared to the OA group. Mean OHS was 36.4 (SD 9.5) in the FNF group and 38.4 (SD 7.2) in the OA group (p = 0.18). HHS in the FNF group was 78.7 (SD 15.5). Mean TUG time was 13.5 (SD 4.9) secs, and mean STS was 37.9 (SD 15.3) secs. Eighty nine percent (n = 111) of FNF patients were satisfied with the operation result. Conclusion: DM THA following displaced FNF provides a good functional result and quality of life in addition to high patient satisfaction.
- 4 April 2012
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 38 (2) , 187-191
Computed tomography improves intra-observer reliability, but not the inter-observer reliability of the Eaton–Glickel classification
This study aimed to evaluate whether computed tomography improves the intra- and inter-observer reliability of the Eaton–Glickel classification of trapeziometacarpal joint osteoarthritis. The osteoarthritis of the trapeziometacarpal joint was evaluated with conventional radiographs and computed tomography by two hand surgeons, two registrars and one radiologist in 50 hands of 43 patients (12 male and 31 female) who had a median age of 60 years (46–80). Using plain radiographs, we found a mean intra-observer reliability of 0.54 (0.51–0.74), and the intra-observer reliability was improved to 0.76 (0.64–0.86) using computed tomography. Using plain radiographs, the mean inter-observer reliability was poor at 0.17 (0.04–0.51) and did not improve using computed tomography with a mean inter-observer reliability of 0.22 (0.02–0.38). In particular, the agreement in the distinction between Eaton–Glickel stage III and IV and the evaluation of the degenerative changes in the scaphotrapezio joint was low using computed tomography-scans. The detection of bone cysts on computed tomography was more precise than on plain radiographs.
- 4 April 2012
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 38 (2) , 187-191
Computed tomography improves intra-observer reliability, but not the inter-observer reliability of the Eaton–Glickel classification
This study aimed to evaluate whether computed tomography improves the intra- and inter-observer reliability of the Eaton–Glickel classification of trapeziometacarpal joint osteoarthritis. The osteoarthritis of the trapeziometacarpal joint was evaluated with conventional radiographs and computed tomography by two hand surgeons, two registrars and one radiologist in 50 hands of 43 patients (12 male and 31 female) who had a median age of 60 years (46–80). Using plain radiographs, we found a mean intra-observer reliability of 0.54 (0.51–0.74), and the intra-observer reliability was improved to 0.76 (0.64–0.86) using computed tomography. Using plain radiographs, the mean inter-observer reliability was poor at 0.17 (0.04–0.51) and did not improve using computed tomography with a mean inter-observer reliability of 0.22 (0.02–0.38). In particular, the agreement in the distinction between Eaton–Glickel stage III and IV and the evaluation of the degenerative changes in the scaphotrapezio joint was low using computed tomography-scans. The detection of bone cysts on computed tomography was more precise than on plain radiographs.