Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuchao Yan has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fundus Spectral Imaging: From Optical Systems to Clinical Applications

    by Yingchao Shi, Keke Zhang, Luming Zhang, Yuchao Yan, Wenli Li, Jiancun Zhao, Yizhen Tong, Yiting Yu, Yan Gong

    Fundus spectral imaging (FSI) integrates spatial and spectral information, providing a noninvasive alternative for structural and functional fundus examinations. It has demonstrated significant potential in detecting diseases such as choroidal tumors. However, a systematic review comprehensively summarizing the progress of FSI from optical system construction to clinical applications remains lacking, hindering its further development and clinical adoption. This review first examines the optical principles underlying FSI, including the optical model of the human eye and the optical components of fundus camera systems. Subsequently, it discusses technical strategies for implementing FSI, including various hardware upgrades based on existing fundus camera systems. Furthermore, this paper systematically evaluates various spectral imaging techniques applicable to FSI, classifying them into targeted-point spectral imaging (TPSI) and wide-field spectral imaging (WFSI), with the latter further divided into scanning, staring, transformed, and snapshot modes. The performance, advantages, and limitations of these methods are analyzed in detail. Additionally, the clinical applications of FSI are explored through specific case studies, highlighting its role in both structural and functional fundus assessments. Finally, this review summarizes the challenges facing FSI and explores future directions. This review aims to provide valuable insights for researchers and clinicians in the fields of optical imaging and ophthalmology.


  • Flexible Artificial Skin With Multifunctional Detection of Temperature and Flow

    by Jiayao Li, Yuchao Yan, Jinjun Deng, Binghe Ma, Weizheng Yuan, Yiting Yu

    The thermal effect of human skin was concerned in this paper, and here we reported a flexible artificial skin for detection of air temperature and flow shear stress. The flexible artificial skin was consisting of two overlapped functional devices. The bottom layer heater detected the flow shear stress and air temperature through force convection heat transfer process, while the upper layer temperature sensor sensed a coupling temperature. This coupled working mode simulated the perception system of human skin. The neural network algorithm was used to train the relationship model of coupled multi physical parameters, and the flow shear stress and air temperature were decoupled. The flexible artificial skin achieved resolutions of 0.915 Pa to flow shear stress and 0.068 °C to air temperature. Moreover, the temperature compensation of the heater could be omitted by this coupling measurement method. This kind of flexible artificial skin opened new avenues for the intelligent robot, artificial skin and multilayer composite flexible electronics.

  • Open Access

    Highly Sensitive Flow Sensor Based on Flexible Dual-Layer Heating Structures

    by Yu-Chao Yan, Cheng-Yu Jiang, Run-Bo Chen, Bing-He Ma, Jin-Jun Deng, Shao-Jun Zheng, Jian Luo

    Hot film sensors detect the flow shear stress based on the forced convection heat transfer to the fluid. Current hot film sensors have been significantly hindered by the relatively low sensitivity due to the massive heat conduction to the substrate. This paper describes the design, fabrication, simulation, and testing of a novel flow sensor with dual-layer hot film structures. More specifically, the heat conduction was insulated from the sensing heater to the substrate by controlling both sensing and guarding heaters working at the same temperature, resulting in a higher sensitivity. The experiment and simulation results showed that the sensitivity of the dual-layer hot film sensor was significantly improved in comparison to the single-layer sensor. Additionally, the dual-layer sensor was designed and fabricated in an integrated, flexible, and miniaturized manner. Its small size makes it an excellent candidate for flow detection.


  • Fabrication and static calibration of double-layer thermal film sensor for fluid wall shear stress measurement

    by Jinjun Deng, Shaojun Zheng, Yuchao Yan, Runbo Chen, Jian Luo, Binghe Ma

    A double-layer flexible sensor array with an active thermal insulation method for fluid wall shear stress was fabricated in this study and evaluated experimentally. Static calibration of the sensor was studied in both wind and water tunnels and the experimental results reveal that the sensor’s static performance was improved by active thermal insulation. Compared to single-layer methods, the static sensitivity of the proposed double-layer sensor is increased by approximately 48% in a wind tunnel and 13% in a water tunnel. Additionally, consistent deviations in the static calibration coefficients of sensors with different basic parameters were clearly compensated in the wind tunnel. The calibration coefficient deviation of the sensors was reduced from 57% in single-layer mode to 5% in double-layer mode.


  • Open Access

    Improving Long-Term Stability of a Resonant Micro-Optic Gyro by Reducing Polarization Fluctuation

    by Huilian Ma, Yuchao Yan, Yan Chen, Zhonghe Jin

    Resonant micro-optic gyros (RMOGs) with waveguide-type ring resonators are promising candidates for applications demanding small, light, and robust gyros. However, the nonzero bias at the gyro output fluctuates in terms of both the bias and the bias stability, owing to the temperature variations of the waveguide-type resonator. In particular, the temperature sensitivity of the bias stability varies greatly depending on the temperature. This paper intends to reveal that these observed fluctuations arise from the temperature-dependent polarization fluctuation. We will investigate how such polarization fluctuation affects the bias of the gyro-output through the state of polarization of the input beam, the polarization characteristics of the resonator coupler, and the temperature variation of the resonator. Both our numerical simulation and experimental verification are carried out, which, for the first time to our best knowledge, demonstrate that the long-term stability of the RMOG can be significantly improved by optimizing the temperature of the waveguide resonator.