HLHenryk Lamparczyk

Henryk Lamparczyk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Henryk Lamparczyk has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The bioequivalence study of baclofen and lioresal tablets using capillary electrophoresis

    by Piotr Kowalski, Aleksandra Chmielewska, Lucyna Konieczna, Ilona Olȩdzka, Paweł K. Zarzycki, Henryk Lamparczyk

    A simple and robust analytical method for rapid separation and sensitive quantification of baclofen in human plasma by capillary electrophoresis technique was developed. Electrophoretic separation was optimized and successfully performed using simple sodium tetraborate aqueous solution. Observed detection limit in biological material was 10 ng. Using UV detection at 200 nm excellent linearity (r = 0.999) was observed over the concentration range from 0.025 to 1.0 µg mL−1. The described method has been validated and applied to the quantitative determination of baclofen in human plasma. The bioavailability of Baclofen (Polpharma) and Lioresal (Novartis) in 18 healthy volunteers was investigated. The results indicate bioequivalence of the reference and Baclofen preparations. Copyright © 2003 John Wiley & Sons, Ltd.


  • RP‐HPLC method with electrochemical detection for the determination of metoclopramide in serum and its use in pharmacokinetic studies

    by Henryk Lamparczyk, Aleksandra Chmielewska, Lucyna Konieczna, Alina Plenis, Paweł K. Zarzycki

    A rapid and sensitive reversed‐phase high performance liquid chromatographic method has been developed for the determination of metoclopramide in serum. The assay was performed after single extraction with ethyl ether using methyl parahydroxybenzoate as internal standard. Chromatographic separations were performed on C18 stationary phase with a mobile phase composed of methanol–phosphate buffer pH 3 (30:70 v/v). Analytes were detected electrochemically. The quantification limit for metoclopramide in serum was 2 ng mL−1. Linearity of the method was confirmed in the range of 5–120 ng mL−1 (correlation coefficient 0.9998). Within‐day relative standard deviations (RSDs) ranged from 0.3 to 5.5% and between‐day RSDs from 0.8 to 6.0%. The analytical method was successfully applied for the determination of pharmacokinetic parameters after ingestion of 10 mg dose of metoclopramide. Studies were performed on 18 healthy volunteers of both sexes. Copyright © 2001 John Wiley & Sons, Ltd.