Kennedy Mang'Era
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kennedy Mang'Era has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Chris Saunders
Acsion Industries
1 shared publication David Douglas
Radiology, Faculty of Medicine, University of Manitoba, GA216-820 Sherbrook Street, Winnipeg, MB, Canada R3T 2N2
1 shared publicationDavid Greenberg
1 shared publicationDerek Wong
Radiopharmacy, Health Sciences Centre, GC219-820 Sherbrook Street, Winnipeg, MB, Canada R3A1R9,; Faculty of Pharmacy, University of Manitoba, 750 McDermot Avenue, Winnipeg, MB, Canada R3E 0T5
1 shared publication- Eric Pellerin
Radiopharmaceuticals Research Group, Health Sciences Centre
1 shared publication Jared Fitzpatrick
Radiopharmaceuticals Research Group, Health Sciences Centre, Winnipeg, Manitoba
1 shared publication
Latest Publications
- 28 February 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 305 (1) , 79-85
Processing and evaluation of linear accelerator-produced 99Mo/99mTc in Canada
- 28 February 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 305 (1) , 79-85
Processing and evaluation of linear accelerator-produced 99Mo/99mTc in Canada
- Open Access
- 12 December 2014
- Published by Canadian Center of Science and Education in Applied Physics Research
- Vol. 7 (1) , p72
Recovery Profiles of Molybdate Solutions Through Varying DowexTM-1 Resin Amounts, and Translation to Mo99/Tc99m Separation
The influence of molybdenum concentration and resin amount on the retention of molybdenum in 5M NaOH on Dowex TM -1 columns with successive elutions of saline and tetrabutylammonium bromide (TBAB) was investigated. Studies were performed with 45, 75, 125, 175, or 250 mg of resin and at 100 and 250 mg/mL molybdenum concentrations. Initial pass-through molybdenum recoveries from the column were 97.8% at 100 mg/L and 97.8% at 250 mg/mL (n=3 at each resin amount). Molybdenum breakthrough into TBAB solvent was low for all five resin amounts. Values for the 100mg/mL solution were 0.33 – 3.73 ppm, representing 0.0002 - 0.0014% of the original molybdenum load; and were 0.96 - 11.27 ppm for the 250 mg/mL solution, equivalent to 0.0002 – 0.0027%. Breakthrough into TBAB is generally higher with higher resin amounts for both the 100 mg/ml and 250 mg/mL molybdenum concentrations. The resin can be used for high molybdenum loads, with care taken to optimize the relative resin-solute amounts.
- 12 December 2014
- Published by Canadian Center of Science and Education in Applied Physics Research
- Vol. 7 (1) , p72
Open AccessRecovery Profiles of Molybdate Solutions Through Varying DowexTM-1 Resin Amounts, and Translation to Mo99/Tc99m Separation
The influence of molybdenum concentration and resin amount on the retention of molybdenum in 5M NaOH on Dowex TM -1 columns with successive elutions of saline and tetrabutylammonium bromide (TBAB) was investigated. Studies were performed with 45, 75, 125, 175, or 250 mg of resin and at 100 and 250 mg/mL molybdenum concentrations. Initial pass-through molybdenum recoveries from the column were 97.8% at 100 mg/L and 97.8% at 250 mg/mL (n=3 at each resin amount). Molybdenum breakthrough into TBAB solvent was low for all five resin amounts. Values for the 100mg/mL solution were 0.33 – 3.73 ppm, representing 0.0002 - 0.0014% of the original molybdenum load; and were 0.96 - 11.27 ppm for the 250 mg/mL solution, equivalent to 0.0002 – 0.0027%. Breakthrough into TBAB is generally higher with higher resin amounts for both the 100 mg/ml and 250 mg/mL molybdenum concentrations. The resin can be used for high molybdenum loads, with care taken to optimize the relative resin-solute amounts.
- 1 April 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 86, 57-62
Evaluation of alternative rapid thin layer chromatography systems for quality control of technetium-99m radiopharmaceuticals
- 1 April 2014
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 86, 57-62
Evaluation of alternative rapid thin layer chromatography systems for quality control of technetium-99m radiopharmaceuticals
- 1 April 2005
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 26 (4) , 375-381
Molecular-size fractionation of pentastarch, radiolabelling with 99mTc, and evaluation of biological behaviour in mice
Pentastarch is used clinically as a plasma volume expander for the management of substantial blood loss. 99mTc labelled pentastarch may be useful as a diagnostic agent in place of 99mTc labelled red blood cells. Commercial pentastarch (PS; molecular weight (MW) 240 kDa) was separated according to molecular size by using chromatography, and the fractions were pooled as small (MW 128 kDa), medium (MW 277 kDa) and large (MW 510 kDa) pentastarch. We studied the effect of various physicochemical parameters on the efficiency of radiolabelling with 99mTc and on the stability of the products, and evaluated the biological properties of the 99mTc labelled preparations. We developed an optimised kit formulation containing 3.25 mg pentastarch and 0.13 mg gentisic acid that can be reliably labelled with 99mTc at pH 6.6–8.2 with good stability. In mice, the 99mTc labelled medium pentastarch showed the more favourable blood retention properties (56% of initial blood activity is retained after 3 h) with lower liver levels.
- 1 April 2005
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 26 (4) , 375-381
Molecular-size fractionation of pentastarch, radiolabelling with 99mTc, and evaluation of biological behaviour in mice
Pentastarch is used clinically as a plasma volume expander for the management of substantial blood loss. 99mTc labelled pentastarch may be useful as a diagnostic agent in place of 99mTc labelled red blood cells. Commercial pentastarch (PS; molecular weight (MW) 240 kDa) was separated according to molecular size by using chromatography, and the fractions were pooled as small (MW 128 kDa), medium (MW 277 kDa) and large (MW 510 kDa) pentastarch. We studied the effect of various physicochemical parameters on the efficiency of radiolabelling with 99mTc and on the stability of the products, and evaluated the biological properties of the 99mTc labelled preparations. We developed an optimised kit formulation containing 3.25 mg pentastarch and 0.13 mg gentisic acid that can be reliably labelled with 99mTc at pH 6.6–8.2 with good stability. In mice, the 99mTc labelled medium pentastarch showed the more favourable blood retention properties (56% of initial blood activity is retained after 3 h) with lower liver levels.