LCLiang Cai

Liang Cai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Liang Cai has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Jiacan Su

    Department of Orthopedics Xinhua Hospital Shanghai Jiao Tong University School of Medicine Shanghai China

    2 shared publications
  • Quan Li

    Department of Orthopaedics Trauma, Changhai Hospital, Second Military Medical University, Shanghai 200433, China

    2 shared publications
  • Shicheng Wei

    Laboratory of Biomaterials and Regenerative Medicine, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871, China

    2 shared publications
  • A. R. Boccaccini

    Institute of Biomaterials, Department of Materials Science and Engineering, University of Erlangen-Nuremberg, 91058 Erlangen, Germany

    1 shared publication
  • Guo-Rong Chen

    Department of Finance, Beijing Forestry University, Beijing, China

    1 shared publication
  • Hong Li

    College of Physical Science and Technology, Sichuan University, Chengdu 610041, China

    1 shared publication

Latest Publications

  • The effects of surface bioactivity and sustained-release of genistein from a mesoporous magnesium-calcium-silicate/PK composite stimulating cell responses in vitro, and promoting osteogenesis and enhancing osseointegration in vivo

    by Liang Cai, Jue Zhang, Jun Qian, Quan Li, Hong Li, Yonggang Yan, Shicheng Wei, Jie Wei, Jiacan Su

    The surface of a mesoporous magnesium-calcium-silicate (m-MCS)/polyetheretherketone (PK) composite (MPC) was modified by sand blasting, and genistein (GS) was loaded inside the nanopores of the m-MCS on the modified MPC (MPCm) surface. The results showed that compared with MPC, the surface roughness and hydrophilcity of MPCm obviously improved with more m-MCS exposed on its surface. Moreover, no obvious differences in surface roughness and hydrophilcity were found between MPCm and GS loaded MPCm (MPCm-Ge), and both of them possessed an improved apatite mineralization ability in simulated body fluid solution (SBF) compared with MPC, indicating excellent surface bioactivity. Moreover, the MPCm obviously stimulated the adhesion, proliferation, differentiation and gene expressions of MC3T3-E1 cells compared with MPC, and the sustained-release of GS from the MPCm-Ge surface further significantly promoted the cell proliferation, differentiation and gene expression. According to the Micro-CT, histological and SEM analysis, the results demonstrated that the MPCm obviously improved osteogenesis and enhanced osseointegration in vivo compared with MPC, and the release of GS from the MPCm-Ge surface further significantly improved osteogenesis and enhanced osseointegration. In summary, the significant promotion of cell responses in vitro, and the improvements of osteogenesis and the enhancement of osseointegration in vivo were attributed to the effects of surface bioactivity and GS sustained-release from the MPCm-Ge surface. Therefore, MPCm-Ge would be a potential candidate for orthopedic and dental applications.


  • Macro-mesoporous composites containing PEEK and mesoporous diopside as bone implants: characterization, in vitro mineralization, cytocompatibility, and vascularization potential and osteogenesis in vivo

    by Liang Cai, Yongkang Pan, Songchao Tang, Quan Li, Tingting Tang, Kai Zheng, A. R. Boccaccini, Shicheng Wei, Jie Wei, Jiacan Su

    Bone implants of polyetheretherketone (PEEK) have become increasingly popular in the orthopedic field but its bioinertness and poor osteogenic properties significantly limit its applications for bone regeneration and osseointegration with host bone. In this study, by incorporation of mesoporous diopside (MD) into the PEEK matrix, macro-mesoporous PEEK/MD (PM) composites as bone implants with interconnected macropores of 300–400 μm were fabricated using the method of cold press-sintering and salt-leaching. The results showed that the compressive strength, porosity and water absorption of the porous PM composites significantly increased with an increase in the MD content. In addition, the incorporation of MD into PEEK obviously enhanced the mineralization ability of the PM composites, indicating good bioactivity. Moreover, the in vitro cell experiments indicated that the macro-mesoporous PM composites significantly promoted the adhesion and proliferation as well as osteogenic differentiation of MC3T3-E1 cells, which depended on the MD content. The results of synchrotron radiation-based micro-computed tomography (SRmCT) and histological analysis revealed that the porous PM composites possessed excellent osteogenic properties in vivo, which were obviously enhanced with an increase in the MD content. Moreover, the immunohistochemistry evaluation of type I collagen (COL I) and vascular endothelial growth factor (VEGF) confirmed that addition of MD into PEEK obviously enhanced the osteogenesis and vascularization potential of the macro-mesoporous PM composites in vivo. The results suggested that the PM composites containing macropores and mesopores as bone implants had great potential for bone repair/substitution.


  • Open Access

    Anthraquinonyl glycoside facilitates the standardization of graphene electrodes for the impedance detection of lectins

    by Bi-Wen Zhu, Liang Cai, Xiao-Peng He, Guo-Rong Chen, Yi-Tao Long

    Background: Construction of electrochemical impedance sensors by the self-assembly technique has become a promising strategy for the `label-free' detection of protein-ligand interactions. However, previous impedance sensors are devoid of an inherent electrochemical signal, which limits the standardization of the sensors for protein recognition in a reproducible manner. Results: We designed and synthesized an anthraquinonyl glycoside (AG) where the anthraquinone (AQ) moiety can bind to the surface of a graphene-based working electrode while the glycoside serving as a ligand for lectin. By measuring the inherent voltammetric signal of AQ, the glycosides decorated on the working electrode could be simply quantified to obtain electrodes with a unified signal window. Subsequently, impedance analysis showed that the `standardized' electrodes gave a reproducible electrochemical response to a selective lectin with no signal variation in the presence of unselective proteins. Conclusion: Anthraquinone-modified ligands could be used to facilitate the standardization of electrochemical impedance sensors for the reproducible, selective analysis of ligand-protein interactions.