Pavol Makys
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pavol Makys has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Alex Franko
Department of Power Systems and Electric Drives, University of Zilina, Zilina, Slovakia
2 shared publications - Jan Vittek
Faculty of Electrical Engineering, University of Žilina, Žilina, Slovakia
2 shared publications - Lukas Gorel
Department of Power Electrical Systems, Faculty of Electrical Engineering, University of Zilina, Slovakia
2 shared publications - Michal Vidlak
Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, University of Zilina, Univerzitna 1, 010 26 Zilina, Slovakia
2 shared publications - Pavol Rafajdus
Department of Power System and Electric Drives, University of Zilina, Zilina, Slovakia
2 shared publications - Andrej Blaško
Department of Power Electrical Systems, Faculty of Electrical Engineering and Information Technology, University of Žilina, Univerzitná 8215/1, 010 26 Žilina, Slovakia
1 shared publication
Latest Publications
- Open Access
Experimental Validation of a High-Frequency Full-SiC Auxiliary Converter for AC Railway Supply Systems
This paper presents the experimental validation of a high-frequency full-SiC railway auxiliary converter power module intended as a building block for modular multi-system railway auxiliary converters. The proposed architecture employs a unified SiC-based power conversion platform that integrates an active front-end single-phase PWM rectifier with a galvanically isolated high-frequency DC/DC stage operating at 90 kHz under zero-current switching (ZCS) conditions. Although the converter is designed for both AC and DC traction systems, this study focuses primarily on its operation under single-phase AC railway supply conditions, which are representative of practical applications. A hybrid bipolar–unipolar modulation strategy is used to reduce the RMS voltage stress on the input inductor while preserving controllability of the input current near the voltage zero-crossing regions. Special attention is given to operation under distorted railway supply voltages, which are common in real traction systems. The control structure combines a proportional–resonant (PR) current controller, harmonic compensators, feedforward voltage compensation, and MSOGI-based synchronization to ensure stable synchronization and low-input current distortion even under non-ideal conditions. Experimental validation was performed on a 10 kW laboratory prototype. The results demonstrate a peak efficiency of 98.4% and near-unity input power factor. Under heavily distorted supply conditions , the input current distortion remained below . Harmonic and STFT analyses confirmed the robustness of the proposed synchronization and current control structure. The obtained results indicate that the proposed high-frequency full-SiC converter topology is a promising solution for future modular railway auxiliary converters, offering high efficiency, reduced passive component volume, and high power density. Full-scale high-voltage validation under both AC and DC traction systems remains the subject of further work.Open AccessExperimental Validation of a High-Frequency Full-SiC Auxiliary Converter for AC Railway Supply Systems
This paper presents the experimental validation of a high-frequency full-SiC railway auxiliary converter power module intended as a building block for modular multi-system railway auxiliary converters. The proposed architecture employs a unified SiC-based power conversion platform that integrates an active front-end single-phase PWM rectifier with a galvanically isolated high-frequency DC/DC stage operating at 90 kHz under zero-current switching (ZCS) conditions. Although the converter is designed for both AC and DC traction systems, this study focuses primarily on its operation under single-phase AC railway supply conditions, which are representative of practical applications. A hybrid bipolar–unipolar modulation strategy is used to reduce the RMS voltage stress on the input inductor while preserving controllability of the input current near the voltage zero-crossing regions. Special attention is given to operation under distorted railway supply voltages, which are common in real traction systems. The control structure combines a proportional–resonant (PR) current controller, harmonic compensators, feedforward voltage compensation, and MSOGI-based synchronization to ensure stable synchronization and low-input current distortion even under non-ideal conditions. Experimental validation was performed on a 10 kW laboratory prototype. The results demonstrate a peak efficiency of 98.4% and near-unity input power factor. Under heavily distorted supply conditions , the input current distortion remained below . Harmonic and STFT analyses confirmed the robustness of the proposed synchronization and current control structure. The obtained results indicate that the proposed high-frequency full-SiC converter topology is a promising solution for future modular railway auxiliary converters, offering high efficiency, reduced passive component volume, and high power density. Full-scale high-voltage validation under both AC and DC traction systems remains the subject of further work. - Open Access
- 17 April 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (8) , 10725-10733
Investigation of sensorless control of permanent magnet synchronous motors using different strategies in mid- and high-speed region
The research outlines the outcomes of utilizing methods based on a mathematical model of the motor for sensorless control of permanent magnet synchronous motors (PMSM) in the medium- and high-speed range using different strategies. The Back-EMF observer utilizes stator voltages, stator currents, and a mathematical model of the motor. An estimator, like a phase-locked loop or an Atan function, is used to determine the rotor speed and position. As the accuracy of these estimates has a direct influence on the quality and dynamics of the sensorless control, precise Back-EMF signal observation is paramount. Furthermore, the research demonstrates the implementation of sensorless control in an actual motor. The results are divided into four sections, comprising steady states, transient states, states with load torque and robustness against parameter changes. In order to fully explore the theory and its real-world applications, the simulation results are compared with those obtained from measurements taken on a real motor.
- 17 April 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (8) , 10725-10733
Open AccessInvestigation of sensorless control of permanent magnet synchronous motors using different strategies in mid- and high-speed region
The research outlines the outcomes of utilizing methods based on a mathematical model of the motor for sensorless control of permanent magnet synchronous motors (PMSM) in the medium- and high-speed range using different strategies. The Back-EMF observer utilizes stator voltages, stator currents, and a mathematical model of the motor. An estimator, like a phase-locked loop or an Atan function, is used to determine the rotor speed and position. As the accuracy of these estimates has a direct influence on the quality and dynamics of the sensorless control, precise Back-EMF signal observation is paramount. Furthermore, the research demonstrates the implementation of sensorless control in an actual motor. The results are divided into four sections, comprising steady states, transient states, states with load torque and robustness against parameter changes. In order to fully explore the theory and its real-world applications, the simulation results are compared with those obtained from measurements taken on a real motor.
- Open Access
Proposal of Low-Speed Sensorless Control of IPMSM Using a Two-Interval Six-Segment High-Frequency Injection Method with DC-Link Current Sensing
This paper proposes a modification to existing saliency-based, sensorless control strategy for interior permanent magnet synchronous motors. The proposed approach leverages a two-interval, six-segment high-frequency voltage signal injection technique. It aims to improve rotor position and speed estimation accuracy when utilizing a single current sensor positioned in the inverter’s DC-bus circuit. The key innovation lies in modifying both the high-frequency signal injection and demodulation processes to address challenges in accurate phase current reconstruction and rotor position estimation, at low and zero speeds. A significant modification to the traditional high-frequency voltage signal injection method is introduced, which involves splitting the signal injection and the field-oriented control algorithm into two distinct sampling and switching periods. This approach ensures that no portion of the injected voltage space vector falls into the immeasurable region of space vector modulation, which could otherwise compromise current measurements. The dual-period structure, termed the two-interval six-segment high-frequency injection, allows for more precise current measurement during the signal injection period while maintaining optimal motor control during the field-oriented control period. Furthermore, this paper explores a different demodulation technique that improves the estimation of rotor position and speed. By employing a synchronous filter in combination with a phase-locked loop, the proposed method enhances the robustness of the system against noise and inaccuracies typically encountered in phase current reconstruction. The effectiveness of the proposed modifications is demonstrated through comprehensive simulation results. These results confirm that the enhanced method offers more reliable rotor position and speed estimates compared to the existing sensorless technique, making it particularly suitable for applications requiring high precision in motor control.
Open AccessProposal of Low-Speed Sensorless Control of IPMSM Using a Two-Interval Six-Segment High-Frequency Injection Method with DC-Link Current Sensing
This paper proposes a modification to existing saliency-based, sensorless control strategy for interior permanent magnet synchronous motors. The proposed approach leverages a two-interval, six-segment high-frequency voltage signal injection technique. It aims to improve rotor position and speed estimation accuracy when utilizing a single current sensor positioned in the inverter’s DC-bus circuit. The key innovation lies in modifying both the high-frequency signal injection and demodulation processes to address challenges in accurate phase current reconstruction and rotor position estimation, at low and zero speeds. A significant modification to the traditional high-frequency voltage signal injection method is introduced, which involves splitting the signal injection and the field-oriented control algorithm into two distinct sampling and switching periods. This approach ensures that no portion of the injected voltage space vector falls into the immeasurable region of space vector modulation, which could otherwise compromise current measurements. The dual-period structure, termed the two-interval six-segment high-frequency injection, allows for more precise current measurement during the signal injection period while maintaining optimal motor control during the field-oriented control period. Furthermore, this paper explores a different demodulation technique that improves the estimation of rotor position and speed. By employing a synchronous filter in combination with a phase-locked loop, the proposed method enhances the robustness of the system against noise and inaccuracies typically encountered in phase current reconstruction. The effectiveness of the proposed modifications is demonstrated through comprehensive simulation results. These results confirm that the enhanced method offers more reliable rotor position and speed estimates compared to the existing sensorless technique, making it particularly suitable for applications requiring high precision in motor control.
- Open Access
- 13 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (2) , 1077
Self-Sensing Six-Phase PMSM Drive Based on Back-EMF Measurement
This paper presents a novel procedure for the emergency sensorless operation of a six-phase electric drive. More degrees of freedom provided by multiphase technology have been utilized to determine the rotor flux position. The proposed technique is based on the direct measurement of the back EMF generated on a disconnected three-phase winding of a six-phase permanent-magnet synchronous machine (PMSM). The method is suitable for the emergency operation of an electric drive in the case of speed/position sensor failure. The proposed solution has been verified utilizing a six-phase permanent-magnet synchronous machine with a displacement of 30° between two three-phase sets of the stator winding and a power of 1 kW.
- 13 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (2) , 1077
Open AccessSelf-Sensing Six-Phase PMSM Drive Based on Back-EMF Measurement
This paper presents a novel procedure for the emergency sensorless operation of a six-phase electric drive. More degrees of freedom provided by multiphase technology have been utilized to determine the rotor flux position. The proposed technique is based on the direct measurement of the back EMF generated on a disconnected three-phase winding of a six-phase permanent-magnet synchronous machine (PMSM). The method is suitable for the emergency operation of an electric drive in the case of speed/position sensor failure. The proposed solution has been verified utilizing a six-phase permanent-magnet synchronous machine with a displacement of 30° between two three-phase sets of the stator winding and a power of 1 kW.
- Open Access
- 13 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 9179
A Novel Constant Power Factor Loop for Stable V/f Control of PMSM in Comparison against Sensorless FOC with Luenberger-Type Back-EMF Observer Verified by Experiments
This paper proposes a novel constant power factor loop in the V/f control strategy with stabilization for a permanent magnet synchronous motor (PMSM). The advantage of such an algorithm is the independence of the machine parameters, which vary under different operational conditions, e.g., with temperature, magnetic core saturation, and skin-effect. Furthermore, it is a low-cost and simple-to-implement sensorless solution. The proposed strategy is compared against traditional sensorless FOC with a Luenberger-type back-electromotive force (EMF) observer, which can be designed based on the machine model. The output of this kind of observer is typically an error signal, which can be specified for position deviation, requiring phase-locked loop (PLL) algorithm implementation. Employing PLL, a rotor speed and position can be estimated from such an error. Therefore, it is a complex sensorless technique with high-performance microcontroller unit (MCU) requirements. Both strategies are deeply analyzed, mathematically described, and compared within the paper. At the end of the paper, these sensorless strategies are supported by experimental verification with a traction PMSM designed for golf cart applications, and the pros and cons of both techniques are discussed.
- 13 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 9179
Open AccessA Novel Constant Power Factor Loop for Stable V/f Control of PMSM in Comparison against Sensorless FOC with Luenberger-Type Back-EMF Observer Verified by Experiments
This paper proposes a novel constant power factor loop in the V/f control strategy with stabilization for a permanent magnet synchronous motor (PMSM). The advantage of such an algorithm is the independence of the machine parameters, which vary under different operational conditions, e.g., with temperature, magnetic core saturation, and skin-effect. Furthermore, it is a low-cost and simple-to-implement sensorless solution. The proposed strategy is compared against traditional sensorless FOC with a Luenberger-type back-electromotive force (EMF) observer, which can be designed based on the machine model. The output of this kind of observer is typically an error signal, which can be specified for position deviation, requiring phase-locked loop (PLL) algorithm implementation. Employing PLL, a rotor speed and position can be estimated from such an error. Therefore, it is a complex sensorless technique with high-performance microcontroller unit (MCU) requirements. Both strategies are deeply analyzed, mathematically described, and compared within the paper. At the end of the paper, these sensorless strategies are supported by experimental verification with a traction PMSM designed for golf cart applications, and the pros and cons of both techniques are discussed.
- Open Access
Sensorless Speed Control of Brushed DC Motor Based at New Current Ripple Component Signal Processing
Signal processing of the brushed DC motor current was developed in this paper to obtain information about a rotor speed from a measured motor current. The brushed DC motor current contains a signal with a frequency proportional to the rotor speed. This signal is the outcome of a commutation process occurring in the brushed DC motor, and it is called a ripple component. Since the number of ripples in the measured motor current per one rotation is constant, the rotor speed can be estimated. A discrete bandpass filter with a floating bandwidth was developed as the main part of signal processing. This new interpretation of the bandpass filter was used to extract a frequency of the ripple component from the measured motor current. This frequency was used to acquire information about the estimated rotor speed. The estimated speed was set as a feedback value to a cascade control structure to provide sensorless speed control. The advantages and limitations of this approach are presented in this paper. Based on simulations and experimental results, it was confirmed that the proposed sensorless speed control is robust, accurate, and works precisely in a wide range of speeds.
Open AccessSensorless Speed Control of Brushed DC Motor Based at New Current Ripple Component Signal Processing
Signal processing of the brushed DC motor current was developed in this paper to obtain information about a rotor speed from a measured motor current. The brushed DC motor current contains a signal with a frequency proportional to the rotor speed. This signal is the outcome of a commutation process occurring in the brushed DC motor, and it is called a ripple component. Since the number of ripples in the measured motor current per one rotation is constant, the rotor speed can be estimated. A discrete bandpass filter with a floating bandwidth was developed as the main part of signal processing. This new interpretation of the bandpass filter was used to extract a frequency of the ripple component from the measured motor current. This frequency was used to acquire information about the estimated rotor speed. The estimated speed was set as a feedback value to a cascade control structure to provide sensorless speed control. The advantages and limitations of this approach are presented in this paper. Based on simulations and experimental results, it was confirmed that the proposed sensorless speed control is robust, accurate, and works precisely in a wide range of speeds.
- Open Access
- 20 May 2020
- Published by IntechOpen
Analysis of Electrical Machines
The aim of this book is to present methods needed for the analysis of electrical machine performances in transients and steady-state conditions by means of simulations in MATLAB-Simulink and by means of FEM. The parameter determination based on the design procedure is presented, and some examples are given. The authors used outputs of their long-time experiences in research and scientists work as university professors and use their pedagogical skills to create a guide on how to investigate parameters of equivalent circuits and apply them for investigation of transients and steady-state conditions.
- 20 May 2020
- Published by IntechOpen
Open AccessAnalysis of Electrical Machines
The aim of this book is to present methods needed for the analysis of electrical machine performances in transients and steady-state conditions by means of simulations in MATLAB-Simulink and by means of FEM. The parameter determination based on the design procedure is presented, and some examples are given. The authors used outputs of their long-time experiences in research and scientists work as university professors and use their pedagogical skills to create a guide on how to investigate parameters of equivalent circuits and apply them for investigation of transients and steady-state conditions.
- Open Access
Effect of Saturation on Field Oriented Control of the New Designed Reluctance Synchronous Motor
In this paper the effect of saturation on torque production of a reluctance synchronous motor (RSM), which was originally built as an induction motor (IM), is investigated. The rotor was replaced with new one, designed as synchronous reluctance cageless rotor with barriers, the shape and number of which were optimized to maximize the reluctance ratio. The torque measurement was done while the RSM was fed by frequency converter controlled by a microcontroller with closed loop field oriented control strategy to find out how saturation effects the developed torque at various values of the currents and speeds. It is shown how the load angle at which the maximum torque was achieved is changed. It was found out that the load angle was shifted to higher values depending on the speed of operation.
Open AccessEffect of Saturation on Field Oriented Control of the New Designed Reluctance Synchronous Motor
In this paper the effect of saturation on torque production of a reluctance synchronous motor (RSM), which was originally built as an induction motor (IM), is investigated. The rotor was replaced with new one, designed as synchronous reluctance cageless rotor with barriers, the shape and number of which were optimized to maximize the reluctance ratio. The torque measurement was done while the RSM was fed by frequency converter controlled by a microcontroller with closed loop field oriented control strategy to find out how saturation effects the developed torque at various values of the currents and speeds. It is shown how the load angle at which the maximum torque was achieved is changed. It was found out that the load angle was shifted to higher values depending on the speed of operation.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Experimental study of ball on plate platform
This paper is extension of article SIMULATION AND EXPERIMENTAL STUDY OF BALL POSITION CONTROL AT BIAXIAL PLATFORM USING STATE SPACE APPROACH, which came out in number 1/2018 of journal Komunikácie (Communications). This extension is focused on other control techniques, which have wider bandwidth. This paper presents design of state space observer with state space feedback, which is extended by compensator to achieve better dynamic properties of control structure. Another presented control technique is sliding mode control, which is more robust and has also wider bandwidth. Control structures are designed for stabilization of the ball's position on a plate and for capability of trajectory tracking. All techniques are designed, practically verified and compared. Pole placement method was used for calculating of the parameters of the proposed control structures.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Experimental study of ball on plate platform
This paper is extension of article SIMULATION AND EXPERIMENTAL STUDY OF BALL POSITION CONTROL AT BIAXIAL PLATFORM USING STATE SPACE APPROACH, which came out in number 1/2018 of journal Komunikácie (Communications). This extension is focused on other control techniques, which have wider bandwidth. This paper presents design of state space observer with state space feedback, which is extended by compensator to achieve better dynamic properties of control structure. Another presented control technique is sliding mode control, which is more robust and has also wider bandwidth. Control structures are designed for stabilization of the ball's position on a plate and for capability of trajectory tracking. All techniques are designed, practically verified and compared. Pole placement method was used for calculating of the parameters of the proposed control structures.
- 27 July 2017
- Published by Springer Nature in Electrical Engineering
- Vol. 99 (4) , 1325-1335
Improved barriers rotor of the reluctance synchronous motor
- 27 July 2017
- Published by Springer Nature in Electrical Engineering
- Vol. 99 (4) , 1325-1335
Improved barriers rotor of the reluctance synchronous motor