Zhilin Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhilin Guo has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Guang Wang
Nanjing NR Electric Company Ltd., Nanjing, China
1 shared publication - Hong Cao
State Key Laboratory for Power Grid Safety and Energy Conservation (China Electric Power Research Institute), Beijing 100192, China
1 shared publication Junyong Wu
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044 China
1 shared publication- Junyong Wu
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
1 shared publication Liangliang Hao
School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044 China
1 shared publication- Liangliang Hao
Beijing Jiaotong University
1 shared publication
Latest Publications
- Open Access
Synchronous Condenser’s Loss of Excitation and Its Impact on the Performance of UHVDC
The synchronous condenser (SC) has a broad application prospect in ultra-high-voltage direct current (UHVDC) systems. The SC’s loss of excitation (LOE) is an important grid-related fault that may cause damage to the UHVDC. However, as the premise of the scientific protection configuration, knowledge of the SC’s LOE feature and its impact on UHVDC is still missing. This article first analyzes the SC’s LOE feature, offering a basic cognition of this fault. Secondly, the LOE SC’s reactive power response to system voltage variation is studied in the single-machine infinite-bus system. This lends a foundation for transient UHVDC research. Finally, the LOE SC’s impacts on steady and transient UHVDC are evaluated, respectively, considering different AC strengths and system faults through PSCAD/EMTDC (V4.6, Manitoba HVDC Research Center, Winnipeg, MB, Canada) simulations. The results show that: (1) LOE the SC absorbs reactive power while maintaining synchronous operation, its excitation current declines monotonically; (2) the LOE SC has an insignificant effect on steady-state UHVDC; (3) the LOE SC can restrain the overvoltage and benefit the rectifier’s transient stability; and (4) to reduce the inverter’s commutation failure, keeping LOE SC is more effective than separating it beforehand, while separating the LOE SC after the system voltage drop performs best. These conclusions could provide insights for the protection’s criterion and operation mode selections.
Open AccessSynchronous Condenser’s Loss of Excitation and Its Impact on the Performance of UHVDC
The synchronous condenser (SC) has a broad application prospect in ultra-high-voltage direct current (UHVDC) systems. The SC’s loss of excitation (LOE) is an important grid-related fault that may cause damage to the UHVDC. However, as the premise of the scientific protection configuration, knowledge of the SC’s LOE feature and its impact on UHVDC is still missing. This article first analyzes the SC’s LOE feature, offering a basic cognition of this fault. Secondly, the LOE SC’s reactive power response to system voltage variation is studied in the single-machine infinite-bus system. This lends a foundation for transient UHVDC research. Finally, the LOE SC’s impacts on steady and transient UHVDC are evaluated, respectively, considering different AC strengths and system faults through PSCAD/EMTDC (V4.6, Manitoba HVDC Research Center, Winnipeg, MB, Canada) simulations. The results show that: (1) LOE the SC absorbs reactive power while maintaining synchronous operation, its excitation current declines monotonically; (2) the LOE SC has an insignificant effect on steady-state UHVDC; (3) the LOE SC can restrain the overvoltage and benefit the rectifier’s transient stability; and (4) to reduce the inverter’s commutation failure, keeping LOE SC is more effective than separating it beforehand, while separating the LOE SC after the system voltage drop performs best. These conclusions could provide insights for the protection’s criterion and operation mode selections.
- Open Access
- 1 October 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 342 (1) , 012007
Application of the New Generation Large Capacity Synchronous Condenser in HVDC System
The AC dynamic reactive power compensation in high voltage direct current (HVDC) still remains an unsolved problem. Owing to its flexible and rapid reactive power output, synchronous condenser (SC) has a broad application prospect on sending and receiving ends of HVDC transmission system. Firstly, the system structure of a new large capacity SC is introduced. Secondly, reactive power dynamic characteristics of SC in sub-transient and transient are studied theoretically. Then its supporting effect on low bus voltage is analyzed and verified. On this basis, the reactive power application requirements of SC in DC system are studied. An actual transmission system model is established by PSCAD/EMTDC. The simulation verifies the suppression effect of SC on commutation failure and bus transient overvoltage, which provides a theoretical basis for the application of SC in HVDC system.
- 1 October 2019
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 342 (1) , 012007
Open AccessApplication of the New Generation Large Capacity Synchronous Condenser in HVDC System
The AC dynamic reactive power compensation in high voltage direct current (HVDC) still remains an unsolved problem. Owing to its flexible and rapid reactive power output, synchronous condenser (SC) has a broad application prospect on sending and receiving ends of HVDC transmission system. Firstly, the system structure of a new large capacity SC is introduced. Secondly, reactive power dynamic characteristics of SC in sub-transient and transient are studied theoretically. Then its supporting effect on low bus voltage is analyzed and verified. On this basis, the reactive power application requirements of SC in DC system are studied. An actual transmission system model is established by PSCAD/EMTDC. The simulation verifies the suppression effect of SC on commutation failure and bus transient overvoltage, which provides a theoretical basis for the application of SC in HVDC system.