NLN. Leitgeb

N. Leitgeb

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


N. Leitgeb has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • J. Schrottner

    Institute of Clinical Engineering and European Notified Body of Medical Devices, Graz University of Technology , Inffeldgasse 18, A-8010 Graz , Austria

    2 shared publications
  • R. Cech

    Institute of Clinical Engineering and European Notified Body of Medical Devices, Graz University of Technology , Inffeldgasse 18, A-8010 Graz , Austria

    2 shared publications
  • M. Rampetsreiter

    Institute of Clinical Engineering and European Notified Body of Medical Devices, Graz University of Technology , Inffeldgasse 18, A-8010 Graz , Austria

    1 shared publication
  • P. Lehofer

    Institute of Clinical Engineering and European Notified Body of Medical Devices, Graz University of Technology , Inffeldgasse 18, A-8010 Graz , Austria

    1 shared publication
  • U. Schmidpeter

    Institute of Clinical Engineering and European Notified Body of Medical Devices, Graz University of Technology , Inffeldgasse 18, A-8010 Graz , Austria

    1 shared publication

Latest Publications

  • Magnetic emission ranking of electrical appliances. A comprehensive market survey

    by N. Leitgeb, R. Cech, J. Schrottner, P. Lehofer, U. Schmidpeter, M. Rampetsreiter

    Over the last decades emissions of magnetic fields from electric appliances have considerably changed. Based on a comprehensive market survey it could be shown that today magnetic emissions are usually characterised by complex frequency spectra while single-frequency emissions have become rare. Therefore, spectral assessment procedures play a critical role. Compared to frequency-weighted equivalent magnetic induction, rms values may underestimate emissions up to two orders of magnitudes. Therefore, rms measurements are not suitable and emission-ranking lists of devices need revision. Surface hot-spot measurements at nominal load conditions and 230 V/50 Hz supply involved 1146 new electrical devices of 166 different categories. High emissions were not rare. Magnetic emissions of devices of 73 different categories exceeded reference levels up to almost two orders of magnitudes above reference levels. Maximum values were higher than reported so far. Magnetic emissions were high enough to make even conformity with existing basic restrictions not self-evident.


  • Electric emissions from electrical appliances

    by N. Leitgeb, R. Cech, J. Schrottner

    Electric emissions from electric appliances are frequently considered negligible, and standards consider electric appliances to comply without testing. By investigating 122 household devices of 63 different categories, it could be shown that emitted electric field levels do not justify general disregard. Electric reference values can be exceeded up to 11-fold. By numerical dosimetry with homogeneous human models, induced intracorporal electric current densities were determined and factors calculated to elevate reference levels to accounting for reduced induction efficiency of inhomogeneous fields. These factors were found not high enough to allow generally concluding on compliance with basic restrictions without testing. Electric appliances usually simultaneously emit both electric and magnetic fields exposing almost the same body region. Since the sum of induced current densities is limited, one field component reduces the available margin for the other. Therefore, superposition of electric current densities induced by either field would merit consideration.