FBFelix Bulatbayev

Felix Bulatbayev

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Felix Bulatbayev has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Effect of the Technical Condition of 110 kV SF6 Gas Circuit Breakers on the Reliability of Power Systems, Taking into Account the Assessment of the Remaining Resource

    by Felix Bulatbayev, Alina Marenova, Yuliya Bulatbayeva, Olzhas Mahambetov, Elena Neshina

    The method presented by theoretical calculations for estimating the residual resource of possible on and off switches by high-voltage circuit breakers is proposed based on the switching resource utilization factor and an integral indicator of the technical condition of gas-free circuit breakers. The calculations were performed in relation to the passport data by the manufacturer. They show the relationship between the deterioration of the technical condition of the equipment with an increase in the probability of failures and a decrease in the reliability of the protective function of power systems. The results obtained can be used in making operational decisions and planning maintenance of high-voltage circuit breakers with an insulating environment – gas. The results of calculations of dependent indicators are illustrated in the form of graphs. The calculations performed demonstrate the influence of key diagnostic parameters on the remaining life of electrical equipment.

  • Analysis and Modeling of Modern Forecasting Methods for Power Generation in Hybrid Wind–Solar Systems

    by Felix Nazymovich Bulatbayev, Makhabbat Kudaibergenovna Tleugabylova

    This paper provides a theoretical analysis of modern forecasting methodologies for power generation in hybrid wind–solar systems. It discusses statistical, physical, and machine learning approaches, with emphasis on hybrid architectures integrating numerical weather prediction (NWP) data with deep learning models. Evaluation metrics and methodological frameworks are analyzed, highlighting their applicability to hybrid energy forecasting.

  • Open Access

    Development of a method for energy-efficient control of parallel pump units using the covariance matrix adaptation evolution strategy

    by Yuliya Bulatbayeva, Rauan Kossymbayev, Victoria Tsypkina, Vera Ivanova, Felix Bulatbayev

    The object of the study is a pumping station with four parallel-connected centrifugal pump units driven by asynchronous electric motors. The problem to be solved is that modern stations, partially equipped with variable frequency drive (VFDs), allow only maintaining the head without observing allowable modes, failing to ensure reliability and energy efficiency. This leads to rapid wear and efficiency reduction. The solution lies in optimizing energy consumption and keeping operating points within the POR (preferred operating region), to prevent accelerated wear. The essence of the results obtained lies in the development of a method for energy-efficient control based on the CMA-ES strategy integrated with a model in MATLAB (California, USA). Experiments showed that the balanced strategy reduces energy consumption by 7% while maintaining equipment in the POR zone for 95.8% of the time. Comparative analysis showed that a configuration with two VFDs is a rational compromise, limiting energy overconsumption to 25% relative to systems fully equipped with VFDs. These results allowed to solve the specified problem due to the introduction of a block performing an analytical express assessment of the required number of units based on affinity laws, using adaptive penalty functions and CMA-ES tuning. This allowed excluding combinatorial enumeration and reducing the search time for the optimal solution to 60–80 seconds, ensuring speed unavailable to standard genetic algorithms. The conditions under which they can be used on practice involve the application of the developed method as a supervisory control (SCADA) for water supply pumping stations to generate control setpoints with a periodicity of 1–2 minutes without the need for complete equipment replacement.

  • Enhancing the Energy Efficiency of Parallel-operated Pump Units Via a Genetic Algorithm

    by Rauan Kosymbayev, Yulia Bulatbayeva, Victoria Tsypkina, Vera Ivanova, Felix Bulatbayev

    The article examines the application of a genetic algorithm to improve the energy efficiency and reliability of pump units operating in parallel. Modeling was carried out in the Matlab&Simulink environment, enabling a detailed analysis of the dynamics of parallel operation of centrifugal pumps. The control inputs were the frequencies of four drives, and the criteria were maintaining the required pressure while minimizing total power and observing hydraulic constraints. A series of computational experiments demonstrated how operator settings and objective-function weights affect convergence speed and solution quality. The results show a stable reduction in energy consumption while preserving operating reliability. Based on the analysis, practical recommendations are proposed for selecting genetic-algorithm parameters for pump-system optimization tasks.

  • Open Access

    Nonlinear Quasi-Classical Model of Isothermal Relaxation Polarization Currents in Functional Elements of Microelectronics, Optoelectronics, and Fiber Optics Based on Crystals with Ionic-Molecular Chemical Bonds with Complex Crystalline Structure

    by Valeriy Kalytka, Ali Mekhtiyev, Yelena Neshina, Aleksey Yurchenko, Aliya Alkina, Felix Bulatbayev, Valeriy Issayev, Kanat Makhanov, Dmitriy Lukin, Damir Kayumov, et al.

    In this article, the mechanism of relaxation polarization currents occurring at a constant temperature (isothermal process) in crystals with ionic-molecular chemical bonds (CIMBs) in an alternating electric field was investigated. Methods of the quasi-classical kinetic theory of dielectric relaxation, based on solutions of the nonlinear system of Fokker–Planck and Poisson equations (for the blocking electrode model) and perturbation theory (by expanding into an infinite series in powers of a dimensionless small parameter) were used. Generalized nonlinear mathematical expressions for calculating the complex amplitudes of relaxation modes of the volume-charge distribution of the main charge carriers (ions, protons, water molecules, etc.) were obtained. On this basis, formulas for the current density of relaxation polarization (for transient processes in a dielectric) in the k-th approximation of perturbation theory were constructed. The isothermal polarization currents are investigated in detail in the first four approximations (k = 1, 2, 3, 4) of perturbation theory. These expressions will be applied in the future to compare the results of theory and experiment, in analytical studies of the kinetics of isothermal ion-relaxation (in crystals with hydrogen bonds (HBC), proton-relaxation) polarization and in calculating the parameters of relaxers (molecular characteristics of charge carriers and crystal lattice parameters) in a wide range of field parameters (0.1–1000 MV/m) and temperatures (1–1550 K). Asymptotic (far from transient processes) recurrent formulas are constructed for complex amplitudes of relaxation modes and for the polarization current density in an arbitrary approximation k of perturbation theory with a multiplicity r by the polarizing field (a multiple of the fundamental frequency of the field). The high degree of reliability of the theoretical results obtained is justified by the complete agreement of the equations of the mathematical model for transient and stationary processes in the system with a harmonic external disturbance. This work is of a theoretical nature and is focused on the construction and analysis of nonlinear properties of a physical and mathematical model of isothermal ion-relaxation polarization in CIMB crystals under various parameters of electrical and temperature effects. The theoretical foundations for research (construction of equations and working formulas, algorithms, and computer programs for numerical calculations) of nonlinear kinetic phenomena during thermally stimulated relaxation polarization have been laid. This allows, with a higher degree of resolution of measuring instruments, to reveal the physical mechanisms of dielectric relaxation and conductivity and to calculate the parameters of a wide class of relaxators in dielectrics in a wide experimental temperature range (25–550 K).


  • Open Access

    Development of a method for reliability assessment of distribution power networks up to 110 kV

    by Fariza Abilzhanova, Felix Bulatbaev, Aizada Kuanyshtaeva

    The study focuses on the reliability assessment of distribution power networks operating at voltages up to 110 kV, addressing the challenges of increasing loads, aging infrastructure, and the integration of renewable energy sources. A novel method and model for reliability assessment are proposed, incorporating failure rates, recovery times, and topological characteristics of networks. The research identifies critical factors influencing network reliability, including the level of redundancy, operational conditions, and climatic impacts. Notable findings show that network points with multiple feeder connections demonstrate the highest reliability, exceeding 99.99 %, while those with single-transformer configurations are the most vulnerable to failures. The average failure rate for overhead lines is calculated at 1.29 failures per 100 km annually, with recovery times reaching up to 40 hours for critical nodes. The results are explained by the interplay of structural and operational factors, where redundancy significantly enhances reliability, and outdated equipment increases vulnerability. The study’s distinguishing feature lies in its use of Markov processes to dynamically model failures and recoveries, offering a comprehensive framework compared to traditional static methods. The practical applications of the results include improving network design through enhanced redundancy, optimizing maintenance strategies for critical elements, and supporting the integration of Smart Grid technologies. These findings contribute to the development of more resilient and efficient power distribution networks, adaptable to modern operational demands


  • Automated System for Diagnosing Structural Elements of Overhead Power Lines

    by Vyacheslav Yugay, Felix Bulatbayev, Karshiga Smagulova, Sofiya Voytkevich, Leonid Daich, Evgeniy Kotov

    The work is devoted to the development of a system for diagnosing the technical condition of structural elements of overhead high-voltage power lines (HVPL). Methods for research and development of structural diagrams of systems for collecting and primary processing of information are based on a combination of experimental and descriptive methods, which will ensure the achievement of goals and scientific objectives. This paper defines the main directions of research and development for monitoring overhead power lines, develops methods for monitoring volumetric and surface leakage currents of high-voltage insulators, and presents the structure of the hardware of electrical energy converters for powering electronic units structurally located in the upper part of the overhead power line support. The materials of the work will form the basis for the construction, structure and technical solutions for a complex of remote monitoring of the condition of overhead transmission line structural elements.

  • АНАЛИЗ ЭНЕРГОПОТРЕБЛЕНИЯ ПРИ НЕПРЕРЫВНЫМ И ДИСКРЕТНЫМ РЕГУЛИРОВАНИЕМ ПОДАЧИ НА НАСОСНОЙ СТАНЦИИ ПЕРВОГО ПОДЪЕМА

    by Р. Б. Косымбаев, Ю. Ф. Булатбаева, Ф.н. Булатбаев

    Статья посвящена результатам исследования методов регулирования насосных станций первого подъема. Эти насосные станции чаще всего подают воду в аккумулирующие емкости, что отличает их от насосных станций следующих подъемов. По причине отсутствия видимой необходимости в регулировании подачи на таких станциях обычно применяется дискретный метод регулирования, который заключается в запуске насосов при достижении минимального уровня воды в аккумулирующей емкости и последующем отключении при достижении верхнего уровня, тем самым поддерживая уровень в резервуаре. При наполнении резервуара уровень в резервуаре суммируется с статическим напором, который зависит от геодезической высоты между уровнем водоема, который также склонен к изменениям и дном емкости. Эти колебания статического напора приводят к лишнему расходу электроэнергии. В целях сокращения расхода электроэнергии необходимо обеспечить равенство между подачей и водопотреблением, что возможно при применении метода непрерывного регулирования. В процессе исследования сделан вывод о том, что при непрерывном методе регулирования подача насоса стремится к равенству с водопотреблением. В результате этого потребляемая мощность равняется необходимой на данный момент мощности, что приводит к стабилизации статического напора и соответственно уровня воды в емкости. Данная стабилизация приводит к значительному снижению энергозатрат. Ключевые слова: преобразователь частоты, насосная станция, энергоэффективность, электродвигатель, Simulink.

  • Open Access

    Theoretical Studies of Nonlinear Relaxation Electrophysical Phenomena in Dielectrics with Ionic–Molecular Chemical Bonds in a Wide Range of Fields and Temperatures

    by Valeriy Kalytka, Felix Bulatbayev, Yelena Neshina, Yekaterina Bilichenko, Arkadiy Bilichenko, Aleksandr Bashirov, Yelena Sidorina, Yelena Naboko, Nurbol Malikov, Yelena Senina

    This paper is devoted to the development of generalized (for a wide range of fields (100 kV/m–1000 MV/m) and temperatures (0–1500 K) in the radio frequency range (1 kHz–500 MHz)) methods for the theoretical investigation of the physical mechanism of nonlinear kinetic phenomena during the establishment of the relaxation polarization, due to the diffusion motion of the main charge carriers in dielectrics with ionic–molecular chemical bonds (hydrogen-bonded crystals (HBC), including layered silicates, crystalline hydrates and corundum–zirconium ceramics (CZC), etc.) in an electric field. The influence of the nonlinearities equations of the initial phenomenological model of dielectric relaxation (in HBC-proton relaxation) on the mechanism for the formation of volume–charge polarization in solid dielectrics is analyzed. The solutions for the nonlinear kinetic Fokker–Planck equation, together with the Poisson equation, for the model of blocked electrodes are built in an infinite approximation (including all orders k of smallness without dimensional parameters) of perturbation theory for an arbitrary order r of the frequency harmonic of an alternating external polarizing field. It has been established that the polarization nonlinearities in ion-molecular dielectrics, already detected at the fundamental frequency, are interpreted in the mathematical model (for the first time in this work) as interactions of the relaxation modes of the volume charge density calculated on different orders of spatial Fourier harmonics. At the fundamental frequency of the field, an analytical generalized expression is written for complex dielectric permittivity (CDP), which is expressed analytically in terms of special relaxation parameters, which are quite complex real functions in the fields of frequency and temperature. The theoretical CDP and the dielectric loss tangent spectra studied depend on the nature of the relaxation processes in the selected temperature range (Maxwell and diffusion relaxation; thermally activated and tunneling relaxation), which is relevant from the point of view of choosing exact calculation formulas when analyzing the optimal operating modes of functional elements (based on dielectrics and their composites) for circuits of instrumentation, radio engineering and power equipment in real industrial production.