Alberto De La Iglesia
Research Subjects
Alberto De La Iglesia has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Aguilera
Hospital Clínico Universitario de Santiago de Compostela, Santiago de Compostela, Spain
2 shared publications - Federico García
Instituto de Investigación Biosanitaria de Granada (ibs.GRANADA), 18012 Granada, Spain
2 shared publications - Adolfo de Salazar
Servicio de Microbiología, Hospital Universitario San Cecilio, Granada, Spain
1 shared publication Ana Belén Pérez
Clinical Microbiology Unit, University Hospital Reina Sofía. Instituto Maimónides de Investigación Biomédica de Córdoba (IMIBIC), Córdoba, Spain
1 shared publication- Ana Fuentes
Servicio de Microbiología, Hospital Universitario Clínico San Cecilio, 18016 Granada, Spain
1 shared publication Ana María Martínez-Sapiña
Clinical Microbiology Unit, Hospital Miguel Servet, Zaragoza, Spain
1 shared publication
Latest Publications
- Open Access
- 1 February 2024
- Published by MDPI AG in Preprints.org
Assessment of Performance and Comparison of Three Commercial HDV RNA Detection Assays: Implications for Diagnosis and Treatment Monitoring
Precise HDV-RNA detection and quantification are pivotal for accurate diagnosis and monitoring of response to newly approved treatment. We evaluate the performance of three assays: Hepatitis Delta RT-PCR system, EurobioPlex HDV assay, and the RoboGene HDV RNA Quantification kit 2.0, testing 151 HBsAg-positive samples, 90 HDV-RNA negative and 61 HDV-RNA positive. We also evaluated serial dilutions of the WHO international standard for HDV, PEI 7657/12. Finally, all HDV-RNA positive samples were genotyped using a next-generation sequencing strategy. Qualitative results indicated a 100% concordance between tests. Quantitative results correlated well between tests, r2=0.703 (Vircell-vs-Eurobio), r2=0.833 (Vircell-vs-RoboGene), r2=0.835 (Robogene-vs-Eurobio). Bias index was 2.083 (Vircell-vs-Eurobio), -1.283 (Vircell-vs-RoboGene), and -3.36 (Robogene-vs-Eurobio). Using the WHO IS, Vircell overestimated the viral load by 0.98 log IU/mL, Eurobio by 1.46 log IU/mL, and RoboGene underestimated it by 0.98 log IU/mL. Fifty-nine samples were successfully genotyped (Genotype 1, n=52; Genotype 5, n=7; Genotype 6, n=1), with similar results in terms of correlation and bias. The three assays demonstrate promising performance. Their accuracy, reflected in concordance rates and quantitative analysis, makes them suitable for clinical practice. However, in the absence of assay harmonization, quantitative HDV RNA monitoring should be performed in the same laboratory and assay to avoid variability.
- 1 February 2024
- Published by MDPI AG in Preprints.org
Open AccessAssessment of Performance and Comparison of Three Commercial HDV RNA Detection Assays: Implications for Diagnosis and Treatment Monitoring
Precise HDV-RNA detection and quantification are pivotal for accurate diagnosis and monitoring of response to newly approved treatment. We evaluate the performance of three assays: Hepatitis Delta RT-PCR system, EurobioPlex HDV assay, and the RoboGene HDV RNA Quantification kit 2.0, testing 151 HBsAg-positive samples, 90 HDV-RNA negative and 61 HDV-RNA positive. We also evaluated serial dilutions of the WHO international standard for HDV, PEI 7657/12. Finally, all HDV-RNA positive samples were genotyped using a next-generation sequencing strategy. Qualitative results indicated a 100% concordance between tests. Quantitative results correlated well between tests, r2=0.703 (Vircell-vs-Eurobio), r2=0.833 (Vircell-vs-RoboGene), r2=0.835 (Robogene-vs-Eurobio). Bias index was 2.083 (Vircell-vs-Eurobio), -1.283 (Vircell-vs-RoboGene), and -3.36 (Robogene-vs-Eurobio). Using the WHO IS, Vircell overestimated the viral load by 0.98 log IU/mL, Eurobio by 1.46 log IU/mL, and RoboGene underestimated it by 0.98 log IU/mL. Fifty-nine samples were successfully genotyped (Genotype 1, n=52; Genotype 5, n=7; Genotype 6, n=1), with similar results in terms of correlation and bias. The three assays demonstrate promising performance. Their accuracy, reflected in concordance rates and quantitative analysis, makes them suitable for clinical practice. However, in the absence of assay harmonization, quantitative HDV RNA monitoring should be performed in the same laboratory and assay to avoid variability.
- 1 November 2019
- Published by Elsevier in Journal of Hepatology
- Vol. 71 (5) , 876-888
High efficacy of resistance-guided retreatment of HCV patients failing NS5A inhibitors in the real world
- 1 November 2019
- Published by Elsevier in Journal of Hepatology
- Vol. 71 (5) , 876-888
High efficacy of resistance-guided retreatment of HCV patients failing NS5A inhibitors in the real world