Esben Schjødt Worm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Esben Schjødt Worm has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Morten Høyer
Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
5 shared publications - Per Rugaard Poulsen
Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
4 shared publications Anders T. Hansen
Department of Medical Physics, Aarhus University Hospital, Denmark
3 shared publicationsBritta Weber
Aarhus University Hospital
2 shared publicationsLars P. Larsen
Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
2 shared publicationsRune Hansen
Aarhus University Hospital
2 shared publications
Latest Publications
- 12 October 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (20) , 205009
Uniform versus non-uniform dose prescription for proton stereotactic body radiotherapy of liver tumors investigated by extensive motion-including treatment simulations
Compared to x-ray-based stereotactic body radiotherapy (SBRT) of liver cancer, proton SBRT may reduce the normal liver tissue dose. For an optimal trade-off between target and liver dose, a non-uniform dose prescription is often applied in x-ray SBRT, but lacks investigation for proton SBRT. Also, proton SBRT is prone to breathing-induced motion-uncertainties causing target mishit or dose alterations by interplay with the proton delivery. This study investigated non-uniform and uniform dose prescription in proton-based liver SBRT, including effects of rigid target motion observed during planning-4DCT and treatment. The study was based on 42 x-ray SBRT fractions delivered to 14 patients under electromagnetic motion-monitoring. For each patient, a non-uniform and uniform proton plan were made. The uniform plan was renormalized to be iso-toxic with the non-uniform plan using a NTCP model for radiation-induced liver disease. The motion data were used in treatment simulations to estimate the delivered target dose with rigid motion. Treatment simulations were performed with and without a repainting scheme designed to mitigate interplay effects. Including rigid motion, the achieved CTV mean dose after three fractions delivered without repainting was on average (±SD) 24.8 ± 8.4% higher and the D 98% was 16.2 ± 11.3% higher for non-uniform plans than for uniform plans. The interplay-induced increase in D 2% relative to the static plans was reduced from 3.2 ± 4.1% without repainting to −0.5 ± 1.7% with repainting for non-uniform plans and from 1.5 ± 2.0% to 0.1 ± 1.3% for uniform plans. Considerable differences were observed between estimated CTV doses based on 4DCT motion and intra-treatment motion. In conclusion, non-uniform dose prescription in proton SBRT may provide considerably higher tumor doses than uniform prescription for the same complication risk. Due to motion variability, target doses estimated from 4DCT motion may not accurately reflect the delivered dose. Future studies including modelling of deformations and associated range uncertainties are warranted to confirm the findings.
- 12 October 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (20) , 205009
Uniform versus non-uniform dose prescription for proton stereotactic body radiotherapy of liver tumors investigated by extensive motion-including treatment simulations
Compared to x-ray-based stereotactic body radiotherapy (SBRT) of liver cancer, proton SBRT may reduce the normal liver tissue dose. For an optimal trade-off between target and liver dose, a non-uniform dose prescription is often applied in x-ray SBRT, but lacks investigation for proton SBRT. Also, proton SBRT is prone to breathing-induced motion-uncertainties causing target mishit or dose alterations by interplay with the proton delivery. This study investigated non-uniform and uniform dose prescription in proton-based liver SBRT, including effects of rigid target motion observed during planning-4DCT and treatment. The study was based on 42 x-ray SBRT fractions delivered to 14 patients under electromagnetic motion-monitoring. For each patient, a non-uniform and uniform proton plan were made. The uniform plan was renormalized to be iso-toxic with the non-uniform plan using a NTCP model for radiation-induced liver disease. The motion data were used in treatment simulations to estimate the delivered target dose with rigid motion. Treatment simulations were performed with and without a repainting scheme designed to mitigate interplay effects. Including rigid motion, the achieved CTV mean dose after three fractions delivered without repainting was on average (±SD) 24.8 ± 8.4% higher and the D 98% was 16.2 ± 11.3% higher for non-uniform plans than for uniform plans. The interplay-induced increase in D 2% relative to the static plans was reduced from 3.2 ± 4.1% without repainting to −0.5 ± 1.7% with repainting for non-uniform plans and from 1.5 ± 2.0% to 0.1 ± 1.3% for uniform plans. Considerable differences were observed between estimated CTV doses based on 4DCT motion and intra-treatment motion. In conclusion, non-uniform dose prescription in proton SBRT may provide considerably higher tumor doses than uniform prescription for the same complication risk. Due to motion variability, target doses estimated from 4DCT motion may not accurately reflect the delivered dose. Future studies including modelling of deformations and associated range uncertainties are warranted to confirm the findings.
- 20 August 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 121 (1) , 75-78
Fiducial marker guided stereotactic liver radiotherapy: Is a time delay between marker implantation and planning CT needed?
- 20 August 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 121 (1) , 75-78
Fiducial marker guided stereotactic liver radiotherapy: Is a time delay between marker implantation and planning CT needed?
- Open Access
- 23 July 2013
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 52 (7) , 1437-1444
Variations in magnitude and directionality of respiratory target motion throughout full treatment courses of stereotactic body radiotherapy for tumors in the liver
Purpose. To investigate the stability of target motion amplitude and motion directionality throughout full stereotactic body radiotherapy (SBRT) treatments of tumors in the liver. Material and methods. Ten patients with gold markers implanted in the liver received 11 courses of 3-fraction SBRT on a conventional linear accelerator. A four-dimensional computed tomography (4DCT) scan was obtained for treatment planning. The time-resolved marker motion was determined throughout full treatment field delivery using the kV and MV imagers of the accelerator. The motion amplitude and motion directionality of all individual respiratory cycles were determined using principal component analysis (PCA). The variations in motion amplitude and directionality within the treatment courses and the difference from the motion in the 4DCT scan were determined. Results. The patient mean (± 1 standard deviation) peak-to-peak 3D motion amplitude of individual respiratory cycles during a treatment course was 7.9 ± 4.1 mm and its difference from the 4DCT scan was −0.8 ± 2.5 mm (max, 6.6 mm). The mean standard deviation of 3D respiratory cycle amplitude within a treatment course was 2.0 ± 1.6 mm. The motion directionality of individual respiratory cycles on average deviated 4.6 ± 1.6° from the treatment course mean directionality. The treatment course mean motion directionality on average deviated 7.6 ± 6.5° from the directionality in the 4DCT scan. A single patient-specific oblique direction in space explained 97.7 ± 1.7% and 88.3 ± 10.1% of all positional variance (motion) throughout the treatment courses, excluding and including baseline shifts between treatment fields, respectively. Conclusion. Due to variable breathing amplitudes a single 4DCT scan was not always representative of the mean motion amplitude during treatment. However, the motion was highly directional with a fairly stable direction throughout treatment, indicating a potential for more optimal individualized motion margins aligned to the preferred direction of motion.
- 23 July 2013
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 52 (7) , 1437-1444
Open AccessVariations in magnitude and directionality of respiratory target motion throughout full treatment courses of stereotactic body radiotherapy for tumors in the liver
Purpose. To investigate the stability of target motion amplitude and motion directionality throughout full stereotactic body radiotherapy (SBRT) treatments of tumors in the liver. Material and methods. Ten patients with gold markers implanted in the liver received 11 courses of 3-fraction SBRT on a conventional linear accelerator. A four-dimensional computed tomography (4DCT) scan was obtained for treatment planning. The time-resolved marker motion was determined throughout full treatment field delivery using the kV and MV imagers of the accelerator. The motion amplitude and motion directionality of all individual respiratory cycles were determined using principal component analysis (PCA). The variations in motion amplitude and directionality within the treatment courses and the difference from the motion in the 4DCT scan were determined. Results. The patient mean (± 1 standard deviation) peak-to-peak 3D motion amplitude of individual respiratory cycles during a treatment course was 7.9 ± 4.1 mm and its difference from the 4DCT scan was −0.8 ± 2.5 mm (max, 6.6 mm). The mean standard deviation of 3D respiratory cycle amplitude within a treatment course was 2.0 ± 1.6 mm. The motion directionality of individual respiratory cycles on average deviated 4.6 ± 1.6° from the treatment course mean directionality. The treatment course mean motion directionality on average deviated 7.6 ± 6.5° from the directionality in the 4DCT scan. A single patient-specific oblique direction in space explained 97.7 ± 1.7% and 88.3 ± 10.1% of all positional variance (motion) throughout the treatment courses, excluding and including baseline shifts between treatment fields, respectively. Conclusion. Due to variable breathing amplitudes a single 4DCT scan was not always representative of the mean motion amplitude during treatment. However, the motion was highly directional with a fairly stable direction throughout treatment, indicating a potential for more optimal individualized motion margins aligned to the preferred direction of motion.
- 30 June 2010
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 49 (7) , 1177-1183
Inter- and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lung
Background. Localisation errors in cone-beam CT (CBCT) guided stereotactic body radiation therapy (SBRT) were evaluated and compared to positioning using the external coordinates of a stereotactic body frame (SBF) alone. Possible correlations to patient- or treatment-specific factors such as body mass index (BMI), planning time, treatment delivery time, and distance between tumour and spinal cord were explored to determine whether they influenced on the benefit of image-guidance. Material and methods. A total of 34 patients received SBRT (3 fractions) for tumours in the liver (15 patients) or the lung (19 patients). Immobilisation and positioning was obtained with a SBF. Pre- and post-treatment CBCT scans were registered with the bony anatomy of the planning CT to find inter- and intrafractional patient positioning errors (PPE). For lung tumour patients, matching was also performed on the tumours to find the tumour positioning errors (TPE) and baseline shifts relative to bony anatomy. Results. The mean inter- and intrafractional 3D vector PPE was 4.5 ± 2.7 mm (average ± SD) and 1.5 ± 0.6 mm, respectively, for the combined group of patients. For lung tumours, the interfractional misalignment was 5.6 ± 1.8 mm. The baseline shift was 3.9 ± 2.0 mm. Intrafractional TPE and baseline shifts were 2.1 ± 0.7 mm and 1.9 ± 0.6 mm, respectively. The magnitude of interfractional baseline shift was closely correlated with the distance between the tumour and the spinal cord. Intrafractional errors were independent of patient BMI, age or gender. Conclusion. Image-guidance reduced setup errors considerably. The study demonstrated the benefit of CBCT-guidance regardless of patient specific factors such as BMI, age or gender. Protection of the spinal cord was facilitated by the correlation between the tumour position relative to the spinal cord and the magnitude of baseline shift.
- 30 June 2010
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 49 (7) , 1177-1183
Inter- and intrafractional localisation errors in cone-beam CT guided stereotactic radiation therapy of tumours in the liver and lung
Background. Localisation errors in cone-beam CT (CBCT) guided stereotactic body radiation therapy (SBRT) were evaluated and compared to positioning using the external coordinates of a stereotactic body frame (SBF) alone. Possible correlations to patient- or treatment-specific factors such as body mass index (BMI), planning time, treatment delivery time, and distance between tumour and spinal cord were explored to determine whether they influenced on the benefit of image-guidance. Material and methods. A total of 34 patients received SBRT (3 fractions) for tumours in the liver (15 patients) or the lung (19 patients). Immobilisation and positioning was obtained with a SBF. Pre- and post-treatment CBCT scans were registered with the bony anatomy of the planning CT to find inter- and intrafractional patient positioning errors (PPE). For lung tumour patients, matching was also performed on the tumours to find the tumour positioning errors (TPE) and baseline shifts relative to bony anatomy. Results. The mean inter- and intrafractional 3D vector PPE was 4.5 ± 2.7 mm (average ± SD) and 1.5 ± 0.6 mm, respectively, for the combined group of patients. For lung tumours, the interfractional misalignment was 5.6 ± 1.8 mm. The baseline shift was 3.9 ± 2.0 mm. Intrafractional TPE and baseline shifts were 2.1 ± 0.7 mm and 1.9 ± 0.6 mm, respectively. The magnitude of interfractional baseline shift was closely correlated with the distance between the tumour and the spinal cord. Intrafractional errors were independent of patient BMI, age or gender. Conclusion. Image-guidance reduced setup errors considerably. The study demonstrated the benefit of CBCT-guidance regardless of patient specific factors such as BMI, age or gender. Protection of the spinal cord was facilitated by the correlation between the tumour position relative to the spinal cord and the magnitude of baseline shift.