Markus Weininger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Markus Weininger has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Philip Costello
Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Dr., Charleston, SC 29401
2 shared publicationsU. Joseph Schoepf
Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Dr., Charleston, SC 29401
2 shared publicationsAlessandro Cianfoni
Department of Radiology and Radiological Science, Medical University of South Carolina, 96 Jonathan Lucas St, MSC 323, Charleston, SC 29425
1 shared publicationBalasz Ruzsics
Medical University of South Carolina
1 shared publicationCorey A. Kemper
Informatics Research, Medrad, Indianola, PA
1 shared publicationDietbert Hahn
1 shared publication
Latest Publications
- 1 March 2013
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 200 (3) , 673-676
Accuracy of CT Guidance of Lumbar Facet Joint Block
OBJECTIVE. Lumbar facet joint block is generally performed under fluoroscopic guidance. The purpose of this study was to assess the technical success rate of facet joint block under CT guidance. The CT scanner was operated tableside with a step-and-shoot mode for intermittent needle visualization, and the amount of radiation used to perform the procedures was estimated. CONCLUSION. CT-guided facet joint block is safe and rapid. Use of CT ensures reliable needle guidance with extremely high procedural accuracy at an effective radiation dose comparable to that of a procedure performed with 1 minute of fluoroscopic guidance.
- 1 March 2013
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 200 (3) , 673-676
Accuracy of CT Guidance of Lumbar Facet Joint Block
OBJECTIVE. Lumbar facet joint block is generally performed under fluoroscopic guidance. The purpose of this study was to assess the technical success rate of facet joint block under CT guidance. The CT scanner was operated tableside with a step-and-shoot mode for intermittent needle visualization, and the amount of radiation used to perform the procedures was estimated. CONCLUSION. CT-guided facet joint block is safe and rapid. Use of CT ensures reliable needle guidance with extremely high procedural accuracy at an effective radiation dose comparable to that of a procedure performed with 1 minute of fluoroscopic guidance.
- 1 March 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 196 (3) , W260-W272
Cardiothoracic CT Angiography: Current Contrast Medium Delivery Strategies
OBJECTIVE. Over the last decade, rapid technologic evolution in CT has resulted in improved spatial and temporal resolution and acquisition speed, enabling cardiothoracic CT angiography to become a viable and effective noninvasive alternative in the diagnostic algorithm. These new technologic advances have imposed new challenges for the optimization of contrast medium delivery and image acquisition strategies.CONCLUSION. Thorough understanding of contrast medium dynamics is essential for the design of effective acquisition and injection protocols. This article provides an overview of the fundamentals affecting contrast enhancement, emphasizing the modifications to contrast material delivery protocols required to optimize cardiothoracic CT angiography.
- 1 March 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 196 (3) , W260-W272
Cardiothoracic CT Angiography: Current Contrast Medium Delivery Strategies
OBJECTIVE. Over the last decade, rapid technologic evolution in CT has resulted in improved spatial and temporal resolution and acquisition speed, enabling cardiothoracic CT angiography to become a viable and effective noninvasive alternative in the diagnostic algorithm. These new technologic advances have imposed new challenges for the optimization of contrast medium delivery and image acquisition strategies.CONCLUSION. Thorough understanding of contrast medium dynamics is essential for the design of effective acquisition and injection protocols. This article provides an overview of the fundamentals affecting contrast enhancement, emphasizing the modifications to contrast material delivery protocols required to optimize cardiothoracic CT angiography.
- 10 January 2011
- Published by Taylor & Francis in Expert Review of Cardiovascular Therapy
- Vol. 9 (1) , 27-43
Integrative computed tomographic imaging of coronary artery disease
Rapid technological evolution in multislice computed tomography (CT) over the last decade with improved spatial and temporal resolution has enabled cardiac CT to become a viable and effective alternative in the diagnosis of coronary artery disease. Within recent years CT coronary angiography has demonstrated high sensitivity and specificity, and in particular a very high negative-predictive value, making it a valuable imaging modality for ruling out suspected coronary artery disease. In addition, CT angiography demonstrates accuracy in the detection and characterization of coronary plaques, and it has been reported to play an important role in predicting disease progression and cardiac events. The goal of this article is to provide an overview on the role and current clinical applications of cardiac CT in the evaluation of coronary artery disease. Emerging areas of cardiac CT, including dual-energy CT and CT myocardial perfusion are also discussed, as well as the limitations and future directions of cardiac CT.
- 10 January 2011
- Published by Taylor & Francis in Expert Review of Cardiovascular Therapy
- Vol. 9 (1) , 27-43
Integrative computed tomographic imaging of coronary artery disease
Rapid technological evolution in multislice computed tomography (CT) over the last decade with improved spatial and temporal resolution has enabled cardiac CT to become a viable and effective alternative in the diagnosis of coronary artery disease. Within recent years CT coronary angiography has demonstrated high sensitivity and specificity, and in particular a very high negative-predictive value, making it a valuable imaging modality for ruling out suspected coronary artery disease. In addition, CT angiography demonstrates accuracy in the detection and characterization of coronary plaques, and it has been reported to play an important role in predicting disease progression and cardiac events. The goal of this article is to provide an overview on the role and current clinical applications of cardiac CT in the evaluation of coronary artery disease. Emerging areas of cardiac CT, including dual-energy CT and CT myocardial perfusion are also discussed, as well as the limitations and future directions of cardiac CT.
- 1 January 2011
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 46 (1) , 1-10
Hemodynamic Assessment of Severe Aortic Stenosis
Direct magnetic resonance imaging (MRI) planimetry of the maximal systolic aortic valve area does not consider temporal variations of the opening area during the ejection period. We evaluated an MRI-based methodology for the assessment of valvular dynamics in patients with severe aortic stenosis by measuring the systolic variability of the valvular blood stream, that is, the “vena contracta.” With institutional review board approval, we examined 22 patients (13 male, 9 female; mean age, 68 ±10 years) with severe aortic stenosis using 1.5 T MRI and a standardized scanning protocol consisting of gradient-echo phase-contrast velocity imaging and steady-state free precession-cine MRI before and after valve replacement therapy. Temporal changes of the aortic valve area, represented by systolic variations of the area of poststenotic turbulent flow at its smallest convergence, that is, the proximal vena contracta, were determined by MRI and quantified by a calculated parameter of temporal valve dynamics (T). T was defined as the period which the aortic valve spent over its maximal opening area (>85%) during systole. MRI was also used to determine left ventricular hypertrophy before (LVMI) and its regression (LVMR) after valve replacement. Findings were compared with transthoracic echocardiography and cardiac catheterization. All patients had an echocardiographic effective orifice area, EOATTE, of <1.0 cm2. The comparison of T to LVMI and LVMR revealed significant correlations (LVMI: r = −0.62; P = 0.002; LVMR: r = 0.62; P = 0.002). Further significant correlations with aortic stenosis severity were observed in the comparison with manual planimetry, invasive measurements, and echocardiographic valve areas, as well as with pressure gradients. MRI can measure systolic variations of the aortic valve area. Quantitative parameters of the hemodynamic relevance of valve dynamics obtained by this method correlate with established parameters of aortic stenosis severity and LVMR.
- 1 January 2011
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 46 (1) , 1-10
Hemodynamic Assessment of Severe Aortic Stenosis
Direct magnetic resonance imaging (MRI) planimetry of the maximal systolic aortic valve area does not consider temporal variations of the opening area during the ejection period. We evaluated an MRI-based methodology for the assessment of valvular dynamics in patients with severe aortic stenosis by measuring the systolic variability of the valvular blood stream, that is, the “vena contracta.” With institutional review board approval, we examined 22 patients (13 male, 9 female; mean age, 68 ±10 years) with severe aortic stenosis using 1.5 T MRI and a standardized scanning protocol consisting of gradient-echo phase-contrast velocity imaging and steady-state free precession-cine MRI before and after valve replacement therapy. Temporal changes of the aortic valve area, represented by systolic variations of the area of poststenotic turbulent flow at its smallest convergence, that is, the proximal vena contracta, were determined by MRI and quantified by a calculated parameter of temporal valve dynamics (T). T was defined as the period which the aortic valve spent over its maximal opening area (>85%) during systole. MRI was also used to determine left ventricular hypertrophy before (LVMI) and its regression (LVMR) after valve replacement. Findings were compared with transthoracic echocardiography and cardiac catheterization. All patients had an echocardiographic effective orifice area, EOATTE, of <1.0 cm2. The comparison of T to LVMI and LVMR revealed significant correlations (LVMI: r = −0.62; P = 0.002; LVMR: r = 0.62; P = 0.002). Further significant correlations with aortic stenosis severity were observed in the comparison with manual planimetry, invasive measurements, and echocardiographic valve areas, as well as with pressure gradients. MRI can measure systolic variations of the aortic valve area. Quantitative parameters of the hemodynamic relevance of valve dynamics obtained by this method correlate with established parameters of aortic stenosis severity and LVMR.
- 22 September 2010
- Published by Springer Nature
- p. 111-124
Myocardial Perfusion