Bo Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bo Wang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Changpei Qiu
The Key Laboratory of Integrated Microsystems, Peking University Shenzhen Graduate School, Shenzhen 518055, China
2 shared publications Hanyu Wang
Key Laboratory of Integrated Microsystems, School of Electronic and Computer Engineering, Peking University, Shenzhen Graduate School, Shenzhen, China
2 shared publicationsKe Lin
Key Laboratory of Microsystem, Peking University Shenzhen Graduate School, Shenzhen, China
2 shared publicationsMiao Qi
Key Laboratory of Integrated Microsystems, School of Electronic and Computer Engineering, Peking University, Shenzhen Graduate School, Shenzhen, China
2 shared publications- Qiuping Li
The Key Laboratory of Integrated Microsystems, Peking University Shenzhen Graduate School, Shenzhen 518055, China
2 shared publications - Tianxia Zhao
The Key Laboratory of Integrated Microsystems, Peking University Shenzhen Graduate School, Shenzhen 518055, China
2 shared publications
Latest Publications
- RetractedOpen Access
- 3 March 2021
- Published by Hindawi Limited in Journal of Healthcare Engineering
- Vol. 2021, 1-16
Study on Potential of Meridian Acupoints of Traditional Chinese Medicine
In recent years, Traditional Chinese Medicine (TCM) has attracted more and more attention due to its good therapeutic effect, low cost, and convenience. This research is also a part of the goal of the modernization of TCM. Based on the meridian electric potential acquisition system independently developed by our project team, in this paper, we designed the human body's meridian electric potential acquisition scheme. We use principal component analysis (PCA) to prove that the meridional potential signal is derived from the ECG signal. Then, Inception ResNet V2 was used to classify acupoints and nonacupoints. Finally, the classification accuracy rate reached 86.59045265, and the F1 score = 0.72161642. This shows that acupoints and nonacupoints can be distinguished by their surface potential.
- 3 March 2021
- Published by Hindawi Limited in Journal of Healthcare Engineering
- Vol. 2021, 1-16
RetractedOpen AccessStudy on Potential of Meridian Acupoints of Traditional Chinese Medicine
In recent years, Traditional Chinese Medicine (TCM) has attracted more and more attention due to its good therapeutic effect, low cost, and convenience. This research is also a part of the goal of the modernization of TCM. Based on the meridian electric potential acquisition system independently developed by our project team, in this paper, we designed the human body's meridian electric potential acquisition scheme. We use principal component analysis (PCA) to prove that the meridional potential signal is derived from the ECG signal. Then, Inception ResNet V2 was used to classify acupoints and nonacupoints. Finally, the classification accuracy rate reached 86.59045265, and the F1 score = 0.72161642. This shows that acupoints and nonacupoints can be distinguished by their surface potential.
- RetractedOpen Access
- 6 January 2021
- Published by Hindawi Limited in Journal of Healthcare Engineering
- Vol. 2021, 1-9
A Low-Power Stable Wideband Current Source for Acupuncture Point Skin Impedance Measurements
A low-power stable wideband current source for acupuncture point skin impedance measurements has been designed employing a differential architecture and negative feedback. The circuits extend bandwidth to 1MHz, reducing harmonic distortion to 0.24 at 1MHz. The output impedance is 37M at 100kHz and 11M at 1MHz. The stability of the output current of the current source when connected to different loads is below 0.1 at frequencies up to 500kHz and increases to 0.74 at 1MHz. The circuit was manufactured in a 0.13-μm CMOS technology and measured results are presented. The area of the current source is 0.09mm2 and its consumption is 1.2mW. It is intended for low-power acupuncture point skin impedance measurements.
- 6 January 2021
- Published by Hindawi Limited in Journal of Healthcare Engineering
- Vol. 2021, 1-9
RetractedOpen AccessA Low-Power Stable Wideband Current Source for Acupuncture Point Skin Impedance Measurements
A low-power stable wideband current source for acupuncture point skin impedance measurements has been designed employing a differential architecture and negative feedback. The circuits extend bandwidth to 1MHz, reducing harmonic distortion to 0.24 at 1MHz. The output impedance is 37M at 100kHz and 11M at 1MHz. The stability of the output current of the current source when connected to different loads is below 0.1 at frequencies up to 500kHz and increases to 0.74 at 1MHz. The circuit was manufactured in a 0.13-μm CMOS technology and measured results are presented. The area of the current source is 0.09mm2 and its consumption is 1.2mW. It is intended for low-power acupuncture point skin impedance measurements.
- 19 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 64 (6) , 610-614
PPV Modeling of Memristor-Based Oscillators and Application to ONN Pattern Recognition
An efficient perturbation projection vector (PPV) modeling for a memristor-based oscillator is proposed and then applied to the simulation of the oscillatory neural network (ONN) for pattern recognition. Compared with the existing model, which is very time consuming, this novel modeling method features a fast and accurate simulation of a large-scale network with many oscillators. The proposed modeling is based on a highly efficient abstraction of the phase sensitivity characteristic of the memristor-based oscillator, i.e., its PPV, which enables reducing the complexity of the ONN description, speeding up the simulation considerably while retaining comparable precision.
- 19 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 64 (6) , 610-614
PPV Modeling of Memristor-Based Oscillators and Application to ONN Pattern Recognition
An efficient perturbation projection vector (PPV) modeling for a memristor-based oscillator is proposed and then applied to the simulation of the oscillatory neural network (ONN) for pattern recognition. Compared with the existing model, which is very time consuming, this novel modeling method features a fast and accurate simulation of a large-scale network with many oscillators. The proposed modeling is based on a highly efficient abstraction of the phase sensitivity characteristic of the memristor-based oscillator, i.e., its PPV, which enables reducing the complexity of the ONN description, speeding up the simulation considerably while retaining comparable precision.
- 4 January 2017
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (10) , 4459-4473
A novel low-power compact WBS human body channel receiver for wearable vital signal sensing application in wireless body-area network
- 4 January 2017
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (10) , 4459-4473
A novel low-power compact WBS human body channel receiver for wearable vital signal sensing application in wireless body-area network
- 2 March 2016
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (5) , 1443-1451
An FPC based flexible dry electrode with stacked double-micro-domes array for wearable biopotential recording system
- 2 March 2016
- Published by Springer Nature in Microsystem Technologies
- Vol. 23 (5) , 1443-1451
An FPC based flexible dry electrode with stacked double-micro-domes array for wearable biopotential recording system
- Open Access
PPV modelling of memristor-based oscillator
In this letter, we propose for the first time a method of abstracting the PPV (Perturbation Projection Vector) characteristic of the up-to-date memristor-based oscillators. Inspired from biological oscillators and its characteristic named PRC (Phase Response Curve), we build a bridge between PRC and PPV. This relationship is verified rigorously using the transistor level simulation of Colpitts and ring oscillators, i.e., comparing the PPV converted from PRC and the PPV obtained from accurate PSS+PXF simulation. Then we apply this method to the PPV calculation of the memristor-based oscillator. By keeping the phase dynamics of the oscillator and dropping the details of voltage/current amplitude, the PPV modelling is highly efficient to describe the phase dynamics due to the oscillator coupling, and will be very suitable for the fast simulation of large scale oscillatory neural networks.
Open AccessPPV modelling of memristor-based oscillator
In this letter, we propose for the first time a method of abstracting the PPV (Perturbation Projection Vector) characteristic of the up-to-date memristor-based oscillators. Inspired from biological oscillators and its characteristic named PRC (Phase Response Curve), we build a bridge between PRC and PPV. This relationship is verified rigorously using the transistor level simulation of Colpitts and ring oscillators, i.e., comparing the PPV converted from PRC and the PPV obtained from accurate PSS+PXF simulation. Then we apply this method to the PPV calculation of the memristor-based oscillator. By keeping the phase dynamics of the oscillator and dropping the details of voltage/current amplitude, the PPV modelling is highly efficient to describe the phase dynamics due to the oscillator coupling, and will be very suitable for the fast simulation of large scale oscillatory neural networks.
- 8 November 2011
- Published by Springer Nature
- p. 91-104
Bottom-up Verification for CMOS Photonic Linear Heterogeneous System
- 8 November 2011
- Published by Springer Nature
- p. 91-104
Bottom-up Verification for CMOS Photonic Linear Heterogeneous System