Jianyong Ai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jianyong Ai has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Wenbo Ding
Shanghai Center for Mathematical Sciences, Fudan University, No. 220 Handan Road, Shanghai 200433, China
2 shared publications - Chengyang Ying
Department of Computer Science & Technology, Institute for AI, BNRist Center, THBI Lab, Tsinghua-Bosch Joint Center for ML, Tsinghua University, Beijing, China
1 shared publication Gangjie Zhou
School of Electronic and Information Engineering, Tongji University, Shanghai, China
1 shared publicationHang Su
1 shared publication- Jiachen Zhong
Zhejiang Wuzhou Engineering Project Management Co., Ltd, Hangzhou, 310051, China
1 shared publication Jiuhua Zhao
1 shared publication
Latest Publications
- 7 March 2023
- Published by Elsevier in Pattern Recognition Letters
- Vol. 168, 57-63
Consistent attack: Universal adversarial perturbation on embodied vision navigation
- 7 March 2023
- Published by Elsevier in Pattern Recognition Letters
- Vol. 168, 57-63
Consistent attack: Universal adversarial perturbation on embodied vision navigation
- Open Access
WS-3D-Lane: Weakly Supervised 3D Lane Detection With 2D Lane Labels
Compared to 2D lanes, real 3D lane data is difficult to collect accurately. In this paper, we propose a novel method for training 3D lanes with only 2D lane labels, called weakly supervised 3D lane detection WS-3D-Lane. By assumptions of constant lane width and equal height on adjacent lanes, we indirectly supervise 3D lane heights in the training. To overcome the problem of the dynamic change of the camera pitch during data collection, a camera pitch self-calibration method is proposed. In anchor representation, we propose a double-layer anchor with a improved non-maximum suppression (NMS) method, which enables the anchor-based method to predict two lane lines that are close. Experiments are conducted on the base of 3D-LaneNet under two supervision methods. Under weakly supervised setting, our WS-3D-Lane outperforms previous 3D-LaneNet: F-score rises to 92.3% on Apollo 3D synthetic dataset, and F1 rises to 74.5% on ONCE-3DLanes. Meanwhile, WS-3D-Lane in purely supervised setting makes more increments and outperforms state-of-the-art. To the best of our knowledge, WS-3D-Lane is the first try of 3D lane detection under weakly supervised setting.
Open AccessWS-3D-Lane: Weakly Supervised 3D Lane Detection With 2D Lane Labels
Compared to 2D lanes, real 3D lane data is difficult to collect accurately. In this paper, we propose a novel method for training 3D lanes with only 2D lane labels, called weakly supervised 3D lane detection WS-3D-Lane. By assumptions of constant lane width and equal height on adjacent lanes, we indirectly supervise 3D lane heights in the training. To overcome the problem of the dynamic change of the camera pitch during data collection, a camera pitch self-calibration method is proposed. In anchor representation, we propose a double-layer anchor with a improved non-maximum suppression (NMS) method, which enables the anchor-based method to predict two lane lines that are close. Experiments are conducted on the base of 3D-LaneNet under two supervision methods. Under weakly supervised setting, our WS-3D-Lane outperforms previous 3D-LaneNet: F-score rises to 92.3% on Apollo 3D synthetic dataset, and F1 rises to 74.5% on ONCE-3DLanes. Meanwhile, WS-3D-Lane in purely supervised setting makes more increments and outperforms state-of-the-art. To the best of our knowledge, WS-3D-Lane is the first try of 3D lane detection under weakly supervised setting.
- 1 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (6) , 3714-3723
Probability Calculation of Pollution Flashover on Insulators and Analysis of Environmental Factors
Insulator pollution flashover occurs frequently and is harmful to the power transmission and distribution network. But the randomness of the pollution flashover and the complex influencing factors make it difficult to be predicted. The objective of this paper is to study the mechanism of the discharging on insulator surfaces and design a the calculation method which derives flashover probability. By calculating the distorted electric field in the initial streamer discharge quantitatively and combining it with the equivalent circuit of the insulator surface, the initial discharge voltage is derived. By analyzing the change in power input and dissipation in the process of the arc discharge, we propose the criterion on arc development and extinction, and the critical flashover conductivity of the insulator is obtained. Based on the probability density function, the behavior of the factors on the critical flashover conductivity is described, and the probability of insulator pollution flashover is calculated under different environmental conditions. In the validation experiment, the measured initial discharge voltage and pollution flashover ratio are close to the calculated values. The methods proposed in this paper could be used in the quantitative calculation of the initial discharge voltage and the prevention of the pollution flashover on insulators.
- 1 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (6) , 3714-3723
Probability Calculation of Pollution Flashover on Insulators and Analysis of Environmental Factors
Insulator pollution flashover occurs frequently and is harmful to the power transmission and distribution network. But the randomness of the pollution flashover and the complex influencing factors make it difficult to be predicted. The objective of this paper is to study the mechanism of the discharging on insulator surfaces and design a the calculation method which derives flashover probability. By calculating the distorted electric field in the initial streamer discharge quantitatively and combining it with the equivalent circuit of the insulator surface, the initial discharge voltage is derived. By analyzing the change in power input and dissipation in the process of the arc discharge, we propose the criterion on arc development and extinction, and the critical flashover conductivity of the insulator is obtained. Based on the probability density function, the behavior of the factors on the critical flashover conductivity is described, and the probability of insulator pollution flashover is calculated under different environmental conditions. In the validation experiment, the measured initial discharge voltage and pollution flashover ratio are close to the calculated values. The methods proposed in this paper could be used in the quantitative calculation of the initial discharge voltage and the prevention of the pollution flashover on insulators.
- 5 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 67 (6) , 1349-1358
Condition Evaluation of the Contaminated Insulators by Visible Light Images Assisted With Infrared Information
Pollution flashover is harmful and has caused huge economic losses. Thus, it is important to evaluate the contamination condition of insulators to prevent the pollution flashover. The objective of this paper is to discriminate the insulator contamination grades by the noncontact method. In this paper, a method of visible light images assisted with infrared information is proposed. The proposed method evaluates the contamination condition using the visible light images, and is corrected by the infrared information in the wet environment. A mathematical model is established to study the relationship between the equivalent salt deposit density (ESDD) (mg/cm²) and the color features. The influences of illumination L and relative humidity (RH) on the color features are analyzed and their eliminated methods are proposed. The infrared image information is proposed to assist the visible light image method when RH ≥ 60%. In the experiment, the visible light images of the artificial polluted insulators are acquired by a digital camera under different illuminations L and RHs, and the average value of V component Vave in the YUV color space is selected for the discrimination of contamination grades. In the test, the proposed method gives an 84% accuracy rate when RH < 60% and gives an 89% accuracy rate when RH ≥ 60%. Finally, naturally polluted insulators were tested. The general test error of ESDD is about 0.0119 mg/cm². Therefore, it might be concluded the condition of naturally polluted insulators could be evaluated by the proposed method of visible light images assisted with infrared information.
- 5 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 67 (6) , 1349-1358
Condition Evaluation of the Contaminated Insulators by Visible Light Images Assisted With Infrared Information
Pollution flashover is harmful and has caused huge economic losses. Thus, it is important to evaluate the contamination condition of insulators to prevent the pollution flashover. The objective of this paper is to discriminate the insulator contamination grades by the noncontact method. In this paper, a method of visible light images assisted with infrared information is proposed. The proposed method evaluates the contamination condition using the visible light images, and is corrected by the infrared information in the wet environment. A mathematical model is established to study the relationship between the equivalent salt deposit density (ESDD) (mg/cm²) and the color features. The influences of illumination L and relative humidity (RH) on the color features are analyzed and their eliminated methods are proposed. The infrared image information is proposed to assist the visible light image method when RH ≥ 60%. In the experiment, the visible light images of the artificial polluted insulators are acquired by a digital camera under different illuminations L and RHs, and the average value of V component Vave in the YUV color space is selected for the discrimination of contamination grades. In the test, the proposed method gives an 84% accuracy rate when RH < 60% and gives an 89% accuracy rate when RH ≥ 60%. Finally, naturally polluted insulators were tested. The general test error of ESDD is about 0.0119 mg/cm². Therefore, it might be concluded the condition of naturally polluted insulators could be evaluated by the proposed method of visible light images assisted with infrared information.