Jean-Laurent Gardarein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jean-Laurent Gardarein has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Arnaud Hays
Aix Marseille Univ, Université de Toulon, CNRS, Institut Paoli‐Calmettes, HIPE Human Lab Marseille France
2 shared publications - Dorian Giraud
CNRS, Université de Toulon, Institut Paoli- Calmettes, HIPE HumanLab, N°202324378C, Aix-Marseille Univ, Marseille, France
2 shared publications Aïmen E. Gheribi
CRCT—Center for Research in Computational Thermochemistry, Polytechnique Montreal 1 , Box 6079, Station Downtown, Montreal, Quebec H3C 3A7, Canada
1 shared publicationC. Pocheau
CEA, IRFM, F-13108 Saint-Paul-lez-Durance, France
1 shared publication- Caroline Nicol
National Center for Scientific Research (CNRS), Institute of Movement Sciences (ISM, UMR 7287), Aix-Marseille University, Marseille, France; and
1 shared publication D. Guilhem
CEA, IRFM, F-13108 Saint-Paul-lez-Durance, France
1 shared publication
Latest Publications
- Open Access
Noninvasive thigh temperature mapping after cold water immersion and subsequent exercise using magnetic resonance spectrometry
Heat-related illnesses pose a significant public health challenge in Europe, resulting in increased mortality. Although cold water immersion (CWI) is the most effective treatment for heat stroke, its clinical use is limited. A better understanding of temperature changes in the peripheral body regions can lead to more effective CWI application. Nevertheless, most muscle temperature measurement techniques are invasive. This study evaluated magnetic resonance spectroscopy (MRS) for non-invasive assessment of intramuscular temperature during cold stress and rewarming. Nine healthy volunteers (7 men, 2 women) participated in three 3T MRI sessions: baseline (PRE), immediately after 15 minutes of CWI at 10 degrees to the iliac crest (POST-CWI), and following 100-Watt cycling (POST-cycling). Each scan session included T1w and localized spectroscopy acquisitions in the right thigh. Absolute temperature was estimated from the proton resonance frequency shift between water and creatine peaks. The measurements were split into three groups of voxels, defined as follows: close to the top (TL), bottom (BL), or central (DL) thigh positions. Measurement depth showed a location main effect (p<0.001, ηp^2=0.40), with DL (35.4[5.9] mm) significantly deeper than TL (22.5[4.2] mm) and BL (25.3[5.1] mm), remaining constant across phases. Temperature decreased significantly from PRE to POST-CWI across all locations (TL: p<0.001, d=2.74; BL: p<0.001, d=1.84; DL: p<0.005, d=1.14). Post-cycling temperature increased at all sites compared to POST-CWI (DL: p=0.040, d=1.06; TL: p<0.001, d=1.7; BL: p<0.001, d=1.80), though TL remained lower than PRE (p<0.017, d=1.48). During POST-CWI, DL showed a significantly higher temperature than TL (p<0.001, d=2.13) and BL (p<0.001, d=2.06). These findings demonstrate that MRS-based temperature mapping provides unique anatomical and thermal characterization of muscle during thermoregulatory stress. While results are promising for understanding CWI mechanisms, validation in larger cohorts is necessary to establish clinical reliability and reproducibility for heat illness management.
Open AccessNoninvasive thigh temperature mapping after cold water immersion and subsequent exercise using magnetic resonance spectrometry
Heat-related illnesses pose a significant public health challenge in Europe, resulting in increased mortality. Although cold water immersion (CWI) is the most effective treatment for heat stroke, its clinical use is limited. A better understanding of temperature changes in the peripheral body regions can lead to more effective CWI application. Nevertheless, most muscle temperature measurement techniques are invasive. This study evaluated magnetic resonance spectroscopy (MRS) for non-invasive assessment of intramuscular temperature during cold stress and rewarming. Nine healthy volunteers (7 men, 2 women) participated in three 3T MRI sessions: baseline (PRE), immediately after 15 minutes of CWI at 10 degrees to the iliac crest (POST-CWI), and following 100-Watt cycling (POST-cycling). Each scan session included T1w and localized spectroscopy acquisitions in the right thigh. Absolute temperature was estimated from the proton resonance frequency shift between water and creatine peaks. The measurements were split into three groups of voxels, defined as follows: close to the top (TL), bottom (BL), or central (DL) thigh positions. Measurement depth showed a location main effect (p<0.001, ηp^2=0.40), with DL (35.4[5.9] mm) significantly deeper than TL (22.5[4.2] mm) and BL (25.3[5.1] mm), remaining constant across phases. Temperature decreased significantly from PRE to POST-CWI across all locations (TL: p<0.001, d=2.74; BL: p<0.001, d=1.84; DL: p<0.005, d=1.14). Post-cycling temperature increased at all sites compared to POST-CWI (DL: p=0.040, d=1.06; TL: p<0.001, d=1.7; BL: p<0.001, d=1.80), though TL remained lower than PRE (p<0.017, d=1.48). During POST-CWI, DL showed a significantly higher temperature than TL (p<0.001, d=2.13) and BL (p<0.001, d=2.06). These findings demonstrate that MRS-based temperature mapping provides unique anatomical and thermal characterization of muscle during thermoregulatory stress. While results are promising for understanding CWI mechanisms, validation in larger cohorts is necessary to establish clinical reliability and reproducibility for heat illness management.
- Open Access
- 8 February 2024
- Published by Taylor & Francis in Temperature
- Vol. 11 (2) , 137-156
Mechanism involved of post-exercise cold water immersion: Blood redistribution and increase in energy expenditure during rewarming
Thermogenesis is well understood, but the relationships between cold water immersion (CWI), the post-CWI rewarming and the associated physiological changes are not. This study investigated muscle and systemic oxygenation, cardiorespiratory and hemodynamic responses, and gastrointestinal temperature during and after CWI. 21 healthy men completed randomly 2 protocols. Both protocols consisted of a 48 minutes heating cycling exercise followed by 3 recovery periods (R1-R3), but they differed in R2. R1 lasted 20 minutes in a passive semi-seated position on a physiotherapy table at ambient room temperature. Depending on the protocol, R2 lasted 15 minutes at either ambient condition (R2_AMB) or in a CWI condition at 10°C up to the iliac crest (R2_CWI). R3 lasted 40 minutes at AMB while favoring rewarming after R2_CWI. This was followed by 10 minutes of cycling. Compared to R2_AMB, R2_CWI ended at higher O2 in the non-immersed body part due to thermogenesis (7.16(2.15) vs. 4.83(1.62) ml.min−1.kg−1) and lower femoral artery blood flow (475(165) vs. 704(257) ml.min−1) (p < 0.001). Only after CWI, R3 showed a progressive decrease in vastus and gastrocnemius medialis O2 saturation, significant after 34 minutes (p < 0.001). As blood flow did not differ from the AMB protocol, this indicated local thermogenesis in the immersed part of the body. After CWI, a lower gastrointestinal temperature on resumption of cycling compared to AMB (36.31(0.45) vs. 37.30(0.49) °C, p < 0.001) indicated incomplete muscle thermogenesis. In conclusion, the rewarming period after CWI was non-linear and metabolically costly. Immersion and rewarming should be considered as a continuum rather than separate events.- 8 February 2024
- Published by Taylor & Francis in Temperature
- Vol. 11 (2) , 137-156
Open AccessMechanism involved of post-exercise cold water immersion: Blood redistribution and increase in energy expenditure during rewarming
Thermogenesis is well understood, but the relationships between cold water immersion (CWI), the post-CWI rewarming and the associated physiological changes are not. This study investigated muscle and systemic oxygenation, cardiorespiratory and hemodynamic responses, and gastrointestinal temperature during and after CWI. 21 healthy men completed randomly 2 protocols. Both protocols consisted of a 48 minutes heating cycling exercise followed by 3 recovery periods (R1-R3), but they differed in R2. R1 lasted 20 minutes in a passive semi-seated position on a physiotherapy table at ambient room temperature. Depending on the protocol, R2 lasted 15 minutes at either ambient condition (R2_AMB) or in a CWI condition at 10°C up to the iliac crest (R2_CWI). R3 lasted 40 minutes at AMB while favoring rewarming after R2_CWI. This was followed by 10 minutes of cycling. Compared to R2_AMB, R2_CWI ended at higher O2 in the non-immersed body part due to thermogenesis (7.16(2.15) vs. 4.83(1.62) ml.min−1.kg−1) and lower femoral artery blood flow (475(165) vs. 704(257) ml.min−1) (p < 0.001). Only after CWI, R3 showed a progressive decrease in vastus and gastrocnemius medialis O2 saturation, significant after 34 minutes (p < 0.001). As blood flow did not differ from the AMB protocol, this indicated local thermogenesis in the immersed part of the body. After CWI, a lower gastrointestinal temperature on resumption of cycling compared to AMB (36.31(0.45) vs. 37.30(0.49) °C, p < 0.001) indicated incomplete muscle thermogenesis. In conclusion, the rewarming period after CWI was non-linear and metabolically costly. Immersion and rewarming should be considered as a continuum rather than separate events. - 1 June 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (6) , 063508
Integration of fiber Bragg grating temperature sensors in plasma facing components of the WEST tokamak
Plasma Facing Components (PFC) temperature measurement is mandatory to ensure safe high power and long pulse tokamak operation. IR thermography systems which are widely used in magnetic fusions devices become challenged with the choice of tungsten as a PFC material in the ITER tokamak, mainly due to emissivity uncertainties and reflection issues in a hot environment. Embedded temperature measurements are foreseen to cross-check the IR thermography measurements. Fiber Bragg grating sensors are potentially of great interest for this application because they are immune to electromagnetic interference and allow the measurement of a large number of temperature spots on a single fiber. Four optical fiber temperature sensing probes, each of them including 11 regenerated fiber Bragg gratings equally spaced by 12.5 mm (equivalent to one ITER-like tungsten monoblock), have been specifically designed and manufactured for the WEST project (W-tungsten Environment and Steady State Tokamak). The four probes are embedded in W-coated graphite components at two different distances from the surface, 3.5 mm and 7 mm, to cover a wide range of temperatures up to 900 °C. This paper addresses the design and integration issues and the qualification and performance assessment performed in the laboratory. It also shows the first measurements of this new diagnostic achieved in a tokamak environment during baking of the machine and during early diverted plasma exposure.
- 1 June 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (6) , 063508
Integration of fiber Bragg grating temperature sensors in plasma facing components of the WEST tokamak
Plasma Facing Components (PFC) temperature measurement is mandatory to ensure safe high power and long pulse tokamak operation. IR thermography systems which are widely used in magnetic fusions devices become challenged with the choice of tungsten as a PFC material in the ITER tokamak, mainly due to emissivity uncertainties and reflection issues in a hot environment. Embedded temperature measurements are foreseen to cross-check the IR thermography measurements. Fiber Bragg grating sensors are potentially of great interest for this application because they are immune to electromagnetic interference and allow the measurement of a large number of temperature spots on a single fiber. Four optical fiber temperature sensing probes, each of them including 11 regenerated fiber Bragg gratings equally spaced by 12.5 mm (equivalent to one ITER-like tungsten monoblock), have been specifically designed and manufactured for the WEST project (W-tungsten Environment and Steady State Tokamak). The four probes are embedded in W-coated graphite components at two different distances from the surface, 3.5 mm and 7 mm, to cover a wide range of temperatures up to 900 °C. This paper addresses the design and integration issues and the qualification and performance assessment performed in the laboratory. It also shows the first measurements of this new diagnostic achieved in a tokamak environment during baking of the machine and during early diverted plasma exposure.
- 13 April 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (14) , 145104
Thermal transport properties of multiphase sintered metals microstructures. The copper-tungsten system: Experiments and modeling
The thermal diffusivity of Cu-W sintered alloys microstructures is measured at room temperature at different compositions, using rear face flash experiments. The samples are synthesized with the Spark Plasma Sintering technique. The resulting microstructures are slightly porous and consist of angular nanoscale grains of tungsten with medium sphericity in a copper matrix. The tungsten particles are at the nanoscale with an average grain size of 250 nm in contrast to the copper matrix for which the average grain size lies in the range 20 μm–30 μm; this is large enough to avoid the grains boundary effect upon the thermal transport. The overall porosity of the microstructures lies within the range: . Along with the experimental work, a predictive model describing the effective thermal conductivity of multiphasic macrostructures is proposed in order to explain the obtained experimental results. The model was developed based only on physical considerations and contains no empirical parameters; it takes into account the type of microstructure and the microstructure parameters: porosity, grain shape, grain size, and grain size distribution. The agreement between the experiments and the model is found to be excellent.- 13 April 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (14) , 145104
Thermal transport properties of multiphase sintered metals microstructures. The copper-tungsten system: Experiments and modeling
The thermal diffusivity of Cu-W sintered alloys microstructures is measured at room temperature at different compositions, using rear face flash experiments. The samples are synthesized with the Spark Plasma Sintering technique. The resulting microstructures are slightly porous and consist of angular nanoscale grains of tungsten with medium sphericity in a copper matrix. The tungsten particles are at the nanoscale with an average grain size of 250 nm in contrast to the copper matrix for which the average grain size lies in the range 20 μm–30 μm; this is large enough to avoid the grains boundary effect upon the thermal transport. The overall porosity of the microstructures lies within the range: . Along with the experimental work, a predictive model describing the effective thermal conductivity of multiphasic macrostructures is proposed in order to explain the obtained experimental results. The model was developed based only on physical considerations and contains no empirical parameters; it takes into account the type of microstructure and the microstructure parameters: porosity, grain shape, grain size, and grain size distribution. The agreement between the experiments and the model is found to be excellent.