HEHasan H. Eroglu

Hasan H. Eroglu

*This is an algorithmically generated author record based on publicly available information.

Hasan H. Eroglu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Volumetric measurements of weak current–induced magnetic fields in the human brain at high resolution

    by Cihan Göksu, Fróði Gregersen, Klaus Scheffler, Hasan H. Eroğlu, Rahel Heule, Hartwig R. Siebner, Lars G. Hanson, Axel Thielscher

    Purpose: Clinical use of transcranial electrical stimulation (TES) requires accurate knowledge of the injected current distribution in the brain. MR current density imaging (MRCDI) uses measurements of the TES‐induced magnetic fields to provide this information. However, sufficient sensitivity and image quality in humans in vivo has only been documented for single‐slice imaging.Methods: A recently developed, optimally spoiled, acquisition‐weighted, gradient echo–based 2D‐MRCDI method has now been advanced for volume coverage with densely or sparsely distributed slices: The 3D rectilinear sampling (3D‐DENSE) and simultaneous multislice acquisition (SMS‐SPARSE) were optimized and verified by cable‐loop experiments and tested with 1‐mA TES experiments for two common electrode montages.Results: Comparisons between the volumetric methods against the 2D‐MRCDI showed that relatively long acquisition times of 3D‐DENSE using a single slab with six slices hindered the expected sensitivity improvement in the current‐induced field measurements but improved sensitivity by 61% in the Laplacian of the field, on which some MRCDI reconstruction methods rely. Also, SMS‐SPARSE acquisition of three slices, with a factor 2 CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration) acceleration, performed best against the 2D‐MRCDI with sensitivity improvements for the and Laplacian noise floors of 56% and 78% (baseline without current flow) as well as 43% and 55% (current injection into head). SMS‐SPARSE reached a sensitivity of 67 pT for three distant slices at 2 × 2 × 3 mm3 resolution in 10 min of total scan time, and consistently improved image quality.Conclusion: Volumetric MRCDI measurements with high sensitivity and image quality are well suited to characterize the TES field distribution in the human brain.


  • Open Access

    Sensitivity and resolution improvement for in vivo magnetic resonance current-density imaging of the human brain

    by Cihan Göksu, Klaus Scheffler, Fróði Gregersen, Hasan H. Eroğlu, Rahel Heule, Hartwig R. Siebner, Lars G. Hanson, Axel Thielscher

    Purpose: Magnetic resonance current‐density imaging (MRCDI) combines MRI with low‐intensity transcranial electrical stimulation (TES; 1‐2 mA) to map current flow in the brain. However, usage of MRCDI is still hampered by low measurement sensitivity and image quality.Methods: Recently, a multigradient‐echo–based MRCDI approach has been introduced that presently has the best‐documented efficiency. This MRCDI approach has now been advanced in three directions and has been validated by phantom and in vivo experiments. First, the importance of optimum spoiling for brain imaging was verified. Second, the sensitivity and spatial resolution were improved by using acquisition weighting. Third, navigators were added as a quality control measure for tracking physiological noise. Combining these advancements, the optimized MRCDI method was tested by using 1 mA TES for two different injection profiles.Results: For a session duration of 4:20 min, the new MRCDI method was able to detect TES‐induced magnetic fields at a sensitivity level of 84 picotesla, representing a twofold efficiency increase against our original method. A comparison between measurements and simulations based on personalized head models showed a consistent increase in the coefficient of determination of ΔR2= 0.12 for the current‐induced magnetic fields and ΔR2= 0.22 for the current flow reconstructions. Interestingly, some of the simulations still clearly deviated from the measurements despite the strongly improved measurement quality. This highlights the utility of MRCDI to improve head models for TES simulations.Conclusion: The achieved sensitivity improvement is an important step from proof‐of‐concept studies toward a broader application of MRCDI in clinical and basic neuroscience research.


  • Open Access

    On the Reconstruction of Magnetic Resonance Current Density Images of the Human Brain: Pitfalls and Perspectives

    by Hasan H. Eroğlu, Oula Puonti, Cihan Göksu, Fróði Gregersen, Hartwig R. Siebner, Lars G. Hanson, Axel Thielscher

    Magnetic resonance current density imaging (MRCDI) of the human brain aims to reconstruct the current density distribution caused by transcranial electric stimulation from MR-based measurements of the current-induced magnetic fields. The reconstruction problem is challenging due to a low signal-to-noise ratio and a limited volume coverage of the MR-based measurements, the lack of data from the scalp and skull regions and because MRCDI is only sensitive to the component of the current-induced magnetic field parallel to the scanner field. Most existing reconstruction approaches have been validated using simulation studies and measurements in phantoms with simplified geometries. Only one reconstruction method, the projected current density algorithm, has been applied to human in-vivo data so far, however resulting in blurred current density estimates even when applied to noise-free simulated data. We analyze the underlying causes for the limited performance of the projected current density algorithm when applied to human brain data. In addition, we compare it with an approach that relies on the optimization of the conductivities of a small number of tissue compartments of anatomically detailed head models reconstructed from structural MR data. Both for simulated ground truth data and human in-vivo MRCDI data, our results indicate that the estimation of current densities benefits more from using a personalized volume conductor model than from applying the projected current density algorithm. In particular, we introduce a hierarchical statistical testing approach as a principled way to test and compare the quality of reconstructed current density images that accounts for the limited signal-to-noise ratio of the human in-vivo MRCDI data and the fact that the ground truth of the current density is unknown for measured data. Our results indicate that the statistical testing approach constitutes a valuable framework for the further development of accurate volume conductor models of the head. Our findings also highlight the importance of tailoring the reconstruction approaches to the quality and specific properties of the available data.

  • Open Access

    Sensitivity and resolution improvement for in-vivo magnetic resonance current density imaging (MRCDI) of the human brain

    by Cihan Göksu, Klaus Scheffler, Fróði Gregersen, Hasan H. Eroğlu, Rahel Heule, Hartwig R. Siebner, Lars G. Hanson, Axel Thielscher

    Purpose: Magnetic resonance current density imaging (MRCDI) combines MR brain imaging with the injection of time-varying weak currents (1-2 mA) to assess the current flow pattern in the brain. However, the utility of MRCDI is still hampered by low measurement sensitivity and poor image quality. Methods: We recently introduced a multi-gradient-echo-based MRCDI approach that has the hitherto best documented efficiency. We now advanced our MRCDI approach in three directions and performed phantom and in-vivo human brain experiments for validation: First, we verified the importance of enhanced spoiling and optimize it for imaging of the human brain. Second, we improved the sensitivity and spatial resolution by using acquisition weighting. Third, we added navigators as a quality control measure for tracking physiological noise. Combining these advancements, we tested our optimized MRCDI method by using 1 mA transcranial electrical stimulation (TES) currents injected via two different electrode montages in five subjects. Results: For a session duration of 4:20 min, the new MRCDI method was able to detect magnetic field changes caused by the TES current flow at a sensitivity level of 84 pT, representing in a twofold increase relative to our original method. Comparing both methods to current flow simulations based on personalized head models demonstrated a consistent increase in the coefficient of determination of Δ R 2 =0.12 for the current-induced magnetic fields and Δ R 2 =0.22 for the current flow reconstructions. Interestingly, some of the simulations still clearly deviated from the measurements despite of the strongly improved measurement quality. This suggests that MRCDI can reveal useful information for the improvement of head models used for current flow simulations. Conclusion: The advanced method strongly improves the sensitivity and robustness of MRCDI and is an important step from proof-of-concept studies towards a broader application of MRCDI in clinical and basic neuroscience research.

  • Induced Current Magnetic Resonance Electrical Conductivity Imaging With Oscillating Gradients

    by Hasan H. Eroglu, Mehdi Sadighi, B. Murat Eyuboglu

    In this paper, induced current magnetic resonance electrical impedance tomography (ICMREIT) by means of current induction due to time-varying gradient fields of magnetic resonance imaging (MRI) systems is proposed. Eddy current and secondary magnetic flux density distributions are calculated for a numerical model composed of a z-gradient coil and a cylindrical conductor. An MRI pulse sequence is developed for the experimental evaluation of ICMREIT on a 3T MRI scanner. A relationship between the secondary magnetic flux density and the low-frequency (LF) MR phase is formulated. Characteristics of the LF phase, the eddy current, and the reconstructed conductivity distributions based on the simulated and the physical measurements are in agreement. Geometric shifts, which may contaminate the LF phase measurements, are not observed in the MR magnitude images. Low sensitivity of the LF phase measurements is a major limitation of ICMREIT towards clinical applications. The reconstructed conductivity images are rough estimates of true conductivity distribution of the experimental phantoms. Although the experimental results show that ICMREIT is safe and potentially applicable, its measurement sensitivity and reconstruction accuracy need to be optimized in order to improve the technique towards clinical applications.


  • Two alternatives for magnetic resonance electrical impedance tomography: injected or induced current

    by Hasan H Eroğlu, B Murat Eyüboğlu

    In this paper, the abilities of injected current magnetic resonance electrical impedance tomography (MREIT) and induced current magnetic resonance electrical impedance tomography (ICMREIT) systems to differentiate a conductivity perturbation from an otherwise uniform conductivity distribution are compared. The sensitivity of MREIT measurements changes as a function of distance to the electrodes used for current injection. The sensitivity of ICMREIT measurements is related to the radial location, being a minimum for concentrically located small conductivity perturbations. The very low sensitivity of ICMREIT to conductivity perturbations at central locations seems to be the major drawback of the method compared with MREIT. When the diameter of a concentric and/or an eccentric circular conductivity inhomogeneity inside an otherwise homogeneous circular conductor is close to half of the diameter of the conductor region, the distinguishability of the perturbation by MREIT increases. MREIT is more sensitive to perturbations with lower conductivity with respect to background conductivity (resistive perturbations) than to conductive perturbations. In the case of ICMREIT, concentric inhomogeneities are equally distinguishable for conductive and resistive conductivity perturbations. Eccentric resistive inhomogeneities are more distinguishable then conductive inhomogeneities. Distinguishability increases with the size and number of conductivity perturbations.