Xabier Justo
Research Subjects
Xabier Justo has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Iñaki Díaz
CEIT and Tecnun, University of Navarra, Paseo Manuel Lardizabal 15, 20018 San Sebastian, Spain
3 shared publications - Jorge Juan Gil
CEIT and TECNUN, University of Navarra, Paseo Manuel Lardizábal 15, E-20018 San Sebastián, Spain
3 shared publications - Gabriel Gastaminza
Department of Allergy and Clinical Immunology, Clinica Universidad de Navarra, Pamplona, Spain
2 shared publications - Axier Ugartemendia
Materials and Manufacturing Division, Ceit-Basque Research and Technology Alliance (BRTA), Paseo Manuel Lardizabal 15, 20018 San Sebastián, Spain
1 shared publication - Guzmán Domínguez-Domínguez
CEIT-Basque Research and Technology Alliance (BRTA), Donostia/San Sebastián, Spain
1 shared publication - Luis Matey
University of Navarra
1 shared publication
Latest Publications
- Open Access
- 10 February 2026
- Published by Elsevier in Mechatronics
- Vol. 116
Comparative analysis of harmonic drive and planetary gear actuation units for exoskeletons using load cell-based transparency control
- 10 February 2026
- Published by Elsevier in Mechatronics
- Vol. 116
Open AccessComparative analysis of harmonic drive and planetary gear actuation units for exoskeletons using load cell-based transparency control
- Open Access
- 26 May 2025
- Published by Asociación Española de Ingeniería Mecánica (AEIM) in Anales de Ingeniería Mecánica
- Vol. 1 (24)
Optimización topológica basada en curvas de nivel: metodología y aplicaciones.
El presente estudio presenta una metodología para la generación de estructuras ligeras a través de la optimización topológica basada en el método de las curvas de nivel (level-set methods, en inglés). Inicialmente, se lleva a cabo una revisión bibliográfica que aborda las características distintivas y la aplicabilidad de dichos métodos. Posteriormente, se detalla la estructura del algoritmo, se analizan los aspectos inherentes a su implementación y se evalúa el impacto de sus diversos parámetros en los resultados obtenidos. Por último, se extraen conclusiones acerca de los aspectos más relevantes en el desarrollo de algoritmos de optimización topológica basados en curvas de nivel, acompañadas de una serie de recomendaciones generales destinadas a potenciar la convergencia de dichos algoritmos.
- 26 May 2025
- Published by Asociación Española de Ingeniería Mecánica (AEIM) in Anales de Ingeniería Mecánica
- Vol. 1 (24)
Open AccessOptimización topológica basada en curvas de nivel: metodología y aplicaciones.
El presente estudio presenta una metodología para la generación de estructuras ligeras a través de la optimización topológica basada en el método de las curvas de nivel (level-set methods, en inglés). Inicialmente, se lleva a cabo una revisión bibliográfica que aborda las características distintivas y la aplicabilidad de dichos métodos. Posteriormente, se detalla la estructura del algoritmo, se analizan los aspectos inherentes a su implementación y se evalúa el impacto de sus diversos parámetros en los resultados obtenidos. Por último, se extraen conclusiones acerca de los aspectos más relevantes en el desarrollo de algoritmos de optimización topológica basados en curvas de nivel, acompañadas de una serie de recomendaciones generales destinadas a potenciar la convergencia de dichos algoritmos.
- 9 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (3) , 895-903
Medical Device for Automated Prick Test Reading
Allergy tests are routinely performed in most hospitals everyday. However, measuring the outcomes of these tests is still a very laborious manual task. Current methods and systems lack of precision and repeatability. This work presents a novel mechatronic system that is able to scan a patient’s entire arm and provide allergists with precise measures of wheals for diagnosis. The device is based on 3D laser technology and specific algorithms have been developed to process the information gathered. This system aims to automate the reading of skin prick tests and make gains in speed, accuracy and reliability. Several experiments have been performed to evaluate the performance of the system.
- 9 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (3) , 895-903
Medical Device for Automated Prick Test Reading
Allergy tests are routinely performed in most hospitals everyday. However, measuring the outcomes of these tests is still a very laborious manual task. Current methods and systems lack of precision and repeatability. This work presents a novel mechatronic system that is able to scan a patient’s entire arm and provide allergists with precise measures of wheals for diagnosis. The device is based on 3D laser technology and specific algorithms have been developed to process the information gathered. This system aims to automate the reading of skin prick tests and make gains in speed, accuracy and reliability. Several experiments have been performed to evaluate the performance of the system.
- Open Access
Prick test: evolution towards automated reading
The prick test is one of the most common medical methods for diagnosing allergies, and it has been carried out in a similar and laborious manner over many decades. In an attempt to standardize the reading of the test, many researchers have tried to automate the process of measuring the allergic reactions found by developing systems and algorithms based on multiple technologies. This work reviews the techniques for automatic wheal measurement with the aim of pointing out their advantages and disadvantages and the progress in the field. Furthermore, it provides a classification scheme for the different technologies applied. The works discussed herein provide evidence that significant challenges still exist for the development of an automatic wheal measurement system that not only helps allergists in their medical practice but also allows for the standardization of the reading and data exchange. As such, the aim of the work was to serve as guideline for the development of a proper and feasible system.
Open AccessPrick test: evolution towards automated reading
The prick test is one of the most common medical methods for diagnosing allergies, and it has been carried out in a similar and laborious manner over many decades. In an attempt to standardize the reading of the test, many researchers have tried to automate the process of measuring the allergic reactions found by developing systems and algorithms based on multiple technologies. This work reviews the techniques for automatic wheal measurement with the aim of pointing out their advantages and disadvantages and the progress in the field. Furthermore, it provides a classification scheme for the different technologies applied. The works discussed herein provide evidence that significant challenges still exist for the development of an automatic wheal measurement system that not only helps allergists in their medical practice but also allows for the standardization of the reading and data exchange. As such, the aim of the work was to serve as guideline for the development of a proper and feasible system.