Raphael Dorneles Caldeira Balboni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Raphael Dorneles Caldeira Balboni has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Camila Monteiro Cholant
Graduate Program in Materials Science and Engineering (PPGCEM), Federal University of Pelotas (UFPel), Pelotas 96010-610, RS, Brazil
3 shared publications - César Oropesa Avellaneda
Centro de Desenvolvimento Tecnológico, Universidade Federal de Pelotas, Pelotas, Brazil
3 shared publications - Neftali Lenin Villarreal Carreno
Graduate Program in Materials Science and Engineering (PPGCEM), Federal University of Pelotas (UFPel), Pelotas 96010-610, RS, Brazil
3 shared publications - André Gündel
Laboratory of Atomic Force Microscopy, Federal University of Pampa, Bagé 96413-170, Brazil
2 shared publications - Bruno Vasconcellos Lopes
Universidade Federal de Pelotas, Brazil
2 shared publications - Darci Alberto Gatto
Graduate Program in Materials Science and Engineering (PPGCEM), Federal University of Pelotas (UFPel), Pelotas 96010-610, RS, Brazil
2 shared publications
Latest Publications
- Open Access
- 14 June 2026
- Published by Elsevier in Chemical Engineering Science
- Vol. 335
Polarity-resolved fractions of eucalyptus-derived pyroligneous liquid for corrosion inhibition of AISI 1045 steel
- 14 June 2026
- Published by Elsevier in Chemical Engineering Science
- Vol. 335
Open AccessPolarity-resolved fractions of eucalyptus-derived pyroligneous liquid for corrosion inhibition of AISI 1045 steel
- 13 September 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 97
Study of the inhibitory effect of tetracycline hydrochloride on mild steel in HCl, HNO3, H2SO4 and NaCl solutions
- 13 September 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 97
Study of the inhibitory effect of tetracycline hydrochloride on mild steel in HCl, HNO3, H2SO4 and NaCl solutions
- Open Access
Electrochemical Biosensor Based on Laser-Induced Graphene for COVID-19 Diagnosing: Rapid and Low-Cost Detection of SARS-CoV-2 Biomarker Antibodies
The severe acute respiratory syndrome originated by the new coronavirus (SARS-CoV-2) that emerged in late 2019, known to be a highly transmissible and pathogenic disease, has caused the COVID-19 global pandemic outbreak. Thus, diagnostic devices that help epidemiological public safety measures to reduce undetected cases and isolation of infected patients, in addition to significantly help to control the population’s immune response to vaccine, are required. To address the negative issues of clinical research, we developed a Diagnostic on a Chip platform based on a disposable electrochemical biosensor containing laser-induced graphene and a protein (SARS-CoV-2 specific antigen) for the detection of SARS-CoV-2 antibodies. The biosensors were produced via direct laser writing using a CO2 infrared laser cutting machine on commercial polyimide sheets. The presence of specific antibodies reacting with the protein and the K3[Fe(CN)6] redox indicator produced characteristic and concentration-dependent electrochemical signals, with mean current values of 9.6757 and 8.1812 µA for reactive and non-reactive samples, respectively, proving the effectiveness of testing in clinical samples of serum from patients. Thus, the platform is being expanded to be measured in a portable microcontrolled potentiostat to be applied as a fast and reliable monitoring and mapping tool, aiming to assess the vaccinal immune response of the population.
Open AccessElectrochemical Biosensor Based on Laser-Induced Graphene for COVID-19 Diagnosing: Rapid and Low-Cost Detection of SARS-CoV-2 Biomarker Antibodies
The severe acute respiratory syndrome originated by the new coronavirus (SARS-CoV-2) that emerged in late 2019, known to be a highly transmissible and pathogenic disease, has caused the COVID-19 global pandemic outbreak. Thus, diagnostic devices that help epidemiological public safety measures to reduce undetected cases and isolation of infected patients, in addition to significantly help to control the population’s immune response to vaccine, are required. To address the negative issues of clinical research, we developed a Diagnostic on a Chip platform based on a disposable electrochemical biosensor containing laser-induced graphene and a protein (SARS-CoV-2 specific antigen) for the detection of SARS-CoV-2 antibodies. The biosensors were produced via direct laser writing using a CO2 infrared laser cutting machine on commercial polyimide sheets. The presence of specific antibodies reacting with the protein and the K3[Fe(CN)6] redox indicator produced characteristic and concentration-dependent electrochemical signals, with mean current values of 9.6757 and 8.1812 µA for reactive and non-reactive samples, respectively, proving the effectiveness of testing in clinical samples of serum from patients. Thus, the platform is being expanded to be measured in a portable microcontrolled potentiostat to be applied as a fast and reliable monitoring and mapping tool, aiming to assess the vaccinal immune response of the population.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Matéria (Rio de Janeiro)
- Vol. 25 (3)
Desempenho termoenergético e luminoso de uma edificação de escritório com a utilização de vidros eletrocrômicos
RESUMO Este trabalho tem como objetivo analisar o desempenho termoenergético e luminoso de uma edificação com atividades características de escritórios com vidros eletrocrômicos através de estudo comparativo, considerando vidros comuns de 3mm e 6mm. Para a simulação computacional foi utilizado o programa EnergyPlus . Foram realizadas simulações com o vidro comum Clear 3mm e de 6mm e o vidro eletrocrômico Sage Glass 9mm com a finalidade de analisar a iluminação, o consumo de energia, e o nível de conforto térmico provenientes da climatização artificial e da ventilação natural, respectivamente. As simulações foram realizadas em duas zonas bioclimáticas, na zona bioclimática 2 (ZB 2) e na zona bioclimática 8 (ZB 8), onde utilizou-se os arquivos climáticos da cidade de Camaquã e da cidade de Manaus, respectivamente. Com os resultados obtidos foi possível observar que a edificação com vidros eletrocrômicos apresentou melhor nível de conforto térmico nas horas ocupadas, e que o consumo de energia para resfriamento diminui conforme o aumento da coloração principalmente na ZB 8, por se tratar de uma região com clima quente. Notou-se que na ZB 2 em alguns meses do ano o vidro eletrocrômico permanecia totalmente descolorido, já que a temperatura de setpoint era sempre maior que a temperatura externa. Também foi possível observar que é fundamental analisar a orientação solar para o melhor posicionamento das aberturas na edificação.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Matéria (Rio de Janeiro)
- Vol. 25 (3)
Open AccessDesempenho termoenergético e luminoso de uma edificação de escritório com a utilização de vidros eletrocrômicos
RESUMO Este trabalho tem como objetivo analisar o desempenho termoenergético e luminoso de uma edificação com atividades características de escritórios com vidros eletrocrômicos através de estudo comparativo, considerando vidros comuns de 3mm e 6mm. Para a simulação computacional foi utilizado o programa EnergyPlus . Foram realizadas simulações com o vidro comum Clear 3mm e de 6mm e o vidro eletrocrômico Sage Glass 9mm com a finalidade de analisar a iluminação, o consumo de energia, e o nível de conforto térmico provenientes da climatização artificial e da ventilação natural, respectivamente. As simulações foram realizadas em duas zonas bioclimáticas, na zona bioclimática 2 (ZB 2) e na zona bioclimática 8 (ZB 8), onde utilizou-se os arquivos climáticos da cidade de Camaquã e da cidade de Manaus, respectivamente. Com os resultados obtidos foi possível observar que a edificação com vidros eletrocrômicos apresentou melhor nível de conforto térmico nas horas ocupadas, e que o consumo de energia para resfriamento diminui conforme o aumento da coloração principalmente na ZB 8, por se tratar de uma região com clima quente. Notou-se que na ZB 2 em alguns meses do ano o vidro eletrocrômico permanecia totalmente descolorido, já que a temperatura de setpoint era sempre maior que a temperatura externa. Também foi possível observar que é fundamental analisar a orientação solar para o melhor posicionamento das aberturas na edificação.
- 9 August 2018
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 29 (19) , 16911-16920
Electrochemical, UV–Vis, and microscopical characteristics of sol–gel CeO2:V2O5 thin film
- 9 August 2018
- Published by Springer Nature in Journal of Materials Science: Materials in Electronics
- Vol. 29 (19) , 16911-16920
Electrochemical, UV–Vis, and microscopical characteristics of sol–gel CeO2:V2O5 thin film