TTTaku Takaishi

Taku Takaishi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Taku Takaishi has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Akio Hiwatashi

    Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Kawasumi Mizuho-Cho, Nagoya, Japan

    4 shared publications
  • Tatsuya Kawai

    Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Kawasumi Mizuho-Cho, Nagoya, Japan

    3 shared publications
  • Sachiko Okochi

    Department of Radiology, Konan Kosei Hospital, Konan city, Japan

    2 shared publications
  • Shunsuke Shibata

    2 shared publications
  • Tatsuhito Yamamoto

    Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Kawasumi Mizuho-Cho, Nagoya, Japan

    2 shared publications
  • Yoshimasa Kokubo

    Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Kawasumi Mizuho-Cho, Nagoya, Japan

    2 shared publications

Latest Publications

  • Open Access

    Deep learning for appendicitis: development of a three-dimensional localization model on CT

    by Taku Takaishi, Tatsuya Kawai, Yoshimasa Kokubo, Takumi Fujinaga, Yoshinao Ojio, Tatsuhito Yamamoto, Kana Hayashi, Yusei Owatari, Hirotaka Ito, Akio Hiwatashi

    Purpose: To develop and evaluate a deep learning model for detecting appendicitis on abdominal CT. Materials and methods: This retrospective single-center study included 567 CTs of appendicitis patients (330 males, age range 20–96) obtained between 2011 and 2020, randomly split into training ( n = 517) and validation ( n = 50) sets. The validation set was supplemented with 50 control CTs performed for acute abdomen. For a test dataset, 100 appendicitis CTs and 100 control CTs were consecutively collected from a separate period after 2021. Exclusion criteria included age < 20, perforation, unclear appendix, and appendix tumors. Appendicitis CTs were annotated with three-dimensional bounding boxes that encompassed inflamed appendices. CT protocols were unenhanced, 5-mm slice-thickness, 512 × 512 pixel matrix. The deep learning algorithm was based on faster region convolutional neural network (Faster R-CNN). Two board-certified radiologists visually graded model predictions on the test dataset using a 5-point Likert scale (0: no detection, 1: false, 2: poor, 3: fair, 4: good), with scores ≥ 3 considered true positives. Inter-rater agreement was assessed using weighted kappa statistics. The effects of intra-abdominal fat, periappendiceal fat-stranding, presence of appendicolith, and appendix diameter on the model’s recall were analyzed using binary logistic regression. Results: The model showed a precision of 0.66 (87/132), a recall of 0.87 (87/100), and a false-positive rate per patient of 0.23 (45/200). The inter-rater agreement for Likert scores of 2–4 was κ = 0.76. The logistic regression analysis showed that only intra-abdominal fat had a significant impact on the model’s precision ( p = 0.02). Conclusion: We developed a model capable of detecting appendicitis on CT with a three-dimensional bounding box.


  • A quantitative SPECT/CT metric for diagnosing transthyretin cardiac amyloidosis: multicenter study on biopsy-confirmed cases

    by Taku Takaishi, Masaya Kisohara, Ryosuke Horino, Hitomi Kaneko, Naohide Hotta, Kyosuke Mizuno, Takamine Ezaka, Yuto Kitagawa, Sachiko Okochi, Susumu Kobayashi, et al.

    Purpose 99mTechnetium-pyrophosphate ([99mTc]Tc-PYP) scintigraphy is the gold standard for diagnosing transthyretin amyloid cardiomyopathy (ATTR-CM). Conventional metrics, such as heart-to-contralateral-chest (H/CL) ratio and visual Perugini score, can be influenced by physiological blood pool uptake, leading to false positives and additional patient burdens. This study aimed to develop and validate a simple quantitative metric widely applicable for ATTR-CM diagnosis. Methods This multicenter retrospective study enrolled 253 patients who underwent [99mTc]Tc-PYP SPECT/CT between April 2021 and September 2024. SPECT/CTs were acquired 3 h post-injection of 740 MBq [99mTc]Tc-PYP. A lateral wall-to-aorta (LW/Ao) ratio was obtained by dividing the average radiotracer count in the lateral wall of the left ventricle by the average count in the ascending aorta. The diagnosis of ATTR-CM diagnosis was determined by endomyocardial biopsy. As statistical analyses, area under receiver operating characteristic (AUC) was used to compare diagnostic accuracy, and intraclass correlation coefficient (ICC) was used to assess inter-rater agreement. Results Among 52 patients (31 men; mean age 77) whose biopsy results were available, 11 were diagnosed with ATTR-CM. LW/Ao ratio showed a sensitivity of 100% (11/11), specificity of 97.6% (40/41), and positive likelihood ratio of 41.0. LW/Ao ratio showed higher AUC (0.99; 95% CI: 0.99–1.00) compared to H/CL ratio (AUC = 0.90, p = 0.04) and visual score (AUC = 0.87, p < 0.01). The ICC of LW/Ao ratio was excellent (0.91 ≥ 0.9). Conclusion The quantitative SPECT/CT metric demonstrated superior diagnostic accuracy for ATTR-CM compared to conventional methods.


  • Open Access

    Automated detection and classification of adrenal masses on CT using two annotation methods: Segmentation vs. bounding box

    by Taku Takaishi, Yoshimasa Kokubo, Kurando Kondo, Kazuhisa Matsumoto, Tatsuhito Yamamoto, Shunsuke Shibata, Yusei Owatari, Fumito Nariyuki, Tatsuya Kawai, Akio Hiwatashi


  • Open Access

    Artificial intelligence deep learning software for segmentation of mediastinal and hilar lymph nodes on plain CT: a retrospective study in a cancer population

    by Taku Takaishi, Tatsuya Kawai, Megumi Kita, Shunsuke Shibata, Akio Hiwatashi

    Background: Accurate identification and characterization of lymph nodes (LNs) are essential in cancer staging and treatment planning. While artificial intelligence (AI) has shown potential in detecting lymphadenopathy on contrast-enhanced CT scans, its performance on non-contrast (plain) CT scans remains less explored. This retrospective study aimed to assess the efficacy of AI for segmenting LNs on plain CT in patients with lung or gastrointestinal cancer. Eligible cases were selected based on plain CT scans with 5 mm slice thickness, showing mediastinal or hilar LNs with a short-axis diameter of ≥ 10 mm. A total of 144 patients (105 men, 39 women; mean age, 76 years) were included, comprising 342 LNs. A commercially available deep learning AI software was used for segmentation, with the ground-truth defined by two radiologists’ consensus on LNs measuring ≥ 10 mm. Results: The AI software showed a sensitivity of 83.9%, with no statistically significant difference between mediastinal and hilar LNs (p = 0.84). The false-positive rate was 0.465 per patient. The Dice coefficient was 0.908, and there was no statistically significant difference between the mediastinum and hilum (p = 0.19). The sensitivity decreased in larger LNs, showing an inverse correlation (r = −0.122, p < 0.01). Conclusions: This study demonstrated the robustness of the AI software in the segmentation of LNs in the mediastinum and hilum on plain CT scans.


  • Incorporation of a computer-aided vessel-suppression system to detect lung nodules in CT images: effect on sensitivity and reading time in routine clinical settings

    by Taku Takaishi, Yoshiyuki Ozawa, Yuya Bando, Akiko Yamamoto, Sachiko Okochi, Hirochika Suzuki, Yuta Shibamoto

    Purpose To evaluate whether a computer-aided vessel-suppression system improves lung nodule detection in routine clinical settings. Materials and methods We used computer software that automatically suppresses pulmonary vessels on chest CT while preserving pulmonary nodules. Sixty-one chest CT images were included in our study. Three radiologists independently read either standard CT images alone or both computer-aided CT and standard CT images randomly to detect a pulmonary nodule ≥ 4 mm in diameter. After an interval of at least 15 days to avoid recall bias, the three radiologists interpreted the counterpart images of the same patients. The reference standard was decided by an expert panel. The primary endpoint was sensitivity. The secondary endpoint was interpretation time. Results The average sensitivity improved with computer-aided CT (72% for standard CT vs. 84% for computer-aided CT, p = 0.02). There was no difference in the false-positive rate (21% for both standard CT and computer-aided CT, p = 0.98). Although the average reading time was 9.5% longer for computer-aided plus standard CT compared with standard CT alone, the difference was not significant (p = 0.11). Conclusion Vessel-suppressed CT images helped radiologists to improve the sensitivity of pulmonary nodule detection without compromising the false-positive rate.