Chao Dai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chao Dai has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Ashish Paramane
Department of Electrical Engineering, National Institute of Technology Silchar, Silchar, India
11 shared publications - Xiangrong Chen
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
9 shared publications Yasuhiro Tanaka
Measurement and Electric Machine Control Laboratory, Tokyo City University, Tokyo, Japan
7 shared publicationsXiangrong Chen
5 shared publicationsAshish Paramane
Electrical Engineering Department National Institute of Technology Silchar India
4 shared publicationsGuangyu Zhu
4 shared publications
Latest Publications
- 7 February 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (7) , 3324-3333
Interfacial Engineering of Polydopamine-Coated Boron Nitride Nanoparticles for Enhanced Dielectric and Breakdown Performance in Epoxy Nanocomposites
- 7 February 2026
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 9 (7) , 3324-3333
Interfacial Engineering of Polydopamine-Coated Boron Nitride Nanoparticles for Enhanced Dielectric and Breakdown Performance in Epoxy Nanocomposites
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Energy Research
- Vol. 2026 (1) , 4600056
Heat Generation Characteristics of Lithium‐Ion Batteries for Grid‐Forming Energy Storage Under High Temperature Differences and High Discharge Rates
Grid‐forming energy storage system is often operated in environments with large temperature fluctuations and must meet both the requirements of conventional low‐rate scheduling and high‐rate grid support. These wide‐temperature‐range and multirate operating conditions can lead to changes in battery capacity degradation and heat generation mechanisms. This study developed a P2D electrochemical‐3D thermal coupling model for lithium‐ion batteries for grid‐forming energy storage system, distinguishing the physical parameters of the anode, cathode, and separator domains, and establishing separate heat sources for reversible heat, polarization heat, and Ohmic heat. After experimentally validating the model, the heat generation characteristics of the battery were analyzed under temperatures ranging from −15 to 45°C and discharge rates from 0.1 to 10 C. The results indicate that low temperatures significantly increase total heat generation and Ohmic heat in the separator; at high rates of discharge, polarization heat dominates, while reversible heat accounts for as much as 72% during discharge at 45°C and 0.1 C. In terms of spatial distribution, high rates of discharge cause extremely uneven internal heat generation, with the anode accounting for 66% of the heat generated. Furthermore, at −15°C and a 10 C discharge rate, the capacity dropped to 10% of that at room temperature; discharges at 6–10 C between 5 and 45°C all exceeded the 40°C safety threshold. These results reveal the heat generation and decay patterns under various operating conditions, providing a theoretical basis for evaluating extreme discharge capabilities and formulating thermal management strategies.
- 1 January 2026
- Published by Wiley in International Journal of Energy Research
- Vol. 2026 (1) , 4600056
Open AccessHeat Generation Characteristics of Lithium‐Ion Batteries for Grid‐Forming Energy Storage Under High Temperature Differences and High Discharge Rates
Grid‐forming energy storage system is often operated in environments with large temperature fluctuations and must meet both the requirements of conventional low‐rate scheduling and high‐rate grid support. These wide‐temperature‐range and multirate operating conditions can lead to changes in battery capacity degradation and heat generation mechanisms. This study developed a P2D electrochemical‐3D thermal coupling model for lithium‐ion batteries for grid‐forming energy storage system, distinguishing the physical parameters of the anode, cathode, and separator domains, and establishing separate heat sources for reversible heat, polarization heat, and Ohmic heat. After experimentally validating the model, the heat generation characteristics of the battery were analyzed under temperatures ranging from −15 to 45°C and discharge rates from 0.1 to 10 C. The results indicate that low temperatures significantly increase total heat generation and Ohmic heat in the separator; at high rates of discharge, polarization heat dominates, while reversible heat accounts for as much as 72% during discharge at 45°C and 0.1 C. In terms of spatial distribution, high rates of discharge cause extremely uneven internal heat generation, with the anode accounting for 66% of the heat generated. Furthermore, at −15°C and a 10 C discharge rate, the capacity dropped to 10% of that at room temperature; discharges at 6–10 C between 5 and 45°C all exceeded the 40°C safety threshold. These results reveal the heat generation and decay patterns under various operating conditions, providing a theoretical basis for evaluating extreme discharge capabilities and formulating thermal management strategies.
- Open Access
- 31 July 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 406, 04017
Research on the Influence of Valve Sensor Fault Based on Simulation
In the practical application of indoor air quality assurance system, it is difficult to detect the fault of air valves, CO2 sensors and other components, resulting in substandard air quality and increased energy consumption. In this paper, 16 fault conditions and 1 no fault condition were simulated by Simulink simulation software for primary return air conditioning system in summer, and a typical indoor air quality assurance system simulation fault characteristic table was obtained. It is found that PM2.5 sensor fault mainly affects indoor PM2.5 purification speed. The fault of a CO2 sensor affects indoor CO2 dilution and system energy consumption. Small resistance of return air valve increases system energy consumption. Small resistance of supply air valve, exhaust air valve and return air valve decreases the system's ability to control indoor pollutants.
- 31 July 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 406, 04017
Open AccessResearch on the Influence of Valve Sensor Fault Based on Simulation
In the practical application of indoor air quality assurance system, it is difficult to detect the fault of air valves, CO2 sensors and other components, resulting in substandard air quality and increased energy consumption. In this paper, 16 fault conditions and 1 no fault condition were simulated by Simulink simulation software for primary return air conditioning system in summer, and a typical indoor air quality assurance system simulation fault characteristic table was obtained. It is found that PM2.5 sensor fault mainly affects indoor PM2.5 purification speed. The fault of a CO2 sensor affects indoor CO2 dilution and system energy consumption. Small resistance of return air valve increases system energy consumption. Small resistance of supply air valve, exhaust air valve and return air valve decreases the system's ability to control indoor pollutants.
- 12 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (1) , 377-384
Remote Condition Monitoring of HVDC Cable Insulation Using Deep Learning-Aided Space Charge Classification
The homo-charges accumulated inside the polymeric insulation of high voltage dc (HVdc) cables increase the electrical field beyond the uniform value, whereas the hetero-charges reduce it. Such uneven electrical field distribution is detrimental to HVdc cables’ longevity and thus, needs to be identified accurately. To this end, this article proposes a deep learning (DL) framework for the automated detection of space charges in HVdc cable insulation. The space charges inside the cross-linked polyethylene (XLPE) insulation samples were measured under varying electric fields (10–50 kV/mm) as well as at different temperatures (30 °C–70 °C) conditions. The obtained space charge profiles corresponding to no charge, hetero-charge, and homo-charge categories were fed to two benchmark convolutional neural network (CNN) models, i.e., AlexNet and VGGNet16, for automated feature extraction and classification purpose. The convolutional blocks of the two CNN models were sequentially fine-tuned using transfer learning (TL) to observe the variation in classification accuracies. The proposed approach delivers appreciably high classification accuracies irrespective of varying electric field and temperature conditions with reduced computational time toward distinguishing different categories of space charge accumulations compared to other CNN models. Hence, it can be potentially used for real-time HVdc insulation diagnostic purposes.
- 12 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (1) , 377-384
Remote Condition Monitoring of HVDC Cable Insulation Using Deep Learning-Aided Space Charge Classification
The homo-charges accumulated inside the polymeric insulation of high voltage dc (HVdc) cables increase the electrical field beyond the uniform value, whereas the hetero-charges reduce it. Such uneven electrical field distribution is detrimental to HVdc cables’ longevity and thus, needs to be identified accurately. To this end, this article proposes a deep learning (DL) framework for the automated detection of space charges in HVdc cable insulation. The space charges inside the cross-linked polyethylene (XLPE) insulation samples were measured under varying electric fields (10–50 kV/mm) as well as at different temperatures (30 °C–70 °C) conditions. The obtained space charge profiles corresponding to no charge, hetero-charge, and homo-charge categories were fed to two benchmark convolutional neural network (CNN) models, i.e., AlexNet and VGGNet16, for automated feature extraction and classification purpose. The convolutional blocks of the two CNN models were sequentially fine-tuned using transfer learning (TL) to observe the variation in classification accuracies. The proposed approach delivers appreciably high classification accuracies irrespective of varying electric field and temperature conditions with reduced computational time toward distinguishing different categories of space charge accumulations compared to other CNN models. Hence, it can be potentially used for real-time HVdc insulation diagnostic purposes.
- 20 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (3) , 883-890
Investigation of Charge Accumulation and Decay Processes in Epoxy-Based Composites Using Quantum Chemical Calculations Under the Effect of Electric Field
This work investigates the influence of aluminum nitride (AlN) fillers on the charge dynamics of epoxy resin (EP) and its hybrid composites through space charge measurements and quantum chemical calculations (QCCs). QCCs analyze the energy-level orbitals and trap parameters of the molecules under the electric field. The pure EP exhibits a homo-charge accumulation, whereas fewer charges are accumulated in the EP hybrid composites. The AlN filler addition significantly suppresses the space charge accumulation during polarization and facilitates the charge dissipation during the depolarization due to the lower trap density than the pure EP. It is found that the orbital energy level of the combined reaction of all monomers together is not a simple superposition of individual orbital energy levels of different monomers. The increased charge injection barrier height suppresses space charge injection and accumulation. The electric field significantly influences the hole traps more than the electron traps. The positive charges with low mobility are easily trapped inside hole traps compared with the negative charges with high mobility inside the electron traps. This results in positive charge accumulation during the polarization and slow decay during the depolarization. The increase of the electrostatic potential is more uniform in hybrid composites than in the pure EP, and no visible electron migration is observed. It indicates that hybrid composites remain stable under electric fields. Moreover, it is not easy for the hole to transport due to the deep trap after the charge injection, leading to limited visible space charge accumulation near the anode.
- 20 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (3) , 883-890
Investigation of Charge Accumulation and Decay Processes in Epoxy-Based Composites Using Quantum Chemical Calculations Under the Effect of Electric Field
This work investigates the influence of aluminum nitride (AlN) fillers on the charge dynamics of epoxy resin (EP) and its hybrid composites through space charge measurements and quantum chemical calculations (QCCs). QCCs analyze the energy-level orbitals and trap parameters of the molecules under the electric field. The pure EP exhibits a homo-charge accumulation, whereas fewer charges are accumulated in the EP hybrid composites. The AlN filler addition significantly suppresses the space charge accumulation during polarization and facilitates the charge dissipation during the depolarization due to the lower trap density than the pure EP. It is found that the orbital energy level of the combined reaction of all monomers together is not a simple superposition of individual orbital energy levels of different monomers. The increased charge injection barrier height suppresses space charge injection and accumulation. The electric field significantly influences the hole traps more than the electron traps. The positive charges with low mobility are easily trapped inside hole traps compared with the negative charges with high mobility inside the electron traps. This results in positive charge accumulation during the polarization and slow decay during the depolarization. The increase of the electrostatic potential is more uniform in hybrid composites than in the pure EP, and no visible electron migration is observed. It indicates that hybrid composites remain stable under electric fields. Moreover, it is not easy for the hole to transport due to the deep trap after the charge injection, leading to limited visible space charge accumulation near the anode.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (1) , 137-144
Space-Charge Characteristics in Epoxy Composites Under Square Pulse Wave of Different Polarities With Various Frequencies at Various Temperatures
Space-charge characteristics of the pure epoxy resin (EP) and epoxy-based hybrid composites under square pulse waves of different polarities and frequencies at different temperatures are investigated. A specially built high-speed pulsed electro-acoustic (PEA) equipment for high-temperature testing is used. The square pulse of 40 kV/mm with different polarities and frequencies at 25 °C, 50 °C, and 80 °C, respectively, are adopted. The findings reveal that a negative electric field with a greater frequency and a positive electric field with a lower frequency can increase the space-charge accumulation. At low temperatures, there is no noticeable difference between the pure epoxy and micro-nano hybrid (MN) samples. The MN sample has fewer accumulated charges than the pure epoxy sample under the same electric field of different frequencies at different temperatures. At different temperatures, the electric field inside the pure epoxy sample distorts more severely than the MN sample, and such distortion increases with the temperature. On the other side, the electric field in the MN sample remains steady even at high temperatures. Negative electric fields have a more significant impact on average charge amounts than positive electric fields, especially at higher frequencies. A relevant mechanism is proposed to explain the results.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (1) , 137-144
Space-Charge Characteristics in Epoxy Composites Under Square Pulse Wave of Different Polarities With Various Frequencies at Various Temperatures
Space-charge characteristics of the pure epoxy resin (EP) and epoxy-based hybrid composites under square pulse waves of different polarities and frequencies at different temperatures are investigated. A specially built high-speed pulsed electro-acoustic (PEA) equipment for high-temperature testing is used. The square pulse of 40 kV/mm with different polarities and frequencies at 25 °C, 50 °C, and 80 °C, respectively, are adopted. The findings reveal that a negative electric field with a greater frequency and a positive electric field with a lower frequency can increase the space-charge accumulation. At low temperatures, there is no noticeable difference between the pure epoxy and micro-nano hybrid (MN) samples. The MN sample has fewer accumulated charges than the pure epoxy sample under the same electric field of different frequencies at different temperatures. At different temperatures, the electric field inside the pure epoxy sample distorts more severely than the MN sample, and such distortion increases with the temperature. On the other side, the electric field in the MN sample remains steady even at high temperatures. Negative electric fields have a more significant impact on average charge amounts than positive electric fields, especially at higher frequencies. A relevant mechanism is proposed to explain the results.
- 7 January 2022
- Published by IOP Publishing in Nanotechnology
- Vol. 33 (13) , 135705
Investigating optimal region for thermal and electrical properties of epoxy nanocomposites under high frequencies and temperatures
This research investigates the optimal region to achieve balanced thermal and electrical insulation properties of epoxy (EP) under high frequency (HF) and high temperature (HT) via integration of surface-modified hexagonal boron nitride (h-BN) nanoparticles. The effects of nanoparticle content and high temperature on various electrical (DC, AC, and high frequency) and thermal properties of EP are investigated. It is found that the nano h-BN addition enhances thermal performance and weakens electrical insulation properties. On the other side, under HF and HT stress, the presence of h-BN nanoparticles significantly improves the electrical performance of BN/EP nanocomposites. The EP has superior insulation properties at low temperature and low frequency, whereas the BN/EP nanocomposites exhibit better insulation performance than EP under HF and HT. The factors such as homogeneous nanoparticle dispersion in EP, enhanced thermal conductivity, nanoparticle surface modification, weight percent of nanoparticles, the mismatch between the relative permittivity of EP and nano h-BN, and the presence of voids in nanocomposites play the crucial role. The optimal nanoparticle content and homogenous dispersion can produce suitable EP composites for the high frequency and high temperature environment, particularly solid-state transformer applications.
- 7 January 2022
- Published by IOP Publishing in Nanotechnology
- Vol. 33 (13) , 135705
Investigating optimal region for thermal and electrical properties of epoxy nanocomposites under high frequencies and temperatures
This research investigates the optimal region to achieve balanced thermal and electrical insulation properties of epoxy (EP) under high frequency (HF) and high temperature (HT) via integration of surface-modified hexagonal boron nitride (h-BN) nanoparticles. The effects of nanoparticle content and high temperature on various electrical (DC, AC, and high frequency) and thermal properties of EP are investigated. It is found that the nano h-BN addition enhances thermal performance and weakens electrical insulation properties. On the other side, under HF and HT stress, the presence of h-BN nanoparticles significantly improves the electrical performance of BN/EP nanocomposites. The EP has superior insulation properties at low temperature and low frequency, whereas the BN/EP nanocomposites exhibit better insulation performance than EP under HF and HT. The factors such as homogeneous nanoparticle dispersion in EP, enhanced thermal conductivity, nanoparticle surface modification, weight percent of nanoparticles, the mismatch between the relative permittivity of EP and nano h-BN, and the presence of voids in nanocomposites play the crucial role. The optimal nanoparticle content and homogenous dispersion can produce suitable EP composites for the high frequency and high temperature environment, particularly solid-state transformer applications.