Alessandro Montanelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alessandro Montanelli has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Beatrice Feragalli
Department of Medical, Oral and Biotechnological Sciences, Radiology Unit, “G. D’Annunzio”, University of Chieti-Pescara, 66100 Chieti, Italy
2 shared publications - Fabrizio Urraro
Department of Life Sciences, Health and Health Professions, Link Campus University, 00165 Rome, Italy
2 shared publications - Gaetano Maria Russo
Department of Precision Medicine, University of Campania Luigi Vanvitelli, Naples, Italy
2 shared publications - Gianluigi Patelli
Department of Radiology, ASST Bergamo Est, 24068 Seriate, Italy
2 shared publications - Giuliana Giacobbe
General and Emergency Radiology Department, “Antonio Cardarelli” Hospital, 80131 Naples, Italy
2 shared publications - Maria Paola Belfiore
Department of Precision Medicine, University of Campania “L. Vanvitelli”, 80138 Naples, Italy
2 shared publications
Latest Publications
- Open Access
Coronavirus Disease 2019 (COVID-19) in Italy: Double Reading of Chest CT Examination
To assess the performance of the second reading of chest compute tomography (CT) examinations by expert radiologists in patients with discordance between the reverse transcription real-time fluorescence polymerase chain reaction (RT-PCR) test for COVID-19 viral pneumonia and the CT report. Three hundred and seventy-eight patients were included in this retrospective study (121 women and 257 men; 71 years median age, with a range of 29–93 years) and subjected to RT-PCR tests for suspicious COVID-19 infection. All patients were subjected to CT examination in order to evaluate the pulmonary disease involvement by COVID-19. CT images were reviewed first by two radiologists who identified COVID-19 typical CT patterns and then reanalyzed by another two radiologists using a CT structured report for COVID-19 diagnosis. Weighted k values were used to evaluate the inter-reader agreement. The median temporal window between RT-PCRs execution and CT scan was zero days with a range of (−9, 11) days. The RT-PCR test was positive in 328/378 (86.8%). Discordance between RT-PCR and CT findings for viral pneumonia was revealed in 60 cases. The second reading changed the CT diagnosis in 16/60 (26.7%) cases contributing to an increase the concordance with the RT-PCR. Among these 60 cases, eight were false negative with positive RT-PCR, and 36 were false positive with negative RT-PCR. Sensitivity, specificity, positive predictive value and negative predictive value of CT were respectively of 97.3%, 53.8%, 89.0%, and 88.4%. Double reading of CT scans and expert second readers could increase the diagnostic confidence of radiological interpretation in COVID-19 patients.
Open AccessCoronavirus Disease 2019 (COVID-19) in Italy: Double Reading of Chest CT Examination
To assess the performance of the second reading of chest compute tomography (CT) examinations by expert radiologists in patients with discordance between the reverse transcription real-time fluorescence polymerase chain reaction (RT-PCR) test for COVID-19 viral pneumonia and the CT report. Three hundred and seventy-eight patients were included in this retrospective study (121 women and 257 men; 71 years median age, with a range of 29–93 years) and subjected to RT-PCR tests for suspicious COVID-19 infection. All patients were subjected to CT examination in order to evaluate the pulmonary disease involvement by COVID-19. CT images were reviewed first by two radiologists who identified COVID-19 typical CT patterns and then reanalyzed by another two radiologists using a CT structured report for COVID-19 diagnosis. Weighted k values were used to evaluate the inter-reader agreement. The median temporal window between RT-PCRs execution and CT scan was zero days with a range of (−9, 11) days. The RT-PCR test was positive in 328/378 (86.8%). Discordance between RT-PCR and CT findings for viral pneumonia was revealed in 60 cases. The second reading changed the CT diagnosis in 16/60 (26.7%) cases contributing to an increase the concordance with the RT-PCR. Among these 60 cases, eight were false negative with positive RT-PCR, and 36 were false positive with negative RT-PCR. Sensitivity, specificity, positive predictive value and negative predictive value of CT were respectively of 97.3%, 53.8%, 89.0%, and 88.4%. Double reading of CT scans and expert second readers could increase the diagnostic confidence of radiological interpretation in COVID-19 patients.
- Open Access
- 22 September 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (18) , 6914
Chest CT Computerized Aided Quantification of PNEUMONIA Lesions in COVID-19 Infection: A Comparison among Three Commercial Software
Purpose: To compare different commercial software in the quantification of Pneumonia Lesions in COVID-19 infection and to stratify the patients based on the disease severity using on chest computed tomography (CT) images. Materials and methods: We retrospectively examined 162 patients with confirmed COVID-19 infection by reverse transcriptase-polymerase chain reaction (RT-PCR) test. All cases were evaluated separately by radiologists (visually) and by using three computer software programs: (1) Thoracic VCAR software, GE Healthcare, United States; (2) Myrian, Intrasense, France; (3) InferRead, InferVision Europe, Wiesbaden, Germany. The degree of lesions was visually scored by the radiologist using a score on 5 levels (none, mild, moderate, severe, and critic). The parameters obtained using the computer tools included healthy residual lung parenchyma, ground-glass opacity area, and consolidation volume. Intraclass coefficient (ICC), Spearman correlation analysis, and non-parametric tests were performed. Results: Thoracic VCAR software was not able to perform volumes segmentation in 26/162 (16.0%) cases, Myrian software in 12/162 (7.4%) patients while InferRead software in 61/162 (37.7%) patients. A great variability (ICC ranged for 0.17 to 0.51) was detected among the quantitative measurements of the residual healthy lung parenchyma volume, GGO, and consolidations volumes calculated by different computer tools. The overall radiological severity score was moderately correlated with the residual healthy lung parenchyma volume obtained by ThoracicVCAR or Myrian software, with the GGO area obtained by the ThoracicVCAR tool and with consolidation volume obtained by Myrian software. Quantified volumes by InferRead software had a low correlation with the overall radiological severity score. Conclusions: Computer-aided pneumonia quantification could be an easy and feasible way to stratify COVID-19 cases according to severity; however, a great variability among quantitative measurements provided by computer tools should be considered.
- 22 September 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (18) , 6914
Open AccessChest CT Computerized Aided Quantification of PNEUMONIA Lesions in COVID-19 Infection: A Comparison among Three Commercial Software
Purpose: To compare different commercial software in the quantification of Pneumonia Lesions in COVID-19 infection and to stratify the patients based on the disease severity using on chest computed tomography (CT) images. Materials and methods: We retrospectively examined 162 patients with confirmed COVID-19 infection by reverse transcriptase-polymerase chain reaction (RT-PCR) test. All cases were evaluated separately by radiologists (visually) and by using three computer software programs: (1) Thoracic VCAR software, GE Healthcare, United States; (2) Myrian, Intrasense, France; (3) InferRead, InferVision Europe, Wiesbaden, Germany. The degree of lesions was visually scored by the radiologist using a score on 5 levels (none, mild, moderate, severe, and critic). The parameters obtained using the computer tools included healthy residual lung parenchyma, ground-glass opacity area, and consolidation volume. Intraclass coefficient (ICC), Spearman correlation analysis, and non-parametric tests were performed. Results: Thoracic VCAR software was not able to perform volumes segmentation in 26/162 (16.0%) cases, Myrian software in 12/162 (7.4%) patients while InferRead software in 61/162 (37.7%) patients. A great variability (ICC ranged for 0.17 to 0.51) was detected among the quantitative measurements of the residual healthy lung parenchyma volume, GGO, and consolidations volumes calculated by different computer tools. The overall radiological severity score was moderately correlated with the residual healthy lung parenchyma volume obtained by ThoracicVCAR or Myrian software, with the GGO area obtained by the ThoracicVCAR tool and with consolidation volume obtained by Myrian software. Quantified volumes by InferRead software had a low correlation with the overall radiological severity score. Conclusions: Computer-aided pneumonia quantification could be an easy and feasible way to stratify COVID-19 cases according to severity; however, a great variability among quantitative measurements provided by computer tools should be considered.