LHLing He

Ling He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ling He has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Shilong Tang

    Children's Hospital, Chongqing Medical University, Chongqing, China

    11 shared publications
  • Lisha Nie

    GE Healthcare MR Research China Beijing China

    8 shared publications
  • Xianfan Liu

    Department of Radiology, Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Pediatrics, Chongqing, China

    8 shared publications
  • Fangfang Qian

    Department of Radiology Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Child Neurodevelopment and Cognitive Disorders, China

    4 shared publications
  • Zhuo Chen

    Department of Radiology, Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Pediatrics, Chongqing, China

    4 shared publications
  • Qiying Ran

    Department of Radiology, Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Pediatrics, Chongqing, China

    3 shared publications

Latest Publications

  • Open Access

    Study of Low kV, Low Contrast Agent Dosage, and Low Contrast Agent Flow Rate Scan in Computed Tomography Angiography of Children's Liver

    by Lan Wu, Shilong Tang, Wushuang Chen, Xin Chen, Li Zhang, Ling He

    Background: During computed tomography (CT) examinations, the presence of radiation material undoubtedly has a certain impact on patients, particularly children, who are more susceptible to radiation. Consequently, finding ways to minimize radiation dosage and mitigate radiation-related risks while enhancing the quality and accuracy of CT scans has become a crucial concern for medical professionals in CT equipment manufacturing companies and radiology departments to contemplate. Objectives: This study aimed to explore the feasibility of low dose and low contrast medium combined with low flow rate scanning in CT angiography (CTA) of children's liver. Patients and Methods: A total of 59 children who visited our department for liver vascular CT scans between April 2021 and December 2022 were prospectively selected and randomly divided into 2 groups: the experimental group and the control group. The experimental group consisted of 28 children who received an injection of 80 kV, automatic tube current, low contrast dose (1.5 mL/kg), and low flow rate of 20 s. The control group included 31 children who were injected with 100 kV, automatic tube current, contrast agent dose (2 mL/kg), and flow rate of 16 s. The objective and subjective image quality, radiation dose, and iodine intake in the arterial, portal, and venous phases were compared between the 2 groups. Results: During the arterial, portal, and venous phases, the experimental group exhibited lower signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) compared to the control group (P < 0.05). However, there was no significant difference in subjective quality scores between the 2 groups (P > 0.05). The effective dose (ED), volume CT dose index (CTDIvol), and dose-length product (DLP) of the experimental group were lower than those of the control group (P < 0.05). Additionally, the iodine intake in the experimental group was lower than that in the control group (P < 0.05). Conclusion: In the examination of hepatic vascular CTA in children, the use of a 3-low scanning technique can effectively decrease radiation and contrast agents while ensuring sufficient image quality for accurate clinical diagnosis.


  • Diffusion kurtosis imaging reveals abnormal gray matter and white matter development in some brain regions of children with attention‐deficit/hyperactivity disorder

    by Shilong Tang, Xianfan Liu, Lisha Nie, Fangfang Qian, Wushuang Chen, Ling He, Mei Yang

    In this study, we explored the application of diffusion kurtosis imaging (DKI) technology in the brains of children with attention‐deficit/hyperactivity disorder (ADHD). Seventy‐two children with ADHD and 79 age‐ and sex‐matched healthy controls were included in the study. All children were examined by means of 3D T1‐weighted image, DKI, and conventional sequence scanning. The volume and DKI parameters of each brain region were obtained by software postprocessing (GE ADW 4.6 workstation) and compared between the two groups of children to determine the imaging characteristics of children with ADHD. The result showed the total brain volume was lower in children with ADHD than in healthy children (p < .05). The gray and white matter volumes in the frontal lobe, temporal lobe, hippocampus, caudate nucleus, putamen, globus pallidus, and other brain regions were lower in children with ADHD than in healthy children (p < .05). The axial kurtosis (Ka), mean kurtosis (MK), fractional anisotropy (FA), and radial kurtosis(Kr) values in the frontal lobe, temporal lobe, and caudate nucleus of children with ADHD were lower than those of healthy children, while the mean diffusivity(MD) and fractional anisotropy of kurtosis (FAK) values were higher than those of healthy children (p < .05). Additionally, the Ka, MK, FA, and Kr values in the frontal lobe, caudate nucleus, and temporal lobe could be used to distinguish children with ADHD (AUC > .05, p < .05). In conclusion, DKI showed abnormal gray matter and white matter development in some brain regions of children with ADHD.


  • Open Access

    A Study of Fixed Current and Automatic Tube Current Modulation at a Fixed Low Tube Voltage in Low-dose Computed Tomography (CT) Imaging of Infant Lungs

    by Wushuang Chen, Shilong Tang, Zhen Xu, Xin Chen, Yinglan Zheng, Ling He

    Background: With the development of computed tomography (CT) technology, the number of infants undergoing CT examination has increased. Recently, problems associated with radiation exposure have attracted the public attention, and low-dose CT examination has become the research focus. Objectives: This study aimed to explore the feasibility of a fixed ultralow tube current combined with iDose4 iterative reconstruction at a low tube voltage (80 kV) in low-dose CT scanning of infant lungs. Patients and Methods: Ninety infants, aged 0 - 3 years, undergoing enhanced chest CT scan (including plain CT scan and arterial scan), were included in the experimental group. In the experimental group, plain CT scan was performed at 80 kV under a fixed tube current (30 mA), and arterial phase CT scan was carried out at 80 kV with automatic tube current modulation (30 - 150 mA). Meanwhile, 90 infants, aged 0 - 3 years, undergoing non-enhanced chest CT scan, were randomly recruited as the control group. For the control group, plain CT scan was performed at 80 kV with automatic tube current modulation (30-150 mA). In each examination, the iDose4 iterative reconstruction technique was used for reconstruction. The volume CT dose index (CTDIvol), dose-length product (DLP), effective dose (ED, measured using a 32-cm diameter phantom), signal-to-noise ratio (SNR), and overall subjective quality of plain CT scans were analyzed and compared between the experimental and control groups. Results: Regarding the radiation dose in different age groups, the ED (mSv) was significantly lower in the experimental group compared to the control group (0-1-year-old subgroup: 0.48 ± 0.05 mSv in the experimental group vs. 0.91 ± 0.19 mSv in the control group, P < 0.05; 1-2-year-old subgroup: 0.50 ± 0.01 mSv in the experimental group vs. 0.75 ± 0.10 mSv in the control group, P < 0.05; and 2-3-year-old subgroup: 0.46 ± 0.05 mSv in the experimental group vs. 0.79 ± 0.11 mSv in the control group, P < 0.05). The image SNR was higher in the control group compared to the experimental group (P < 0.05), while the difference in subjective image quality was not significant between the experimental and control groups (P < 0.05). Conclusion: The chest CT examination of infants, aged 0 - 3 years, at a low tube voltage (80 kV) and a fixed tube current (30 mA), combined with the iDose4 iterative reconstruction technique, and the obtained images met the diagnostic criteria...

  • Open Access

    Corrigendum: Three-dimensional pseudocontinuous arterial spin labeling perfusion imaging shows cerebral blood flow perfusion decline in attention-deficit/hyperactivity disorder children

    by Shilong Tang, Xianfan Liu, Lisha Nie, Fangfang Qian, Wushang Chen, Ling He

    Corrigendum: Three-dimensional pseudocontinuous arterial spin labeling perfusion imaging shows cerebral blood flow perfusion decline in attention-deficit/hyperactivity disorder children

  • Open Access

    Three-dimensional pseudocontinuous arterial spin labeling perfusion imaging shows cerebral blood flow perfusion decline in attention-deficit/hyperactivity disorder children

    by Shilong Tang, Xianfan Liu, Lisha Nie, Fangfang Qian, Wushang Chen, Ling He

    Purpose: To investigate the feasibility of three-dimensional pseudocontinuous arterial spin labeling (3D-pcASL) perfusion imaging in the brain of children with Attention-deficit/hyperactivity disorder (ADHD).Methods: A total of 78 ADHD children aged 5–13 years were prospectively selected as the study group, and 89 healthy children matched in age and sex were selected as the control group. All children underwent MRI conventional sequence, 3D-pcASL, and 3D-T1 sequence scans. The brain gray and white matter volume and cerebral blood flow (CBF) perfusion values were obtained by software post-processing, and were compared and analyzed in the two groups to find out their characteristics in the brain of ADHD children.Results: The total brain volume and total CBF values were lower in ADHD children than in healthy children (P < 0.05); the gray and white matter volumes in the frontal lobe, temporal lobe, hippocampus, caudate nucleus, putamen, globus pallidus and other brain regions were lower in ADHD children than in healthy children (P < 0.05); the gray matter CBF values in the frontal lobe, temporal lobe, hippocampus, caudate nucleus, putamen, globus pallidus and other brain regions were lower in ADHD children than in healthy children (P < 0.05); the differences between the white matter CBF values of white matter in the said brain regions of ADHD children and healthy children were not statistically significant (P > 0.05); and the CBF values in frontal lobe and caudate nuclei could distinguish ADHD children (AUC > 0.05, P < 0.05).Conclusion: The 3D-pcASL technique showed reduced cerebral perfusion in some brain regions of ADHD children.


  • Open Access

    Diagnosis of children with attention-deficit/hyperactivity disorder (ADHD) comorbid autistic traits (ATs) by applying quantitative magnetic resonance imaging techniques

    by Shilong Tang, Xianfan Liu, Lisha Nie, Zhuo Chen, Qiying Ran, Ling He

    Objective: To explore the feasibility of applying quantitative magnetic resonance imaging techniques for the diagnosis of children with attention-deficit/hyperactivity disorder (ADHD) comorbid autistic traits (ATs).Methods: A prospective study was performed by selecting 56 children aged 4–5 years with ADHD-ATs as the study group and 53 sex- and age-matched children with ADHD without ATs as the control group. All children underwent magnetic resonance scans with enhanced T2*- weighted magnetic resonance angiography (ESWAN), 3D-PCASL, and 3D-T1 sequences. Iron content and cerebral blood flow parameters were obtained via subsequent software processing, and the parameter values in particular brain regions in both groups were compared and analyzed to determine the characteristics of these parameters in children with ADHD-ATs.Results: Iron content and cerebral blood flow in the frontal lobe, temporal lobe, hippocampus, and caudate nucleus of children with ADHD-ATs were lower than those of children with ADHD without ATs (p < 0.05). Iron content and CBF values in the frontal lobe, temporal lobe and caudate nucleus could distinguish children with ADHD-ATs from those without ATs (AUC > 0.5, p < 0.05).Conclusions: Quantitative magnetic resonance techniques could distinguish children with ADHD-ATs.Trial registration: This study protocol was registered at the Chinese clinical trial registry (ChiCTR2100046616).


  • Application of Quantitative Susceptibility Mapping in the Assessment of Iron Content in Brain Regions of Normal Children

    by Ling He, Shilong Tang, Guanping Zhang, Xianfan Liu, Zhuo Chen

    Purpose: We evaluated brain iron content in a healthy pediatric population using quantitative susceptibility mapping (QSM). Methods: From June 2018 to December 2019, healthy subjects aged 2-18 years old (200 males, 200 females) with no anatomical abnormalities were assessed. All of the children underwent 3D T1 anatomical MRIs in addition to the sequence scans of enhanced T2 star-weighted angiography (ESWAN). The ESWAN sequence images were obtained with software to attain quantitative susceptibility mapping of the entire brain. The magnetic susceptibility values in the same brain region were compared across different age groups. The magnetic susceptibility values expressed in the same age group were compared across sexes, brain sides, and brain regions. Results: The magnetic susceptibility value of each brain region increased with age, and the magnetic susceptibility value expressed by each brain region demonstrated a positive correlation with the children’s age (r=0.63, P<0.05). No dramatic difference in magnetic susceptibility was observed between the brain’s left side and right side in the children within the age range ≥2-<6; however, among the children within the age range ≥6-<18, the magnetic susceptibility values expressed by the left putamen nucleus, globus pallidus, and substantia nigra were higher than those expressed by the same regions on the right side (P<0.05). Conclusion: Quantitative susceptibility mapping can be used to evaluate the content of iron in each brain region of normal children. Clinical Trial registration: This study protocol was registered at the Chinese clinical trial registry (ChiCTR2000030656).


  • Open Access

    Application of Quantitative Magnetic Resonance Imaging in the Diagnosis of Autism in Children

    by Shilong Tang, Lisha Nie, Xianfan Liu, Zhuo Chen, Yu Zhou, Zhengxia Pan, Ling He

    Objective: To explore the application of quantitative magnetic resonance imaging in the diagnosis of autism in children.Methods: Sixty autistic children aged 2–3 years and 60 age- and sex-matched healthy children participated in the study. All the children were scanned using head MRI conventional sequences, 3D-T1, diffusion kurtosis imaging (DKI), enhanced T2*- weighted magnetic resonance angiography (ESWAN) and 3D-pseudo continuous Arterial Spin-Labeled (3D-pcASL) sequences. The quantitative susceptibility mapping (QSM), cerebral blood flow (CBF), and brain microstructure of each brain area were compared between the groups, and correlations were analyzed.Results: The iron content and cerebral blood flow in the frontal lobe, temporal lobe, hippocampus, caudate nucleus, substantia nigra, and red nucleus of the study group were lower than those in the corresponding brain areas of the control group (P < 0.05). The mean kurtosis (MK), radial kurtosis (RK), and axial kurtosis (AK) values of the frontal lobe, temporal lobe, putamen, hippocampus, caudate nucleus, substantia nigra, and red nucleus in the study group were lower than those of the corresponding brain areas in the control group (P < 0.05). The mean diffusivity (MD) and fractional anisotropy of kurtosis (FAK) values of the frontal lobe, temporal lobe and hippocampus in the control group were lower than those in the corresponding brain areas in the study group (P < 0.05). The values of CBF, QSM, and DKI in frontal lobe, temporal lobe and hippocampus could distinguish ASD children (AUC > 0.5, P < 0.05), among which multimodal technology (QSM, CBF, DKI) had the highest AUC (0.917) and DKI had the lowest AUC (0.642).Conclusion: Quantitative magnetic resonance imaging (including QSM, 3D-pcASL, and DKI) can detect abnormalities in the iron content, cerebral blood flow and brain microstructure in young autistic children, multimodal technology (QSM, CBF, DKI) could be considered as the first choice of imaging diagnostic technology.Clinical Trial Registration: [http://www.chictr.org.cn/searchprojen.aspx], identifier [ChiCTR2000029699].


  • Open Access

    Application of Three-Dimensional Pseudocontinuous Arterial Spin Labeling Perfusion Imaging in the Brains of Children With Autism

    by Shilong Tang, Xianfan Liu, Qiying Ran, Lisha Nie, Lan Wu, Zhengxia Pan, Ling He

    Objective: To explore the application of three-dimensional pseudocontinuous arterial spin labeling (3D-PCASL) perfusion imaging in the brains of children with autism and to understand the characteristics of cerebral blood perfusion in children with autism.Methods: A total of 320 children with autism (160 men and 160 women) aged between 2 and 18 years and 320 age- and sex-matched healthy children participated in the study. All children were scanned by 3.0 T magnetic resonance axial T1 fluid-attenuated inversion recovery (FLAIR), T2 FLAIR, 3D-T1, and 3D-PCASL sequences. After postprocessing, cerebral blood flow (CBF) values in each brain region of children with autism and healthy children at the same age were compared and analyzed. Furthermore, CBF characteristics in each brain region of autistic children at various ages were determined.Results: The CBF values of the frontal lobe, hippocampus, temporal lobe, and caudate nucleus of children with autism are lower than those of healthy children (P < 0.05). Additionally, as the ages of children with autism increase, the number of brain regions with decreased CBF values gradually increases. A receiver operating characteristic (ROC) analysis results show that the CBF values of the frontal lobe, hippocampus, temporal lobe, and caudate nucleus can distinguish children with autism [area under the ROC curve (AUC) > 0.05, P < 0.05].Conclusion: The 3D-PCASL shows lower brain CBF values in children with autism.Clinical Trial Registration: www.ClinicalTrials.gov, identifier: ChiCTR2000034356.