Kevin McDonald
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kevin McDonald has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Tommaso Ranzani
Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA
8 shared publications Abigail Rendos
Division of Materials Science and Engineering Boston University Boston MA 02215 USA
3 shared publications- Keith A. Brown
Boston University
3 shared publications - Lorenzo Kinnicutt
Department of Mechanical Engineering Boston University Boston MA 02215 USA
3 shared publications Stephanie Woodman
Department of Mechanical Engineering Boston University Boston MA 02215 USA
3 shared publicationsZi Heng Lim
3 shared publications
Latest Publications
- Open Access
- 26 June 2023
- Published by The Hamlyn Centre for Robotic Surgery
- p. 101-102
A Soft Laparoscopic Grasper for Retraction of the Small Intestine
Laparoscopy can improve outcomes and patient re- covery times compared to open surgery. However, the minimally-invasive nature of these procedures deprives clinicians of tactile feedback which, when coupled with pinching graspers that deliver high-stress concentrations, increases the likelihood of inflicting iatrogenic trauma upon tissues, especially the small intestine [1]–[4]. Retraction of the small intestine is often necessary to vi- sualize and access nearby tissues [5], [6]. Commercially- available devices rely on passive structures to hold intestinal segments and do not embed compliance [7]. Prior research on surgical retractors has focused on granular jamming [5], pneumatic balloons [6], and either cable-driven [8] or vacuum [9] graspers. However, these devices are challenging to integrate into surgical work- flows, require auxiliary instruments, and do not provide feedback regarding tissue interaction forces. We introduce a laparoscopic grasper capable of passing through an 18 mm trocar, expanding to a controllable width once inside the abdominal cavity, and safely enveloping the small intestine to enable retraction. Upon entry into the abdominal cavity, the grasper estab- lishes an initial hold on a target intestinal segment by pulling vacuum through the suction unit on its distal tip (Fig. 1[a]); this functionality helps the surgeon isolate the target intestinal segment from surrounding bundles. Once a preliminary suction hold has been established, the grasper envelops the intestine by inflating a pair of pneumatic fiber-reinforced soft actuators (FRSAs) (Fig. 1[b]-[c]), whose separation can be modulated up to 40 mm using a miniaturized scissor lift mechanism (MSLM). This approach distributes the force necessary to grasp and hold the intestine over a large surface area (i.e., the whole surface of the FRSAs) rather than concentrating it in a small region, allowing safe, robust grasps even on dilated intestinal segments. Inflation of the FRSAs and suction are controlled using two buttons (Fig. 1 [d]). The horizontal position of the FRSAs and the separation between them are independently actuated via two linear motors, which the surgeon controls using a rocker switch and trigger, respectively (Fig. 1 [d]). Each actuator is equipped with two soft sensors to interpret 3D interaction forces via a machine learning algorithm.
- 26 June 2023
- Published by The Hamlyn Centre for Robotic Surgery
- p. 101-102
Open AccessA Soft Laparoscopic Grasper for Retraction of the Small Intestine
Laparoscopy can improve outcomes and patient re- covery times compared to open surgery. However, the minimally-invasive nature of these procedures deprives clinicians of tactile feedback which, when coupled with pinching graspers that deliver high-stress concentrations, increases the likelihood of inflicting iatrogenic trauma upon tissues, especially the small intestine [1]–[4]. Retraction of the small intestine is often necessary to vi- sualize and access nearby tissues [5], [6]. Commercially- available devices rely on passive structures to hold intestinal segments and do not embed compliance [7]. Prior research on surgical retractors has focused on granular jamming [5], pneumatic balloons [6], and either cable-driven [8] or vacuum [9] graspers. However, these devices are challenging to integrate into surgical work- flows, require auxiliary instruments, and do not provide feedback regarding tissue interaction forces. We introduce a laparoscopic grasper capable of passing through an 18 mm trocar, expanding to a controllable width once inside the abdominal cavity, and safely enveloping the small intestine to enable retraction. Upon entry into the abdominal cavity, the grasper estab- lishes an initial hold on a target intestinal segment by pulling vacuum through the suction unit on its distal tip (Fig. 1[a]); this functionality helps the surgeon isolate the target intestinal segment from surrounding bundles. Once a preliminary suction hold has been established, the grasper envelops the intestine by inflating a pair of pneumatic fiber-reinforced soft actuators (FRSAs) (Fig. 1[b]-[c]), whose separation can be modulated up to 40 mm using a miniaturized scissor lift mechanism (MSLM). This approach distributes the force necessary to grasp and hold the intestine over a large surface area (i.e., the whole surface of the FRSAs) rather than concentrating it in a small region, allowing safe, robust grasps even on dilated intestinal segments. Inflation of the FRSAs and suction are controlled using two buttons (Fig. 1 [d]). The horizontal position of the FRSAs and the separation between them are independently actuated via two linear motors, which the surgeon controls using a rocker switch and trigger, respectively (Fig. 1 [d]). Each actuator is equipped with two soft sensors to interpret 3D interaction forces via a machine learning algorithm.
- Open Access
- 17 March 2023
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 19 (14) , 2623-2636
Magnetically induced stiffening for soft robotics
Soft robots are well-suited for human-centric applications, but the compliance that gives soft robots this advantage must also be paired with adequate stiffness modulation such that soft robots can achieve more rigidity when needed. For this reason, variable stiffening mechanisms are often a necessary component of soft robot design. Many techniques have been explored to introduce variable stiffness structures into soft robots, such as pneumatically-controlled jamming and thermally-controlled phase change materials. Despite fast response time, jamming methods often require a bulkier pneumatic pressure line which limits portability; and while portable via electronic control, thermally-induced methods require compatibility with high temperatures and often suffer from slow response time. In this paper, we present a magnetically-controlled stiffening approach that combines jamming-based stiffening principles with magnetorheological fluid to create a hybrid mechanical and materials approach. In doing so, we combine the advantages of fast response time from pneumatically-based jamming with the portability of thermally-induced phase change methods. We explore the influence of magnetic field strength on the stiffening of our magnetorheological jamming beam samples in two ways: by exploiting the increase in yield stress of magnetorheological fluid, and by additionally using the clamping force between permanent magnets to further stiffen the samples via a clutch effect. We introduce an analytical model to predict the stiffness of our samples as a function of the magnetic field. Finally, we demonstrate electronic control of the stiffness using electropermanent magnets. In this way, we present an important step towards a new electronically-driven stiffening mechanism for soft robots that interact safely in close contact with humans, such as in wearable devices.
- 17 March 2023
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 19 (14) , 2623-2636
Open AccessMagnetically induced stiffening for soft robotics
Soft robots are well-suited for human-centric applications, but the compliance that gives soft robots this advantage must also be paired with adequate stiffness modulation such that soft robots can achieve more rigidity when needed. For this reason, variable stiffening mechanisms are often a necessary component of soft robot design. Many techniques have been explored to introduce variable stiffness structures into soft robots, such as pneumatically-controlled jamming and thermally-controlled phase change materials. Despite fast response time, jamming methods often require a bulkier pneumatic pressure line which limits portability; and while portable via electronic control, thermally-induced methods require compatibility with high temperatures and often suffer from slow response time. In this paper, we present a magnetically-controlled stiffening approach that combines jamming-based stiffening principles with magnetorheological fluid to create a hybrid mechanical and materials approach. In doing so, we combine the advantages of fast response time from pneumatically-based jamming with the portability of thermally-induced phase change methods. We explore the influence of magnetic field strength on the stiffening of our magnetorheological jamming beam samples in two ways: by exploiting the increase in yield stress of magnetorheological fluid, and by additionally using the clamping force between permanent magnets to further stiffen the samples via a clutch effect. We introduce an analytical model to predict the stiffness of our samples as a function of the magnetic field. Finally, we demonstrate electronic control of the stiffness using electropermanent magnets. In this way, we present an important step towards a new electronically-driven stiffening mechanism for soft robots that interact safely in close contact with humans, such as in wearable devices.
- Open Access
- 20 October 2022
- Published by Wiley in Advanced Intelligent Systems
- Vol. 4 (10)
A Collapsible Soft Actuator Facilitates Performance in Constrained Environments
- 20 October 2022
- Published by Wiley in Advanced Intelligent Systems
- Vol. 4 (10)
Open AccessA Collapsible Soft Actuator Facilitates Performance in Constrained Environments
- Open Access
- 26 June 2022
- Published by Wiley in Advanced Intelligent Systems
- Vol. 4 (10)
A Collapsible Soft Actuator Facilitates Performance in Constrained Environments
Complex environments, such as those found in surgical and search‐and‐rescue applications, require soft devices to adapt to minimal space conditions without sacrificing the ability to complete dexterous tasks. Stacked balloon actuators (SBAs) are capable of large deformations despite folding nearly flat when deflated, making them ideal candidates for such applications. This paper presents the design, fabrication, modeling, and characterization of monolithic, inflatable, soft SBAs. Modeling is presented using analytical principles based on geometry and then using conventional and real‐time finite‐element methods. Both one and three degree‐of‐freedom (DoF) SBAs are fully characterized with regard to stroke, force, and workspace. Finally, three representative demonstrations show the SBA's small‐aperture navigation, bracing, and workspace‐enhancing capabilities.
- 26 June 2022
- Published by Wiley in Advanced Intelligent Systems
- Vol. 4 (10)
Open AccessA Collapsible Soft Actuator Facilitates Performance in Constrained Environments
Complex environments, such as those found in surgical and search‐and‐rescue applications, require soft devices to adapt to minimal space conditions without sacrificing the ability to complete dexterous tasks. Stacked balloon actuators (SBAs) are capable of large deformations despite folding nearly flat when deflated, making them ideal candidates for such applications. This paper presents the design, fabrication, modeling, and characterization of monolithic, inflatable, soft SBAs. Modeling is presented using analytical principles based on geometry and then using conventional and real‐time finite‐element methods. Both one and three degree‐of‐freedom (DoF) SBAs are fully characterized with regard to stroke, force, and workspace. Finally, three representative demonstrations show the SBA's small‐aperture navigation, bracing, and workspace‐enhancing capabilities.
- 1 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 3914-3921
Modulation of Magnetorheological Fluid Flow in Soft Robots Using Electropermanent Magnets
Magnetorheological (MR) fluids, which stiffen in the presence of magnetic fields, have been shown to be an effective means for controlling the inflation of soft actuators. However, past efforts have largely focused on binary control. Proportional control schemes have faltered due to the difficulty in producing sufficient magnetic fields without requiring large amounts of electrical power. Electropermanent magnets (EPMs) offer one solution to this issue, since they can produce magnetic fields which are similar in magnitude to permanent magnets, they can be controlled electrically, but they do not require any power to hold their state. In this letter, we use EPMs to control the material properties of an MR fluid, allowing us to modulate the pressure within soft actuators. We demonstrate and quantify this behavior for several classes of soft actuators via bending and blocked force testing. We then demonstrate the ability to independently control the actuation of multiple-DoFs systems operating in both a binary and fully-modulated manner, thus providing an important step towards the development of reprogrammable, autonomous soft robots.
- 1 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 3914-3921
Modulation of Magnetorheological Fluid Flow in Soft Robots Using Electropermanent Magnets
Magnetorheological (MR) fluids, which stiffen in the presence of magnetic fields, have been shown to be an effective means for controlling the inflation of soft actuators. However, past efforts have largely focused on binary control. Proportional control schemes have faltered due to the difficulty in producing sufficient magnetic fields without requiring large amounts of electrical power. Electropermanent magnets (EPMs) offer one solution to this issue, since they can produce magnetic fields which are similar in magnitude to permanent magnets, they can be controlled electrically, but they do not require any power to hold their state. In this letter, we use EPMs to control the material properties of an MR fluid, allowing us to modulate the pressure within soft actuators. We demonstrate and quantify this behavior for several classes of soft actuators via bending and blocked force testing. We then demonstrate the ability to independently control the actuation of multiple-DoFs systems operating in both a binary and fully-modulated manner, thus providing an important step towards the development of reprogrammable, autonomous soft robots.
- Open Access
- 23 November 2020
- Published by Wiley in Advanced Intelligent Systems
- Vol. 2 (11)
Magnetorheological Fluid‐Based Flow Control for Soft Robots
- 23 November 2020
- Published by Wiley in Advanced Intelligent Systems
- Vol. 2 (11)
Open AccessMagnetorheological Fluid‐Based Flow Control for Soft Robots
- Open Access
- 18 September 2020
- Published by Wiley in Advanced Intelligent Systems
- Vol. 2 (11)
Magnetorheological Fluid‐Based Flow Control for Soft Robots
Fluidic soft robots bring a high degree of dexterity and adaptability to robotics problems requiring safe interactions with complex structures. While they are low cost and easy to manufacture, they are difficult to control due to their typical reliance on external pressure sources that become bulky as more degrees of freedom are introduced to the robot. Various techniques from microfluidics and fluid logic are used to introduce valves into soft robots to increase their autonomy, although this has frequently introduced unwanted rigidity. Herein, a magnetorheological (MR) fluid valve that uses magnetic fields to control the pressure within a continuous‐flow fluidic actuator is introduced. A predictive model for the pressure drop in such a flow is presented and validated experimentally. Guidelines for the design of single‐ and multiactuator systems with a single inlet and outlet are presented. The introduction of actuation methods that simplify fluidic control via the application of magnetic fields leads to robots capable of increased autonomy in a scalable and compliant format.
- 18 September 2020
- Published by Wiley in Advanced Intelligent Systems
- Vol. 2 (11)
Open AccessMagnetorheological Fluid‐Based Flow Control for Soft Robots
Fluidic soft robots bring a high degree of dexterity and adaptability to robotics problems requiring safe interactions with complex structures. While they are low cost and easy to manufacture, they are difficult to control due to their typical reliance on external pressure sources that become bulky as more degrees of freedom are introduced to the robot. Various techniques from microfluidics and fluid logic are used to introduce valves into soft robots to increase their autonomy, although this has frequently introduced unwanted rigidity. Herein, a magnetorheological (MR) fluid valve that uses magnetic fields to control the pressure within a continuous‐flow fluidic actuator is introduced. A predictive model for the pressure drop in such a flow is presented and validated experimentally. Guidelines for the design of single‐ and multiactuator systems with a single inlet and outlet are presented. The introduction of actuation methods that simplify fluidic control via the application of magnetic fields leads to robots capable of increased autonomy in a scalable and compliant format.
- 2 June 2020
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 29 (7) , 07LT02
Shear thickening prevents slip in magnetorheological fluids
Magnetorheological (MR) fluids are smart fluids that solidify upon the application of a magnetic field by virtue of suspended magnetic particles forming chains. Here, the effect of shear thickening additives on the performance of MR fluids is explored and found to increase yield stress by 60% in fluids that have the same iron content. In order to explore the origin of this improvement, a series of flow- and oscillation-based rheology experiments were performed at various plate separations and the results were compared with a discrete dipole model of chain formation and breakage. Ultimately, conventional MR fluids, which are typically shear thinning, are found to yield at small strains that are consistent with slip failure where chains shear apart at one particle-particle joint. In contrast, shear thickening fluids reliably yield at high strain in a manner consistent with affine failure of the chain where each joint is pulled apart equally. The prevention of slip failure is attributed to the shear thickening additive locally increasing the effective viscosity as slip begins, thus preventing it from leading to yield. In addition to motivating the use of shear thickening agents broadly in MR fluids, these findings highlight the importance of additive choice in tuning rheological properties of MR fluids and the benefit of considering the microstructural and bulk behavior of the fluid simultaneously when synthesizing smart fluids.
- 2 June 2020
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 29 (7) , 07LT02
Shear thickening prevents slip in magnetorheological fluids
Magnetorheological (MR) fluids are smart fluids that solidify upon the application of a magnetic field by virtue of suspended magnetic particles forming chains. Here, the effect of shear thickening additives on the performance of MR fluids is explored and found to increase yield stress by 60% in fluids that have the same iron content. In order to explore the origin of this improvement, a series of flow- and oscillation-based rheology experiments were performed at various plate separations and the results were compared with a discrete dipole model of chain formation and breakage. Ultimately, conventional MR fluids, which are typically shear thinning, are found to yield at small strains that are consistent with slip failure where chains shear apart at one particle-particle joint. In contrast, shear thickening fluids reliably yield at high strain in a manner consistent with affine failure of the chain where each joint is pulled apart equally. The prevention of slip failure is attributed to the shear thickening additive locally increasing the effective viscosity as slip begins, thus preventing it from leading to yield. In addition to motivating the use of shear thickening agents broadly in MR fluids, these findings highlight the importance of additive choice in tuning rheological properties of MR fluids and the benefit of considering the microstructural and bulk behavior of the fluid simultaneously when synthesizing smart fluids.