QLQingyu Lv

Qingyu Lv

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Qingyu Lv has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a Rapid and Sensitive AlphaLISA-Based Assay for Lassa Virus Glycoprotein Detection

    by Hao Cai, Qingyu Lv, Wenhua Huang, Shaolong Chen, Peng Liu, Hua Jiang, Qian Li, Decong Kong, Yuhao Ren, Zhongpeng Zhao, et al.

    Lassa virus (LASV), a member of the Arenaviridae family, is the causative agent of Lassa fever (LF), an acute zoonotic hemorrhagic disease transmitted by rodents, characterized by high infectivity and mortality rates. Due to the nonspecific nature of early clinical symptoms, the development of rapid, sensitive, and specific diagnostic methods is critical for effective epidemic control. In this study, the Lassa virus glycoprotein complex (LASV-G) was selected as the target antigen. High-affinity rabbit monoclonal antibodies were generated using a single B-cell cloning approach, and an AlphaLISA (Amplified Luminescent Proximity Homogeneous Assay)-based homogeneous, no-wash detection system was established. Sixteen LASV-G-specific monoclonal antibodies were isolated through flow cytometric sorting, and the optimal antibody pair (56–24) was identified by AlphaLISA pairing and performance screening. The established AlphaLISA system exhibited a limit of detection (LOD) of 0.025 ng/mL, representing approximately a 30-fold increase in sensitivity compared with conventional Enzyme Linked Immunosorbent Assay (ELISA), while reducing the total assay time to less than 30 min. The coefficient of variation (CV) was below 8%, and no cross-reactivity was observed with Ebola, dengue, yellow fever, Zika, or influenza virus antigens. These findings demonstrate that the developed AlphaLISA assay possesses high sensitivity, rapid detection, and good tolerance to matrix effects, significantly improving the efficiency of early LASV antigen detection. This work provides a potential platform for the rapid on-site screening and epidemiological surveillance of highly pathogenic viruses.

  • Open Access

    A Highly Specific Antibody-Based Assay for Nipah Virus AlphaLISA Detection

    by Xuyang Sun, Qingyu Lv, Wenhua Huang, Xinran Zhang, Huiqi Duan, Yuhao Ren, Xiaojing Zhang, Yongqiang Jiang, Ruili Zhao, Shaolong Chen

    Nipah virus (NiV) is an emerging zoonotic pathogen whose surface glycoprotein (G)-mediated host cell invasion mechanism leads to fatal encephalitis in infected patients (case fatality rate 40–75%). Given the limitations of existing diagnostic technologies, such as low sensitivity and prolonged processing times, we prepared an anti-NiV-G monoclonal antibody to establish a novel Amplified Luminescent Proximity Homogeneous Assay (AlphaLISA) detection system. Firstly, five high-affinity anti-NiV-G monoclonal antibodies were screened from the spleens of immunized mice by flow cytometry-single-cell cloning technology. The reaction system was further optimized, and the optimal dilution ratio of antibody-conjugated receptor microspheres, biotinylated antibodies, and donor microspheres was screened, and the AlphaLISA detection platform was successfully constructed. The detection sensitivity of NiV-G protein was 0.024 ng/mL (41.7 times higher than that of conventional ELISA), the coefficient of variation was <9.5%, and the repetition was good. It showed good specificity in the detection of 5 zoonotic viruses, including Japanese encephalitis virus and Zika virus. At the same time, this method is less disturbed by human serum, and the detection time is less than 30 min, showing a good clinical application prospect.


  • Open Access

    Development and Functional Characterization of Monoclonal Antibodies for Botulinum Neurotoxin Serotype A

    by Jingmei Kang, Qingyu Lv, Wenhua Huang, Hua Jiang, Shan Gao, Qian Li, Decong Kong, Guofen Zhao, Peng Liu, Yongqiang Jiang

    Botulinum neurotoxin serotype A (BoNT/A), the most toxic of the seven serotypes produced by Clostridium botulinum, poses significant public health risks because of its involvement in foodborne outbreaks and potential use in bioterrorism. In this study, we developed high-affinity monoclonal antibodies for BoNT/A detection using single-cell fluorescence-activated cell sorting and nested PCR. The optimized antibody pair demonstrated exceptional sensitivity, detecting recombinant BoNT/A at concentrations as low as 0.02 ng/mL with a linear range of 0.02–10 ng/mL, while maintaining high specificity against BoNT/B, E, and F. Biolayer interferometry confirmed superior binding kinetics, and a time-resolved fluoroimmunoassay (TRFIA) demonstrated consistent performance in complex food matrices, including ham sausage and soybean paste. These rabbit-derived monoclonal antibodies enable ultrasensitive detection of BoNT/A across diverse food matrices, offering a powerful tool for food safety monitoring and biosecurity.


  • Open Access

    The Genomic Characteristics of Potential Probiotics: Two Streptococcus salivarius Isolates from a Healthy Individual in China

    by Mingyue Sun, Qian Li, Feiran Zhang, Ding Yao, Wenhua Huang, Qingyu Lv, Hua Jiang, Decong Kong, Yuhao Ren, Shaolong Chen, et al.

    The isolation and characterization of novel probiotics from dairy products, fermented foods, and the gut have gained significant attention. In particular, Streptococcus salivarius shows promise for use in oral probiotic preparations. In this study, we isolated two strains of S. salivarius—S.82.15 and S.82.20—from the oral cavity of a healthy individual. These strains exhibited distinct antimicrobial profiles. We thoroughly assessed the morphology and growth patterns of both strains and confirmed auto-aggregation and hemolytic activity. Through comprehensive genomic analysis, we found notable strain differences within the same bacterial species isolated from the same individual. Notably, the presence or absence of plasmids varied between the two strains. The genome of S.82.15 spans 2,175,688 bps and contains 1994 coding DNA sequences (CDSs), while S.82.20 has a genome size of 2,414,610 bps, a GC content of 40.62%, and 2276 annotated CDSs. Both strains demonstrated antibacterial activity against Group A Streptococcus (GAS), Micrococcus. luteus, and Porphyromonas gingivalis. To investigate the antibacterial properties further, we identified a gene cluster of salivaricin 9 on the plasmid of S.82.20 and a blp gene family on the chromosomes of both S.82.15 and S.82.20. Moreover, the gene expression of the blp family was upregulated when the isolated strains were co-cultured with GAS.


  • Open Access

    Using Surface Immunogenic Protein as a Carrier Protein to Elicit Protective Antibody to Multiple Serotypes for Candidate Group B Streptococcal Glycan Conjugate Vaccines

    by Huiqi Duan, Wenhua Huang, Qingyu Lv, Peng Liu, Qian Li, Decong Kong, Xuyang Sun, Xinran Zhang, Yongqiang Jiang, Shaolong Chen

    Group B Streptococcus (GBS) is a life-threatening opportunistic pathogen, particularly in pregnant women, infants, and the elderly. Currently, maternal vaccination is considered the most viable long-term option for preventing GBS mother-to-infant infection, and two polysaccharide conjugate vaccines utilizing CRM197 as a carrier protein have undergone clinical phase II trials. Surface immunogenic protein (Sip), present in all identified serotypes of GBS strains so far, is a protective surface protein of GBS. In this study, the type Ia capsular polysaccharide (CPS) of GBS was utilized as a model to develop candidate antigens for a polysaccharide conjugate vaccine by coupling it with the Sip of GBS and the traditional carrier protein CRM197. Serum analysis from immunized New Zealand rabbits and CD1 mice revealed that there was no significant difference in antibody titers between the Ia-Sip group and Ia-CRM197 group; however, both were significantly higher than those observed in the Ia polysaccharide group. Opsonophagocytosis and passive immune protection results using rabbit serum indicated no significant difference between the Ia-Sip and Ia-CRM197 groups, both outperforming the Ia polysaccharide group. Furthermore, serum from the Ia-Sip group had a cross-protective effect on multiple types of GBS strains. The challenge test results in CD1 mice demonstrated that the Ia-Sip group provided complete protection against lethal doses of bacteria and also showed cross-protection against type III strain. Our study demonstrates for the first time that Ia-Sip is immunogenic and provides serotype-independent protection in glycan conjugate vaccines, which also indicates Sip may serve as an excellent carrier protein for GBS glycan conjugate vaccines and provide cross-protection against multiple GBS strains.


    • 1 December 2023
      • Vol. 39  (12) , 1089-1093

    [Comparison of two luminescence detection methods for staphylococcal enterotoxin C content in simulated milk samples].

    by Yuling Zheng, Ye Wang, Qingyu Lyu

    Objective To compare the sensitivity and accuracy of amplified luminescent proximity homogeneous assay linked immunosorbent assay (AlphaLISA) and magnetic particles-based chemiluminescence immunoassay (MP-CLIA) for detection of staphylococcal enterotoxin C (SEC) in the simulated milk samples. Methods The AlphaLISA was constructed using goat anti-SEC polyclonal antibody-coupled receptor microspheres, biotin-labeled SEC monoclonal antibody and streptavidin-coupled donor microspheres. The MP-CLIA was constructed using goat anti-SEC polyclonal antibody conjugated alkaline phosphatase, biotin-labeled anti-SEC monoclonal antibody and streptavidin conjugated magnetic beads. Results The sensitivity of AlphaLISA to detect SEC content in simulated milk samples was 4.04 ng/L, and the coefficient of variation (CV) was 1.98%~9.82%. The sensitivity of MP-CLIA was 108.19 ng/L and CV was 4.63%~20.40%. Conclusion Compared with MP-CLIA, AlphaLISA is more sensitive and accurate to detecting SEC.

  • Diagnosis of septic shock by serum measurement of human neutrophil lipocalin by a rapid homogeneous assay

    by Huijun Zong, Xueyi Shang, Xin Wang, Ting Chen, Ye Wang, Yuhao Ren, Yongqiang Jiang, Yan Li, Qingyu Lv, Peng Liu

  • Open Access

    Development of an AlphaLISA assay for sensitive and accurate detection of influenza B virus

    by Huijun Zong, Shengwei Zhang, Xueyi Shang, Hua Jiang, Zhongpeng Zhao, Shaolong Chen, Xin Wang, Ye Wang, Yongqiang Jiang, Xinyu Li, et al.

    Objective: Influenza B virus (IBV) is highly contagious, spreads rapidly, and causes seasonal epidemic respiratory disease in the human population, especially in immunocompromised people and young children. Clinical manifestations in this high-risk population are often more severe than in immunocompetent hosts and sometimes atypical. Therefore, rapid, and accurate detection of IBV is important.Methods: An amplified luminescent proximity homogeneous assay linked immunosorbent assay (AlphaLISA) was developed for detection of IBV by optimizing the ratio of IBV antibody-labeled receptor beads, streptavidin-conjugated donor beads and biotinylated IBV antibody, as well as the optimal temperature and time conditions for incubation. Assay sensitivity, specificity and reproducibility were evaluated. A total of 228 throat swab samples and inactivated influenza B virus were tested by AlphaLISA and lateral flow colloidal gold-based immunoassay (LFIA).Results: AlphaLISA produced the best results for detection of inactivated influenza B virus when IBV antibody-labeled acceptor beads were 50 μg/ mL, streptavidin-conjugated donor beads were 40 μg/mL, and biotinylated IBV antibody was 0.5 μg/mL at 37°C for 15–10 min. Under these conditions, AlphaLISA had a limit of detection of 0.24 ng/mL for the detection of influenza B nucleoprotein, did not cross react with other common respiratory viruses, and showed good reproducibility with inter-assay coefficient of variation (CV) and intra-assay CV < 5%. The results of 228 clinical throat swab samples showed good agreement between AlphaLISA and LFIA (Kappa = 0.982), and AlphaLISA showed better sensitivity than LFIA for detecting inactivated influenza B virus.Conclusion: AlphaLISA showed higher sensitivity and throughput in the detection of IBV and can be used for IBV diagnosis and epidemic control.


  • Open Access

    Development of a rapid homogeneous immunoassay for detection of rotavirus in stool samples

    by Ye Wang, Yuling Zheng, Yan Li, Shengwei Zhang, Xin Wang, Huijun Zong, Wenhua Huang, Decong Kong, Yongqiang Jiang, Peng Liu, et al.

    Rotavirus is the main pathogen causing acute viral gastroenteritis. Accurate and rapid diagnosis of rotavirus infection is important to determine appropriate treatment, prevention of unnecessary antibiotics use and control of infection spread. In this study, we established a rapid, accurate, and sensitive amplified luminescent proximity homogeneous assay linked immunosorbent assay (AlphaLISA) for detecting rotavirus and evaluated its efficacy in human stool samples. Our results demonstrated that the sensitivity of AlphaLISA (5−8) significantly exceeded that of the immunochromatographic assay (ICA, 5−4) for rotavirus antigen detection. The intra-assay and inter-assay coefficients of variation were 2.99–3.85% and 5.27–6.51%, respectively. Furthermore, AlphaLISA was specific for rotavirus and did not cross-react with other common diarrhea viruses. AlphaLISA and real-time reverse transcription polymerase chain reaction (RT-qPCR, which is considered a gold standard for detecting diarrhea viruses) tests showed consistent results on 235 stool samples, with an overall consistency rate of 97.87% and a kappa value of 0.894 (P < 0.001). The overall consistency rate of ICA compared with RT-qPCR was 95.74%. AlphaLISA showed better consistency with RT-qPCR than the routinely used ICA for rotavirus detection in stool samples. The AlphaLISA method can be used in clinical practice for the rapid, accurate, and sensitive detection of rotavirus infection.


  • Open Access

    Suilyin Disrupts the Blood–Brain Barrier by Activating Group III Secretory Phospholipase A2

    by Yutong Sui, Ying Chen, Qingyu Lv, Yuling Zheng, Decong Kong, Hua Jiang, Wenhua Huang, Yuhao Ren, Peng Liu, Yongqiang Jiang

    Serious diseases caused by Streptococcus suis serotype 2 (S. suis 2) include septicaemia and meningitis, which are associated with high morbidity and mortality. Proliferation in the blood can result in a breach of the blood–brain barrier (BBB) and provide entry into the cerebrospinal fluid (CSF), where bacteria cause inflammation of the meningeal membranes resulting in meningitis. The molecular mechanisms of how this pathogen crosses the BBB remain unclear. Suilysin (SLY) has been identified as an important secreted virulence factor of S. suis 2 and may play a vital role in provoking meningitis. In this investigation, we demonstrate that SLY can increase the paracellular permeability of BBB, both in vivo and in vitro, via the activation of group III secretory phospholipase A2 (PLA2G3). Our results indicate that at lower, sublytic concentrations, the toxin can stimulate cerebral microvascular endothelial cells to release TNF-α, thereby inducing high level expressions of PLA2G3. Abnormal elevations of PLA2G3 might further injure tissues through direct cytolytic effectors or other responses.