MVMaria Victorova

Maria Victorova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maria Victorova has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of ultrasound scanning for scoliosis assessment: Robotic versus manual

    by Maria Victorova, Heidi Hin Ting Lau, Timothy Tin‐Yan Lee, David Navarro‐Alarcon, Yongping Zheng

    Background: Ultrasound (US) imaging for scoliosis assessment is challenging for a non‐experienced operator. The robotic scanning was developed to follow a spinal curvature with deep learning and apply consistent forces to the patient's back.Methods: Twenty three scoliosis patients were scanned with US device both, robotically and manually. Two human raters measured each subject's spinous process angles on robotic and manual coronal images.Results: The robotic method showed high intra‐ (ICC > 0.85) and inter‐rater (ICC > 0.77) reliabilities. Compared with the manual method, the robotic approach showed no significant difference (p < 0.05) when measuring coronal deformity angles. The mean absolute deviation for intra‐rater analysis lies within an acceptable range from 0 to 5° for the minimum of 86% and maximum 97% of a total number of the measured angles.Conclusions: This study demonstrated that scoliosis deformity angles measured on ultrasound images obtained with robotic scanning are comparable to those obtained by manual scanning.


  • Ultrasound-Guided Assistive Robots for Scoliosis Assessment With Optimization-Based Control and Variable Impedance

    by Anqing Duan, Maria Victorova, Jingyuan Zhao, Yuxiang Sun, Yongping Zheng, David Navarro-Alarcon

    Assistive robots for healthcare have witnessed a growing demand over the past decades. In this letter, we investigate the development of an optimization-based control framework with variable impedance for an assistive robot to perform ultrasound-guided scoliosis assessment. The conventional procedure for scoliosis assessment using ultrasound imaging typically requires a medical practitioner to slide an ultrasound probe along a patient’s back while maintaining a certain magnitude of the contact force. To automate such a procedure, we need to consider multiple objectives, such as contact force, position, orientation, energy, posture, etc. To coordinate different objectives, we propose to formulate the control framework as a quadratic programming problem with each objective weighted by a tunable task priority, subject to a set of equality and inequality constraints. As the procedure requires the robot to establish a constant contact force with the patient during scanning, we incorporate variable impedance regulation of the end-effector to enhance safety and stability during the physical human-robot interaction; The variable impedance gains are then retrieved by learning from medical expert’s demonstrations. The proposed methodology is evaluated with a robotic system performing autonomous scoliosis assessment with multiple human subjects involved. The effectiveness of our approach is verified by the coronal spinal images obtained with the robot.


  • Open Access

    Follow the Curve: Robotic Ultrasound Navigation With Learning-Based Localization of Spinous Processes for Scoliosis Assessment

    by Maria Victorova, Michael Ka-Shing Lee, David Navarro-Alarcon, Yongping Zheng

    The scoliosis progression in adolescents requires close monitoring to timely take treatment measures. Ultrasound imaging is a radiation-free alternative in scoliosis assessment to X-ray, which is typically used in clinical practice. However, ultrasound images are prone to speckle noise, making it challenging for sonographers to detect bony features and follow the spinal curvature. This study introduces a novel robotic ultrasound approach for spinous process localization and automatic spinal curvature tracking for scoliosis assessment. The positions of the spinous processes are computed using a fully connected network with a deconvolutional head. A 5-fold cross-validation was performed on a dataset of ultrasound images from 25 human subjects with scoliosis. The resulting percentage of correct keypoints of the spinous process is 0.966±0.027 with a mean distance error of 1.0±0.99 mm. We use this machine learning-based method to guide the motion of the robot-held ultrasound probe and to follow the spinal curvature while capturing ultrasound images. We present a new force-driven controller that automatically adjusts the pose and orientation of the probe relative to the skin surface, which ensures a good acoustic coupling between the probe and skin. We extended the network architecture to additionally perform classification of the spine into its regions, i.e., sacrum, lumbar, and thoracic, which are used to adjust the probe’s orientation to account for the varying curvature along the spine. After the autonomous scanning, the acquired data is used to reconstruct the coronal spinal image, where the deformity of the scoliosis spine can be assessed and measured. The proposed learning-based method for anatomical landmarks localization was compared to conventional methods based on phase symmetry and image intensity. The learning-based method proved to be more precise for spinous process localization while processing images at a faster rate, which is advantageous for real-time scoliosis scanning. To evaluate the performance of our robotic method, we conducted an experimental study with human scoliosis subjects where deviations of the spinous process from the image center can be compared to those appearing in a manual scan. Our results show that the robotic approach reduces the mean error of spinal curvature following for mild scoliosis from 4.6±4.6mm (manual scanning) to 1.0±0.8mm (robotic scanning); For moderate scoliosis from 4.3±3.9mm (manual scanning) to 2.8±1.8mm (robotic scanning). The angles of spinal deformity measured on spinal reconstruction images were similar for both methods, implying that they equally reflect human anatomy. The spinal region-specific moment-based probe orientation control showed to improve the scanning performance. An ablation study was performed to investigate the importance of each component of the proposed system.


  • Force-Ultrasound Fusion: Bringing Spine Robotic-US to the Next “Level”

    by Maria Tirindelli, Maria Victorova, Javier Esteban, Seong Tae Kim, David Navarro-Alarcon, Yong Ping Zheng, Nassir Navab

    Spine injections are commonly performed in several clinical procedures. The localization of the target vertebral level (i.e. the position of a vertebra in a spine) is typically done by back palpation or under X-ray guidance, yielding either higher chances of procedure failure or exposure to ionizing radiation. Preliminary studies have been conducted in the literature, suggesting that ultrasound imaging may be a precise and safe alternative to X-ray for spine level detection. However, ultrasound data are noisy and complicated to interpret. In this study, a robotic-ultrasound approach for automatic vertebral level detection is introduced. The method relies on the fusion of ultrasound and force data, thus providing both “tactile” and visual feedback during the procedure, which results in higher performances in presence of data corruption. A robotic arm automatically scans the volunteer's back along the spine by using force-ultrasound data to locate vertebral levels. The occurrences of vertebral levels are visible on the force trace as peaks, which are enhanced by properly controlling the force applied by the robot on the patient back. Ultrasound data are processed with a Deep Learning method to extract a 1D signal modelling the probabilities of having a vertebra at each location along the spine. Processed force and ultrasound data are fused using a 1D Convolutional Network to compute the location of the vertebral levels. The method is compared to pure image and pure force-based methods for vertebral level counting, showing improved performance. In particular, the fusion method is able to correctly classify 100% of the vertebral levels in the test set, while pure image and pure force-based method could only classify 80% and 90% vertebrae,