NGNiccolò Gallice

Niccolò Gallice

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Niccolò Gallice has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • nEXO radioassay program

    by R. MacLellan, P. Acharya, B. Aharmim, S. Alcantar Anguiano, A. Anker, I. J. Arnquist, D. Auty, T. Bhatta, D. Chernyak, J. S. Choe, et al.

  • Open Access

    Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD

    by S. Abbaslu, F. Abd Alrahman, A. Abed Abud, R. Acciarri, L.P. Accorsi, M.A. Acero, M.R. Adames, G. Adamov, M. Adamowski, K. Adhikari, et al.

    DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.

  • Open Access

    Measurement of exclusive π + -argon interactions using ProtoDUNE-SP

    by S. Abbaslu, A. Abed Abud, R. Acciarri, L. P. Accorsi, M. A. Acero, M. R. Adames, G. Adamov, M. Adamowski, C. Adriano, F. Akbar, et al.

    We present the measurement of π + -argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident π + kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of π + -argon secondary interactions within the liquid argon. This is the first measurement of π + -argon absorption at this kinetic energy range as well as the first ever measurement of π + -argon charge exchange.


  • Open Access

    Operation of a tunable Power over Fiber system for light detectors down to 4.6 K

    by A. Andreani, C. Brizzolari, E.J. Cristaldo Morales, M.J. Delgado Gonzalez, A. Falcone, N. Gallice, C. Gotti, M. Lazzaroni, L. Meazza, G. Pessina, et al.

    The Power over Fiber (PoF) technology delivers electrical power by transmitting laser light through a lightweight, non-conductive fiber optic cable to a remote photovoltaic optical converter, which in turn powers sensors or electrical devices. Among the several advantages offered by this solution are spark-free operation in the presence of electric fields, elimination of noise induced by power lines, immunity to electromagnetic interference, and high robustness in hostile environments. The R&D for the application of PoF in cryogenic environments started at FNAL and BNL (U.S.A.) in 2020 to power the Photon Detection System of the DUNE Vertical Drift module. This paper presents the results obtained in the framework of Cryo-PoF project where we developed a single-laser input line system to power an electronic amplifier and the photosensors at cryogenic temperatures. Unlike the DUNE solution, our system allows tuning of the photosensor bias by adjusting the input laser power. We also demonstrate the operation of the optical converter at temperatures down to 4.6 K, opening the possibility of using this technology in a much broader range of applications.

  • Ultra-pure nickel for structural components of low-radioactivity instruments

    by T.J. Roosendaal, C.T. Overman, G.S. Ortega, T.D. Schlieder, N.D. Rocco, L.K.S. Horkley, K.P. Hobbs, K. Harouaka, J.L. Orrell, P. Acharya, et al.


  • Open Access

    First use of large area SiPM matrices coupled with NaI(Tl) scintillating crystal for low energy dark matter search

    by Edoardo Martinenghi, Valerio Toso, Fabrizio Bruno Armani, Andrea Castoldi, Giuseppe Di Carlo, Luca Frontini, Niccolò Gallice, Chiara Guazzoni, Valentino Liberali, Alberto Stabile, et al.

    The long-standing claim of dark matter detection by the DAMA experiment remains a crucial open question in astroparticle physics. A key step towards its independent verification is the development of NaI(Tl)-based detectors with improved sensitivity at low energies. The majority of NaI(Tl)-based experiments rely on conventional photomultiplier tubes (PMTs) as single photon detectors, which present technological limitations in terms of light collection, intrinsic radioactivity and high noise contribution at keV energies. ASTAROTH is an R&D project developing a NaI(Tl)-based detector where the scintillation light is read out by silicon photomultipliers (SiPMs) matrices. SiPMs exhibit high photon detection efficiency, negligible radioactivity, and, most importantly, a dark noise nearly two orders of magnitude lower than PMTs, when operated at cryogenic temperature. To this end, ASTAROTH features a custom-designed cryostat based on a bath of cryogenic fluid, able to safely operate the detector and the read-out electronics down to about 80 K. This work reports the first experimental characterization of an approximately 360 g NaI(Tl) detector read out by a large area (5 cm $$\times $$ × 5 cm) SiPM matrix. The net photoelectron yield obtained with a preliminary configuration is approximately 4.5 photoelectrons/keV after crosstalk correction, which is rather promising in light of several planned developments. The signal-to-noise ratio and the energy threshold attainable with SiPMs is expected to improve the sensitivity for dark matter searches beyond the reach of current-generation PMT-based detectors. This result is the first proof of the viability of this technology and sets a milestone toward the design of future large-scale experiments.


  • Open Access

    ASTAROTH: a novel detector for dark matter direct detection using cryogenic SiPMs

    by E. Martinenghi, V. Toso, F.B. Armani, A. Castoldi, G. Di Carlo, L. Frontini, N. Gallice, C. Guazzoni, V. Liberali, L. Rutigliani, et al.

    The DAMA experiment's long-standing claim of dark matter detection remains a key open issue in astroparticle physics. Independent verification requires NaI(Tl)-based detectors with enhanced low-energy sensitivity. Current detectors rely on photomultiplier tubes (PMTs) which features limited detection efficiency, intrinsic radioactivity, and high noise at few-keV energies. ASTAROTH is an R&D project that developed a proof of concept NaI(Tl) detector where silicon photomultipliers (SiPMs) have been used instead of PMTs, offering higher photon detection efficiency, negligible radioactivity, and, most of all, a reduction of two orders of magnitude in the dark noise. The setup includes a custom cryostat operating at approximately 80 K. We report the first characterization of an approximately 360 g NaI(Tl) crystal coupled to a 5 × 5 cm 2 SiPM matrix, yielding 4.5 photoelectrons/keV after crosstalk correction. This promising result demonstrates the feasibility of SiPM-based readout for NaI(Tl) and paves the way for future large-scale dark matter experiments.


  • Open Access

    Ultra-pure Nickel for Structural Components of Low-Radioactivity Instruments

    by T. J. Roosendaal, C. T. Overman, G. S. Ortega, T. D. Schlieder, N. D. Rocco, L. K. S. Horkley, K. P. Hobbs, K. Harouaka, J. L. Orrell, P. Acharya, et al.

    The next generation of rare-event search experiments in nuclear and particle physics demand structural materials combining exceptional mechanical strength with ultra-low levels of radioactive contamination. This study evaluates chemical vapor deposition (CVD) nickel as a candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates underwent tensile testing before and after welding alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, welding and heat treatment were found to reduce the tensile strength to levels comparable to standard Ni, with observed porosity in the welds likely contributing to this reduction. Material assay via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution produced measured bulk concentration of 232-Th, 238-U, and nat-K at the levels of ~70 ppq, <100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 micrometer beneath the surface, likely associated with the aluminum growth substrate. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in welding and surface cleaning techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.

  • Scintillation light detection in polycrystalline diamond using single photon detectors

    by Niccolò Gallice, Aleksey Bolotnikov, Erik M. Muller, Thomas Tsang