Peter Mueller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peter Mueller has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Ferraris
IBM Research EuropeZurich, Rschlikon, Switzerland
2 shared publications - Douglas M. Dahl
Department of Urology, Massachusetts General Hospital, Harvard Medical School, Boston, USA
2 shared publications Eunjung Cha
IBM Research, Rueschlikon, Switzerland
2 shared publications- Gui-Lu Long
Beijing Academy of Quantum Information Sciences, Beijing, China.
2 shared publications - Ruidong Li
Institute of Science and Engineering, Kanazawa University, Kakuma, Kanazawa, Japan
2 shared publications S. Paredes
IBM Quantum, IBM Research Europe–Zurich 1 , Säumerstrasse 4, 8803 Rüschlikon, Switzerland
2 shared publications
Latest Publications
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Network
- Vol. 40 (4) , 14-15
Quantum Communications and Networking: Series 4
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Network
- Vol. 40 (4) , 14-15
Quantum Communications and Networking: Series 4
- Top Cited Papers
- 31 October 2024
- Published by Springer Nature in Nature Electronics
- Vol. 7 (11) , 966-974
Energy-efficient computing at cryogenic temperatures
- 31 October 2024
- Published by Springer Nature in Nature Electronics
- Vol. 7 (11) , 966-974
Top Cited PapersEnergy-efficient computing at cryogenic temperatures
- Open Access
- 15 October 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-7
Cryogenic quantum computer control signal generation using high-electron-mobility transistors
Multiplexed local charge storage, close to quantum processors at cryogenic temperatures could generate a multitude of control signals, for electronics or qubits, in an efficient manner. Such cryogenic electronics require generating quasi-static control signals with small area footprint, low noise, high stability, low power dissipation and, ideally, in a multiplexed fashion to reduce the number of input/outputs. In this work, we integrate capacitors with cryogenic high-electron mobility transistor (HEMT) arrays and demonstrate quasi-static bias generation using gate pulses controlled in time and frequency domains. Multi-channel bias generation is also demonstrated. Operation at 4 K exhibits improved bias signal variability and greatly reduced subthreshold swing, reaching values of ~6 mV/decade. Due to the very low threshold voltage of 80 mV at 4 K and the steep subthreshold swing, these circuits can provide an advantage over the silicon-based complementary metal-oxide-semiconductor equivalents by allowing operation at significantly reduced drive bias in the low output voltage regime <1 V. Together with their high-speed operation, this makes HEMTs an attractive platform for future cryogenic signal generation electronics in quantum computers.
- 15 October 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-7
Open AccessCryogenic quantum computer control signal generation using high-electron-mobility transistors
Multiplexed local charge storage, close to quantum processors at cryogenic temperatures could generate a multitude of control signals, for electronics or qubits, in an efficient manner. Such cryogenic electronics require generating quasi-static control signals with small area footprint, low noise, high stability, low power dissipation and, ideally, in a multiplexed fashion to reduce the number of input/outputs. In this work, we integrate capacitors with cryogenic high-electron mobility transistor (HEMT) arrays and demonstrate quasi-static bias generation using gate pulses controlled in time and frequency domains. Multi-channel bias generation is also demonstrated. Operation at 4 K exhibits improved bias signal variability and greatly reduced subthreshold swing, reaching values of ~6 mV/decade. Due to the very low threshold voltage of 80 mV at 4 K and the steep subthreshold swing, these circuits can provide an advantage over the silicon-based complementary metal-oxide-semiconductor equivalents by allowing operation at significantly reduced drive bias in the low output voltage regime <1 V. Together with their high-speed operation, this makes HEMTs an attractive platform for future cryogenic signal generation electronics in quantum computers.
- 13 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Network
- Vol. 38 (5) , 112-113
Quantum Communications and Networking: Series 2
- 13 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Network
- Vol. 38 (5) , 112-113
Quantum Communications and Networking: Series 2
- 1 February 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (2) , 025121
Ultrahigh vacuum packaging and surface cleaning for quantum devices
We describe design, implementation, and performance of an ultra-high vacuum (UHV) package for superconducting qubit chips or other surface sensitive quantum devices. The UHV loading procedure allows for annealing, ultra-violet light irradiation, ion milling, and surface passivation of quantum devices before sealing them into a measurement package. The package retains vacuum during the transfer to cryogenic temperatures by active pumping with a titanium getter layer. We characterize the treatment capabilities of the system and present measurements of flux tunable qubits with an average T1 = 84 µs and μs after vacuum-loading these samples into a bottom loading dilution refrigerator in the UHV-package.- 1 February 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (2) , 025121
Ultrahigh vacuum packaging and surface cleaning for quantum devices
We describe design, implementation, and performance of an ultra-high vacuum (UHV) package for superconducting qubit chips or other surface sensitive quantum devices. The UHV loading procedure allows for annealing, ultra-violet light irradiation, ion milling, and surface passivation of quantum devices before sealing them into a measurement package. The package retains vacuum during the transfer to cryogenic temperatures by active pumping with a titanium getter layer. We characterize the treatment capabilities of the system and present measurements of flux tunable qubits with an average T1 = 84 µs and μs after vacuum-loading these samples into a bottom loading dilution refrigerator in the UHV-package.- 2 October 2020
- Published by Elsevier in Advanced Powder Technology
- Vol. 31 (10) , 4376-4389
Measurement and evaluation of the grinding bodies’ motions in a vibratory disc mill filled with viscous fluids
- 2 October 2020
- Published by Elsevier in Advanced Powder Technology
- Vol. 31 (10) , 4376-4389
Measurement and evaluation of the grinding bodies’ motions in a vibratory disc mill filled with viscous fluids
- Open Access
- 18 September 2020
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 2 (3) , 033447
Benchmarking the noise sensitivity of different parametric two-qubit gates in a single superconducting quantum computing platform
The possibility to utilize different types of two-qubit gates on a single quantum computing platform adds flexibility in the decomposition of quantum algorithms. A larger hardware-native gate set may decrease the number of required gates, provided that all gates are realized with high fidelity. Here, we benchmark both controlled- (CZ) and exchange-type (iSWAP) gates using a parametrically driven tunable coupler that mediates the interaction between two superconducting qubits. Using randomized benchmarking protocols we estimate an error per gate of and for the CZ and the iSWAP gate, respectively. We argue that spurious -type couplings are the dominant error source for the iSWAP gate, and that phase stability of all microwave drives is of utmost importance. Such differences in the achievable fidelities for different two-qubit gates have to be taken into account when mapping quantum algorithms to real hardware.- 18 September 2020
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 2 (3) , 033447
Open AccessBenchmarking the noise sensitivity of different parametric two-qubit gates in a single superconducting quantum computing platform
The possibility to utilize different types of two-qubit gates on a single quantum computing platform adds flexibility in the decomposition of quantum algorithms. A larger hardware-native gate set may decrease the number of required gates, provided that all gates are realized with high fidelity. Here, we benchmark both controlled- (CZ) and exchange-type (iSWAP) gates using a parametrically driven tunable coupler that mediates the interaction between two superconducting qubits. Using randomized benchmarking protocols we estimate an error per gate of and for the CZ and the iSWAP gate, respectively. We argue that spurious -type couplings are the dominant error source for the iSWAP gate, and that phase stability of all microwave drives is of utmost importance. Such differences in the achievable fidelities for different two-qubit gates have to be taken into account when mapping quantum algorithms to real hardware. - Open Access
- 1 July 2019
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 7 (S3) , S113
Urologic and interventional radiology treatment of renal cell carcinomas—similarities and differences
- 1 July 2019
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 7 (S3) , S113
Open AccessUrologic and interventional radiology treatment of renal cell carcinomas—similarities and differences
- Open Access
- 1 July 2014
- Published by SAGE Publications in Journal of Palliative Medicine
- Vol. 17 (7) , 811-821
Palliative Gastrostomy in the Setting of Voluminous Ascites
We report the indications, methods, and complications of percutaneous gastrostomy/gastrojejunostomy (G/GJ) in patients with voluminous ascites. Following institutional review board approval, 69 patients (14 male, 55 female, mean age 58±12 years, range 32-89 years) who underwent percutaneous G/GJ with paracentesis were identified from a prospectively acquired database. Electronic medical record data extracted included diagnosis, method of G/GJ insertion, clinical course, and complications, which were graded by The Society of Interventional Radiology (SIR) criteria. Statistics were performed using Graphpad Instat. Sixty-six G and three GJ catheters were placed in 62 patients with malignant and 7 patients with benign disease; 47 procedures were conducted using fluoroscopy and 22 using computed tomography (CT; 10 patients had failed fluoroscopy). Sixty-six patients had 1980±1371 mL (range, 20-5000 mL) ascites drained (more in males, p=0.01) 0.8±1.6 days (range, 0-5 days) prior to placement. Forty-one patients had significantly less ascites (1895±1426 mL; range, 100-5400 mL) drained after G/GJ (p>0.0.5). Mean survival after insertion was 43±57 days (range, 1-252 days) among 38 patients for whom data were available. Fifty-six patients had a mean postprocedure hospital stay of 8.6±8.4 days (range, 0-45 days); 3 were outpatients and 10 patients died in the hospital. Successful gastropexy was confirmed on subsequent cross-sectional imaging in 22 of 25 patients. There were 25 tube maintenance issues that included catheter displacement and leakage, one patient experienced hemorrhage, and there were two deaths. All except one patient had satisfactory gastrostomy function. Effective G/GJ placement is possible in most patients with voluminous ascites provided ascites is drained and gastrocutaneous fistula formation occurs. Caution is advised; placement is generally for fragile terminal patients, and fluoroscopy or CT guidance is required.
- 1 July 2014
- Published by SAGE Publications in Journal of Palliative Medicine
- Vol. 17 (7) , 811-821
Open AccessPalliative Gastrostomy in the Setting of Voluminous Ascites
We report the indications, methods, and complications of percutaneous gastrostomy/gastrojejunostomy (G/GJ) in patients with voluminous ascites. Following institutional review board approval, 69 patients (14 male, 55 female, mean age 58±12 years, range 32-89 years) who underwent percutaneous G/GJ with paracentesis were identified from a prospectively acquired database. Electronic medical record data extracted included diagnosis, method of G/GJ insertion, clinical course, and complications, which were graded by The Society of Interventional Radiology (SIR) criteria. Statistics were performed using Graphpad Instat. Sixty-six G and three GJ catheters were placed in 62 patients with malignant and 7 patients with benign disease; 47 procedures were conducted using fluoroscopy and 22 using computed tomography (CT; 10 patients had failed fluoroscopy). Sixty-six patients had 1980±1371 mL (range, 20-5000 mL) ascites drained (more in males, p=0.01) 0.8±1.6 days (range, 0-5 days) prior to placement. Forty-one patients had significantly less ascites (1895±1426 mL; range, 100-5400 mL) drained after G/GJ (p>0.0.5). Mean survival after insertion was 43±57 days (range, 1-252 days) among 38 patients for whom data were available. Fifty-six patients had a mean postprocedure hospital stay of 8.6±8.4 days (range, 0-45 days); 3 were outpatients and 10 patients died in the hospital. Successful gastropexy was confirmed on subsequent cross-sectional imaging in 22 of 25 patients. There were 25 tube maintenance issues that included catheter displacement and leakage, one patient experienced hemorrhage, and there were two deaths. All except one patient had satisfactory gastrostomy function. Effective G/GJ placement is possible in most patients with voluminous ascites provided ascites is drained and gastrocutaneous fistula formation occurs. Caution is advised; placement is generally for fragile terminal patients, and fluoroscopy or CT guidance is required.
- 1 April 2011
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 185 (4S) , e283
704 PERCUTANEOUS RENAL MASS BIOPSY: IF THEY'RE POSITIVE, THEY'RE POSITIVE, BUT IF THEY'RE NEGATIVE, BE CAREFUL! A CORRELATION BETWEEN RENAL BIOPSY AND SURGICAL PATHOLOGY
Percutaneous biopsy is an emerging modality in the study of small renal masses. We correlated biopsy pathology results with surgical pathology specimens to investigate the concordance of the pathologic diagnoses.
- 1 April 2011
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 185 (4S) , e283
704 PERCUTANEOUS RENAL MASS BIOPSY: IF THEY'RE POSITIVE, THEY'RE POSITIVE, BUT IF THEY'RE NEGATIVE, BE CAREFUL! A CORRELATION BETWEEN RENAL BIOPSY AND SURGICAL PATHOLOGY
Percutaneous biopsy is an emerging modality in the study of small renal masses. We correlated biopsy pathology results with surgical pathology specimens to investigate the concordance of the pathologic diagnoses.