TSTauan Rosa Santana

Tauan Rosa Santana

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tauan Rosa Santana has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Surrounding and background shades effect on color adjustment of single-shade composites

    by Márcia Luciana Carregosa Santana, Gabriella de Jess Santos Livi, Tauan Rosa Santana, Paula Fernanda Damasceno Silva, Clara Lemos Leal Barata de Matos, Carolina Menezes Maciel, André Luis Faria-E-Silva

    This study evaluated the effects of surrounding and background shades on the color adjustment potential (CAP) and visual color match of two single-shade composites, Vittra APS Unique and Charisma Diamond One. Cylinder-shaped specimens were constructed, consisting of either single-shade composites alone (simple) or composites surrounded by the Forma material at shades A1 or A3 (dual). Simple specimens using only the Forma at the specified shades were also prepared. Color measurements of simple specimens were taken against a gray background using a spectrophotometer. For dual specimens, the color of the inner composite was measured against a gray or chromatic (the same shade as the outer composite) background. Color differences (ΔE00) between the single-shade composites and the A1/A3 composite were calculated. CAP was determined by comparing data from simple and dual specimens. Four experienced dentists scored the color match (perfect to unacceptable) for each specimen using a viewing booth illuminated by an illuminant D65. Data were analyzed with repeated-measures ANOVA and the Kruskal-Wallis test. The results showed that both single-shade composites showed the lowest color discrepancies when they were compared to A1 and A3. Using a chromatic background only significantly affected the CAP when the outer composite was A3. The visual analysis showed poor color matches between the single-shade and control chromatic composites, except for Charisma Diamond One surrounded by A1. In conclusion, the CAP values of the evaluated single-shade composites were impacted by both surrounding shade and background color, and the color match of these materials tended to be poor.


  • Open Access

    Influence of repositioning guides’ color and usage on precision in tooth color measurement with a clinical spectrophotometer

    by Tauan Rosa Santana, Paula Fernanda Damasceno Silva, Márcia Luciana Carregosa Santana, Clara Lemos Leal Barata de Mattos, André Luis Faria-E-Silva

    Repositioning guides are commonly employed in clinical studies to ensure consistent tooth color measurements. Yet, their influence on measured color remains uncertain.


  • Open Access

    Resinas compostas monocromáticas: Uma abordagem em caso clínico

    by Thalia Santos Silva, Mirelle Domingues Ferreira de Oliveira, Ádila Santos Almeida, Ítalo Samuel Gonçalves Rodrigues, Tauan Rosa de Santana

    With the advancement of aesthetics, it is necessary to constantly evolve dental materials in search of natural mimicry. As a result, monochromatic resins emerged, bringing the famous chameleon effect capable of adapting to the colors of the walls surrounding the teeth, providing a restorative material that is pleasantly aesthetic and easy to handle, eliminating the need to select the color of the teeth and the use of different resins, thus reducing the time in the dental chair. The objective of this study was to evaluate the effectiveness of monochromatic composite resins, demonstrating their use and effectiveness in the dental office through a clinical case. Patient MJMS, 70 years old, attended the dental clinic of Universidade Tiradentes (UNIT) complaining of tooth sensitivity due to the fracture of the cervical restoration of tooth 26. The chosen treatment was restoration with the unit's monochromatic composite, which served well clinical need, optimizing service time. Monochromatic composite resin is a great material available on the market because of its ability to mimic natural teeth, achieving a pleasant aesthetic, associated with the practicality of shorter clinical time.

  • Open Access

    Reabilitação estética em dentes anteriores após trauma dental utilizando a técnica da matriz BRB e estratificação - Relato de caso

    by Ítalo Samuel Gonçalves Rodrigues, Denilson dos Santos Gomes, Josiene Souza Santos, Alícia Beatriz Fontes de Souza, André Henrique Gomes dos Santos, Wallison Rodrigues Avelino dos Santos, Andrielly Ferreira Nascimento, Clara Lemos Leal Barata de Mattos, Tauan Rosa de Santana

    Cases of dental trauma are common in the dental office routine, which mostly affect children and adolescents. The main causes of injuries are sporting activities, falls, accidents and violence. Therefore, the present study aims to report a clinical case of fracture of the middle/incisal third of units 11 and 21, where direct restorations were performed in composite resin, using the BRB matrix technique through layering, employing the simplified system of Tetric N-Ceram composite resin. The BRB matrix technique consists of silicone molding of the initial clinical condition and direct wear on the mold itself, simulating the palatal shell and tooth contours. The main advantage of the technical option is that it is carried out in a single clinical session, eliminating the need for laboratory waxing procedures, providing lower costs and facilitating the construction of the functional characteristics of the palatal support, being of great clinical interest due to its practicality for both the patient and the dental surgeon. Finally, it was possible to restore the affected units efficiently, restoring the patient's aesthetics and function and minimizing the trauma that a fractured anterior tooth can cause.

  • Effects of enamel moistening and repositioning guide color on tooth whitening outcomes: A clinical trial

    by Tauan Rosa Santana, Paula Fernanda Damasceno Silva, Márcia Luciana Carregosa Santana, Clara Lemos Leal Barata de Mattos, André Luis Faria‐E‐Silva

    This clinical trial investigated the effects of pre‐application enamel moistening on the impact of a 37% carbamide peroxide whitener on tooth color changes and the influence of repositioning guide colors. Forty participants were randomly assigned to in‐office tooth bleaching with either moistened enamel (experimental) or dry enamel (control). The whitener was applied for 45 min over two sessions. Tooth color was visually measured or assessed using a spectrophotometer with purple or green silicone guides. Tooth bleaching was assessed using CIE76 (ΔEab) and CIEDE2000 (ΔE00) formulas and by whitening and bleaching index score changes. Moistening the enamel did not significantly affect tooth color. However, the guide color choice only impacted tooth color when measured instrumentally. At baseline, the green guide resulted in statistically significantly whiter teeth than the purple guide. Less pronounced differences in the b* coordinate between baseline and final measurements were found using the green guide. The green guide also produced lower ΔEab values and less change in indexes. In conclusion, moistening the enamel did not significantly impact tooth color changes. However, the repositioning guide color influenced the tooth bleaching measured instrumentally, except for ΔE00.


  • The role of interface distance and underlying substrate on the color adjustment potential of single‐shade composites

    by Gabriella Jesus Santos de Livi, Tauan Rosa Santana, Rafaella Mariana Fontes Bragança, Rosa Maria Viana de Bragança Garcez, André Luis Faria‐E‐Silva

    Objective: This study assessed how the distance from the composite interface and the underlying chromatic substrate affect the color adjustment potential (CAP) of two single‐shade composites.Materials and Methods: Cylinder‐shaped specimens were created using Vittra APS Unique (VU), Charisma Diamond One (DO), and a shaded (A3) composite. Some single‐shade specimens were surrounded by the A3 composite, forming dual specimens. Color measurements of simple specimens were taken against a gray background using a spectrophotometer. All specimens were positioned at a 45° angle in a viewing booth under illuminant D65, and images were captured with a DSLR camera against gray or A3 backgrounds. Image colors were measured using image processing software and converted to CIELAB coordinates. Color differences (ΔE00) between the single‐shade composites and the A3 composite were calculated. CAP was determined by comparing data from simple and dual specimens.Results: No clinically significant differences were observed between color measurements obtained from images and the spectrophotometer. CAP was higher for DO compared to VU and increased as the distance from the composite interface decreased and when specimens were positioned against an A3 background.Conclusion: The color adjustment potential increased with decreased distance from the composite interface and against a chromatic background.Clinical Significance: Achieving satisfactory color match in restorations using single‐shade composites is crucial, and selecting an appropriate underlying substrate is essential. The color adjustment gradually decreases from the restoration margins towards its center.


  • Color heterogeneity and individual color changes in dentin and enamel bleached in the presence of a metallic orthodontic bracket

    by Isadora de Melo Oliveira, Tauan Rosa Santana, Ana Claudia Conceição Correia, Lucas Silva Fontes, Sandro Griza, André Luis Faria‐E‐Silva

    Objective This in-vitro study evaluated the color changes in enamel and dentin bleached in the presence of an orthodontic bracket, as well as the heterogeneity of the color and contribution of each tissue to the color change (CTCC). Materials and Methods Enamel-dentin specimens from extracted bovine teeth were bleached before or after bracket removal or maintained without any treatment (control). The colors of the dentin and enamel were measured individually and after recombining these substrates. The changes in the color (Delta E-00) and whitening index (Delta WID) were estimated by the color difference between the bleached specimens and those of the control. The CTCC was also calculated by recombining the tissues from different treatments. Images of specimens obtained from a stereomicroscope were used to analyze the color homogeneity within each tissue. Results The highest values of Delta E(00)and Delta WID were observed in the specimens bleached in the absence of a bracket. Bleaching in the presence of a bracket resulted in enamel with a center that was whiter than the periphery. Dentin and enamel presented similar CTCC values. Conclusions Tooth bleaching performed in the presence of a metallic bracket resulted in a reduced bleaching effect and increased color heterogeneity within both tissues. Clinical Significance Tooth bleaching before the orthodontic bracket removal reduces the bleaching effect in both dentin and enamel. Moreover, a heterogeneous color of enamel surface can be observed after tooth bleaching in the presence of a nickel-free metallic orthodontic bracket.


  • Open Access

    Role of enamel and dentin on color changes after internal bleaching associated or not with external bleaching

    by Tauan Rosa Santana, Rafaella Mariana Fontes de Bragança, Ana Claudia Conceição Correia, Isadora de Melo Oliveira, André Luis Faria-E-Silva

    Objective To evaluate the effect of the association between external and internal tooth bleaching on color changes in dentin and enamel, individually or recombined, previously stained with triple antibiotic paste (TAP). Methodology Forty enamel-dentin specimens from bovine incisors were separated into ten blocks according to similarity in their whiteness index (WID). Three specimens within each block were stained by dentin exposure to TAP, and the remaining specimen was used as control to estimate color changes. Specimens were sectioned to separate tissues, and dentin and enamel colors were measured individually and after being recombined. Alterations in color (CIEDE2000 - ΔE00) and translucency parameter (TP) resulting from staining were estimated by color difference between stained and control specimens. The contribution of each tissue to the color change (CTCC) was also calculated. Non-sectioned stained specimens were bleached by applying sodium perborate on dentin, associated or not with 35% hydrogen peroxide on enamel. Color changes caused by bleaching procedures were estimated and data were analyzed using the paired t-test or Two-way repeated measures ANOVA. Results TAP caused more pronounced changes in dentin, but enamel color was also affected. Both protocols presented a similar ΔE00, and dentin showed the greater color change. After exposure to TAP, we observed a reduction in WID; WID values were the same for bleached and control specimens regardless of protocol. We found no significant effect of substrate and bleaching technique on TP. Enamel played a more critical role in color changes caused by either staining or bleaching procedures. Conclusion Enamel color played a greater role on tooth color changes than dentin. External and internal bleaching association did not improve bleaching effect on specimens stained with TAP.