Philipp Schippers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Philipp Schippers has a total of 112 co-authors. Here are the top co-authors by number of shared publications:
- Pascal Boileau
Institut de Chirurgie Reparatrice (ICR) - Locomoteur & Sport, Institute for Reconstructive Surgery, Nice, France
8 shared publications - Philipp Drees
Department of Orthopedics and Traumatology, University Medical Center Mainz, 55131 Mainz, Germany
6 shared publications Erol Gercek
Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
5 shared publications- Gregorio Secci
Department of Orthopaedic Surgery, University of Florence, A.O.U. Careggi CTO, Largo Palagi 1, 50139, Florence, Italy
5 shared publications - Sebastian Fischer
Department of Foot and Ankle Surgery, Berufsgenossenschaftliche Unfallklinik Frankfurt am Main, Frankfurt, Germany
5 shared publications - Mark Mouchantaf
ICR-Institut de Chirurgie Réparatrice, Locomoteur & Sports, Nice, France
4 shared publications
Latest Publications
- Open Access
- 4 September 2026
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (10) , 2611-2619
Long-term results of a vitamin E–blended polyethylene liner in total hip arthroplasty: a minimum ten year computer aided design based evaluation of wear and component positioning
Background: Aseptic loosening remains a leading cause of revision in total hip arthroplasty (THA), with polyethylene wear representing a key contributing factor. Vitamin E–blended highly cross-linked polyethylene (VEPE) has been introduced to improve oxidative stability and long-term wear performance; however, long-term clinical data remain limited. Methods: This retrospective study evaluates long-term polyethylene wear and component positioning in a cohort of patients who underwent primary THA using a vitamin E–blended polyethylene monoblock acetabular component (RM Pressfit vitamys®). Patients were followed for a minimum of ten years. Radiographic assessment was performed using a fully automated, observer-independent CAD-based software (RayMatch®), enabling measurement of cup inclination, anteversion, and polyethylene wear through 2D–3D registration of implant CAD models. Results: A total of 57 hips with complete radiographic follow-up were analyzed. Mean polyethylene wear rates were 26.9 µm/year at five years and 18.2 µm/year at ten years, remaining well below commonly reported thresholds associated with osteolysis. Cup inclination remained stable over time, whereas a gradual increase in measured anteversion was observed during follow-up. Conclusion: At a minimum ten year follow-up, the investigated vitamin E–blended polyethylene monoblock cup demonstrated favorable long-term wear characteristics and stable component positioning. Further comparative studies are warranted to compare its long-term performance with other acetabular cup and liner designs.
- 4 September 2026
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (10) , 2611-2619
Open AccessLong-term results of a vitamin E–blended polyethylene liner in total hip arthroplasty: a minimum ten year computer aided design based evaluation of wear and component positioning
Background: Aseptic loosening remains a leading cause of revision in total hip arthroplasty (THA), with polyethylene wear representing a key contributing factor. Vitamin E–blended highly cross-linked polyethylene (VEPE) has been introduced to improve oxidative stability and long-term wear performance; however, long-term clinical data remain limited. Methods: This retrospective study evaluates long-term polyethylene wear and component positioning in a cohort of patients who underwent primary THA using a vitamin E–blended polyethylene monoblock acetabular component (RM Pressfit vitamys®). Patients were followed for a minimum of ten years. Radiographic assessment was performed using a fully automated, observer-independent CAD-based software (RayMatch®), enabling measurement of cup inclination, anteversion, and polyethylene wear through 2D–3D registration of implant CAD models. Results: A total of 57 hips with complete radiographic follow-up were analyzed. Mean polyethylene wear rates were 26.9 µm/year at five years and 18.2 µm/year at ten years, remaining well below commonly reported thresholds associated with osteolysis. Cup inclination remained stable over time, whereas a gradual increase in measured anteversion was observed during follow-up. Conclusion: At a minimum ten year follow-up, the investigated vitamin E–blended polyethylene monoblock cup demonstrated favorable long-term wear characteristics and stable component positioning. Further comparative studies are warranted to compare its long-term performance with other acetabular cup and liner designs.
- Open Access
- 10 February 2026
- Published by Elsevier in JSES International
- Vol. 10 (3) , 101655
How to measure humeral medialization and upward migration after shoulder hemiarthroplasty
- 10 February 2026
- Published by Elsevier in JSES International
- Vol. 10 (3) , 101655
Open AccessHow to measure humeral medialization and upward migration after shoulder hemiarthroplasty
- Open Access
- 1 January 2026
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 18 (3) , 439-448
Association of General Personality Traits with Outcomes in Total Hip Arthroplasty: A Multicenter, Cross-Sectional, Prospective Trial
Wunderlich F, et al. Clin Orthop Surg. 2026 Jun;18(3):439-448. https://doi.org/10.4055/cios25047
- 1 January 2026
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 18 (3) , 439-448
Open AccessAssociation of General Personality Traits with Outcomes in Total Hip Arthroplasty: A Multicenter, Cross-Sectional, Prospective Trial
Wunderlich F, et al. Clin Orthop Surg. 2026 Jun;18(3):439-448. https://doi.org/10.4055/cios25047
- Open Access
- 29 December 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (6) , 1409-1419
Survival and long-term (minimum 10-year) outcomes of bony increased-offset–reverse shoulder arthroplasty
- 29 December 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (6) , 1409-1419
Open AccessSurvival and long-term (minimum 10-year) outcomes of bony increased-offset–reverse shoulder arthroplasty
- Open Access
- 31 October 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (5) , 1230-1242
Patient-specific BIO-RSA (bony increased-offset reverse shoulder arthroplasty) for glenoid dysplasia (type C) osteoarthritis
- 31 October 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (5) , 1230-1242
Open AccessPatient-specific BIO-RSA (bony increased-offset reverse shoulder arthroplasty) for glenoid dysplasia (type C) osteoarthritis
- Open Access
- 7 August 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (2) , 421-437
Pyrocarbon hemiarthroplasty for the treatment of shoulder osteoarthritis in young, active patients: survival and risk factors for revision
- 7 August 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (2) , 421-437
Open AccessPyrocarbon hemiarthroplasty for the treatment of shoulder osteoarthritis in young, active patients: survival and risk factors for revision
- 5 August 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 35 (4) , 636-644
Can surgeons predict how much compensation is needed to correct glenoid inclination in reverse shoulder arthroplasty?
- 5 August 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 35 (4) , 636-644
Can surgeons predict how much compensation is needed to correct glenoid inclination in reverse shoulder arthroplasty?
- Open Access
- 5 April 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 35 (3) , 387-396
Outcomes of reverse shoulder arthroplasty in patients with os acromiale: a systematic review
- 5 April 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 35 (3) , 387-396
Open AccessOutcomes of reverse shoulder arthroplasty in patients with os acromiale: a systematic review
- 24 January 2025
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 51 (1) , 1-12
The misleading terminology of minor amputation of the lower limb
Purpose A pronounced loss of function of the lower limb of various origins, especially with an infection-related course, may require a minor (MIN) or major (MAJ) amputation of the lower limb. Our aim was to contrast the underlying etiology, including previous trauma, surgical procedure, and the subsequent function. Methods Between 2012 and 2022, 366 lower limb amputations were considered. After excluding isolated toe amputations and knee disarticulations, 80 amputations of 77 patients (66 male; 11 female; mean age: 57.2 years) were included in this monocentric retrospective study and their clinical outcome was evaluated. Briefly, 23 patients underwent MIN and 54 patients, including three bilateral cases, underwent MAJ. Patient demographics, etiology, level of amputation, prosthesis fitting, mobility based on the K-Level categories, SF-12 questionnaire, PLUS-M 12-item short form, and problems in coping with everyday life were recorded. The mean follow-up period was 3.9 years. Results The mean SF-12 score of all patients was 36.9 (MIN: 37.24; MAJ: 36.85) for the physical summary component and 50.0 (MIN: 52.32; MAJ: 48.46) for the mental summary component; the mean Plus-M 12 score was 49.5 (MIN: 50,08; MAJ: 48,46) (p > 0.05). K-level 3 was the most common in all patients (MIN: 47.8%, MAJ: 42.6%), defined as an unrestricted outdoor walker. Conclusion With MIN and MAJ results comparable in all scores and queries, it emphasizes the fact that even supposedly lower-limb MIN represents a considerable impairment of coping with daily life. If there is no prospect of preserving the limb, early transtibial amputation should be considered. However, our results support the good outcome despite lower-limb MAJ through modern prosthetic fitting.
- 24 January 2025
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 51 (1) , 1-12
The misleading terminology of minor amputation of the lower limb
Purpose A pronounced loss of function of the lower limb of various origins, especially with an infection-related course, may require a minor (MIN) or major (MAJ) amputation of the lower limb. Our aim was to contrast the underlying etiology, including previous trauma, surgical procedure, and the subsequent function. Methods Between 2012 and 2022, 366 lower limb amputations were considered. After excluding isolated toe amputations and knee disarticulations, 80 amputations of 77 patients (66 male; 11 female; mean age: 57.2 years) were included in this monocentric retrospective study and their clinical outcome was evaluated. Briefly, 23 patients underwent MIN and 54 patients, including three bilateral cases, underwent MAJ. Patient demographics, etiology, level of amputation, prosthesis fitting, mobility based on the K-Level categories, SF-12 questionnaire, PLUS-M 12-item short form, and problems in coping with everyday life were recorded. The mean follow-up period was 3.9 years. Results The mean SF-12 score of all patients was 36.9 (MIN: 37.24; MAJ: 36.85) for the physical summary component and 50.0 (MIN: 52.32; MAJ: 48.46) for the mental summary component; the mean Plus-M 12 score was 49.5 (MIN: 50,08; MAJ: 48,46) (p > 0.05). K-level 3 was the most common in all patients (MIN: 47.8%, MAJ: 42.6%), defined as an unrestricted outdoor walker. Conclusion With MIN and MAJ results comparable in all scores and queries, it emphasizes the fact that even supposedly lower-limb MIN represents a considerable impairment of coping with daily life. If there is no prospect of preserving the limb, early transtibial amputation should be considered. However, our results support the good outcome despite lower-limb MAJ through modern prosthetic fitting.
- Open Access
- 10 October 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 5 (10) , 851-857
Optimizing range of motion in reverse shoulder arthroplasty
Aims: Optimal glenoid positioning in reverse shoulder arthroplasty (RSA) is crucial to provide impingement-free range of motion (ROM). Lateralization and inclination correction are not yet systematically used. Using planning software, we simulated the most used glenoid implant positions. The primary goal was to determine the configuration that delivers the best theoretical impingement-free ROM.Methods: With the use of a 3D planning software (Blueprint) for RSA, 41 shoulders in 41 consecutive patients (17 males and 24 females; means age 73 years (SD 7)) undergoing RSA were planned. For the same anteroposterior positioning and retroversion of the glenoid implant, four different glenoid baseplate configurations were used on each shoulder to compare ROM: 1) no correction of the RSA angle and no lateralization (C-L-); 2) correction of the RSA angle with medialization by inferior reaming (C+M+); 3) correction of the RSA angle without lateralization by superior compensation (C+L-); and 4) correction of the RSA angle and additional lateralization (C+L+). The same humeral inlay implant and positioning were used on the humeral side for the four different glenoid configurations with a 3 mm symmetric 135° inclined polyethylene liner.Results: The configuration with lateralization and correction of the RSA angle (C+L+) led to better ROM in flexion, extension, adduction, and external rotation (p ≤ 0.001). Only internal rotation was not significantly different between groups (p = 0.388). The configuration where correction of the inclination was done by medialization (C+M+) led to the worst ROM in adduction, extension, abduction, flexion, and external rotation of the shoulder.Conclusion: Our software study shows that, when using a 135° inlay reversed humeral implant, correcting glenoid inclination (RSA angle 0°) and lateralizing the glenoid component by using an angled bony or metallic augment of 8 to 10 mm provides optimal impingement-free ROM.Cite this article: Bone Jt Open 2024;5(10):851–857.
- 10 October 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 5 (10) , 851-857
Open AccessOptimizing range of motion in reverse shoulder arthroplasty
Aims: Optimal glenoid positioning in reverse shoulder arthroplasty (RSA) is crucial to provide impingement-free range of motion (ROM). Lateralization and inclination correction are not yet systematically used. Using planning software, we simulated the most used glenoid implant positions. The primary goal was to determine the configuration that delivers the best theoretical impingement-free ROM.Methods: With the use of a 3D planning software (Blueprint) for RSA, 41 shoulders in 41 consecutive patients (17 males and 24 females; means age 73 years (SD 7)) undergoing RSA were planned. For the same anteroposterior positioning and retroversion of the glenoid implant, four different glenoid baseplate configurations were used on each shoulder to compare ROM: 1) no correction of the RSA angle and no lateralization (C-L-); 2) correction of the RSA angle with medialization by inferior reaming (C+M+); 3) correction of the RSA angle without lateralization by superior compensation (C+L-); and 4) correction of the RSA angle and additional lateralization (C+L+). The same humeral inlay implant and positioning were used on the humeral side for the four different glenoid configurations with a 3 mm symmetric 135° inclined polyethylene liner.Results: The configuration with lateralization and correction of the RSA angle (C+L+) led to better ROM in flexion, extension, adduction, and external rotation (p ≤ 0.001). Only internal rotation was not significantly different between groups (p = 0.388). The configuration where correction of the inclination was done by medialization (C+M+) led to the worst ROM in adduction, extension, abduction, flexion, and external rotation of the shoulder.Conclusion: Our software study shows that, when using a 135° inlay reversed humeral implant, correcting glenoid inclination (RSA angle 0°) and lateralizing the glenoid component by using an angled bony or metallic augment of 8 to 10 mm provides optimal impingement-free ROM.Cite this article: Bone Jt Open 2024;5(10):851–857.