Tetsuichi Kishishita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tetsuichi Kishishita has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
- Masayoshi Shoji
Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), 1-1 Oho
6 shared publications - Eitaro Hamada
Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), 1-1 Oho
5 shared publications - Kazutoshi Kojima
National Institute of Advanced Industrial Science and Technology (AIST)
5 shared publications Manobu M. Tanaka
Institute of Particle and Nuclear Studies, KEK, High Energy Accelerator Research Organization, Tsukuba, Japan
5 shared publications- Yasunori Tanaka
National Institute of Advanced Industrial Science and Technology (AIST)
4 shared publications - Yowichi Fujita
KEK, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan
4 shared publications
Latest Publications
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (2) , 276-281
A Fast p-n Junction SiC Detector for Heavy-Ion Applications
Radiation sensors based on silicon carbide (SiC) are promising candidates for next-generation detectors capable of operating in harsh environments. However, their response to highly ionizing heavy-ion beams remains inadequately characterized. To evaluate the feasibility of using SiC detectors in nuclear physics experiments, particularly for detecting radioactive ion beam particles at relativistic energies, we conducted beam irradiation tests at heavy-ion accelerator facilities. These tests were designed to assess detector performance through ion-induced transient responses and time resolution measurements. A recently developed 4H-SiC detector with a pixelated pn-junction structure was employed. The detector’s transient response to heavy-ion implantation of 40Ar and 18O, with energy depositions up to 240MeV, was successfully observed. Efficient and rapid charge collection enabled signal detection without external amplification. The results also demonstrated excellent timing performance, achieving a time resolution of 71 ps FWHM for heavy ions. The measured performance meets the requirements for their application as time-of-flight detectors at in-flight radioactive beam facilities, thereby demonstrating the feasibility of employing SiC detectors.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (2) , 276-281
A Fast p-n Junction SiC Detector for Heavy-Ion Applications
Radiation sensors based on silicon carbide (SiC) are promising candidates for next-generation detectors capable of operating in harsh environments. However, their response to highly ionizing heavy-ion beams remains inadequately characterized. To evaluate the feasibility of using SiC detectors in nuclear physics experiments, particularly for detecting radioactive ion beam particles at relativistic energies, we conducted beam irradiation tests at heavy-ion accelerator facilities. These tests were designed to assess detector performance through ion-induced transient responses and time resolution measurements. A recently developed 4H-SiC detector with a pixelated pn-junction structure was employed. The detector’s transient response to heavy-ion implantation of 40Ar and 18O, with energy depositions up to 240MeV, was successfully observed. Efficient and rapid charge collection enabled signal detection without external amplification. The results also demonstrated excellent timing performance, achieving a time resolution of 71 ps FWHM for heavy ions. The measured performance meets the requirements for their application as time-of-flight detectors at in-flight radioactive beam facilities, thereby demonstrating the feasibility of employing SiC detectors.
- 1 February 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (02) , C02034
Development of low temperature electronics for LAr-TPC
Recently, the multi-kton Liquid Argon Time Projection Chamber (LAr-TPC) has been developed to conduct neutrino oscillation and nucleon decay search experiments. Accordingly, the necessity of high functional electronics for the multi-kton LAr-TPC has been increasing. The electronics used in LAr-TPC is needed to operate stably at cryogenic temperature (89 K). Thus, we have been developing analog front-end electronics for LAr-TPC termed as LTARS, and making improvements. The latest version of this electronics in the LTARS series, LTAR16A, is fabricated in a TSMC 180 nm process. The ASIC includes on board the following features: A/D converters, internal and external trigger modes and two data processing modes. We tested the LTARS16A and confirmed that the performance satisfies our requirements for both at room and cryogenic temperatures. Furthermore, we successfully observed the output signal for α-rays with the LTARS16A mounted on a small-sized prototype TPC.
- 1 February 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (02) , C02034
Development of low temperature electronics for LAr-TPC
Recently, the multi-kton Liquid Argon Time Projection Chamber (LAr-TPC) has been developed to conduct neutrino oscillation and nucleon decay search experiments. Accordingly, the necessity of high functional electronics for the multi-kton LAr-TPC has been increasing. The electronics used in LAr-TPC is needed to operate stably at cryogenic temperature (89 K). Thus, we have been developing analog front-end electronics for LAr-TPC termed as LTARS, and making improvements. The latest version of this electronics in the LTARS series, LTAR16A, is fabricated in a TSMC 180 nm process. The ASIC includes on board the following features: A/D converters, internal and external trigger modes and two data processing modes. We tested the LTARS16A and confirmed that the performance satisfies our requirements for both at room and cryogenic temperatures. Furthermore, we successfully observed the output signal for α-rays with the LTARS16A mounted on a small-sized prototype TPC.
- Open Access
- 1 February 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (02) , C02016
Prototype of SiC beam monitor for the COMET experiment at J-PARC
We have developed a prototype of the muon beam monitor (μBM) for the COMET experiment at J-PARC. The COMET aims to search for the neutrino-less muon-to-electron conversion event in the field of the nucleus, as a charged lepton flavor violation process. The SiC-based μBM will be installed in a vacuum chamber and located in front of the muon-stopping target and the main central drift chamber. The detector consists of SiC PN-diodes and dedicated readout electronics. By tailing the 256 sensors in a matrix, the beam profile and bunch stability can be extracted, and then, are utilized for the background estimation of the rare process. To validate the μBM concept, we implemented the SiC sensors on the prototype Kapton-flex sensor board and conducted a beam test at J-PARC. The pulse height of μ-events in the SiC sensor was linearly correlated with an averaged coincidence of the decayed electrons by scintillators. We thus conclude that the number of incident muons can be estimated from the pulse height information from the μBM. The radiation tolerance of the sensor was also proven to be sufficient for the COMET Phase-1 by irradiating fast neutrons with 1.7×1012/ cm2 fluence at research nuclear reactor. The electronics designed in 65 nm CMOS is currently under testing. In the lab.-testing, we confirmed the basic functionality as a required waveform digitizer and sufficient signal-integrity to drive the 10 m cable length to the backend electronics.
- 1 February 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (02) , C02016
Open AccessPrototype of SiC beam monitor for the COMET experiment at J-PARC
We have developed a prototype of the muon beam monitor (μBM) for the COMET experiment at J-PARC. The COMET aims to search for the neutrino-less muon-to-electron conversion event in the field of the nucleus, as a charged lepton flavor violation process. The SiC-based μBM will be installed in a vacuum chamber and located in front of the muon-stopping target and the main central drift chamber. The detector consists of SiC PN-diodes and dedicated readout electronics. By tailing the 256 sensors in a matrix, the beam profile and bunch stability can be extracted, and then, are utilized for the background estimation of the rare process. To validate the μBM concept, we implemented the SiC sensors on the prototype Kapton-flex sensor board and conducted a beam test at J-PARC. The pulse height of μ-events in the SiC sensor was linearly correlated with an averaged coincidence of the decayed electrons by scintillators. We thus conclude that the number of incident muons can be estimated from the pulse height information from the μBM. The radiation tolerance of the sensor was also proven to be sufficient for the COMET Phase-1 by irradiating fast neutrons with 1.7×1012/ cm2 fluence at research nuclear reactor. The electronics designed in 65 nm CMOS is currently under testing. In the lab.-testing, we confirmed the basic functionality as a required waveform digitizer and sufficient signal-integrity to drive the 10 m cable length to the backend electronics.
- Open Access
- 14 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 35-40
FPGA-based detector with SiC sensing for real-time monitoring of muon beams
This article reports the development of a muon monitoring system that utilizes SiC p+n junction diodes as the primary sensing element, integrated with FPGAs for signal processing and control. The system will be designed to detect muons, which are subatomic particles that penetrate deep into materials and have applications in various fields such as particle physics, geology, and radiography. The use of SiC p+n junction diodes is advantageous due to their high radiation hardness, fast response time, and low noise characteristics, which make them well-suited for high-energy particle detection. The FPGAs will provide real-time signal processing capabilities, enabling efficient data analysis and monitoring. This FPGA-based detector system has the potential to provide a cost-effective and reliable solution for muon monitoring applications.
- 14 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 35-40
Open AccessFPGA-based detector with SiC sensing for real-time monitoring of muon beams
This article reports the development of a muon monitoring system that utilizes SiC p+n junction diodes as the primary sensing element, integrated with FPGAs for signal processing and control. The system will be designed to detect muons, which are subatomic particles that penetrate deep into materials and have applications in various fields such as particle physics, geology, and radiography. The use of SiC p+n junction diodes is advantageous due to their high radiation hardness, fast response time, and low noise characteristics, which make them well-suited for high-energy particle detection. The FPGAs will provide real-time signal processing capabilities, enabling efficient data analysis and monitoring. This FPGA-based detector system has the potential to provide a cost-effective and reliable solution for muon monitoring applications.
- Open Access
- 17 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (6) , 1210-1214
Hybrid SiC Pixel Detector for Charged-Particle Beam Monitor
We report on the hybrid SiC pixel detector for charged-particle beam monitors in high-energy physics experiments. To demonstrate comparable performances of the state-of-the-art Si pixel detectors, SiC pixel sensors with a die size of 25 mm 2 were fabricated based on the p-n diode structure. We combined 12 × 12 diodes of a pixel size of 160 μm and 270 μm pitch with the dedicated readout ASIC by In/Au stud-bump technology. The front-end chip was designed in 0.35 μm CMOS technology, with consideration of a hybrid configuration. Each pixel circuit consists of a charge-sensitive amplifier and band-pass filter, optimized for the SiC sensor. The low noise performance achieved an equivalent noise charge of 55 ± 5e – (rms). The spectrum of 241 Am shows an energy resolution of 1.72 keV (FWHM) at 17.8 keV γ-rays at room temperature. The obtained image with 90 Sr is a proof of a single MIP detection capability with all pixels. Those results prospect a future application of the SiC pixel sensors to high-intensity proton extinction monitors in the COMET muon experiment at Japan Proton Accelerator Research Complex.
- 17 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (6) , 1210-1214
Open AccessHybrid SiC Pixel Detector for Charged-Particle Beam Monitor
We report on the hybrid SiC pixel detector for charged-particle beam monitors in high-energy physics experiments. To demonstrate comparable performances of the state-of-the-art Si pixel detectors, SiC pixel sensors with a die size of 25 mm 2 were fabricated based on the p-n diode structure. We combined 12 × 12 diodes of a pixel size of 160 μm and 270 μm pitch with the dedicated readout ASIC by In/Au stud-bump technology. The front-end chip was designed in 0.35 μm CMOS technology, with consideration of a hybrid configuration. Each pixel circuit consists of a charge-sensitive amplifier and band-pass filter, optimized for the SiC sensor. The low noise performance achieved an equivalent noise charge of 55 ± 5e – (rms). The spectrum of 241 Am shows an energy resolution of 1.72 keV (FWHM) at 17.8 keV γ-rays at room temperature. The obtained image with 90 Sr is a proof of a single MIP detection capability with all pixels. Those results prospect a future application of the SiC pixel sensors to high-intensity proton extinction monitors in the COMET muon experiment at Japan Proton Accelerator Research Complex.
- Open Access
- 3 April 2023
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 60 (10) , 1285-1291
A membrane, pseudo-vertical p-i-n diamond detector
We report on the membrane diamond detector, which consists of 5 µm-thick p-i-n diodes and a dedicated front-end ASIC, fabricated in a 65-nm CMOS technology. The p-i-n diode has an attractive feature for low -ray sensitivities due to its extremely thin drift layer, which is difficult to form by etching of bulk diamond with a Metal−Insulator−Metal structure. The pseudo-vertical p-i-n diode structure was formed on the single crystal diamond {111} substrate by MPCVD and dry-etching process. The readout electronics was designed to meet specifications for real-time neutron monitoring in harsh -ray environments. The prototype system was evaluated in charge distribution measurements induced by -particles from Am. The charge spectra were successfully obtained from multi-channels, each of which has a diameter of 250 µm aligning in a pixel matrix. By combining with neutron converters, e.g. B or Li, we expect the detector system as a good candidate for detecting spontaneous fission neutrons, emitted from submerged fuel debris at the Fukushima Daiichi Nuclear Power Plant in Japan.- 3 April 2023
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 60 (10) , 1285-1291
Open AccessA membrane, pseudo-vertical p-i-n diamond detector
We report on the membrane diamond detector, which consists of 5 µm-thick p-i-n diodes and a dedicated front-end ASIC, fabricated in a 65-nm CMOS technology. The p-i-n diode has an attractive feature for low -ray sensitivities due to its extremely thin drift layer, which is difficult to form by etching of bulk diamond with a Metal−Insulator−Metal structure. The pseudo-vertical p-i-n diode structure was formed on the single crystal diamond {111} substrate by MPCVD and dry-etching process. The readout electronics was designed to meet specifications for real-time neutron monitoring in harsh -ray environments. The prototype system was evaluated in charge distribution measurements induced by -particles from Am. The charge spectra were successfully obtained from multi-channels, each of which has a diameter of 250 µm aligning in a pixel matrix. By combining with neutron converters, e.g. B or Li, we expect the detector system as a good candidate for detecting spontaneous fission neutrons, emitted from submerged fuel debris at the Fukushima Daiichi Nuclear Power Plant in Japan. - Open Access
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (12) , 2787-2793
SiC p+n Junction Diodes Toward Beam Monitor Applications
We report on silicon carbide (SiC) p-n junction diodes with a high blocking voltage over 3 kV. Although SiC radiation sensors have been developed with a Schottky barrier type due to a simple fabrication process in the early stages, p-n junction structures are advantageous due to lower sensitivity of the surface defects. Thus, this system provides an ideal condition to investigate the effect of bulk crystal defects on the characteristics of the radiation sensor. The p-n diodes were designed with a device simulator and fabricated with a 4-in 4H-SiC wafer. The epitaxial layer was grown on an n-type substrate with sufficiently low doping concentration of ${N_{\mathrm{ d}}} - {N_{\mathrm{ a}}}=\sim 5\times 10^{14} {\mathrm{ cm}}^{-3}$ and an average thickness of $52 ~\mu {\mathrm{ m}}$ . Fabricated p-n diodes with a relatively large leakage current still show a clear peak of the Landau distribution in the charge spectrum, suggesting their practical availability as minimum ionizing particle (MIP) detectors. The estimated electron–hole pair creation energy is consistent with the published studies and we expect good radiation tolerance. Feasibility based on the wafer processing indicates that the prototype devices are a good candidate for the muon beam monitor application in the COherent Muon-to-Electron Transition (COMET) experiment at Japan Proton Accelerator Research Complex (J-PARC).
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (12) , 2787-2793
Open AccessSiC p+n Junction Diodes Toward Beam Monitor Applications
We report on silicon carbide (SiC) p-n junction diodes with a high blocking voltage over 3 kV. Although SiC radiation sensors have been developed with a Schottky barrier type due to a simple fabrication process in the early stages, p-n junction structures are advantageous due to lower sensitivity of the surface defects. Thus, this system provides an ideal condition to investigate the effect of bulk crystal defects on the characteristics of the radiation sensor. The p-n diodes were designed with a device simulator and fabricated with a 4-in 4H-SiC wafer. The epitaxial layer was grown on an n-type substrate with sufficiently low doping concentration of ${N_{\mathrm{ d}}} - {N_{\mathrm{ a}}}=\sim 5\times 10^{14} {\mathrm{ cm}}^{-3}$ and an average thickness of $52 ~\mu {\mathrm{ m}}$ . Fabricated p-n diodes with a relatively large leakage current still show a clear peak of the Landau distribution in the charge spectrum, suggesting their practical availability as minimum ionizing particle (MIP) detectors. The estimated electron–hole pair creation energy is consistent with the published studies and we expect good radiation tolerance. Feasibility based on the wafer processing indicates that the prototype devices are a good candidate for the muon beam monitor application in the COherent Muon-to-Electron Transition (COMET) experiment at Japan Proton Accelerator Research Complex (J-PARC).
- 1 June 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (06) , T06002
Prototype of simultaneous bidirectional data-transmitter in 65 nm CMOS
This article presents a design and implementation of an I/O circuit block capable of simultaneous bidirectional data-transmission in CMOS integrated circuits. Merging data-transmitter and receiver into common bonding pad is feasible not only to reduce the number of transmission lines from a considerable number of chips, but also to realize more area-efficient data handling in consequence of flexible inter-chip communication. This feature is attractive from the viewpoint of detector systems in high energy experiments, in which reducing materials such as cables from silicon trackers in inner vertex layers is of major importance to suppress multiple-scattering and to achieve good overall detector performances. The circuit block presented here is designed on the basis of a current subtraction circuit and two distinct current-mode logic drivers. Its principle is also applicable to widely-used low-voltage differential signal drivers and easy for process migration. The prototype chip was fabricated in a 65 nm CMOS technology. Working principle has been demonstrated in preliminary laboratory testing.
- 1 June 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (06) , T06002
Prototype of simultaneous bidirectional data-transmitter in 65 nm CMOS
This article presents a design and implementation of an I/O circuit block capable of simultaneous bidirectional data-transmission in CMOS integrated circuits. Merging data-transmitter and receiver into common bonding pad is feasible not only to reduce the number of transmission lines from a considerable number of chips, but also to realize more area-efficient data handling in consequence of flexible inter-chip communication. This feature is attractive from the viewpoint of detector systems in high energy experiments, in which reducing materials such as cables from silicon trackers in inner vertex layers is of major importance to suppress multiple-scattering and to achieve good overall detector performances. The circuit block presented here is designed on the basis of a current subtraction circuit and two distinct current-mode logic drivers. Its principle is also applicable to widely-used low-voltage differential signal drivers and easy for process migration. The prototype chip was fabricated in a 65 nm CMOS technology. Working principle has been demonstrated in preliminary laboratory testing.
- Open Access
- 25 March 2021
- Published by Physical Society of Japan
Positron Tracking Detector for Muon g − 2/EDM Experiment at J-PARC
- 25 March 2021
- Published by Physical Society of Japan
Open AccessPositron Tracking Detector for Muon g − 2/EDM Experiment at J-PARC