Valeri Ayvazyan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Valeri Ayvazyan has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Julien Branlard
Deutsches Elektronen-Synchrotron DESY
2 shared publications - Radoslaw Rybaniec
Deutsches Elektronen-Synchrotron, Hamburg, Notkestrasse 85, 22-607 Germany
2 shared publications - Sven Pfeiffer
Deutsches Elektronen-Synchrotron DESY, Hamburg, Germany
2 shared publications - Wojciech Cichalewski
Lodz University of Technology,Department of Microelectronics and Computer Science,Lodz,Poland
2 shared publications Alexey Sulimov
1 shared publication- Andrea Bellandi
Deutsches Elektronen-Synchrotron, Hamburg 22607, Germany
1 shared publication
Latest Publications
- Open Access
RF regulation with superconducting cavities and beam operation using a frequency shifted cavity
The free-electron laser FLASH at DESY and the European XFEL are operated with superconducting radio frequency cavities and supply beam to several user experiments. The switching time between experiments is limited to dozens of microseconds. This contribution will show a regulation with a frequency shifted superconducting cavity to manipulate and change the accelerating properties of electron bunches with 250 kHz.The main challenge of the concept presented in this contribution can be summarized in this statement: finding a way to modulate the energy of individual bunches in a single-source multiple-cavity scheme for a potential CW upgrade of the EuXFEL.
Open AccessRF regulation with superconducting cavities and beam operation using a frequency shifted cavity
The free-electron laser FLASH at DESY and the European XFEL are operated with superconducting radio frequency cavities and supply beam to several user experiments. The switching time between experiments is limited to dozens of microseconds. This contribution will show a regulation with a frequency shifted superconducting cavity to manipulate and change the accelerating properties of electron bunches with 250 kHz.The main challenge of the concept presented in this contribution can be summarized in this statement: finding a way to modulate the energy of individual bunches in a single-source multiple-cavity scheme for a potential CW upgrade of the EuXFEL.
- 8 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (9) , 2119-2127
Continuous Wave Operation of Superconducting Accelerating Cavities With High Loaded Quality Factor
Close to 780 superconducting 1.3 GHz accelerating cavities made of bulk niobium have been installed in the European X-ray Free Electron Laser (E-XFEL) linear accelerator. The linac can operate at a mean gradient (Eacc) of ca. 23 MV/m in the nominal short pulse (SP) operation mode with 1.4 ms pulses and a repetition rate of 10 Hz. An R&D program at DESY is ongoing since 2011 on the feasibility of a continuous wave (CW) upgrade of the E-XFEL accelerator. In this publication, a modification of the Low Level Radio Frequency (LLRF) control system to the CW mode is presented. Currently, the control system successfully stabilizes accelerating field for the SP mode. The demanding EXFEL specifications of 0.01% for the field amplitude and 0.01° for the phase stability is required to keep the photon beam quality for all experimental stations. The proposed modification has been implemented and tested to verify the system versatility for SP and CW operation modes. The tests were conducted for a prototype E-XFEL cryomodule XM-3. As for the series cryomodules, this prototype contains 8 superconducting 1.3 GHz cavities. The results presented here confirm that the same LLRF system can be used with minor software modifications for either operation mode (CW or SP). However, the CW mode requires a more complex RF-power management and more precise control, especially when cavities operate with very high loaded quality factor (Ql) of the order of 6E7. The achieved stability for such high Ql is also presented and discussed.
- 8 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (9) , 2119-2127
Continuous Wave Operation of Superconducting Accelerating Cavities With High Loaded Quality Factor
Close to 780 superconducting 1.3 GHz accelerating cavities made of bulk niobium have been installed in the European X-ray Free Electron Laser (E-XFEL) linear accelerator. The linac can operate at a mean gradient (Eacc) of ca. 23 MV/m in the nominal short pulse (SP) operation mode with 1.4 ms pulses and a repetition rate of 10 Hz. An R&D program at DESY is ongoing since 2011 on the feasibility of a continuous wave (CW) upgrade of the E-XFEL accelerator. In this publication, a modification of the Low Level Radio Frequency (LLRF) control system to the CW mode is presented. Currently, the control system successfully stabilizes accelerating field for the SP mode. The demanding EXFEL specifications of 0.01% for the field amplitude and 0.01° for the phase stability is required to keep the photon beam quality for all experimental stations. The proposed modification has been implemented and tested to verify the system versatility for SP and CW operation modes. The tests were conducted for a prototype E-XFEL cryomodule XM-3. As for the series cryomodules, this prototype contains 8 superconducting 1.3 GHz cavities. The results presented here confirm that the same LLRF system can be used with minor software modifications for either operation mode (CW or SP). However, the CW mode requires a more complex RF-power management and more precise control, especially when cavities operate with very high loaded quality factor (Ql) of the order of 6E7. The achieved stability for such high Ql is also presented and discussed.
- 16 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (5) , 762-767
Results on FPGA-Based High-Power Tube Amplifier Linearization at DESY
Vacuum tube amplifiers are the most widespread type of Radio Frequency (RF) sources used to produce high power signals needed for beam acceleration in superconducting cavities. At Deutsches Elektronen-Synchrotron (DESY), megawatt rated klystrons are used to produce millisecond-long RF shots for pulsed operation in particle accelerators. In contrast, inductive output tubes are used to provide a continuous RF signal for Continuous Wave (CW) operation. In both cases, the amplifiers suffer from amplitude dependent nonlinearity between the driving and generated signals. This nonlinearity complicates the setup operations of the Low Level RF (LLRF) system and makes it harder to regulate the accelerating field. Therefore a way to linearize the amplifier is highly valuable. This paper covers the design, implementation, and test of an FPGA-based predistortion linearization unit. The first results on the performance of this component in linearizing the amplifiers of running CW and pulsed superconducting accelerators are presented. Such a component uses programmable interpolating Look Up Tables (LUT) that are addressed using the squared value of the requested signal amplitude. This component only adds 64 ns latency to the RF control system without relying on any vendor-dependent FPGA component. Other benefits of using programmable interpolating LUT are low FPGA usage of FPGA resources and flexibility in terms of the type of amplifier to be corrected. The benefits of using this linearizer for klystrons and inductive output tubes are presented and quantified.
- 16 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (5) , 762-767
Results on FPGA-Based High-Power Tube Amplifier Linearization at DESY
Vacuum tube amplifiers are the most widespread type of Radio Frequency (RF) sources used to produce high power signals needed for beam acceleration in superconducting cavities. At Deutsches Elektronen-Synchrotron (DESY), megawatt rated klystrons are used to produce millisecond-long RF shots for pulsed operation in particle accelerators. In contrast, inductive output tubes are used to provide a continuous RF signal for Continuous Wave (CW) operation. In both cases, the amplifiers suffer from amplitude dependent nonlinearity between the driving and generated signals. This nonlinearity complicates the setup operations of the Low Level RF (LLRF) system and makes it harder to regulate the accelerating field. Therefore a way to linearize the amplifier is highly valuable. This paper covers the design, implementation, and test of an FPGA-based predistortion linearization unit. The first results on the performance of this component in linearizing the amplifiers of running CW and pulsed superconducting accelerators are presented. Such a component uses programmable interpolating Look Up Tables (LUT) that are addressed using the squared value of the requested signal amplitude. This component only adds 64 ns latency to the RF control system without relying on any vendor-dependent FPGA component. Other benefits of using programmable interpolating LUT are low FPGA usage of FPGA resources and flexibility in terms of the type of amplifier to be corrected. The benefits of using this linearizer for klystrons and inductive output tubes are presented and quantified.