LVLudo Vermeeren

Ludo Vermeeren

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ludo Vermeeren has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Nuclear Heating Measurements by Gamma and Neutron Thermometers

    by R. Van Nieuwenhove, L. Vermeeren

    A gamma thermometer suitable for very high gamma heating levels (up to 20 W/g) has been designed and modelled by means of detailed finite element calculations. Based on a sensitivity analysis, the predicted accuracy of this gamma thermometer is better than 5 %. Experimental verification of the time constants has been performed, showing excellent agreement. A novel miniaturized gamma thermometer is proposed in which a single thermocouple is used as the gamma absorption element, allowing a reduction of the sensor diameter down to 3 mm. The sensitivities of the gamma thermometers with stainless steel, W, Mo and Rh as heated materials have been modelled by finite element calculations. It is found that both the Mo and the Rh based sensor have a very linear response up to a nuclear heating of 20 W/g. Monte Carlo calculations (by MCNP) have been performed to assess the relative contribution of neutrons to the nuclear heating in a gamma thermometer. Calculations have been performed for gamma thermometers with an inner body made of various materials, such as stainless steel, tungsten, molybdenum and rhodium. By using gamma thermometers made of different materials, it will be possible to deduce the nuclear heating rates in these materials and also to separate out the neutron and gamma heating contributions. The Monte Carlo calculations show that nuclear heating of rhodium is mainly due to neutrons, converting the rhodium gamma thermometer effectively in a neutron thermometer.


  • Open Access

    THERMOCOAX rhodium SPND sensitivity dispersion and validation of the sensitivity calculation model

    by L. Vermeeren, W. Leysen, L. Pichon, V. Salou, G. Helleux

    This paper describes the neutron irradiation tests of 7 THERMOCOAX Self-Powered Neutron detectors (SPNDs) in the BR1 reactor at SCK•CEN. The SPNDs were fabricated according to the same specifications, but from different fabrication batches. The SPND signals were recorded during stepwise power-up of the reactor, proving the linearity of the SPND response within a wide thermal neutron flux range: from as low as 0.8·109 n/(cm2) to 2.6·1011 n/(cm2s). Intercomparison of the SPND signals shows a very small spread, confirming the repeatability of the THERMOCOAX fabrication processes. The overall neutron sensitivities of the seven SPNDs agreed within a 1% margin. The experimental data were analyzed in terms of prompt and various delayed responses. Prompt contributions to the signal are due to external gamma induced processes and to processes involving gamma rays emitted instantaneously upon neutron capture. The main contribution in a rhodium SPND is due to activation of the rhodium emitter and beta emission during decay of the activated rhodium and leads to a delayed response with a characteristic time of a few minutes. Activation and subsequent beta decay in other materials present in the SPND lead to additional minor delayed signal contributions. The partial SPND sensitivities due to all these processes were calculated using an MCNPX based model and were compared with experimental sensitivities based on the recorded data. The results were in fair agreement; for the overall SPND neutron sensitivity an agreement within a 1% margin was achieved.


  • Open Access

    In-Pile Qualification of a Fast-Neutron-Detection-System

    by D. Fourmentel, J-F. Villard, C. Destouches, L. Barbot, B. Geslot, L. Vermeeren, M. Schyns

    In order to ensure the quality and the relevance of irradiation programs in the future Jules Horowitz Reactor (JHR), the French Alternative Energies and Atomic Energy Commission (CEA) has significantly increased its research and development effort in the field of in-pile instrumentation during the last decade. Major progress has been achieved in the capability to perform accurate in-pile measurements using reliable and updated techniques. A significant part of this effort has been conducted in the framework of the Joint Instrumentation Laboratory between the CEA and the Belgian Nuclear Research Centre (SCK · CEN). In order to improve measurement techniques for neutron flux assessment, a unique system for online measurement of fast neutron flux has been developed and recently qualified in-pile. The fast-neutron-detection-system (FNDS) has been designed to monitor accurately high-energy neutron flux (E > 1 MeV) in typical material testing reactor (MTR) conditions, where neutron flux levels can be as high as 10 15 N · cm -2 · s -1 and are generally dominated by thermal neutrons. Moreover, the neutron flux is coupled with a high gamma flux of typically a few 10 15 γ · cm -2 · s -1 , which can be highly disturbing for the online measurement of neutron fluxes. The patented FNDS system is based on two detectors allowing the simultaneous detection of both thermal- and fast-neutron flux. Thermal neutrons can be measured using a self-powered neutron detector or a 235 U miniature fission chamber, while fast neutron detection requires a miniature fission chamber with a special fissile material presenting an energy threshold near 1 MeV, which can be 242 Pu for MTR conditions. Fission chambers are operated in Campbelling mode for an efficient gamma rejection. FNDS also includes a specific software that processes measurements to compensate online the fissile material depletion and to adjust the sensitivity of the detectors, in order to produce a precise evaluation of both thermal and fast neutron flux even after longterm irradiation. FNDS has been validated through a two-step experimental program. A first set of tests was performed at BR2 reactor operated by SCK· CEN in Belgium. Two FNDS prototypes were operated in-pile during nearly 1000 h. These tests exhibited the consistency of the measurement of thermal to fast neutron flux ratio with Monte Carlo neutron and photon transport calculations, as well as the right compensation of fissile material depletion. This paper describes a second test recently completed at ISIS reactor operated by CEA in France. For this irradiation, FNDS signal was compared to reference thermaland fast-neutron flux measurements using activation dosimeters analyzed under COFRAC Quality Certification. During thislatter test, FNDS proved its ability to measure online the fast neutron flux with an overall accuracy better than 5%. FNDS is now operational and is assumed to be the first and unique acquisition system able to provide an online measurement of the fast neutron flux in MTR conditions. This system will be used to perform spectral neutron characterization of JHR channels, but it may also be implemented in future irradiation experiments, for a better and real-time evaluation of the fast neutron flux received by material and fuel samples.


  • Laser ion source for the Leuven Isotope Separator On-Line

    by Yu. A. Kudryavtsev, J. Andrzejewski, N. Bijnens, S. Franchoo, M. Huyse, A. Piechaczek, J. Szerypo, I. Reusen, P. Van Duppen, L. Vermeeren, et al.

    An on‐line laser ion source has been developed and coupled to an on‐line isotope separator for the production of isotopically and isobarically pure beams of radioactive ions. It is based on element‐selective resonant laser ionization of nuclear reaction products thermalized and neutralized in a high‐pressure noble gas after their recoil out of the target. Pure beams of 54,55Ni and 54Co, produced in a light‐ion‐induced fusion‐evaporation reaction, and of 113Rh, produced in a proton‐induced fission of 238U, were obtained. A preliminary efficiency of the ion source of ∼6% for fusion reactions and of ∼0.2% for fission reactions has been obtained. A selectivity of the ion source of 300 for fusion and 50 for fission reactions limited by the evacuation of non‐neutralized reaction products has been achieved.


  • Open Access

    Spin, moments, and mean square nuclear charge radius ofSr77

    by P. Lievens, L. Vermeeren, R. E. Silverans, E. Arnold, R. Neugart, K. Wendt, F. Buchinger

    The neutron deficient Sr77 nucleus was studied by fast ion beam collinear laser spectroscopy with a detection scheme based on optical pumping, state selective neutralization, and atom counting. From the measured hyperfine splitting and isotope shift of the Sr II transition 5s 2 S1/2→5p 2 P3/2 the nuclear spin I=5/2, the nuclear moments μ=-0.348(4)μN, Qs=1.40(11) b, and the change in mean square charge radius δ〈r2 〉88,77=0.248(12) fm2 were deduced. These ground-state properties indicate a large prolate deformation of ε2≃0.4 and allow a comparison with calculations performed in the particle-plus-deformed-core model, assigning a [422]5/2 Nilsson configuration to the ground state of Sr77.