JLJia-Cai Li

Jia-Cai Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jia-Cai Li has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessment Parameters for Arrayed Pulse Wave Analysis and Application in Hypertensive Disorders

    by Zi-Juan Bi, Xing-Hua Yao, Xiao-Juan Hu, Pei Yuan, Xiao-Jing Guo, Zhi-Ling Guo, Si-Han Wang, Jun Li, Yu-Lin Shi, Jia-Cai Li, et al.

    Study on the objectivity of pulse diagnosis is inseparable from the instruments to obtain the pulse waves. The single-pulse diagnostic instrument is relatively mature in acquiring and analysing pulse waves, but the pulse information captured by single-pulse diagnostic instrument is limited. The sensor arrays can simulate rich sense of the doctors fingers and catch multipoint and multiparameter array signals. How to analyse the acquired array signals is still a major problem in the objective research of pulse diagnosis. The goal of this study was to establish methods for analysing arrayed pulse waves and preliminarily apply them in hypertensive disorders. While a sensor array can be used for the real-time monitoring of twelve pulse wave channels, for each subject in this study, only the pulse wave signals of the left hand at the guan location were obtained. We calculated the average pulse wave (APW) per channel over a thirty-second interval. The most representative pulse wave (MRPW) and the APW were matched by their correlation coefficient (CC). The features of the MRPW and the features that corresponded to the array pulse volume (APV) parameters were identified manually. Finally, a clinical trial was conducted to detect these feature performance indicators in patients with hypertensive disorders. The independent-samples t-tests and the MannWhitney U-tests were performed to assess the differences in these pulse parameters between the healthy and hypertensive groups. We found that the radial passage (RP) APVh1, APVh3, APVh4, APVh3/h1 (Ph4/h1 (Ph4, APVh3/h1 (Ph4/h1 (Phe mean APVh3, APVh3/h1 (Ph4/h1 (Ph4/h1 (P<0.05) was clearly elevated in the hypertensive group. These results provide a preliminary validation of this novel approach for determining the APV by arrayed pulse wave analysis. In conclusion, we identified effective indicators of hypertensive vascular function. Traditional Chinese medicine (TCM) pulses comprise multidimensional information, and a sensor array could provide a better indication of TCM pulse characteristics. In this study, the validation of the arrayed pulse wave analysis demonstrates that the APV can reliably mirror TCM pulse characteristics.


  • Open Access

    Study on the syndrome characteristics and classification model of non-small cell lung cancer based on tongue and pulse data (Preprint)

    by Yulin Shi, Jiayi Liu, Xiaojuan Hu, Liping Tu, Ji Cui, Jun Li, Zijuan Bi, Jiacai Li, Ling Xu, Jiatuo Xu

    BACKGROUND Lung cancer is a common malignant tumor that affects people's health seriously. Traditional Chinese medicine (TCM) is one of the effective methods for the treatment of advanced lung cancer, accurate TCM syndrome differentiation is essential to treatment. When the symptoms are not obvious, the traditional symptom-based syndrome differentiation cannot be carried out. There is a close relationship between syndrom and index of western medicine, the combination of micro index and macro symptom can assist syndrome differentiation effectively. OBJECTIVE To explore the characteristics of tongue and pulse data of non-small cell lung cancer (NSCLC) with Qi deficiency syndrome and Yin deficiency syndrome, and to establish syndromes classification model based on tongue and pulse data by using machine learning method, and to evaluate the feasibility of the model. METHODS Tongue and pulse data of non-small cell lung cancer (NSCLC) patients with Qi deficiency syndrome (n=163), patients with Yin deficiency syndrome (n=174) and healthy controls (n=185) were collected by using intelligent Tongue and Face Diagnosis Analysis-1 instrument and Pulse Diagnosis Analysis-1 instrument, respectively. The characteristics of tongue and pulse data were analyzed, the correlation analysis was also made on tongue and pulse data. And four machine learning methods, namely Random Forest, Logistic Regression, Support Vector Machine and Neural Network, were used to establish the classification models based on symptoms, tongue & pulse data, and symptoms & tongue & pulse data, respectively. RESULTS Significant difference indexes of tongue diagnosis between Qi deficiency syndrome and Yin deficiency syndrome were TB-a, TB-S, TB-Cr, TC-a, TC-S, TC-Cr, perAll and the tongue coating texture indexes including TC-Con, TC-ASM, TC-MEAN, and TC-ENT. Significant difference indexes of pulse diagnosis were t4 and t5. The classification performance of each model based on different data sets was as follows: model of tongue & pulse data <model of symptom < model of symptom & tongue & pulse data. The Neural Network model had a better classification performance for the symptom & tongue & pulse data, with an area under the ROC curve and accuracy rate were 0.9401 and 0.8806. CONCLUSIONS This study explored the characteristics of tongue and pulse data of NSCLC with Qi deficiency syndrome and Yin deficiency syndrome, and established syndromes classification model. It was feasible to use tongue and pulse data as one of the objective diagnostic indexes in Qi deficiency syndrome and Yin deficiency syndrome of NSCLC. CLINICALTRIAL Trial registration number: ChiCTR1900026008; ChiCTR-IOR-15006502 Date of registration: Jun. 04th, 2015 URL of trial registry record: http://www.chictr.org.cn/showprojen.aspx?proj=11119; http://www.chictr.org.cn/edit.aspx?pid=38828&htm=4 (This is a retrospective registration)

  • Open Access

    Data Mining of Tongue and Pulse based on Tongue Diagnosis and Pulse Diagnosis Instruments:Evaluation of Machine-Learning Assisting Classification of Fatigue Subjects (Preprint)

    by Shi Yulin, Lan Fang, Yao Xinghua, Hu Xiaojuan, Cui Ji, Cui Longtao, Huang Jingbin, Ma Xuxiang, Jiang Tao, Li Jun, et al.

    BACKGROUND Fatigue is one of the most common subjective symptom,due to lack of objective diagnostic criteria ,it is often neglected,especially in the early stage of disease.It is very important to establish an objective evaluation method for diagnosis of disease fatigue and non-disease fatigue based on tongue and pulse data. Our research team has been engaged in the informatization and intelligentization research of TCM diagnosis technology for more than 30 years, we have been engaged in health evaluation and analysis of large clinical sample data for many years, and accumulated a certain amount of typical data,in this area of research, foundation of our work has outstanding advantages. OBJECTIVE The purposes of this study is to explore a new method for clinical diagnosis of fatigue, by analyzing the characteristic of objective tongue and pulse data of disease fatigue subjects and sub-health fatigue subjects, and establishing the diagnosis and classification models of sub-health fatigue and disease fatigue based on the tongue and pulse data. METHODS In this study,736 subjects were selected from the Physical Examination Center, and were divided into healthy control, sub-health fatigue group and disease fatigue group according to physical examination indexes and health status assessment criteria. TFDA-1 tongue diagnosis instrument and PDA-1 pulse diagnosis instrument independently developed were used to collect the tongue image and sphygmogram of the subjects. Multivariate statistical analysis methods were usded to analyze the tongue and pulse data distribution pattern of the fatigue subjects, and machine learning methods were used to establish the diagnostic classification models of fatigue. RESULTS The tongue feature TB-a,TB-b,TB-H,TB-S,TB-I,TB-Cb,TC-L,TC-H,TC-I,TC-Y,TC-Cr,TC-Cb,perAll and perPart were statistically significant different among three groups (P < 0.05, P < 0.01). The sphygmogram feature t1,t4,h5,W1,W2,W1/t and W2/t showed statistically significant differences among three groups (P < 0.05, P < 0.01). There was a canonical correlation between the tongue and pulse data in the disease fatigue group, and the correlation coefficient was 0.649 (P<0.05). Logistic Regression models showed good classification efficiency for data sets of " tongue ", " basic information "and "tongue + pulse + basic information". The area under ROC curve was 0.7352, 0.9089 and 0.9460, respectively. And the Neural Network models showed better classification efficiency for data sets of " pulse " and "tongue + pulse", the area under ROC curve was 0.7957 and 0.8293, respectively. Besides Logistic Regression and Neural Network, Random Forest and SVM also showed good classification results in the diagnosis models. And the classification efficiency of models based on different data sets had the following trends in the three groups: "tongue"models <"pulse" models <" tongue+pulse"models <" basic information"models <" tongue+pulse+basic information "models. CONCLUSIONS Sub-health fatigue and disease fatigue subjects had different tongue and pulse characteristic. Diagnosis and classification models can be established using basic information, tongue and pulse data to explore a new method for evaluating fatigue state.