Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuanjun Sun has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Modified Posterior Wall Ablation in Persistent Atrial Fibrillation: the BOX-AF Randomized Clinical Trial

    by Genqing Zhou, Xiaoyu Wu, Liangrong Zheng, Jingbo Li, Yunlong Xia, Zhiyu Lin, Heng Cai, Songwen Chen, Yu Ding, Yong Wei, et al.

    Aims: The efficacy of left atrial posterior wall isolation (PWI) for persistent atrial fibrillation (AF) is controversial. We propose a modified left atrial posterior wall ablation strategy. Objectives: To evaluate the efficacy and safety of modified posterior wall ablation in patients with persistent AF who underwent first-time radiofrequency catheter ablation. Methods and results: In this multicenter, single-blind randomized trial, 276 patients with persistent AF were assigned 1:1 to pulmonary vein isolation (PVI) with (BOX+) or without modified posterior wall ablation (BOX−). Seven participants withdrew, leaving 269 (BOX+, n=139; BOX−, n=130) for primary endpoint analysis. The primary endpoint was freedom from any documented atrial arrhythmia lasting > 30 seconds without antiarrhythmic drugs after a 3 -month blanking period. At 12-month follow-up, the primary endpoint occurred in 120 of 139 patients (86.3%) in the BOX+ group and 113 of 130 (86.9%) in the BOX− group (hazard ratio 1.046, 95% CI, 0.54 - 2.01; P = 0.894). The BOX+ group exhibited longer procedure time and ablation time. Acute successful PWI was achieved in 91 (65.5%) patients assigned to BOX+. In a nonprespecified, post-randomization analysis, arrhythmia-free survival was 93.4% in patients with acute successful PWI, 72.9% in those with attempted but unsuccessful PWI, and 86.9% in controls without attempted PWI (overall log-rank P=0.002). Adverse events were similar between groups. Conclusion: Routine addition of modified posterior wall ablation did not improve overall outcomes of first-time ablation in persistent AF. However, achieving successful PWI was associated with significantly lower recurrence.

  • Transseptal Sheath Perfused With High Concentration Heparinized Saline for Reducing Sheath‐Associated Thrombus

    by Juan Xu, Shi Peng, Yuanjun Sun, Zhenning Nie, Ya Zhen, Xiaomeng Yin, Xiaofeng Lu, Yan Liu, Xiaoyu Zhang, Dayang Huang, et al.

    Background: Transseptal catheterization is critical for atrial fibrillation (AF) ablation but risks thromboembolism. Transseptal sheaths (TSS) were suggested for continuous heparinized saline solution flush. The safety and effectiveness of a simple TSS management to reduce sheath‐associated thrombus development risk was investigated.Methods: AF patients who underwent radiofrequency ablation with the simple TSS management were studied under a retrospective multi‐center observation study and a prospective single‐center observation study. TSS and dilators were washed and perfused with high concentration heparinized saline (20 u/mL). Immediately after two successful transseptal punctures, activated clotting time ≥300 s was maintained by heparin infusion. TSS aspiration with negative suction and re‐perfusion with high concentration heparinized saline (20 u/mL) was performed for the remaining procedure before and after catheter withdrawal.Results: A total of 4765 AF patients underwent 5367 ablation procedures were enrolled in the retrospective study, involving 156 (2.9% per procedure) complications. No acute stroke occurred during all the procedures. Perioperative thromboembolic complications occurred in 10 (0.21%) patients and in 10 (0.19%) procedures. Thromboembolic complications occurred within 24 h, between 24–48 h, and after 48 h post‐procedure in six, two, and two patients, respectively. In the prospective observation study, neither sheath‐ nor catheter‐associated thrombus were detected by the intracardiac echocardiography during all 127 procedures, without any perioperative thromboembolic complications. No hemorrhagic cerebrovascular complication was encountered in both observational studies.Conclusion: For AF radiofrequency ablation, it was safe and effective for TSS high concentration heparinized saline infusion only. This approach could avoid sheath‐associated thrombus for interventional procedures.


  • Open Access

    Benefit of Catheter Ablation for Atrial Fibrillation in Heart Failure Patients with Different Etiologies

    by Songbing Long, Yuanjun Sun, Xianjie Xiao, Zhongzhen Wang, Wei Sun, Lianjun Gao, Yunlong Xia, Xiaomeng Yin

    (1) Background: A plethora of studies have elucidated the safety and efficacy of catheter ablation (CA) for patients afflicted with atrial fibrillation (AF) and concomitant reduction in left ventricular ejection fraction (LVEF). Nevertheless, the literature on the benefits of CA in the specific etiological context of heart failure (HF) remains limited. This study delineates a comparative assessment of outcomes for patients with AF and reduced LVEF across the primary etiologies. (2) Methods: Our inquiry encompassed 216 patients diagnosed with congestive heart failure and an LVEF of less than 50 percent who were referred to our institution for circumferential pulmonary vein isolation (CPVI) between the years 2016 and 2020. The selection criteria included a detailed medical history while excluding those suffering from valvular disease, congenital heart disease, and hypertrophic cardiomyopathy. In an effort to scrutinize varying etiologies, patients were stratified into three categories: dilated cardiomyopathy (DCM, n = 56, 30.6%), ischemic cardiomyopathy (ICM, n = 68, 37.2%), and tachycardia-induced cardiomyopathy (TIC, n = 59, 32.2%). (3) Results: Following an average (±SD) duration of 36 ± 3 months, the prevalence of sinus rhythm was 52.1% in the DCM group, 50.0% in the ICM group, and 68.14% in the TIC group (p = 0.014). This study revealed a significant disparity between the DCM and TIC groups (p = 0.021) and the ICM and TIC groups (p = 0.007), yet no significant distinction was discerned between the TIC and ICM groups (p = 0.769). Importantly, there were no significant variations in the application of antiarrhythmic drugs or recurrence of procedures among the three groups. The mortality rates were 14.29% for the DCM group and 14.71% for the ICM group, which were higher than the 3.39% observed in the TIC group (DCM vs. TIC p = 0.035 (HR = 4.50 (95%CI 1.38–14.67)), ICM vs. TIC p = 0.021 (HR = 5.00 (95%CI 1.61–15.50))). A noteworthy enhancement in heart function was evidenced in the TIC group in comparison to the DCM and ICM groups, including a higher LVEF (p < 0.001), diminution of LV end-diastolic diameter (p < 0.001), and an enhanced New York Heart Association classification (p = 0.005). Hospitalization rates for heart failure were discernibly lower in TIC patients (0.98 (0,2) times) relative to those with DCM (1.74 (0,3) times, p < 0.01) and TIC (1.78 (0,4) times, p < 0.001). Patients with paroxysmal atrial fibrillation and brief episodes were found to achieve superior clinical outcomes through a catheter ablation strategy. (4) Conclusion: Patients diagnosed with TIC demonstrated a more pronounced benefit from catheter ablation compared to those with DCM and ICM. This encompassed an augmented improvement in cardiac function, an enhanced maintenance of sinus rhythm, and a reduced mortality rate.


  • Open Access

    Cardiomyopathy induced by premature ventricular contractions with ventricular escape beats in the compensatory pause: A case report and brief review of the literature

    by Yuanjun Sun, Xiaohong Yu, Xianjie Xiao, Shiyu Dai, Rongfeng Zhang, Zhongzhen Wang, Chengming Ma, Xiaomeng Yin, Lianjun Gao, Yanzong Yang, et al.

    Rationale: We reported a case with cardiomyopathy induced by frequent premature ventricular contractions (PVCs) and followed ventricular escape beats (VEBs). PVCs with VEBs in the compensatory pause which induced cardiomyopathy is rarely reported. Also, the case exhibited many characteristics of PVCs which were more likely to induce cardiomyopathy, like the location of origin, the longer coupling interval, and the QRS wave companied with the P wave. Patient concerns: A 53-year-old man with left ventricular (LV) dysfunction presented with palpation, chest distress, and dyspnea for 3 years. Holter revealed a high burden of ventricular rhythm of PVCs and another wide QRS patterns (96,562 total beats with 87,330 wide QRS beats in 24 hours). The LV ejection fraction decreased to 34% and the left ventricle, right and left atria all dilated. Diagnosis: He was diagnosed with PVC-induced cardiomyopathy. Interventions: The patient experienced intracardiac electrophysiological examination which revealed frequent PVCs followed by VEBs in the compensatory pause. Activation mapping of the PVCS and ablation were performed. Outcomes: PVCs and VEBs disappeared after ablation. The LV ejection fraction increased to 46% at 2 days after the procedure. The diameters of the right and left atria were also significantly reduced. Lessons: VEBs may occur during the compensatory pause of PVCs. PVCs with VEBs can lead to a high burden of ventricular rhythm and LV dysfunction. Ablation of the PVCs can also eliminate VEBs and improve the LV function.


  • High efficiency and workflow of His bundle pacing and atrioventricular node ablation guided by three‐dimensional mapping system

    by Yuanjun Sun, Xiaohong Yu, Xianjie Xiao, Xiaomeng Yin, Lianjun Gao, Rongfeng Zhang, Shiyu Dai, Nan Wang, Duoduo Zhang, Yingxue Dong, et al.

    Background: Atrioventricular node (AVN) ablation combined with His bundle pacing is an effective strategy for permanent atrial fibrillation (AF) with rapid ventricular rate refractory to pharmacological therapy. We aimed to access the feasibility and efficiency of His bundle pacing and AVN ablation guided by three‐dimensional (3‐D) mapping system throughout the procedure.Methods: Eighteen patients with permanent AF with refractory rate and symptoms were referred for His bundle pacing and AVN ablation guided by 3‐D mapping (CARTO3). Electroanatomic 3‐D mapping of the right atrium and right ventricle was performed by the ablation catheter with CARTO 3 system, followed by the visualization of the leads for implantation and AVN ablation.Results: Implantation of His bundle and ventricular leads and AVN ablation were achieved successfully with the help of 3‐D mapping in 17 patients. Selective His bundle pacing was achieved in five patients (29.4%), and the other (70.6%) were nonselective His bundle pacing. The mean procedure duration was 99.4 ± 16.4 minutes. The mean fluoroscopy time was 7.0 ± 2.6 minutes. The time spent on His lead implantation was 6.1 ± 3.2 minutes. One patient experienced AVN ablation from left side under aortic valves due to no effect of ablation in right atrium.Conclusion: His bundle pacing and AVN ablation guided by throughout real‐time 3‐D mapping system are of high‐efficiency and feasibility.