Minoru Yamada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Minoru Yamada has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Yoshitake Yamada
Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
8 shared publications - Masahiro Jinzaki
Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
7 shared publications - Takeo Nagura
Department of Clinical Biomechanics, Keio University School of Medicine, Tokyo, Japan
7 shared publications - Yoichi Yokoyama
Department of Radiology, Keio University School of Medicine, Tokyo, Japan
7 shared publications - Masaya Nakamura
Department of Orthopaedic Surgery Keio University School of Medicine Tokyo Japan
4 shared publications - Yuki Yoshida
Department of Orthopaedic Surgery, Fussa Hospital, Tokyo, Japan
4 shared publications
Latest Publications
- Open Access
- 23 October 2025
- Published by Elsevier in Gait & Posture
- Vol. 123, 110021
Three-dimensional in vivo kinematics of the subtalar joint during weight-bearing standing on coronal-wedge surfaces using upright computed tomography
- 23 October 2025
- Published by Elsevier in Gait & Posture
- Vol. 123, 110021
Open AccessThree-dimensional in vivo kinematics of the subtalar joint during weight-bearing standing on coronal-wedge surfaces using upright computed tomography
- Open Access
- 10 March 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 183, 112630
Simultaneous quantification of lower limb skeletal posture and ground reaction forces using upright computed tomography: Potential implications for osteoarthritis assessment and treatment
- 10 March 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 183, 112630
Open AccessSimultaneous quantification of lower limb skeletal posture and ground reaction forces using upright computed tomography: Potential implications for osteoarthritis assessment and treatment
- 17 September 2022
- Published by Springer Nature in Skeletal Radiology
- Vol. 52 (2) , 215-224
Changes in the lumbar intervertebral foramen between supine and standing posture in patients with adult spinal deformity: a study with upright computed tomography
Objective To quantitatively assess the impact of supine and standing positions on the morphological changes in the lumbar intervertebral foramen (LIF) in patients with adult spinal deformity (ASD) using upright CT and conventional supine CT. Materials and methods Thirty patients with ASD were prospectively enrolled in this study. All subjects underwent standing whole spine posterior/anterior radiographs, lateral radiographs, and whole spine CT, both in the supine and upright standing positions. Two orthopedic surgeons independently measured nine radiographic parameters in the radiograph and the lumbar foraminal area (FA) and height (FH) in supine and upright CT. Statistical analyses were performed to evaluate the risk of LIF decrease when standing upright compared to the supine position. The chi-squared, t test, Pearson’s coefficients, intra- and inter-rater reliabilities, and ROC curves were calculated. The level of significance was set at p < 0.05. Results Among the 300 LIFs, both the lumbar FA and FH were either increased or decreased by > 5% in approximately 30% of LIFs each. The FA decreased in the lower lumbar spine. The concave side had a significantly higher rate of decreased FA and FH than the convex side (p < 0.05 and < 0.05, respectively). ROC analysis showed that narrowing of the intervertebral disc (cutoff > 0.05°) is a risk factor for decreased FA and FH. Conclusions This study describes the details of the changes in the neuroforamen using a novel upright CT. In patients with ASD, approximately 30% of LIFs either increased or decreased in size by > 5% when standing. The risk factors for LIF decrease are the lower lumbar spine, concave side, and narrow side of the disc wedge.
- 17 September 2022
- Published by Springer Nature in Skeletal Radiology
- Vol. 52 (2) , 215-224
Changes in the lumbar intervertebral foramen between supine and standing posture in patients with adult spinal deformity: a study with upright computed tomography
Objective To quantitatively assess the impact of supine and standing positions on the morphological changes in the lumbar intervertebral foramen (LIF) in patients with adult spinal deformity (ASD) using upright CT and conventional supine CT. Materials and methods Thirty patients with ASD were prospectively enrolled in this study. All subjects underwent standing whole spine posterior/anterior radiographs, lateral radiographs, and whole spine CT, both in the supine and upright standing positions. Two orthopedic surgeons independently measured nine radiographic parameters in the radiograph and the lumbar foraminal area (FA) and height (FH) in supine and upright CT. Statistical analyses were performed to evaluate the risk of LIF decrease when standing upright compared to the supine position. The chi-squared, t test, Pearson’s coefficients, intra- and inter-rater reliabilities, and ROC curves were calculated. The level of significance was set at p < 0.05. Results Among the 300 LIFs, both the lumbar FA and FH were either increased or decreased by > 5% in approximately 30% of LIFs each. The FA decreased in the lower lumbar spine. The concave side had a significantly higher rate of decreased FA and FH than the convex side (p < 0.05 and < 0.05, respectively). ROC analysis showed that narrowing of the intervertebral disc (cutoff > 0.05°) is a risk factor for decreased FA and FH. Conclusions This study describes the details of the changes in the neuroforamen using a novel upright CT. In patients with ASD, approximately 30% of LIFs either increased or decreased in size by > 5% when standing. The risk factors for LIF decrease are the lower lumbar spine, concave side, and narrow side of the disc wedge.
- Open Access
Three-Dimensional Quantitative Evaluation of the Scapular Skin Marker Movements in the Upright Posture
Motion capture systems using skin markers are widely used to evaluate scapular kinematics. However, soft-tissue artifact (STA) is a major limitation, and there is insufficient knowledge of the marker movements from the original locations. This study explores a scapular STA, including marker movements with shoulder elevation using upright computed tomography (CT). Ten healthy males (twenty shoulders in total) had markers attached to scapular bony landmarks and underwent upright CT in the reference and elevated positions. Marker movements were calculated and compared between markers. The bone-based and marker-based scapulothoracic rotation angles were also compared in both positions. The median marker movement distances were 30.4 mm for the acromial angle, 53.1 mm for the root of the scapular spine, and 70.0 mm for the inferior angle. Marker movements were significantly smaller on the superolateral aspect of the scapula, and superior movement was largest in the directional movement. Scapulothoracic rotation angles were significantly smaller in the marker-based rotation angles than in the bone-based rotation angles of the elevated position. We noted that the markers especially did not track the inferior movement of the scapular motion with shoulder elevation, resulting in an underestimation of the marker-based rotation angles.
Open AccessThree-Dimensional Quantitative Evaluation of the Scapular Skin Marker Movements in the Upright Posture
Motion capture systems using skin markers are widely used to evaluate scapular kinematics. However, soft-tissue artifact (STA) is a major limitation, and there is insufficient knowledge of the marker movements from the original locations. This study explores a scapular STA, including marker movements with shoulder elevation using upright computed tomography (CT). Ten healthy males (twenty shoulders in total) had markers attached to scapular bony landmarks and underwent upright CT in the reference and elevated positions. Marker movements were calculated and compared between markers. The bone-based and marker-based scapulothoracic rotation angles were also compared in both positions. The median marker movement distances were 30.4 mm for the acromial angle, 53.1 mm for the root of the scapular spine, and 70.0 mm for the inferior angle. Marker movements were significantly smaller on the superolateral aspect of the scapula, and superior movement was largest in the directional movement. Scapulothoracic rotation angles were significantly smaller in the marker-based rotation angles than in the bone-based rotation angles of the elevated position. We noted that the markers especially did not track the inferior movement of the scapular motion with shoulder elevation, resulting in an underestimation of the marker-based rotation angles.
- Open Access
- 15 April 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17 (1) , 1-9
Three-dimensional alignment of the upper extremity in the standing neutral position in healthy subjects
Background: Though alignment of the spine and lower extremities in the standing neutral position has been evaluated, a few studies evaluating the alignment of the upper extremities have also been made. This study assessed the normal alignment of the upper extremities in the standing neutral position and clarified the three-dimensional angular rotations of the upper extremity joints. Methods: Computed tomography (CT) images of 158 upper extremities from 79 healthy volunteers were prospectively acquired in the standing neutral position using an upright CT scanner. Three-dimensional coordinate systems of the thorax, scapula, humerus, and forearm were designated, and three-dimensional angular rotations of the scapulothoracic, glenohumeral, and elbow joints were calculated. Results: The median angle of the scapulothoracic joint was 9.2° (interquartile range [IQR], 5.2°–12.5°) of upward rotation, 29.0° (IQR, 24.9°–33.3°) of internal rotation, and 7.9° (IQR, 4.3°–11.8°) of anterior tilt. The median angle of the glenohumeral joint was 4.5° (IQR, 0.9°–7.8°) of abduction, 9.0° (IQR, 2.2°–19.0°) of internal rotation, and 0.3° (IQR, − 2.6°–3.1°) of extension. The median angle of the elbow joint was 9.8° (IQR, 6.9°–12.4°) of valgus, 90.2° (IQR, 79.6°–99.4°) of pronation, and 15.5° (IQR, 13.2°–18.1°) of flexion. Correlations in angular rotation values were found between the right and left upper extremities and between joints. Conclusions: This study clarified the three-dimensional angular rotation of upper extremity joints in the standing neutral position using an upright CT scanner. Our results may provide important insights for the functional evaluation of upper extremity alignment.
- 15 April 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17 (1) , 1-9
Open AccessThree-dimensional alignment of the upper extremity in the standing neutral position in healthy subjects
Background: Though alignment of the spine and lower extremities in the standing neutral position has been evaluated, a few studies evaluating the alignment of the upper extremities have also been made. This study assessed the normal alignment of the upper extremities in the standing neutral position and clarified the three-dimensional angular rotations of the upper extremity joints. Methods: Computed tomography (CT) images of 158 upper extremities from 79 healthy volunteers were prospectively acquired in the standing neutral position using an upright CT scanner. Three-dimensional coordinate systems of the thorax, scapula, humerus, and forearm were designated, and three-dimensional angular rotations of the scapulothoracic, glenohumeral, and elbow joints were calculated. Results: The median angle of the scapulothoracic joint was 9.2° (interquartile range [IQR], 5.2°–12.5°) of upward rotation, 29.0° (IQR, 24.9°–33.3°) of internal rotation, and 7.9° (IQR, 4.3°–11.8°) of anterior tilt. The median angle of the glenohumeral joint was 4.5° (IQR, 0.9°–7.8°) of abduction, 9.0° (IQR, 2.2°–19.0°) of internal rotation, and 0.3° (IQR, − 2.6°–3.1°) of extension. The median angle of the elbow joint was 9.8° (IQR, 6.9°–12.4°) of valgus, 90.2° (IQR, 79.6°–99.4°) of pronation, and 15.5° (IQR, 13.2°–18.1°) of flexion. Correlations in angular rotation values were found between the right and left upper extremities and between joints. Conclusions: This study clarified the three-dimensional angular rotation of upper extremity joints in the standing neutral position using an upright CT scanner. Our results may provide important insights for the functional evaluation of upper extremity alignment.
- Open Access
- 23 September 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-9
Evaluation of three-dimensional acromiohumeral distance in the standing position and comparison with its conventional measuring methods
Background: Narrowing of the acromiohumeral distance (AHD) implies a rotator cuff tear. However, conventional AHD measurements using two-dimensional (2D) imaging or with the patient in the supine position might differ from that while standing during daily activity. This study aimed to evaluate the three-dimensional (3D) actual distance between the acromion and humeral head in the standing position and compare the AHD values with those obtained using conventional measuring methods. Methods: Computed tomography (CT) images of 166 shoulders from 83 healthy volunteers (31 male and 52 female; mean age 40.1 ± 5.8 years; age range, 30–49 years) were prospectively acquired in the supine and standing positions using conventional and upright CT scanners, respectively. The minimum distance between the acromion and humeral head on the 3D surface models was considered as the 3D AHD. We measured the 2D AHD on anteroposterior digitally reconstructed radiographs. The AHD values were compared between the supine and standing positions and between the 2D and 3D measurements. Results: The mean values of 2D AHD were 8.8 ± 1.3 mm (range, 5.9–15.4 mm) in the standing position and 8.1 ± 1.2 mm (range, 5.3–14.3 mm) in the supine position. The mean values of 3D AHD were 7.3 ± 1.4 mm (range, 4.7–14.0 mm) in the standing position and 6.6 ± 1.2 mm (range, 4.4–13.7 mm) in the supine position. The values of 3D AHD were significantly lower than those of 2D AHDs in both the standing and supine positions (P < 0.001). The values of 2D and 3D AHDs were significantly lower in the supine position than in the standing position (P < 0.001). Conclusions: This study evaluated the 3D AHD of normal shoulders in the standing position using an upright CT scanner. The present results indicated that assessments in the supine position can underestimate the value of the AHD compared with those made in the standing position and that assessments using 2D analysis can overestimate the value.
- 23 September 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-9
Open AccessEvaluation of three-dimensional acromiohumeral distance in the standing position and comparison with its conventional measuring methods
Background: Narrowing of the acromiohumeral distance (AHD) implies a rotator cuff tear. However, conventional AHD measurements using two-dimensional (2D) imaging or with the patient in the supine position might differ from that while standing during daily activity. This study aimed to evaluate the three-dimensional (3D) actual distance between the acromion and humeral head in the standing position and compare the AHD values with those obtained using conventional measuring methods. Methods: Computed tomography (CT) images of 166 shoulders from 83 healthy volunteers (31 male and 52 female; mean age 40.1 ± 5.8 years; age range, 30–49 years) were prospectively acquired in the supine and standing positions using conventional and upright CT scanners, respectively. The minimum distance between the acromion and humeral head on the 3D surface models was considered as the 3D AHD. We measured the 2D AHD on anteroposterior digitally reconstructed radiographs. The AHD values were compared between the supine and standing positions and between the 2D and 3D measurements. Results: The mean values of 2D AHD were 8.8 ± 1.3 mm (range, 5.9–15.4 mm) in the standing position and 8.1 ± 1.2 mm (range, 5.3–14.3 mm) in the supine position. The mean values of 3D AHD were 7.3 ± 1.4 mm (range, 4.7–14.0 mm) in the standing position and 6.6 ± 1.2 mm (range, 4.4–13.7 mm) in the supine position. The values of 3D AHD were significantly lower than those of 2D AHDs in both the standing and supine positions (P < 0.001). The values of 2D and 3D AHDs were significantly lower in the supine position than in the standing position (P < 0.001). Conclusions: This study evaluated the 3D AHD of normal shoulders in the standing position using an upright CT scanner. The present results indicated that assessments in the supine position can underestimate the value of the AHD compared with those made in the standing position and that assessments using 2D analysis can overestimate the value.
- Open Access
- 15 September 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-8
Three-dimensional alignment changes of the shoulder girdle between the supine and standing positions
Background: Although humans spend most of their day in a standing or sitting position, it is difficult to accurately evaluate the alignment of the shoulder girdle during daily activity, and its alignment changes between positions. The purpose of this study was to evaluate the 3-dimensional alignment of the shoulder girdle in the supine and standing positions by computed tomography (CT) and to assess the alignment changes of the shoulder girdle between these two positions. Methods: CT scans of both shoulders of 100 healthy volunteers were prospectively taken in both supine and standing positions on the same day. The local 3-dimensional coordinate systems of the thorax, clavicle, and scapula were defined from the specific bony landmarks, and 3-dimensional angular rotations and positions of the clavicle and scapula were calculated. Differences in rotations and positions of the clavicle and scapula were evaluated between the supine and standing positions. Results: Compared with the supine position, the clavicle showed significantly less elevation and greater retraction, and the scapula showed significantly less upward rotation, anterior tilting, and internal rotation in the standing position. Compared with the supine position, the clavicle center was located more inferiorly, posteriorly, and laterally, and the scapula center was located more inferiorly, posteriorly, and medially in the standing position. Conclusions: The present study showed that angular rotations and positions of the clavicle and scapula change significantly with position due to the effect of gravity.
- 15 September 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-8
Open AccessThree-dimensional alignment changes of the shoulder girdle between the supine and standing positions
Background: Although humans spend most of their day in a standing or sitting position, it is difficult to accurately evaluate the alignment of the shoulder girdle during daily activity, and its alignment changes between positions. The purpose of this study was to evaluate the 3-dimensional alignment of the shoulder girdle in the supine and standing positions by computed tomography (CT) and to assess the alignment changes of the shoulder girdle between these two positions. Methods: CT scans of both shoulders of 100 healthy volunteers were prospectively taken in both supine and standing positions on the same day. The local 3-dimensional coordinate systems of the thorax, clavicle, and scapula were defined from the specific bony landmarks, and 3-dimensional angular rotations and positions of the clavicle and scapula were calculated. Differences in rotations and positions of the clavicle and scapula were evaluated between the supine and standing positions. Results: Compared with the supine position, the clavicle showed significantly less elevation and greater retraction, and the scapula showed significantly less upward rotation, anterior tilting, and internal rotation in the standing position. Compared with the supine position, the clavicle center was located more inferiorly, posteriorly, and laterally, and the scapula center was located more inferiorly, posteriorly, and medially in the standing position. Conclusions: The present study showed that angular rotations and positions of the clavicle and scapula change significantly with position due to the effect of gravity.