Laura Valencia-Nieto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Laura Valencia-Nieto has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- María Jesús González García
Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid (UVa), Campus Miguel Delibes, Paseo de Belén 17, 47011 Valladolid, Spain
10 shared publications - Alberto López-Miguel
Universidad de Valladolid
6 shared publications - Alberto López-De la Rosa
Department of Theoretical Physics, Atomic and Optics University of Valladolid Valladolid Spain
5 shared publications - Cristina Arroyo-Del Arroyo
Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain
5 shared publications - Marta Blanco-Vázquez
Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid (UVa), Campus Miguel Delibes, Paseo de Belén 17, 47011 Valladolid, Spain
5 shared publications - Amalia Enríquez-De-Salamanca
Institute of Applied Ophthalmobiology (IOBA), Universidad de Valladolid (UVa), Campus Miguel Delibes, Paseo de Belén 17, 47011 Valladolid, Spain
4 shared publications
Latest Publications
- Open Access
Longitudinal Changes in Peripheral Refraction, Lag and Axial Length in Myopic Children Treated with Orthokeratology: A 12-Month Prospective Study
Background/Objectives: High accommodative lag and relative peripheral hyperopic defocus during near work have been proposed as potential contributors to myopia progression. Orthokeratology (OK) reshapes the cornea to provide central correction while inducing peripheral myopic defocus. This prospective 12-month study aimed to evaluate longitudinal changes in peripheral refraction, accommodative lag, and axial length (AL) in myopic children treated with OK. Methods: Children aged 7 to 17 years with low-to-moderate myopia were fitted with spherical (CRT™ STD) or toric (CRT™ DA) OK lenses and followed for 12 months. Horizontal peripheral refraction (vector M, J0, J45) up to ±30°, accommodative lag and non-cycloplegic AL were measured. Results: Forty-seven participants completed the study. Mean AL increased from 24.76 ± 0.87 mm at baseline to 24.86 ±0.85 mm at 12 months (p < 0.001). OK induced a stable, symmetrical redistribution of relative peripheral myopic defocus across visits. The toric design showed more consistent significant variations in the J0 astigmatic component across eccentricities. No significant correlations were found between AL elongation and changes in peripheral refraction (p = 0.194) or accommodative lag (p > 0.05) in the overall sample. However, subjects in the lag variation group showed significant AL increases (p < 0.05), while those in the no lag variation group did not (p > 0.05). Conclusions: OK consistently induces a stable pattern of peripheral myopic defocus. While peripheral defocus and accommodative lag do not linearly correlate with global axial growth, accommodative behavior may be associated with individual differences in axial growth. Biometry remains important for monitoring treatment outcomes.
Open AccessLongitudinal Changes in Peripheral Refraction, Lag and Axial Length in Myopic Children Treated with Orthokeratology: A 12-Month Prospective Study
Background/Objectives: High accommodative lag and relative peripheral hyperopic defocus during near work have been proposed as potential contributors to myopia progression. Orthokeratology (OK) reshapes the cornea to provide central correction while inducing peripheral myopic defocus. This prospective 12-month study aimed to evaluate longitudinal changes in peripheral refraction, accommodative lag, and axial length (AL) in myopic children treated with OK. Methods: Children aged 7 to 17 years with low-to-moderate myopia were fitted with spherical (CRT™ STD) or toric (CRT™ DA) OK lenses and followed for 12 months. Horizontal peripheral refraction (vector M, J0, J45) up to ±30°, accommodative lag and non-cycloplegic AL were measured. Results: Forty-seven participants completed the study. Mean AL increased from 24.76 ± 0.87 mm at baseline to 24.86 ±0.85 mm at 12 months (p < 0.001). OK induced a stable, symmetrical redistribution of relative peripheral myopic defocus across visits. The toric design showed more consistent significant variations in the J0 astigmatic component across eccentricities. No significant correlations were found between AL elongation and changes in peripheral refraction (p = 0.194) or accommodative lag (p > 0.05) in the overall sample. However, subjects in the lag variation group showed significant AL increases (p < 0.05), while those in the no lag variation group did not (p > 0.05). Conclusions: OK consistently induces a stable pattern of peripheral myopic defocus. While peripheral defocus and accommodative lag do not linearly correlate with global axial growth, accommodative behavior may be associated with individual differences in axial growth. Biometry remains important for monitoring treatment outcomes.
- Open Access
- 1 October 2025
- Published by Elsevier in Journal of Optometry
- Vol. 19 (1) , 100581
A review of contact lens discomfort: from the clinic to the laboratory
- 1 October 2025
- Published by Elsevier in Journal of Optometry
- Vol. 19 (1) , 100581
Open AccessA review of contact lens discomfort: from the clinic to the laboratory
- Open Access
- 12 September 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (18) , 8918
Long-Term Clinical and Molecular Changes in Dry Eye Disease and Chronic Ocular Pain
Dry eye disease (DED) is a prevalent condition characterized by ocular surface inflammation and pain. This study evaluated the long-term progression of DED by analyzing clinical and molecular status, considering the impact of chronic ocular pain. Patients with DED were evaluated at two visits (V1 and V2) separated by at least two years. Evaluations included validated symptom questionnaires alongside slit-lamp examination, corneal sensitivity testing, and sub-basal nerve plexus analysis. Basal tear samples were collected for multiplex quantification of 20 cytokines and substance P (SP), and conjunctival cells were obtained to analyze 25 genes and 12 microRNAs (miRNA). Based on the presence or absence of chronic ocular pain, patients were then divided into two groups. Patients improved in DED-related symptoms, with no changes observed in ocular surface signs. Corneal dendritic cell density decreased, along with epidermal growth factor (EGF), fractalkine, and monocyte chemoattractant protein (MCP-1) tear levels, whereas interleukin (IL)-10 and SP tear levels increased. Neurotrophic tyrosine kinase, receptor, type (NTRK)1 gene expression was significantly downregulated, especially in patients without chronic ocular pain. miR-665 expression decreased significantly in DED patients. Monitoring corneal dendritic cells, tear cytokines, and gene/miRNA expression offers promising tools for tracking DED progression. Distinguishing the presence of chronic ocular pain as a separate symptom is crucial to optimizing therapeutic strategies and DED progression.
- 12 September 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (18) , 8918
Open AccessLong-Term Clinical and Molecular Changes in Dry Eye Disease and Chronic Ocular Pain
Dry eye disease (DED) is a prevalent condition characterized by ocular surface inflammation and pain. This study evaluated the long-term progression of DED by analyzing clinical and molecular status, considering the impact of chronic ocular pain. Patients with DED were evaluated at two visits (V1 and V2) separated by at least two years. Evaluations included validated symptom questionnaires alongside slit-lamp examination, corneal sensitivity testing, and sub-basal nerve plexus analysis. Basal tear samples were collected for multiplex quantification of 20 cytokines and substance P (SP), and conjunctival cells were obtained to analyze 25 genes and 12 microRNAs (miRNA). Based on the presence or absence of chronic ocular pain, patients were then divided into two groups. Patients improved in DED-related symptoms, with no changes observed in ocular surface signs. Corneal dendritic cell density decreased, along with epidermal growth factor (EGF), fractalkine, and monocyte chemoattractant protein (MCP-1) tear levels, whereas interleukin (IL)-10 and SP tear levels increased. Neurotrophic tyrosine kinase, receptor, type (NTRK)1 gene expression was significantly downregulated, especially in patients without chronic ocular pain. miR-665 expression decreased significantly in DED patients. Monitoring corneal dendritic cells, tear cytokines, and gene/miRNA expression offers promising tools for tracking DED progression. Distinguishing the presence of chronic ocular pain as a separate symptom is crucial to optimizing therapeutic strategies and DED progression.
- Open Access
- 9 September 2025
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 20, 1-7
Characterization of the Pre-lens Tear Film in Hydrogel and Silicone Hydrogel Contact Lens Wear
Purpose: Different contact lens (CL) materials have been associated with different behaviors of pre-lens tear film components in the short term. The purpose of this randomized crossover and double-masked study was to compare the effect of wearing hydrogel and silicone hydrogel CLs on pre-lens tear film status. Methods: Soft CL wearers were recruited and randomly fitted with a hydrogel (omafilcon A) and a silicone hydrogel (stenfilcon A) CL. Tear evaporation rate, non-invasive tear break-up time (NIBUT), tear film lipid layer thickness, and partial blink rate were measured without CLs and 30 minutes after the insertion of CLs. The outcomes were analyzed using repeated measures analysis of variance or the Friedman test. Results: Twenty-four CL wearers (6 men and 18 women) aged 23.3 ± 3.9 years were included. Tear evaporation rate was higher with the hydrogel CL (98.6 ± 59.4 g/m2/h; P = 0.043) and the silicone hydrogel CL (99.7 ± 60.6 g/m2/h; P = 0.037) compared to no CL wear (69.9 ± 41.3 g/m2/h). NIBUT was lower (P = 0.019) with the silicone hydrogel CL (12.7 ± 6.2 s) than with no CL wear (18.5 ± 9.8 s). Lipid layer thickness was lower with the hydrogel CL (64.9 ± 15.5) than with the silicone hydrogel CL (75.8 ± 14.0; P < 0.001) and no CL wear (75.9 ± 14.2; P = 0.001). No statistically significant differences were found in the partial blink rate. Conclusion: This study demonstrated that both hydrogel and silicone hydrogel CLs disrupt the tear film by increasing tear evaporation and causing tear film instability. However, CL materials affect the pre-lens tear film status differently. Further studies with longer wearing times are required.
- 9 September 2025
- Published by Knowledge E DMCC in Journal of Ophthalmic and Vision Research
- Vol. 20, 1-7
Open AccessCharacterization of the Pre-lens Tear Film in Hydrogel and Silicone Hydrogel Contact Lens Wear
Purpose: Different contact lens (CL) materials have been associated with different behaviors of pre-lens tear film components in the short term. The purpose of this randomized crossover and double-masked study was to compare the effect of wearing hydrogel and silicone hydrogel CLs on pre-lens tear film status. Methods: Soft CL wearers were recruited and randomly fitted with a hydrogel (omafilcon A) and a silicone hydrogel (stenfilcon A) CL. Tear evaporation rate, non-invasive tear break-up time (NIBUT), tear film lipid layer thickness, and partial blink rate were measured without CLs and 30 minutes after the insertion of CLs. The outcomes were analyzed using repeated measures analysis of variance or the Friedman test. Results: Twenty-four CL wearers (6 men and 18 women) aged 23.3 ± 3.9 years were included. Tear evaporation rate was higher with the hydrogel CL (98.6 ± 59.4 g/m2/h; P = 0.043) and the silicone hydrogel CL (99.7 ± 60.6 g/m2/h; P = 0.037) compared to no CL wear (69.9 ± 41.3 g/m2/h). NIBUT was lower (P = 0.019) with the silicone hydrogel CL (12.7 ± 6.2 s) than with no CL wear (18.5 ± 9.8 s). Lipid layer thickness was lower with the hydrogel CL (64.9 ± 15.5) than with the silicone hydrogel CL (75.8 ± 14.0; P < 0.001) and no CL wear (75.9 ± 14.2; P = 0.001). No statistically significant differences were found in the partial blink rate. Conclusion: This study demonstrated that both hydrogel and silicone hydrogel CLs disrupt the tear film by increasing tear evaporation and causing tear film instability. However, CL materials affect the pre-lens tear film status differently. Further studies with longer wearing times are required.
- Open Access
- 20 June 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (13) , 4406
Long-Term Evolution of Chronic Neuropathic Ocular Pain and Dry Eye Following Corneal Refractive Surgery
Background/Objectives: Chronic neuropathic ocular pain (NOP) can manifest concurrently with dry eye (DE) symptoms following ocular surgical procedures. Due to its low prevalence, NOP remains an underrecognized and underdiagnosed postoperative complication, leading to suboptimal management. This study evaluated the long-term evolution of symptoms, signs, and tear biomarkers in patients with NOP and DE after corneal refractive surgery (RS). Methods: Patients with chronic NOP and persistent DE-related symptoms after corneal RS were assessed in two visits (V1 and V2), at least two years apart. Symptoms (DE, pain, anxiety, and depression) were measured with specific questionnaires. Clinical examination included a slit-lamp ocular surface evaluation, corneal sensitivity measurement, and subbasal corneal nerve plexus evaluation. Basal tear samples were collected, and a 20-plex cytokine panel and Substance P (SP) were assayed. Results: Twenty-three patients (35.57 ± 8.43 years) were included, with a mean time between visits of 4.83 ± 1.10 years. DE symptoms, measured with the Ocular Surface Disease Index questionnaire, improved at V2 (p < 0.001), along with a reduction in anxiety and depression levels, measured with the Hospital Anxiety and Depression Scale (p = 0.027). Corneal staining also decreased (p < 0.001), while subbasal nerve plexus parameters and corneal sensitivity remained unchanged. Tear analysis revealed increased concentrations of fractalkine/CX3CL1 (p = 0.039), interleukin (IL)-1 receptor antagonist (Ra) (p = 0.025), IL-10 (p = 0.002), and SP (p < 0.001). Conclusions: Symptom improvement may result from better control of underlying pathologies or natural disease progression. However, the increased levels of SP and fractalkine/CX3CL1 suggest sustained neurogenic inflammation, while elevated IL-1Ra and IL-10 indicate a potential compensatory anti-inflammatory response.
- 20 June 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (13) , 4406
Open AccessLong-Term Evolution of Chronic Neuropathic Ocular Pain and Dry Eye Following Corneal Refractive Surgery
Background/Objectives: Chronic neuropathic ocular pain (NOP) can manifest concurrently with dry eye (DE) symptoms following ocular surgical procedures. Due to its low prevalence, NOP remains an underrecognized and underdiagnosed postoperative complication, leading to suboptimal management. This study evaluated the long-term evolution of symptoms, signs, and tear biomarkers in patients with NOP and DE after corneal refractive surgery (RS). Methods: Patients with chronic NOP and persistent DE-related symptoms after corneal RS were assessed in two visits (V1 and V2), at least two years apart. Symptoms (DE, pain, anxiety, and depression) were measured with specific questionnaires. Clinical examination included a slit-lamp ocular surface evaluation, corneal sensitivity measurement, and subbasal corneal nerve plexus evaluation. Basal tear samples were collected, and a 20-plex cytokine panel and Substance P (SP) were assayed. Results: Twenty-three patients (35.57 ± 8.43 years) were included, with a mean time between visits of 4.83 ± 1.10 years. DE symptoms, measured with the Ocular Surface Disease Index questionnaire, improved at V2 (p < 0.001), along with a reduction in anxiety and depression levels, measured with the Hospital Anxiety and Depression Scale (p = 0.027). Corneal staining also decreased (p < 0.001), while subbasal nerve plexus parameters and corneal sensitivity remained unchanged. Tear analysis revealed increased concentrations of fractalkine/CX3CL1 (p = 0.039), interleukin (IL)-1 receptor antagonist (Ra) (p = 0.025), IL-10 (p = 0.002), and SP (p < 0.001). Conclusions: Symptom improvement may result from better control of underlying pathologies or natural disease progression. However, the increased levels of SP and fractalkine/CX3CL1 suggest sustained neurogenic inflammation, while elevated IL-1Ra and IL-10 indicate a potential compensatory anti-inflammatory response.
- Open Access
- 14 May 2025
- Published by Elsevier in Contact Lens and Anterior Eye
- p. 102424
The association between corneal immune cell dynamics and comfort in silicone hydrogel contact lens wearers
- 14 May 2025
- Published by Elsevier in Contact Lens and Anterior Eye
- p. 102424
Open AccessThe association between corneal immune cell dynamics and comfort in silicone hydrogel contact lens wearers
- 18 June 2024
- Published by Taylor & Francis in Ocular Immunology and Inflammation
- Vol. 32 (10) , 2339-2347
Tear Cytokines as Predictive Biomarkers of Success in Contact Lens Discomfort Management
To analyze changes in tear levels of inflammatory mediators in symptomatic contact lens (CL) wearers after refitting with daily disposable CLs and to identify potential biomarkers of success in CL discomfort (CLD) management. Symptomatic CL wearers (CLDEQ-8 ≥ 12) were refitted (V1) with daily disposable CLs (Delefilcon A). After one month (V2), participants were classified into the post-fitting non-symptomatic (CLDEQ p ≤ 0.044). The detection rates of IL-1β, IL-9, MIP-1α/CCL3, and MMP-9 at V1 (p ≤ 0.045) and IL-17A at V2 (p ≤ 0.014) were higher in the post-fitting symptomatic group. The tear IL-9 concentration was increased at V2 (p = 0.018). The tear concentrations of fractalkine/CX3CL1, IL-2, IL-6, IL-10, MCP-3/CCL7, MIP-1β, NGF, RANTES/CCL5, and TNF-α were higher in the post-fitting symptomatic group (p ≤ 0.044). Additionally, levels of fractalkine/CX3CL1, IL-2, IL-6, IL-10, RANTES/CCL5, and TNF-α at V1 were significantly associated with the post-fitting grouping (p ≤ 0.044). Low tear concentrations of specific inflammatory mediators may be used as a predictive biomarker of success for refitting symptomatic CL wearers with daily disposable CLs. However, complementary treatments might be required for symptomatic CL wearers with higher levels of these inflammatory molecules.
- 18 June 2024
- Published by Taylor & Francis in Ocular Immunology and Inflammation
- Vol. 32 (10) , 2339-2347
Tear Cytokines as Predictive Biomarkers of Success in Contact Lens Discomfort Management
To analyze changes in tear levels of inflammatory mediators in symptomatic contact lens (CL) wearers after refitting with daily disposable CLs and to identify potential biomarkers of success in CL discomfort (CLD) management. Symptomatic CL wearers (CLDEQ-8 ≥ 12) were refitted (V1) with daily disposable CLs (Delefilcon A). After one month (V2), participants were classified into the post-fitting non-symptomatic (CLDEQ p ≤ 0.044). The detection rates of IL-1β, IL-9, MIP-1α/CCL3, and MMP-9 at V1 (p ≤ 0.045) and IL-17A at V2 (p ≤ 0.014) were higher in the post-fitting symptomatic group. The tear IL-9 concentration was increased at V2 (p = 0.018). The tear concentrations of fractalkine/CX3CL1, IL-2, IL-6, IL-10, MCP-3/CCL7, MIP-1β, NGF, RANTES/CCL5, and TNF-α were higher in the post-fitting symptomatic group (p ≤ 0.044). Additionally, levels of fractalkine/CX3CL1, IL-2, IL-6, IL-10, RANTES/CCL5, and TNF-α at V1 were significantly associated with the post-fitting grouping (p ≤ 0.044). Low tear concentrations of specific inflammatory mediators may be used as a predictive biomarker of success for refitting symptomatic CL wearers with daily disposable CLs. However, complementary treatments might be required for symptomatic CL wearers with higher levels of these inflammatory molecules.
- Open Access
- 16 May 2024
- Published by Universidad de La Salle in Ciencia y Tecnología para la Salud Visual y Ocular
- Vol. 21, 6
Long-term evolution of signs and symptoms in contact lens wearers
The purposes of the study were to describe the evolution of contact lens (CL) prescription patterns during a long-term period in the same sample of CL wearers evaluated in a protocolized manner, and to determine the predisposing factors responsible for the changes observed in CL fittings. Data on clinical files (CL type, wearing time, visual acuity, symptoms, and clinical signs) of CL wearers who attended a Spanish eye setting between 2010 and 2020 were collected. The profile of CL wearers was compared between 2010 and 2020. The CL characteristics were compared between CL types, replacements, and designs. Finally, factors predicting a change in CL fitting were assessed. Seventy-four CL wearers (28 men and 46 women) aged 39.0 ± 9.1 years old were included. Silicone hydrogel (p = 0.01) and daily disposable (p < 0.001) CL fittings increased during the follow-up period. The main reasons for CL refitting were the appearance or increase of clinical signs and/or symptoms. CL wearing time and visual acuity differed between CL types and replacements (p ≤ 0.02). Both, rigid and conventional replacement CL wear were associated with a lower probability of CL fitting changes (p ≤ 0.03). In conclusion, this study provides useful clinical information about the profile of successful long-term CL wearers in the last decade. Adequate aftercare examinations of long-term CL wearers can avoid worsening of signs and symptoms. Hydrogel and frequent replacement CL wearers are more likely to undergo CL refitting when compared to rigid corneal and conventional CL wearers.
- 16 May 2024
- Published by Universidad de La Salle in Ciencia y Tecnología para la Salud Visual y Ocular
- Vol. 21, 6
Open AccessLong-term evolution of signs and symptoms in contact lens wearers
The purposes of the study were to describe the evolution of contact lens (CL) prescription patterns during a long-term period in the same sample of CL wearers evaluated in a protocolized manner, and to determine the predisposing factors responsible for the changes observed in CL fittings. Data on clinical files (CL type, wearing time, visual acuity, symptoms, and clinical signs) of CL wearers who attended a Spanish eye setting between 2010 and 2020 were collected. The profile of CL wearers was compared between 2010 and 2020. The CL characteristics were compared between CL types, replacements, and designs. Finally, factors predicting a change in CL fitting were assessed. Seventy-four CL wearers (28 men and 46 women) aged 39.0 ± 9.1 years old were included. Silicone hydrogel (p = 0.01) and daily disposable (p < 0.001) CL fittings increased during the follow-up period. The main reasons for CL refitting were the appearance or increase of clinical signs and/or symptoms. CL wearing time and visual acuity differed between CL types and replacements (p ≤ 0.02). Both, rigid and conventional replacement CL wear were associated with a lower probability of CL fitting changes (p ≤ 0.03). In conclusion, this study provides useful clinical information about the profile of successful long-term CL wearers in the last decade. Adequate aftercare examinations of long-term CL wearers can avoid worsening of signs and symptoms. Hydrogel and frequent replacement CL wearers are more likely to undergo CL refitting when compared to rigid corneal and conventional CL wearers.
- Open Access
- 6 March 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 13 (5) , 1197-1210
Short-Term Efficacy of Ophthalmic Cyclosporine: A 0.1% Cationic Emulsion in Dry Eye Patients Assessed Under Controlled Environment
Introduction To evaluate the short-term efficacy of cyclosporine A (CsA)-0.1% cationic emulsion (CE) in patients with dry eye disease (DED) and mitigation of the inflammatory flares triggered by desiccating stress environments. Methods A single-center non-randomized clinical trial was performed at a tertiary care setting. Twenty patients with DED treated with CsA 0.1% CE were exposed to a normal controlled environment (NCE) (23 °C, 50% relative humidity) and an adverse controlled environment (ACE) (23 °C, 10% relative humidity, 0.43 m/s localized airflow) during baseline and the 1- and 3-month visits. Patients underwent the following evaluations: conjunctival hyperemia and staining, corneal fluorescein staining (CFS) using the Oxford and Cornea and Contact Lens Research Unit (CCLRU) scale, meibomian gland (MG) secretion quality, Dry Eye Questionnaire-5, Symptom Assessment in Dry Eye (SANDE II), and Change in Dry Eye Symptoms Questionnaire. Multivariate models were adjusted for statistical analysis. Results Nineteen women and one man (mean age, 58.9 ± 12.3 years) completed the study. All symptom questionnaires, CFS, conjunctival hyperemia and staining, and MG secretion quality improved (p ≤ 0.003) with 1 month of treatment; improvements were maintained after 3 months (p ≤ 0.02), except for SANDE II (p ≥ 0.07). The CFS worsening (total CCLRU) after baseline ACE exposure (from 8.6 to 10.1) was higher, although not significant (p = 0.64), compared with 1 month (from 5.4 to 5.8) and 3 months (from 5.0 to 5.9) after treatment. Conclusion Topical CsA-0.1% CE improved DED signs and symptoms after 1 month of treatment under controlled environmental conditions. Future studies should confirm the benefit of CsA-0.1% CE in desiccating stress environments. Trial Registration ClinicalTrials.gov identifier, NCT04492878.
- 6 March 2024
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 13 (5) , 1197-1210
Open AccessShort-Term Efficacy of Ophthalmic Cyclosporine: A 0.1% Cationic Emulsion in Dry Eye Patients Assessed Under Controlled Environment
Introduction To evaluate the short-term efficacy of cyclosporine A (CsA)-0.1% cationic emulsion (CE) in patients with dry eye disease (DED) and mitigation of the inflammatory flares triggered by desiccating stress environments. Methods A single-center non-randomized clinical trial was performed at a tertiary care setting. Twenty patients with DED treated with CsA 0.1% CE were exposed to a normal controlled environment (NCE) (23 °C, 50% relative humidity) and an adverse controlled environment (ACE) (23 °C, 10% relative humidity, 0.43 m/s localized airflow) during baseline and the 1- and 3-month visits. Patients underwent the following evaluations: conjunctival hyperemia and staining, corneal fluorescein staining (CFS) using the Oxford and Cornea and Contact Lens Research Unit (CCLRU) scale, meibomian gland (MG) secretion quality, Dry Eye Questionnaire-5, Symptom Assessment in Dry Eye (SANDE II), and Change in Dry Eye Symptoms Questionnaire. Multivariate models were adjusted for statistical analysis. Results Nineteen women and one man (mean age, 58.9 ± 12.3 years) completed the study. All symptom questionnaires, CFS, conjunctival hyperemia and staining, and MG secretion quality improved (p ≤ 0.003) with 1 month of treatment; improvements were maintained after 3 months (p ≤ 0.02), except for SANDE II (p ≥ 0.07). The CFS worsening (total CCLRU) after baseline ACE exposure (from 8.6 to 10.1) was higher, although not significant (p = 0.64), compared with 1 month (from 5.4 to 5.8) and 3 months (from 5.0 to 5.9) after treatment. Conclusion Topical CsA-0.1% CE improved DED signs and symptoms after 1 month of treatment under controlled environmental conditions. Future studies should confirm the benefit of CsA-0.1% CE in desiccating stress environments. Trial Registration ClinicalTrials.gov identifier, NCT04492878.
- Open Access
- 30 June 2021
- Published by Universidad de La Salle in Ciencia y Tecnología para la Salud Visual y Ocular
- Vol. 19 (1) , 59-67
Cambios en la calidad visual asociados al uso de las lentes de contacto Biofinity Energys
Las lentes de contacto (LC) Biofinity EnergysTM han sido desarrolladas para manejar el síndrome visual informático (SVI). El objetivo del presente estudio es evaluar la calidad visual durante el uso de estas lentes, comparadas con unas lentes de diseño esférico (Biofinity®). En una única visita se adaptaron las dos LC a cada sujeto en ambos ojos de forma aleatoria y enmascarada, y se evaluó la agudeza visual (AV), la sensibilidad al contraste (SC), y la aberrometría ocular. Durante el porte de las LC Biofinity EnergysTM se observó una disminución de la AV monocular y binocular y de la SC monocular para la frecuencia de 18 ciclos por grado. Además, se ha visto un aumento de la magnitud de tetrafoil oblicuo y astigmatismo secundario. Por tanto, se puede concluir que estas LC inducen ciertas aberraciones de alto orden, que podrían explicar la disminución de la calidad visual observada.
- 30 June 2021
- Published by Universidad de La Salle in Ciencia y Tecnología para la Salud Visual y Ocular
- Vol. 19 (1) , 59-67
Open AccessCambios en la calidad visual asociados al uso de las lentes de contacto Biofinity Energys
Las lentes de contacto (LC) Biofinity EnergysTM han sido desarrolladas para manejar el síndrome visual informático (SVI). El objetivo del presente estudio es evaluar la calidad visual durante el uso de estas lentes, comparadas con unas lentes de diseño esférico (Biofinity®). En una única visita se adaptaron las dos LC a cada sujeto en ambos ojos de forma aleatoria y enmascarada, y se evaluó la agudeza visual (AV), la sensibilidad al contraste (SC), y la aberrometría ocular. Durante el porte de las LC Biofinity EnergysTM se observó una disminución de la AV monocular y binocular y de la SC monocular para la frecuencia de 18 ciclos por grado. Además, se ha visto un aumento de la magnitud de tetrafoil oblicuo y astigmatismo secundario. Por tanto, se puede concluir que estas LC inducen ciertas aberraciones de alto orden, que podrían explicar la disminución de la calidad visual observada.