Giulio Lievore
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Giulio Lievore has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Chiara De Luca
Department of Chemical, Pharmaceutical and Agricultural Sciences, University of Ferrara, Via L. Borsari 46, 44121, Ferrara, Italy
9 shared publications - Simona Felletti
Department of Environmental and Prevention Sciences, University of Ferrara, via L. Borsari 46, Ferrara 44121, Italy
9 shared publications - Alberto Cavazzini
Department of Chemical, Pharmaceutical and Agricultural Sciences, University of Ferrara, 44121 Ferrara, Italy
8 shared publications - Martina Catani
Department of Chemical, Pharmaceutical and Agricultural Sciences, University of Ferrara, Via L. Borsari 46, 44121 Ferrara, Italy
7 shared publications - Tatiana Chenet
Department of Environmental and Prevention Sciences, University of Ferrara, Via L. Borsari 46, 44121 Ferrara, Italy
5 shared publications - Luisa Pasti
Department of Environmental and Prevention Sciences, University of Ferrara, Ferrara, Italy
4 shared publications
Latest Publications
- Open Access
- 17 May 2022
- Published by MDPI AG in Separations
- Vol. 9 (5) , 125
Benefits of a Mixed-Mode Stationary Phase to Address the Challenging Purification of an Industrially Relevant Peptide: A Proof-of-Concept Study
Peptides are a class of biomolecules with a great potential from the therapeutic point of view, because of their unique biological properties. Industrially, the production stategies adopted produce both the target peptide and a series of impurities that must be removed. Preparative chromatography is the technique of choice for the large-scale purification of biomolecules, generally performed in reversed-phase mode, using hydrophobic adsorbents (e.g., C8 stationary phases). A promising and innovative alternative is represented by mixed-mode columns, which bear two different ligands on the particle surface, exploiting two different retention mechanisms to improve the separation. This work represents a proof-of-concept study focused on the comparison of a hydrophobic adsorbent and a mixed-mode one (bearing both hydrophobic groups and charged ones) for the purification of a crude peptide mixture. Thanks to more-favourable thermodynamics, it was found that, when collecting the whole peak excluding fractions of the peak tail, the mixed-mode column led to an increase in the recovery of roughly +15%, together with a slight improvement in purity at the same time, with respect to the traditional hydrophobic column. In addition, if the whole peak, including the tail, is collected, the performance of the two columns are similar in terms of purity and recovery, but the pepetide elutes as a narrower peak with the mixed mode. This leads to a collection pool showing a much-higher peptide concentration and to lower solvent volumes needed, which is a beneficial achievement when targeting more sustainable processes. These results are very advantageous from the industrial viewpoint, because they also involve a decrease in the peptide amount contained in the peak tail, which must be reprocessed again to satisfy purity requirements.
- 17 May 2022
- Published by MDPI AG in Separations
- Vol. 9 (5) , 125
Open AccessBenefits of a Mixed-Mode Stationary Phase to Address the Challenging Purification of an Industrially Relevant Peptide: A Proof-of-Concept Study
Peptides are a class of biomolecules with a great potential from the therapeutic point of view, because of their unique biological properties. Industrially, the production stategies adopted produce both the target peptide and a series of impurities that must be removed. Preparative chromatography is the technique of choice for the large-scale purification of biomolecules, generally performed in reversed-phase mode, using hydrophobic adsorbents (e.g., C8 stationary phases). A promising and innovative alternative is represented by mixed-mode columns, which bear two different ligands on the particle surface, exploiting two different retention mechanisms to improve the separation. This work represents a proof-of-concept study focused on the comparison of a hydrophobic adsorbent and a mixed-mode one (bearing both hydrophobic groups and charged ones) for the purification of a crude peptide mixture. Thanks to more-favourable thermodynamics, it was found that, when collecting the whole peak excluding fractions of the peak tail, the mixed-mode column led to an increase in the recovery of roughly +15%, together with a slight improvement in purity at the same time, with respect to the traditional hydrophobic column. In addition, if the whole peak, including the tail, is collected, the performance of the two columns are similar in terms of purity and recovery, but the pepetide elutes as a narrower peak with the mixed mode. This leads to a collection pool showing a much-higher peptide concentration and to lower solvent volumes needed, which is a beneficial achievement when targeting more sustainable processes. These results are very advantageous from the industrial viewpoint, because they also involve a decrease in the peptide amount contained in the peak tail, which must be reprocessed again to satisfy purity requirements.
- Open Access
Downstream Processing of Therapeutic Peptides by Means of Preparative Liquid Chromatography
The market of biomolecules with therapeutic scopes, including peptides, is continuously expanding. The interest towards this class of pharmaceuticals is stimulated by the broad range of bioactivities that peptides can trigger in the human body. The main production methods to obtain peptides are enzymatic hydrolysis, microbial fermentation, recombinant approach and, especially, chemical synthesis. None of these methods, however, produce exclusively the target product. Other species represent impurities that, for safety and pharmaceutical quality reasons, must be removed. The remarkable production volumes of peptide mixtures have generated a strong interest towards the purification procedures, particularly due to their relevant impact on the manufacturing costs. The purification method of choice is mainly preparative liquid chromatography, because of its flexibility, which allows one to choose case-by-case the experimental conditions that most suitably fit that particular purification problem. Different modes of chromatography that can cover almost every separation case are reviewed in this article. Additionally, an outlook to a very recent continuous chromatographic process (namely Multicolumn Countercurrent Solvent Gradient Purification, MCSGP) and future perspectives regarding purification strategies will be considered at the end of this review.
Open AccessDownstream Processing of Therapeutic Peptides by Means of Preparative Liquid Chromatography
The market of biomolecules with therapeutic scopes, including peptides, is continuously expanding. The interest towards this class of pharmaceuticals is stimulated by the broad range of bioactivities that peptides can trigger in the human body. The main production methods to obtain peptides are enzymatic hydrolysis, microbial fermentation, recombinant approach and, especially, chemical synthesis. None of these methods, however, produce exclusively the target product. Other species represent impurities that, for safety and pharmaceutical quality reasons, must be removed. The remarkable production volumes of peptide mixtures have generated a strong interest towards the purification procedures, particularly due to their relevant impact on the manufacturing costs. The purification method of choice is mainly preparative liquid chromatography, because of its flexibility, which allows one to choose case-by-case the experimental conditions that most suitably fit that particular purification problem. Different modes of chromatography that can cover almost every separation case are reviewed in this article. Additionally, an outlook to a very recent continuous chromatographic process (namely Multicolumn Countercurrent Solvent Gradient Purification, MCSGP) and future perspectives regarding purification strategies will be considered at the end of this review.
- 1 January 2021
- Published by Elsevier in Journal of Chromatography A
- Vol. 1637, 461854
Mass transfer kinetics on modern Whelk-O1 chiral stationary phases made on fully- and superficially-porous particles
- 1 January 2021
- Published by Elsevier in Journal of Chromatography A
- Vol. 1637, 461854
Mass transfer kinetics on modern Whelk-O1 chiral stationary phases made on fully- and superficially-porous particles
- 1 October 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1630, 461532
Shedding light on mechanisms leading to convex-upward van Deemter curves on a cellulose tris(4-chloro-3-methylphenylcarbamate)-based chiral stationary phase
- 1 October 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1630, 461532
Shedding light on mechanisms leading to convex-upward van Deemter curves on a cellulose tris(4-chloro-3-methylphenylcarbamate)-based chiral stationary phase
- 1 August 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1625, 461304
From batch to continuous chromatographic purification of a therapeutic peptide through multicolumn countercurrent solvent gradient purification
- 1 August 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1625, 461304
From batch to continuous chromatographic purification of a therapeutic peptide through multicolumn countercurrent solvent gradient purification
- 1 April 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1616, 460789
Modeling the nonlinear behavior of a bioactive peptide in reversed-phase gradient elution chromatography
- 1 April 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1616, 460789
Modeling the nonlinear behavior of a bioactive peptide in reversed-phase gradient elution chromatography
- 3 March 2020
- Published by Wiley in Journal of Separation Science
- Vol. 43 (9-10) , 1737-1745
Investigation of mass transfer properties and kinetic performance of high‐efficiency columns packed with C18 sub‐2 μm fully and superficially porous particles
Three columns packed with 2.0 μm superficially porous particles, 1.7 μm fully porous particles, and monodisperse 1.9 μm fully porous particles with narrow particle size distribution have been deeply characterized from a kinetic point of view. The 1.9 μm column showed excellent kinetic performance, comparable to that of the superficially porous one. These two columns also exhibit flatter c‐branches of the van Deemter curve compared to the 1.7 μm fully porous particles column, resulting in smaller loss of efficiency when they are operated at higher flow rates than the optimal ones. The independent evaluation of each contribution to band broadening has revealed that the difference in kinetic performance comes from the very small eddy dispersion contribution on the 1.9 μm column, surprisingly even lower than that of the superficially porous one. This finding suggests a very good packing of the monodisperse 1.9 μm column. On the other hand, the potential of 1.7 μm fully porous particles is completely broken down by the strong frictional heating effect already arising at relatively low flow rates.
- 3 March 2020
- Published by Wiley in Journal of Separation Science
- Vol. 43 (9-10) , 1737-1745
Investigation of mass transfer properties and kinetic performance of high‐efficiency columns packed with C18 sub‐2 μm fully and superficially porous particles
Three columns packed with 2.0 μm superficially porous particles, 1.7 μm fully porous particles, and monodisperse 1.9 μm fully porous particles with narrow particle size distribution have been deeply characterized from a kinetic point of view. The 1.9 μm column showed excellent kinetic performance, comparable to that of the superficially porous one. These two columns also exhibit flatter c‐branches of the van Deemter curve compared to the 1.7 μm fully porous particles column, resulting in smaller loss of efficiency when they are operated at higher flow rates than the optimal ones. The independent evaluation of each contribution to band broadening has revealed that the difference in kinetic performance comes from the very small eddy dispersion contribution on the 1.9 μm column, surprisingly even lower than that of the superficially porous one. This finding suggests a very good packing of the monodisperse 1.9 μm column. On the other hand, the potential of 1.7 μm fully porous particles is completely broken down by the strong frictional heating effect already arising at relatively low flow rates.