Lijuan Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lijuan Liang has a total of 140 co-authors. Here are the top co-authors by number of shared publications:
- Kun Huang
China West Normal University
11 shared publications Jianlong Zhao
8 shared publicationsXianfu Wei
Beijing Institute of Graphic Communication
8 shared publicationsBeiqing Huang
Beijing Institute of Graphic Communication
6 shared publicationsYimeng Sun
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
6 shared publications- Jianlong Zhao
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
5 shared publications
Latest Publications
- Open Access
- 9 April 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (4) , 210
Label-Free Impedimetric Biosensor Based on Molecularly Imprinted PPy/MWCNTs Nanocomposites for Sensitive and Selective Detection of Escherichia coli
Escherichia coli (E. coli) is a microorganism commonly found in water and food matrices, and its rapid and accurate detection is crucial for maintaining public health and ensuring food safety. However, traditional molecularly imprinted polymer (MIP) sensors often face challenges such as tedious template removal and prolonged sensing times. This study develops a label-free bacterial molecularly imprinted sensor that utilizes the synergistic effect of polypyrrole (PPy) and multi-walled carbon nanotubes (MWCNTs) to achieve highly sensitive detection of E. coli. Based on the large specific surface area and superior conductivity of MWCNTs, as well as the favorable electrochemical polymerization properties of PPy, a PPy/MWCNTs composite film was fabricated via a one-step electropolymerization process. The prepared sensor exhibited excellent kinetic characteristics, with a template removal time of only 15 min, and could be regenerated and used for subsequent detection within 30 min. Under optimized conditions, the biosensor showed a satisfactory linear response over the concentration range of 102–108 CFU/mL, with a low detection limit of 65 CFU/mL (3σ/S). Furthermore, recovery experiments conducted in tap water and lemon juice samples yielded satisfactory recoveries ranging from 87.1% to 114.8%, demonstrating the reliability and practical applicability of the proposed sensor for bacterial detection in real samples. This sensor offers advantages such as simple preparation, low material cost, and high sensitivity, providing a reliable and practical analytical platform for the rapid and reliable detection of bacteria.
- 9 April 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (4) , 210
Open AccessLabel-Free Impedimetric Biosensor Based on Molecularly Imprinted PPy/MWCNTs Nanocomposites for Sensitive and Selective Detection of Escherichia coli
Escherichia coli (E. coli) is a microorganism commonly found in water and food matrices, and its rapid and accurate detection is crucial for maintaining public health and ensuring food safety. However, traditional molecularly imprinted polymer (MIP) sensors often face challenges such as tedious template removal and prolonged sensing times. This study develops a label-free bacterial molecularly imprinted sensor that utilizes the synergistic effect of polypyrrole (PPy) and multi-walled carbon nanotubes (MWCNTs) to achieve highly sensitive detection of E. coli. Based on the large specific surface area and superior conductivity of MWCNTs, as well as the favorable electrochemical polymerization properties of PPy, a PPy/MWCNTs composite film was fabricated via a one-step electropolymerization process. The prepared sensor exhibited excellent kinetic characteristics, with a template removal time of only 15 min, and could be regenerated and used for subsequent detection within 30 min. Under optimized conditions, the biosensor showed a satisfactory linear response over the concentration range of 102–108 CFU/mL, with a low detection limit of 65 CFU/mL (3σ/S). Furthermore, recovery experiments conducted in tap water and lemon juice samples yielded satisfactory recoveries ranging from 87.1% to 114.8%, demonstrating the reliability and practical applicability of the proposed sensor for bacterial detection in real samples. This sensor offers advantages such as simple preparation, low material cost, and high sensitivity, providing a reliable and practical analytical platform for the rapid and reliable detection of bacteria.
- Open Access
- 27 March 2026
- Published by Elsevier in SSRN Electronic Journal
A low-cost and simple pH composite material based on a tableting strategy
A highly sensitive, easily miniaturizable composite sensing electrode designed is proposed for rapid on-site pH detection. Unlike metal oxide-based pH sensors that utilise single-function monomers, our study aims to enhance the inherent selectivity of hydrated ruthenium oxide by incorporating hydroxyl groups to modulate its structural properties. Additionally, a hydrogen-bond-rich molecular interface is constructed through the polymerization of hydrogen ions with GP, thereby improving the stability of the pH detection process. The proposed sensor exhibits excellent linear response across a pH range of 1 to 12, with sensitivity approaching the theoretical Nernstian value (56.2 mV pH⁻¹, R²=0.9996). The RuO₂·xH₂O/GP electrode is not only suitable for pH measurements in environmental water samples, such as those from rivers and lakes, but also demonstrates strong potential for application in biological sample analysis. Moreover, the electrode can be fabricated into various forms, offering a viable pathway for scalable applications, including portable devices and disposable sensors.
- 27 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA low-cost and simple pH composite material based on a tableting strategy
A highly sensitive, easily miniaturizable composite sensing electrode designed is proposed for rapid on-site pH detection. Unlike metal oxide-based pH sensors that utilise single-function monomers, our study aims to enhance the inherent selectivity of hydrated ruthenium oxide by incorporating hydroxyl groups to modulate its structural properties. Additionally, a hydrogen-bond-rich molecular interface is constructed through the polymerization of hydrogen ions with GP, thereby improving the stability of the pH detection process. The proposed sensor exhibits excellent linear response across a pH range of 1 to 12, with sensitivity approaching the theoretical Nernstian value (56.2 mV pH⁻¹, R²=0.9996). The RuO₂·xH₂O/GP electrode is not only suitable for pH measurements in environmental water samples, such as those from rivers and lakes, but also demonstrates strong potential for application in biological sample analysis. Moreover, the electrode can be fabricated into various forms, offering a viable pathway for scalable applications, including portable devices and disposable sensors.
- Open Access
- 22 March 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (3) , 179
Femtosecond Laser Micropore-Enhanced Miniaturised PCB-Based Microbial Fuel Cell Biosensor for Toxicity Detection
This study presents a low-cost, small-scale single-chamber microbial fuel cell (MFC) toxicity biosensor fabricated on a printed circuit board (PCB) and a 3D-printed chamber with a volume of 120 μL. The anode consists of a screen-printed carbon electrode on the PCB, while the air cathode is a carbon paper electrode. To address poor adhesion of microorganisms to the smooth anode surface, femtosecond laser processing was used to fabricate a micropore array with 40 μm pores on the electrode. This method can create micropores on the anode surface without damaging the screen-printed electrodes, the PCB substrate, or the pads. These micropores increase the anode’s surface area and hydrophilicity, allowing more microbial coatings to firmly adhere to its surface. In this study, the MFC utilised Rhizobium rosettiformans W3, extracted from activated sludge at a wastewater treatment plant, as the anode microorganism. Its aerobic nature simplifies the design of MFCs, enabling a single-chamber structure and miniaturisation. Using formaldehyde solution as a toxicity sample to test the biosensor’s performance, a 0.1% concentration significantly reduced the sensor’s output power.
- 22 March 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (3) , 179
Open AccessFemtosecond Laser Micropore-Enhanced Miniaturised PCB-Based Microbial Fuel Cell Biosensor for Toxicity Detection
This study presents a low-cost, small-scale single-chamber microbial fuel cell (MFC) toxicity biosensor fabricated on a printed circuit board (PCB) and a 3D-printed chamber with a volume of 120 μL. The anode consists of a screen-printed carbon electrode on the PCB, while the air cathode is a carbon paper electrode. To address poor adhesion of microorganisms to the smooth anode surface, femtosecond laser processing was used to fabricate a micropore array with 40 μm pores on the electrode. This method can create micropores on the anode surface without damaging the screen-printed electrodes, the PCB substrate, or the pads. These micropores increase the anode’s surface area and hydrophilicity, allowing more microbial coatings to firmly adhere to its surface. In this study, the MFC utilised Rhizobium rosettiformans W3, extracted from activated sludge at a wastewater treatment plant, as the anode microorganism. Its aerobic nature simplifies the design of MFCs, enabling a single-chamber structure and miniaturisation. Using formaldehyde solution as a toxicity sample to test the biosensor’s performance, a 0.1% concentration significantly reduced the sensor’s output power.
- 19 February 2026
- Published by Elsevier in Food Chemistry
- Vol. 509, 148519
Synchronous point-of-care visualization and sensitive detection of amantadine by pattern-assisted electrochromic-photoelectrochemical dual-mode sensor
- 19 February 2026
- Published by Elsevier in Food Chemistry
- Vol. 509, 148519
Synchronous point-of-care visualization and sensitive detection of amantadine by pattern-assisted electrochromic-photoelectrochemical dual-mode sensor
- 18 December 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 36 (2) , 1695-1704
Dual-Response Fluorescent Probe for HOCl and Viscosity and Cell Imaging Application
- 18 December 2025
- Published by Springer Nature in Journal of Fluorescence
- Vol. 36 (2) , 1695-1704
Dual-Response Fluorescent Probe for HOCl and Viscosity and Cell Imaging Application
- 13 October 2025
- Published by Elsevier in Journal of Molecular Structure
- Vol. 1351
Novel nickel metal-organic framework as sensitive fluorescence sensor for benzidine, Fe3+, Cr3+, and Hg2+ in aqueous solution
- 13 October 2025
- Published by Elsevier in Journal of Molecular Structure
- Vol. 1351
Novel nickel metal-organic framework as sensitive fluorescence sensor for benzidine, Fe3+, Cr3+, and Hg2+ in aqueous solution
- 23 September 2025
- Published by Elsevier in Journal of Molecular Structure
- Vol. 1350
Modulating AIE ligand of cadmium metal-organic framework to realize turn-on sulfide ion sensing
- 23 September 2025
- Published by Elsevier in Journal of Molecular Structure
- Vol. 1350
Modulating AIE ligand of cadmium metal-organic framework to realize turn-on sulfide ion sensing
- Open Access
- 14 July 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (7) , 454
Ultra-Sensitive Detection of Chloramphenicol by CdS@NiMoS Nanorods-Based Photoelectrochemical Aptasensor
A novel nanomaterial photoelectrochemical aptamer sensor based on CdS@NiMoS heterojunction nanocomposites was constructed for highly sensitive detection of chloramphenicol (CAP) in antibiotic residues. Through optimization of the material synthesis process, the optimal doping ratio of MoS2 to Ni3+ (70% MoS2 and 10% Ni3+) was identified, which significantly enhanced the photogenerated carrier separation efficiency. In thin-film preparation, comparative analysis of four film-forming methods led to the determination of an optimal process with stability. To achieve highly specific CAP detection, the nanocomposite chip was integrated with nucleic acid aptamer biorecognition elements within a standard three-electrode detection system. Experimental results demonstrated a linear response (R2 = 0.998) in the 0.1–2 μM concentration range, with a detection limit of 3.69 nM (3σ/S).
- 14 July 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (7) , 454
Open AccessUltra-Sensitive Detection of Chloramphenicol by CdS@NiMoS Nanorods-Based Photoelectrochemical Aptasensor
A novel nanomaterial photoelectrochemical aptamer sensor based on CdS@NiMoS heterojunction nanocomposites was constructed for highly sensitive detection of chloramphenicol (CAP) in antibiotic residues. Through optimization of the material synthesis process, the optimal doping ratio of MoS2 to Ni3+ (70% MoS2 and 10% Ni3+) was identified, which significantly enhanced the photogenerated carrier separation efficiency. In thin-film preparation, comparative analysis of four film-forming methods led to the determination of an optimal process with stability. To achieve highly specific CAP detection, the nanocomposite chip was integrated with nucleic acid aptamer biorecognition elements within a standard three-electrode detection system. Experimental results demonstrated a linear response (R2 = 0.998) in the 0.1–2 μM concentration range, with a detection limit of 3.69 nM (3σ/S).